Common Offset Gathers for Efficient Multistatic Beamforming in Frequency Domain

Marko Jakovljevic, Xiaohong Wang, Ion Candel, Anthony E. Samir, Kai Thomenius

eess.SP physics.med-ph ·submitted 2026-10-29 03:05 UTC · v1

Abstract

Frequency-domain beamformers reconstruct ultrasound images with far fewer operations than delay-and-sum (DAS). However, for multistatic synthetic aperture data, they require Fourier transforms over the full transmit-receive aperture and large amounts of memory, limiting their use for volumetric imaging. Here, we adapt common offset gathers (COG) from seismic imaging to frequency-domain beamforming: transmit-receive pairs with the same offset are beamformed independently using a bistatic formulation, holding only one offset gather in memory at a time. We combine COG with the range-Doppler algorithm (RDA) and evaluate COG RDA against DAS and conventional multistatic RDA using simulated, phantom, and in vivo acquisitions. For linear arrays, COG RDA reduced memory requirements by two orders of magnitude relative to conventional RDA and beamformed up to 25x faster than DAS, with comparable image quality. For a 32x32-element matrix array, COG RDA requires only 2-D instead of 4-D Fourier transforms, and reconstructed a volume on a GPU 32x faster and with 67x less energy than DAS. COG RDA makes frequency-domain multistatic beamforming practical for matrix arrays and power-constrained devices.

Comment
11 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.63
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35

Complementary-Aperture Pulse Sequencing for Fundamental-Band Nonlinearity Parameter Imaging

eess.SP physics.med-ph ·2026-09-19 ·Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila
published similarity 0.59
Abstract · 4 pages, 3 figures, accepted to 22nd International Symposium on Medical Information Processing and Analysis (SIPAIM)

The depletion method (DM) enables the estimation of the acoustic nonlinearity parameter, B/A, in pulse-echo ultrasound using fundamental-band signals from low- and high-pressure acquisitions, but requires accurate knowledge of the acoustic-pressure scaling factor. This requirement limits experimental translation because of the slightly nonlinear scaling between excitation voltage set on the ultrasound system and pressure at the probe. We propose a complementary-aperture pulse sequence (CAPS) that recovers the linearly scaled low-pressure signal by coherently summing RF acquisitions from interleaved transmit subapertures whereas a full-aperture transmission provides the high-pressure signal maintaining the same excitation voltage configured in the ultrasound system. In silico phantoms of a homogeneous sample and a reference evaluated four aperture partitions of CAPS and compared them with the DM under relative scaling-factor errors from 0.01% to 10%. Using the DM, errors of 0.1% and 1% produced absolute B/A biases of up to 27.3% and 58.3%, respectively. CAPS yielded mean B/A values of 8.9 for a prescribed value of 9, with biases of less than 1.3% across all partitions, matching an ideally calibrated DM. These results demonstrate that CAPS preserves depletion-based B/A estimation without using the pressure scaling factor as a reconstruction input, supporting experimental and in vivo implementation without pressure-ratio calibration.

0.32

Laplace-Domain Beamforming for Ultrafast Plane-Wave Imaging

eess.IV physics.med-pheess.SP ·2026-10-06 ·Martin F. Schiffner
theoryunusual similarity 0.58
Abstract · 5 pages, 3 figures, 1 table; submitted to 2026 IEEE International Ultrasonics Symposium (IUS), Raleigh, NC, USA, Oct. 2026

Fourier-domain beamforming methods, such as filtered backpropagation (FBP), are beneficial in ultrafast plane-wave imaging due to their computational efficiency and high image quality. These methods use the Fourier diffraction theorem (FDT) for steered plane waves to exactly invert linear scattering models. However, these models rely on simplifying assumptions that degrade image quality. The use of linear transducer arrays, in particular, requires: (i) a two-dimensional space, and (ii) lossless tissues. Herein, Laplace-domain beamforming is proposed. This method retains the computational efficiency of the Fourier-domain methods while improving image quality for linear arrays. Specifically, the method uses a generalization of the FDT, here called Laplace diffraction theorem, to account for three spatial dimensions, finite array element heights, and lossy tissues. A phantom experiment showed that the proposed method improves image uniformity, spatial resolution, and contrast compared to FBP. Using three steering angles, the lateral and axial -6 dB-widths of wires reduced by up to 12% and 25%, respectively, while the contrast of anechoic regions improved by up to 9%.

0.26

Practical Hardware-Efficient ISAC: Enabling Multi-Target Sensing With Few RF Chains

eess.SP ·2026-10-12 ·Zhenkun Zhang, Cunhua Pan, Hong Ren, Jun Tang, Dongming Wang +1 more
theory similarity 0.58
Abstract

Hybrid analog--digital arrays reduce hardware cost in integrated sensing and communications (ISAC), but spatial compression and beam-dependent scan responses complicate multi-target estimation with few radio-frequency (RF) chains. To address these challenges, this paper proposes a burst beam-scanning multiple-input multiple-output orthogonal frequency-division multiplexing (MIMO-OFDM) framework that reuses downlink reference signals for joint range, radial-velocity, elevation, and azimuth estimation. Specifically, a structured global--local dual-tensor estimator separates targets by using scanning observations and refines their parameters from selected-beam RF-chain responses, with delay--Doppler signatures maintaining cross-stage target correspondence. The recovered subarray responses yield closed-form elevation and azimuth estimates through exact sum--difference relations, avoiding small-angle approximations and fine angular grid searches. To further improve Doppler accuracy, spatial-mask-aided weighted least squares exploits the longer inter-burst temporal aperture while resolving phase ambiguity using intra-burst estimates. The joint multi-target Cramér--Rao lower bound (CRLB) and corresponding three-dimensional (3D) positioning bound are also derived to characterize estimation performance. Simulation results show that the proposed scheme achieves near-CRLB estimation accuracy at high transmit powers and centimeter- to millimeter-level 3D positioning with only four RF chains, while maintaining low computational cost.

