CS Paper Radar

Expert-like Bone Ultrasound Segmentation through Expert-in-the-loop Mask-conditioned Progressive Learning

Arash Tavangar, Larissa K. Chiu, Hamidreza Khodashenas, Gregory K. Berry, Amir Hooshiar

eess.IV cs.CV ·submitted 2026-08-31 23:24 UTC · v1
top venue

Abstract

Manual annotation remains a major bottleneck in ultrasound (US) bone segmentation, where experts typically iteratively refine rough brush masks rather than delineating precise contours in a single pass. We present ExiL, a mask-conditioned progressive learning framework that models annotation as a structured refinement trajectory. ExiL combines a synthetic expert-like brush simulator based on signed distance fields with a lightweight 7.8M-parameter U-Net that learns to complete and refine imperfect masks from US images. During deployment, an expert mode updates the model directly from accepted refinements, enabling continual adaptation to expert behavior. Evaluated using UltraBones100k cadaver data for quantitative segmentation and a prospective volunteer dataset for annotation-efficiency analysis, ExiL reduced single-expert average annotation time from 60 to 20 seconds per frame (66.7\%) and improved mean Dice by approximately 0.045 over non-progressive training, while achieving 0.87 Dice and 2.7 px boundary error in the best trajectory-aware setting. With 10--50 ms inference, ExiL enables real-time, self-improving annotation for US-guided orthopedic workflows in practical clinical labeling.

Closest papers

Nearest neighbours by meaning across the whole index.

Pretrained, Curriculum-Tuned, and Ensembled: A Tracer-Aware Interactive Segmentation Pipeline for AutoPET V

cs.CV cs.AI ·2026-08-31 ·Xinglong Liang, Chunyao Lu, Tianyu Zhang, Jiaju Huang, Tao Tan +2 more
code/data similarity 0.70
Abstract

Interactive lesion segmentation in whole-body PET/CT requires a model to provide a strong initial prediction while also responding efficiently to sparse corrective scribbles during inference. This setting is particularly challenging because tracer distributions, physiological uptake patterns, lesion appearance, and acquisition characteristics differ substantially between FDG and PSMA studies. We present TRIAGE, Tracer-aware Refinement via Interactive Anatomy-Guided sEgmentation. The core backbone is a 3D STU-Net initialized through masked autoencoding pre-training with an asynchronous masking strategy, aiming to learn transferable anatomical and cross-modal representations before task-specific fine-tuning. In parallel, we train an auxiliary organ segmentation model whose predictions provide explicit anatomical context and help distinguish physiological uptake from malignant lesions. A dedicated tracer classifier first routes each study to an FDG- or PSMA-specific branch. Within each branch, a first-stage segmentation model consumes CT, PET, and organ context to generate an initial lesion mask. The initial prediction is then combined with cumulative foreground/background scribbles and refined by a second interactive segmentation network. The FDG and PSMA branches share the same overall processing pipeline but are trained independently to account for tracer-specific appearance and error modes. We additionally employ curriculum-style training and model ensembling to improve robustness across interaction steps and heterogeneous cohorts. Experiments are conducted using the official AutoPET V data and ten-fold split; quantitative results, ablations, and final test-set performance are left as placeholders to be completed after the challenge evaluation. Code: https://github.com/Liiiii2101/AUTOPET2026-MEDAI.

0.24

Anatomy-Aware Promptable Segmentation with Online Interactive Training for AUTOPET V

cs.CV cs.AI ·2026-08-28 ·Pablo Lozano-Jimenez, Sergio Romero-Tapiador, Ruben Tolosana
similarity 0.67
Abstract

We present an anatomy-aware, promptable model for whole-body lesion segmentation in FDG and PSMA PET/CT, developed for the AUTOPET V challenge. The proposed method is built as family of nnU-Net-based models and trained in two stages: i) a pre-training stage that produces a strong initial segmentation, and ii) an online interactive stage that learns to exploit scribble prompts, refining the prediction over successive interactions. Anatomical context is incorporated through organ supervision using a single shared head that predicts lesions and organs from the same features, which reduces false positives arising from physiological uptake. Also as the tracer (i.e., FDG/PSMA) is not provided at inference, we add a tracer classifier based on image processing and a random forest over coronal MIP features, routing each study to a combined FDG+PSMA model or to a PSMA-specific model. Across four-fold cross-validation the organ-supervised model achieves the best and most stable performance, the interactive stage improves the Dice score monotonically with each prompt, and PSMA-specific training yields the strongest tracer-wise results.

