CS Paper Radar

Scalable photoacoustic tomography implementations accounting for the spatial impulse response of transducers

Trung-Thai Do, Paul Escande, Caroline Chaux, Jérôme Gateau, Hwee Kuan Lee

eess.IV ·submitted 2026-09-24 08:56 UTC · v1
code/data

Abstract

Iterative model-based reconstruction in photoacoustic tomography repeatedly applies the forward operator mapping the initial pressure to the transducer signals, and its adjoint. At the scale of current three-dimensional systems, this operator cannot be stored and must be evaluated matrix-free, while accounting for the finite, focused surface of the transducers, whose spatial impulse response degrades the resolution when ignored. Representing the initial pressure by compactly supported radial functions, we show that the measured signal is exactly a temporal convolution between a system kernel gathering the radial function and the electrical impulse response, and a purely geometric quantity accounting for the portion of the transducer surface reached by the wave emitted from a voxel during one time step. Two implementations are proposed, differing only in how this quantity is evaluated: a quadrature over points of the surface, as in existing works, or a closed-form area, which never discretizes the surface. We derive closed forms for planar and cylindrically focused transducers and provide, in the latter case, two accelerations of the resulting elliptic integrals, a lookup table and a trapezoidal approximation, together with the piecewise planar approximation customary in the literature. These implementations reduce the per-voxel geometric computations and are released as an open-source Python package for graphics processing units. The performance of these operators is first demonstrated on a synthetic phantom, where the lookup-table-based operator reaches the accuracy of the exact evaluation ten times faster and outperforms the point discretization on both accuracy and runtime. A second experiment shows that they enable the processing of a realistic vascular phantom at full scale, with a higher peak signalto-noise ratio and a better resolution than the back-projection counterpart. The released implementations are an important step towards the adoption of three-dimensional modelbased photoacoustic reconstructions with finite and focused transducers.

Closest papers

Nearest neighbours by meaning across the whole index.

PAGS: Autofocusing Photoacoustic Tomography via Speed-of-Sound-Adaptive Gaussian Splatting

cs.CV physics.med-ph ·2026-08-26 ·Jiarui Ge, Jintao Ma, Bangxu Fan, Jinyan Zhang, Xiaokang Yang +2 more
unusual similarity 0.67
Abstract · 13 pages, 6 figures

Photoacoustic computed tomography (PACT) combines optical absorption contrast with acoustic detection for high-resolution deep-tissue imaging. A persistent challenge is that unknown speed-of-sound (SoS) heterogeneity changes acoustic time-of-flight, causing defocusing artifacts when reconstruction assumes a uniform SoS. Existing SoS-adaptive methods either rely on calibrated acoustic priors or optimize dense physical medium models, which becomes expensive and difficult to scale in 3D. We propose PAGS, a differentiable framework for blind autofocusing PACT via speed-of-sound-adaptive Gaussian splatting. PAGS represents the initial pressure field with sparse Gaussian photoacoustic (PA) sources and replaces explicit medium recovery with a compact anisotropic path-averaged SoS (ASoS) field parameterized by spherical harmonic probes. This latent propagation field directly controls source-to-transducer arrival-time alignment, while an analytic Gaussian acoustic projection maps the source representation to transducer signals efficiently. The resulting closed-loop signal-domain optimization jointly updates the Gaussian PA source parameters and the ASoS field from measured data, without calibrated SoS priors. Experiments on simulated and physical phantom data demonstrate improved reconstruction sharpness under heterogeneous acoustic media, robustness to sparse-view sampling, and computational benefits from the analytic Gaussian projection.

0.28

Initial condition recovery in nonlinear damped viscous photoacoustic tomography using a convolutional neural network-guided gradient-free optimization framework

cs.LG math.OC ·2026-10-01 ·Madhu Gupta, Anwesa Dey, Prapti Tala, Souvik Roy
similarity 0.57
Abstract

