CS Paper Radar

Initial condition recovery in nonlinear damped viscous photoacoustic tomography using a convolutional neural network-guided gradient-free optimization framework

Madhu Gupta, Anwesa Dey, Prapti Tala, Souvik Roy

cs.LG math.OC ·submitted 2026-10-01 03:58 UTC · v1

Abstract

Photoacoustic tomography (PAT) is a hybrid imaging modality that combines high optical contrast with high ultrasonic resolution for biomedical imaging applications. In this work, we investigate the inverse problem of recovering the initial pressure distribution from boundary measurements in the presence of nonlinear acoustic propagation and viscous attenuation effects. To model these phenomena more accurately, we consider a nonlinear damped viscoelastic wave equation incorporating spatially varying sound speed, temporal attenuation, and nonlinear propagation mechanisms. We first establish the well-posedness of the corresponding forward problem using a Galerkin approximation combined with energy estimates and a fixed-point argument. For the inverse problem, we derive existence, uniqueness, and local uniqueness results under suitable assumptions through a harmonic extension reduction, spectral Laplace transform techniques, and observability estimates. To numerically reconstruct the initial pressure field, we develop a hybrid reconstruction framework that combines a convolutional neural network (CNN) with a gradient-free optimization strategy based on the sequential quadratic Hamiltonian (SQH) method derived from Pontryagin's maximum principle. The CNN is used to generate an informative initial guess, while the SQH framework enforces the governing PDE dynamics during the reconstruction process. Numerical experiments demonstrate that the proposed hybrid strategy significantly improves reconstruction quality, contrast, and robustness compared to standalone time-reversal and CNN-based approaches.

Closest papers

Nearest neighbours by meaning across the whole index.

A hybrid CNN-adjoint optimization framework for reconstruction of viscoelastic tissue properties in magnetic resonance elastography

cs.LG math.OCmath.NA ·2026-10-02 ·Anwesa Dey, Johann Rudi, Elena Cherkaev
similarity 0.73
Abstract

Magnetic resonance elastography (MRE) is a noninvasive imaging modality for quantifying the viscoelastic properties of soft tissues from shear wave propagation. Recovering the complex-valued shear modulus from measured displacement fields leads to a severely ill-posed inverse problem, particularly in the presence of noise and limited boundary excitations. We investigate adjoint-based optimization, convolutional neural network (CNN) reconstruction, and a hybrid framework combining both approaches. The forward model is based on a scalar form of the modified stationary Stokes system with a complex shear modulus. We establish well-posedness of the forward problem, existence of minimizers, and first-order optimality conditions for the adjoint-based formulation, and implement a nonlinear conjugate-gradient method with Armijo line search. While PDE-constrained optimization can accurately refine coefficient reconstructions, its performance depends strongly on initialization. We therefore construct a two-dimensional CNN that maps complex-valued displacement measurements to spatially varying complex shear modulus fields and provides rapid, informative initial reconstructions. The proposed hybrid method uses the CNN reconstruction to initialize the adjoint-based optimization, yielding faster convergence and improved accuracy. The CNN is trained on coefficient fields containing individual perturbations and tested on both individual and previously unseen combined configurations. Numerical experiments demonstrate that the CNN generalizes to these more challenging configurations, while subsequent PDE-constrained optimization further refines the reconstructed coefficient. These results demonstrate the potential of combining data-driven initialization with physics-based optimization for efficient and accurate MRE reconstruction.

0.12

Untrained CNN and coefficient-space regularization for joint reconstruction in photoacoustic tomography

cs.LG math.OC ·2026-10-16 ·Alfio Bozi, Anwesa Dey, Souvik Roy
similarity 0.71
Abstract

The joint reconstruction of the initial pressure and spatially varying sound speed in photoacoustic tomography from boundary measurements is considered. A regularized data-driven framework is proposed in which the unknown fields are represented in finite-dimensional wavelet spaces and fixed nonlinear features generated by an untrained convolutional neural network (CNN) are used to reconstruct the initial-pressure coefficients through Tikhonov-regularized least squares. A learned coefficient-space prior is subsequently used to infer the squared sound-speed coefficients. Numerical experiments demonstrate accurate reconstruction on held-out data and strong generalization to previously unseen phantom geometries. The frozen reconstruction map also remains stable under measurement noise not represented during training, with only minor changes in reconstruction accuracy for noise levels up to $10\%$. In comparison with the supervised trained-CNN approach considered in this work, the untrained representation yields substantially smaller reconstruction errors while requiring approximately one-sixth of the computational time. These results demonstrate that fixed random convolutional features combined with regularized coefficient-space learning provide an efficient and robust approach to joint reconstruction in photoacoustic tomography.