0.14

Medical Image Segmentation: Foundation Model Adaptation versus Task-Specific Training

cs.CV cs.AI ·2026-11-10 ·Emre Kutlusan, Yongmin Li
benchmark similarity 0.67
Abstract

Foundation models pretrained on large natural-image collections are increasingly adapted for medical image segmentation, in the expectation that they will replace models trained for each task. Most comparisons, however, use data from the training distribution and a single task-specific baseline whose configuration is rarely justified, and therefore provide limited evidence of performance at new clinical sites. It also remains unclear how much of a foundation model must be adapted, and what determines this. We adapted a foundation model, DINOv2, with strategies ranging from tuning only its bias terms to full fine-tuning, and compared it with U-Nets and ResU-Nets trained from scratch. Experiments covered colonoscopy, breast ultrasound and dermoscopy, with testing on held-out data from the training source and on independent datasets from other institutions. The adapted foundation model generalised better on every external dataset. Within the training distribution, the task-specific models remained competitive when training data were abundant, and delineated boundaries more precisely, while the foundation model more often missed small lesions. Only a small fraction of the foundation model required adaptation, and the capacity needed was determined by the imaging domain rather than by the adaptation method. A widely used polyp test set was also found to duplicate images from another benchmark. Foundation-model adaptation is therefore warranted where models must work across sites, with capacity selected on the target domain.

0.11

UltraBench 2: Towards Robust Evaluation of Vision Foundation Models on Ultrasound

cs.CV cs.LG ·2026-09-23 ·Ashwath Radhachandran, Adam Tupper, Christian Gagné, William Speier
benchmark similarity 0.67
Abstract

Benchmarking is an increasingly critical part of research in machine learning and the domains where it is applied, including healthcare. Yet, despite the steady development of new ultrasound foundation models in recent years, the development of well-designed benchmarks to evaluate them has lagged behind. This deficiency has led to fragmented and inconsistent evaluations of competing models, making it difficult to measure progress. To address this issue, we introduce UltraBench 2, a comprehensive benchmark with wide anatomical and task coverage, and a focus on standardization, reproducibility, and ease-of-use. Using this benchmark, we compare existing vision foundation models for ultrasound image analysis. Our analyses demonstrate that ultrasound-specific pretraining still leads on classification, but that state-of-the-art general-purpose models have drawn level on segmentation.

0.05

Computationally Efficient Pathology Segmentation using Knowledge Distillation from Foundation Models

eess.IV ·2026-09-03 ·Jiaqi Lv, Yijie Zhu, Saki Okada, Maxwell Stanley Renna, Robert Goldin +2 more
similarity 0.67
Abstract · Submitted to Medical Image Analysis

Automatic tissue segmentation is essential for large-scale analysis of histopathology whole-slide images (WSIs), but accurate pixel-level segmentation remains challenging. Pixel-level annotations are expensive to obtain, models pre-trained on natural images may transfer poorly to histopathology, and pathology foundation models, despite their strong representations, are computationally expensive to deploy at scale. We address these challenges with a foundation-model knowledge distillation framework for efficient tissue segmentation. We first train Virchow2-based segmentation teachers, including a LoRA-adapted variant, achieving state-of-the-art or highly competitive performance across four datasets: PUMA, IGNITE, BEETLE, and a private blood vessel segmentation dataset. We then transfer response-level and feature-level knowledge from these teachers into compact student networks. Distillation consistently improves student performance over supervised training alone, producing state-of-the-art or near state-of-the-art results with substantially fewer parameters and up to ten-fold higher inference throughput than foundation-model-based segmentation networks. These results show that foundation-model knowledge can be effectively transferred to efficient segmentation models for scalable deployment without compromising performance. Models trained on the public datasets will be released through TIAToolbox.