Photoacoustic tomography (PAT) is a hybrid imaging modality that combines high optical contrast with high ultrasonic resolution for biomedical imaging applications. In this work, we investigate the inverse problem of recovering the initial pressure distribution from boundary measurements in the presence of nonlinear acoustic propagation and viscous attenuation effects. To model these phenomena more accurately, we consider a nonlinear damped viscoelastic wave equation incorporating spatially varying sound speed, temporal attenuation, and nonlinear propagation mechanisms. We first establish the well-posedness of the corresponding forward problem using a Galerkin approximation combined with energy estimates and a fixed-point argument. For the inverse problem, we derive existence, uniqueness, and local uniqueness results under suitable assumptions through a harmonic extension reduction, spectral Laplace transform techniques, and observability estimates. To numerically reconstruct the initial pressure field, we develop a hybrid reconstruction framework that combines a convolutional neural network (CNN) with a gradient-free optimization strategy based on the sequential quadratic Hamiltonian (SQH) method derived from Pontryagin's maximum principle. The CNN is used to generate an informative initial guess, while the SQH framework enforces the governing PDE dynamics during the reconstruction process. Numerical experiments demonstrate that the proposed hybrid strategy significantly improves reconstruction quality, contrast, and robustness compared to standalone time-reversal and CNN-based approaches.

0.29

Untrained CNN and coefficient-space regularization for joint reconstruction in photoacoustic tomography

cs.LG math.OC ·2026-10-16 ·Alfio Bozi, Anwesa Dey, Souvik Roy
similarity 0.52
Abstract

The joint reconstruction of the initial pressure and spatially varying sound speed in photoacoustic tomography from boundary measurements is considered. A regularized data-driven framework is proposed in which the unknown fields are represented in finite-dimensional wavelet spaces and fixed nonlinear features generated by an untrained convolutional neural network (CNN) are used to reconstruct the initial-pressure coefficients through Tikhonov-regularized least squares. A learned coefficient-space prior is subsequently used to infer the squared sound-speed coefficients. Numerical experiments demonstrate accurate reconstruction on held-out data and strong generalization to previously unseen phantom geometries. The frozen reconstruction map also remains stable under measurement noise not represented during training, with only minor changes in reconstruction accuracy for noise levels up to $10\%$. In comparison with the supervised trained-CNN approach considered in this work, the untrained representation yields substantially smaller reconstruction errors while requiring approximately one-sixth of the computational time. These results demonstrate that fixed random convolutional features combined with regularized coefficient-space learning provide an efficient and robust approach to joint reconstruction in photoacoustic tomography.

0.11

UltraDiff: Differentiable Ray Tracing in Ultrasound for Shape Optimization

cs.GR cs.CV ·2026-10-06 ·Felix Duelmer, Magdalena Wysocki, Nassir Navab, Mohammad Farid Azampour
top venuehot direction similarity 0.52
Abstract · 4 pages, 4 figures, 1 table. Accepted at SIGGRAPH Asia 2026 Technical Communications

Physically-based differentiable rendering enables gradient-based optimization of scene parameters by matching rendered images to measurements, but has so far mainly focused on light transport. We extend this paradigm to medical ultrasound, where image formation resembles transient rendering: echoes are binned by time-of-flight rather than projected onto an image plane. We present UltraDiff, a modular framework for differentiable ultrasound ray tracing. UltraDiff formulates ultrasound image formation as a path-space integral, gated by travel time between the transducer and tissue interfaces, and derives a Monte Carlo estimator of both the forward model and its gradients with respect to scene parameters. We demonstrate this on an inverse geometry estimation: starting from a sphere, an SDF is optimized until simulated echoes match measured ones, recovering vertebral surfaces from simulated B-mode sweeps and from a real robotic acquisition of a spine phantom. Unlike state-of-the-art ultrasound shape reconstruction methods, which rely on pre-segmented images, our approach operates unsupervised on B-mode images through analysis-by-synthesis, while achieving competitive geometric accuracy. Implemented on top of Mitsuba 3, UltraDiff brings differentiable path tracing to a new sensing modality and provides a foundation for inverse problems in acoustic imaging.