0.11

PAGS: Autofocusing Photoacoustic Tomography via Speed-of-Sound-Adaptive Gaussian Splatting

cs.CV physics.med-ph ·2026-08-26 ·Jiarui Ge, Jintao Ma, Bangxu Fan, Jinyan Zhang, Xiaokang Yang +2 more
unusual similarity 0.62
Abstract · 13 pages, 6 figures

Photoacoustic computed tomography (PACT) combines optical absorption contrast with acoustic detection for high-resolution deep-tissue imaging. A persistent challenge is that unknown speed-of-sound (SoS) heterogeneity changes acoustic time-of-flight, causing defocusing artifacts when reconstruction assumes a uniform SoS. Existing SoS-adaptive methods either rely on calibrated acoustic priors or optimize dense physical medium models, which becomes expensive and difficult to scale in 3D. We propose PAGS, a differentiable framework for blind autofocusing PACT via speed-of-sound-adaptive Gaussian splatting. PAGS represents the initial pressure field with sparse Gaussian photoacoustic (PA) sources and replaces explicit medium recovery with a compact anisotropic path-averaged SoS (ASoS) field parameterized by spherical harmonic probes. This latent propagation field directly controls source-to-transducer arrival-time alignment, while an analytic Gaussian acoustic projection maps the source representation to transducer signals efficiently. The resulting closed-loop signal-domain optimization jointly updates the Gaussian PA source parameters and the ASoS field from measured data, without calibrated SoS priors. Experiments on simulated and physical phantom data demonstrate improved reconstruction sharpness under heterogeneous acoustic media, robustness to sparse-view sampling, and computational benefits from the analytic Gaussian projection.

0.28

Solving the Nonlinear Westervelt Equation in Ultrasound Propagation Using Physics-Informed Neural Networks

cs.LG math.APcs.NE ·2026-11-03 ·Luke Oluwaseye Joel
similarity 0.62
Abstract · 17 pages, 21 figures

Modeling the nonlinear acoustic wave propagation in biological tissues needs accuracy, especially in ultrasound imaging and therapeutic applications. The 1D Westervelt equation, \( p_{xx} - p_{tt} + γ\, p_{ttt} + η\,(p^{2})_{tt}=0, \) could be used to describe a finite-amplitude ultrasound propagation in these tissues. This equation accounts for nonlinearity, \(η\), and attenuation, \(γ\). To solve this equation, we observe that traditional solvers may struggle to do so correctly. This is due to the difficulties arising from the nonlinear nature of the equation. We solve the equation by defining three synthetic cases - linear (\(η=0.001\), \(γ=10^{-6}\)), shock-dominated (\(η=0.02\), \(γ=10^{-6}\)), and dissipation-dominated (\(η=0.01\), \(γ=5\times10^{-4}\)) - and using Physics-Informed Neural Networks (PINNs) to showcase the solution. A sinusoidal activation function is used to capture the oscillatory behavior of the problem. The results of our study, with PDE residual converging to at least \(10^{-6}\), boundary condition loss to \(10^{-5}\), and the PINN loss converging to \(10^{-5}\) for each case at \(30,000\) epochs, show that \(γ\) scales the rate of amplitude decay, while \(η\) governs frequency-dependent phase speeds.

0.27

Deep preferential evolution guided by pairwise comparisons enables motion correction in photoacoustic tomography

eess.SP physics.med-ph ·2026-10-08 ·Karteekeya Sastry, Yousuf Aborahama, Junhao Zhu, Manxiu Cui, Lihong V. Wang
similarity 0.59
Abstract

Motion artifacts in three-dimensional photoacoustic tomography (PAT), caused by extended mechanical scanning of sparse arrays, degrade image quality. Since sparse sampling results in low-quality sub-reconstructions, tracking motion directly is challenging. While final image quality could in principle guide artifact correction, conventional regularizers do not accurately reflect photoacoustic image quality. Here, we introduce deep preferential evolution (DPE), a derivative-free optimization framework where a learned image comparator guides evolutionary search over reconstruction parameters. By learning relative quality differences between same-target image pairs rather than absolute quality scores, the comparator generalized more robustly from simulation to in-vivo images (after unlabeled domain calibration) than an absolute scorer. Comparator-based DPE successfully corrected synthetic motion across diverse anatomies and backgrounds, and it mitigated artifacts from natural, unconstrained motion in human palm images. These results demonstrate that pairwise learned comparison can provide a transferable optimization objective for high-dimensional image restoration when labeled experimental training data are scarce.