0.35

Learning Prostate Anatomy at Test Time for Cancer Detection in Micro-Ultrasound

cs.CV cs.LG ·2026-08-20 ·Obed Korshie Dzikunu, Mohammad Mahdi Abootorabi, Mohamed Harmanani, Paul F. R. Wilson, Emma Willis +5 more
code/data similarity 0.66
Abstract

Domain shift across clinical centers using different imaging hardware or acquisition protocols remains a fundamental barrier to deploying deep learning models for prostate cancer (PCa) detection. Existing test-time adaptation (TTA) methods address distribution shift through entropy minimization or augmentation-based self-supervision, correcting for statistical differences in image appearance but ignoring the anatomical structure of the target domain. We propose ANT, a segmentation-guided TTA framework that adapts a pretrained cancer detection encoder to the target domain by solving an auxiliary prostate segmentation task at test time, supervised by pseudo-masks from a frozen pretrained segmentation network. By aligning encoder representations to prostate anatomy in the target domain, ANT corrects domain-specific feature drift while preserving cancer-discriminative structure. The model was trained on 693 patients imaged with an earlier-generation micro-ultrasound scanner in a multi-center clinical trial, and evaluated on 118 patients acquired with a newer-generation system across two centers in another clinical trial. Under a leave-one-center-out protocol with identical evaluation conditions across all methods, ANT improves mean AUC by 2.9% and 3.6% at the biopsy-core and patient levels, respectively, over no adaptation, outperforming TTA baselines. Code is available at: https://github.com/ObedDzik/ant.git.

0.51

US-VLA: An Ultrasound Vision-Language-Action Model for Embodied Abdomina

cs.RO cs.CV ·2026-08-17 ·Cheng Zhang, Xingzheng Wu, Guihao Yan, Xifeng Hu, Zhi Liu +2 more
top venuedatasetcode/data similarity 0.65
Abstract

Artificial intelligence-assisted ultrasound scanning enhances diagnostic reliability and efficiency by providing real-time guidance for standardized image acquisition and reducing operator dependence. However, existing reinforcement learning and learning-assisted ultrasound scanning methods typically rely on carefully designed reward functions or extensive interaction data, which limits their generalization ability and stability across different devices, patient populations, and complex clinical scenarios. To address these challenges, we propose an ultrasound vision-language-action model (US-VLA) for automated ultrasound scanning that explicitly encodes clinical semantic goals and generates sequential probe manipulation actions under real-time ultrasound feedback. In particular, we first design an ultrasound-aware expert fusion module to jointly integrate ultrasound observations with auxiliary contextual information, enabling semantic ultrasound feedback to effectively guide the scanning process. Then, we construct US-VLA-Data, a real-world dataset covering liver and kidney examinations, which includes five clinically defined standard planes and comprises 320 expert scanning trajectories with approximately 80,000 synchronized timesteps. Extensive experiments demonstrate that US-VLA achieves competitive performance in ultrasound probe manipulation tasks, indicating its effectiveness and promising generalization within the evaluated abdominal ultrasound setting. The source code is available at https://github.com/VMVLab/US-VLA.

0.51

MoWE: Spatially Adaptive Mixture-of-Wavelet-Experts Pooling for Ultrasound Lesion Segmentation

cs.CV ·2026-10-18 ·Reaz Hassan Joarder, Sidratul Tanzila Tasmi, Alif Arshad Bakshi, Md. Bakhtiar Hasan, Md Hasanul Kabir
published similarity 0.65
Abstract · Accepted to WACV 2027

We present Mixture-of-Wavelet-Experts (MoWE), a spatially adaptive routing mechanism that replaces max-pooling and strided convolutions in U-Net architectures for ultrasound lesion segmentation. Standard pooling operations suppress high-frequency spatial details, including potential boundary cues in speckled regions. Recent frequency-domain methods preserve some of these details, but a single wavelet family applies the same spectral bias across the image. MoWE instead uses a context-aware router to assign local regions to fixed wavelet families according to local texture and global feature context. The decoder reuses the encoder's spatial routing maps during the inverse transform. Learnable channel-wise gates rescale the high-frequency subbands before reconstruction. We evaluate MoWE with U-Net on four ultrasound lesion benchmarks (BUSI, TN3K, UDIAT, BUS-UCLM) and one cardiac dataset (CAMUS), and with nnU-Net on BUSI. On BUSI, MoWE improves U-Net Dice from 72.59\% to 74.55\% and reduces HD95 from 47.01 to 43.49\,px. With nnU-Net, MoWE improves Dice from 80.18\% to 81.97\% and reduces ASSD from 20.07 to 17.25\,px. On U-Net, MoWE reduces trainable parameters by 6.4\%.

0.26