0.47

UltraVoxelGS: Voxel-First Feed-Forward Gaussian Splatting for 3D Ultrasound Reconstruction

cs.CV eess.SP ·2026-11-09 ·Yue Wang, Haoxin Chen, Xiaoqing Guo
code/data similarity 0.51
Abstract

We present UltraVoxelGS, a 3D ultrasound reconstruction method that achieves both fast reconstruction and physically faithful rendering for the first time, bringing live spatial feedback during 2D ultrasound scanning within reach. This is made possible by a feed-forward design that predicts a complete Gaussian scene representation from posed ultrasound images directly, entirely bypassing the per-scene optimization bottleneck that has confined prior methods to offline use. Realising such feed-forward prediction in this setting is non-trivial: unlike natural images, ultrasound slices share at most one-dimensional intersections and exhibit view-dependent appearance due to acoustic propagation and attenuation, violating the dense overlap and photometric consistency assumed by existing feed-forward Gaussian methods. Hence, to achieve fast reconstruction, we introduce a feed-forward voxel-to-Gaussian pass that decouples representation size from input count by lifting all posed slices into a fixed-size voxel support and predicting Gaussian parameters directly. For faithful rendering, we propose ultrasound-aware appearance rendering strategy factorize reflection from cumulative attenuation during training and exploit appearance continuity among spatially adjacent slices for efficient Render-time Appearance Adaptation. On both real-world and simulated datasets, UltraVoxelGS achieves best PSNR/SSIM compared with per-scene optimization baselines while reducing inference from 10-20 minutes to approximately 10 seconds (over 35 times faster) and scales to sequences exceeding 1,000 frames. Code is available at https://github.com/YuebyYue/UltraVoxelGS-camera-ready.

0.30

Common Offset Gathers for Efficient Multistatic Beamforming in Frequency Domain

eess.SP physics.med-ph ·2026-10-29 ·Marko Jakovljevic, Xiaohong Wang, Ion Candel, Anthony E. Samir, Kai Thomenius
similarity 0.48
Abstract · 11 pages

Frequency-domain beamformers reconstruct ultrasound images with far fewer operations than delay-and-sum (DAS). However, for multistatic synthetic aperture data, they require Fourier transforms over the full transmit-receive aperture and large amounts of memory, limiting their use for volumetric imaging. Here, we adapt common offset gathers (COG) from seismic imaging to frequency-domain beamforming: transmit-receive pairs with the same offset are beamformed independently using a bistatic formulation, holding only one offset gather in memory at a time. We combine COG with the range-Doppler algorithm (RDA) and evaluate COG RDA against DAS and conventional multistatic RDA using simulated, phantom, and in vivo acquisitions. For linear arrays, COG RDA reduced memory requirements by two orders of magnitude relative to conventional RDA and beamformed up to 25x faster than DAS, with comparable image quality. For a 32x32-element matrix array, COG RDA requires only 2-D instead of 4-D Fourier transforms, and reconstructed a volume on a GPU 32x faster and with 67x less energy than DAS. COG RDA makes frequency-domain multistatic beamforming practical for matrix arrays and power-constrained devices.

0.32

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.48
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35

HarmoCore: Functional Latent Diffusion for Sparse Reconstruction of Oscillatory Wave Fields

cs.LG cs.CE ·2026-09-01 ·Lihao Chen, Xinyu Zhang, Panqi Chen, Lei Cheng, Ting Zhang +2 more
similarity 0.47
Abstract · 15pages, 8figures

Reconstructing oscillatory wave fields from scattered sensors is a severely underdetermined inverse problem. Beyond the challenges of general physical-field reconstruction, wave responses are complex-valued, frequency-sensitive, and highly oscillatory, while costly simulation and sensing often leave only extreme-sparse observations. Existing low-rank, operator, and diffusion approaches are largely designed for real-valued, smoother fields; dense pixel-space diffusion is particularly inefficient for oscillatory complex fields and difficult to scale to 3D. We propose HarmoCore, which places a generative prior in a compact, continuous, and structured wave-field latent. HarmoCore represents joint real--imaginary channels with Functional Tucker cores over shared continuous spatial bases, learns a frequency-conditioned core diffusion prior, and performs Diffusion Posterior Sampling directly in core space. At fixed sensor coordinates, the multilinear decoder induces an explicit likelihood guidance operator, avoiding dense pixel-space correction. Optional target-equation residual guidance further promotes physical consistency. Experiments on 2D Helmholtz, 2D synthetic wave fields, and 3D Helmholtz show substantial gains under 1%--2% sensing while remaining practical in three dimensions.

0.16