0.37

Differentiable Inverse Rendering Recovers Intrinsic Properties from Intravascular Optical Coherence Tomography

cs.CV eess.IVphysics.med-phphysics.optics ·2026-11-09 ·Ajay Manicka, Karim Kadry, Sebastian Ruiz-Lopera, Maryam Alsharqi, Sanjana Arji +5 more
similarity 0.57
Abstract · 27 Pages, 6 Figures, Under Review

Medical images encode intrinsic tissue properties that indicate disease progression, yet these properties remain entangled with the system-dependent physics of image formation. Differentiable inverse rendering asks whether they are recoverable by inverting the imaging system's forward physics rather than through post-hoc correction. We address this in optical coherence tomography (OCT), focusing on the optical attenuation coefficient, a per-pixel marker of pathology and cellular composition. Conventional recovery relies on closed-form inversions limited to simplified light-tissue models, or learned methods coupled to specific imaging configurations. We instead recover per-pixel attenuation from a single OCT image by gradient descent through a differentiable physics-based forward model. We verified the method against analytical solutions, validated it on five in vitro phantoms, and applied it without modification to 29{,}269 clinical intravascular OCT images from 128 patients. The inversion needs no training data or segmentations and is portable across platforms and retrospective archives. Replacing the forward model or recovering another optical parameter leaves the optimization procedure unchanged. We demonstrate per-pixel recovery is tractable because gradient information scales to this high-dimensional problem, where gradient-free methods become intractable. Our work supports quantitative tissue characterization from OCT images and provides a framework for extension across imaging modalities and organ systems.

0.26

Scalable photoacoustic tomography implementations accounting for the spatial impulse response of transducers

eess.IV ·2026-09-24 ·Trung-Thai Do, Paul Escande, Caroline Chaux, Jérôme Gateau, Hwee Kuan Lee
code/data similarity 0.57
Abstract

Iterative model-based reconstruction in photoacoustic tomography repeatedly applies the forward operator mapping the initial pressure to the transducer signals, and its adjoint. At the scale of current three-dimensional systems, this operator cannot be stored and must be evaluated matrix-free, while accounting for the finite, focused surface of the transducers, whose spatial impulse response degrades the resolution when ignored. Representing the initial pressure by compactly supported radial functions, we show that the measured signal is exactly a temporal convolution between a system kernel gathering the radial function and the electrical impulse response, and a purely geometric quantity accounting for the portion of the transducer surface reached by the wave emitted from a voxel during one time step. Two implementations are proposed, differing only in how this quantity is evaluated: a quadrature over points of the surface, as in existing works, or a closed-form area, which never discretizes the surface. We derive closed forms for planar and cylindrically focused transducers and provide, in the latter case, two accelerations of the resulting elliptic integrals, a lookup table and a trapezoidal approximation, together with the piecewise planar approximation customary in the literature. These implementations reduce the per-voxel geometric computations and are released as an open-source Python package for graphics processing units. The performance of these operators is first demonstrated on a synthetic phantom, where the lookup-table-based operator reaches the accuracy of the exact evaluation ten times faster and outperforms the point discretization on both accuracy and runtime. A second experiment shows that they enable the processing of a realistic vascular phantom at full scale, with a higher peak signalto-noise ratio and a better resolution than the back-projection counterpart. The released implementations are an important step towards the adoption of three-dimensional modelbased photoacoustic reconstructions with finite and focused transducers.

0.30

Reconstructing the Vocal Tract with Differentiable Acoustic Simulation

cs.SD cs.CLeess.AS ·2026-09-29 ·Eric Ming Chen, Jin Woo Lee, Vincent Sitzmann
top venue similarity 0.57
Abstract · Accepted as NeurIPS 2026 spotlight paper. Supplementary material at https://people.csail.mit.edu/echen/vocal_recon/

The vocal tract is the region of the human body responsible for filtering one's voice to create speech. In this paper, we present a differentiable and GPU accelerated acoustic simulator for the vocal tract. The differentiable simulator synthesizes speech by propagating sound along an acoustic tube model of the vocal tract, and via its gradients, can solve the inverse problem: reconstructing the shape of the vocal tract solely from the sound it produces. Although the inverse mapping between geometry and sound is notoriously non-convex, we discover that gradient descent succeeds with three technical contributions: (1) we design a frequency domain formulation of the vocal tract's fluid dynamics that is 70x more GPU parallelizable than finite differences in time, (2) we integrate a differentiable model for turbulence to synthesize consonants, and (3) similar to prior work in implicit neural representations (INRs) and neural fields, we find that parameterizing the geometry with a neural network accelerates convergence and escapes local minima that trap discrete representations. Because the simulator is differentiable, it is readily integrated with other deep learning pipelines to enable novel linguistics and medical imaging applications. (1) We demonstrate self-supervised autoencoding of vocal tract shapes across 11 languages, and (2) we couple our simulator with a generative model of MRI (magnetic resonance imaging) images to reconstruct one's moving vocal tract from only their speech without paired data.

0.50