0.12

A Reconfigurable Pipelined-SAR ADC with Embedded Compression for Temporal Compressed-Sensing Ultrasound Imaging

eess.SP physics.med-ph ·2026-08-28 ·Reza Pakdaman Zangabad, Xitie Zhang, Levent Degertekin, Shaolan Li
similarity 0.58
Abstract · 15 pages, 11 figures, Journal

Compact ultrasound imaging systems are increasingly constrained by receiver-side sampling, conversion, memory, and data-transfer requirements. This work presents a compressed-sensing pipelined successive-approximation-register analog-to-digital converter (CS-SAR ADC) for acquisition-side temporal compression of pre-beamformed medical ultrasound radio-frequency (RF) data. Pseudo-random polarity modulation and charge-domain accumulation are embedded in the SAR sampling network so that multiple consecutive RF samples are encoded into one measurement before quantization, supporting temporal compression ratios of $N_{cT}=1$, 2, and 4. The compressed outputs are recovered off chip using a probe-specific pulse-dictionary RF model and then processed with conventional ultrasound beamforming. A 65-nm CMOS prototype was measured with a 1.2-V supply and 50-MHz master clock. In the non-compressed mode, it operates at 10 MS/s, consumes 964.49~$μ$W, and achieves 44.12-dB SNDR and 56.40-dB SFDR for a 7.7-kHz input. The ADC output rates decrease to 5 MS/s and 2.5 MS/s for $N_{cT}=2$ and 4. Across all evaluated RF traces, median NCC values were 0.981 and 0.932, with median NRMSE values of 0.36 and 0.56, respectively. Wire-phantom localization error remained below 0.04 mm with no appreciable FWHM degradation. In the speckle-rich cyst phantom, SSIM remained 0.94 and 0.87, while CNR decreased from 3.534 in the reference to 2.047 and 1.379. These results demonstrate a hardware-realistic tradeoff in which temporal compression substantially reduces ADC conversion count and output data rate while preserving point-target geometry, whereas low-contrast cyst conspicuity is more compression-sensitive.

0.28

Beamfocusing Beyond the Near Field: Frequency Diverse Arrays for OFDM-ISAC Systems

cs.NI cs.ITeess.SP ·2026-10-30 ·Arda Akyazi, Ahmed Hussain, Asmaa Abdallah, Ahmed M. Eltawil, Abdulkadir Celik
hot direction similarity 0.57
Abstract · 8 pages, 5 figures. Interactive figures and code: https://akadircelik.com/demos/fda-ofdm-isac/

Traditional phased arrays (PAs) achieve near-field (NF) beamfocusing through spherical wavefront curvature, but lose this range selectivity in the far field (FF). Frequency diverse arrays (FDAs) instead introduce frequency offsets across antenna elements. These offsets synthesize a range-dependent beam whose beamdepth is governed by the aggregate frequency-offset span rather than the physical aperture, thereby extending finite beamdepth into the FF. Although FDAs have been extensively studied for radar, their broader potential for wireless communications remains largely unexplored. Accordingly, this article examines how this capability can support wireless communications and integrated sensing and communication (ISAC). We compare PA and FDA focusing mechanisms, explain FDA coupling and periodicities, and assess coexistence with orthogonal frequency-division multiplexing (OFDM). Integer-multiple offsets preserve alignment with the OFDM subcarrier grid and avoid offset-induced intercarrier interference under ideal synchronization, but require suitable symbol mapping and receiver processing. We also distinguish FDA beamdepth from waveform-based radar range resolution and discuss their complementary roles in sensing. For the configurations studied, FDAs offer no additional single-user spatial degrees of freedom. Interestingly, their principal benefit is multiuser separation through location division multiple access (LDMA). Numerical case studies under an idealized FDA channel model show that FDA-LDMA achieves higher sum-rates than PA-based schemes for users with small angular separation in the FF, even after accounting for the bandwidth reserved for frequency offsets.

0.44

Physics-Guided Multi-Objective Deep Learning for Ultrasound RF Data Interpolation in Resource-Constrained Imaging

eess.IV cs.LG ·2026-09-23 ·Luoyuan Zhang, Yiyang You, Ananya Tandri, Yinan Feng, Hyunwoo Song +2 more
similarity 0.57
Abstract · Submitted to the Journal of Computational Design and Engineering

Ultrasound imaging increasingly targets portable, point-of-care, and wearable settings where constraints on power, bandwidth, and hardware complexity often necessitate sparse data acquisition in spatiotemporal scanning. However, image reconstruction using the sparse data can introduce insufficient phase information in coherent beamforming process, resulting in grating-lobe artifacts that degrade imaging contrast resolution. We present a physics-guided, data-driven framework for sparse-to-dense radio-frequency (RF) reconstruction that aligns training with downstream image formation. Our approach trains an end-to-end interpolation network using a hybrid supervision scheme that combines an RF-domain and a beamforming-domain loss with exponential moving average (EMA) to stabilize the multi-objective training. To improve generalization under variable acquisition layouts, we also introduce a random-skip masking strategy that varies sparsity patterns during training so a single model can handle diverse decimation factors and irregular channel configurations. We evaluate the framework on a held-out test set using the mean structural similarity index measure (SSIM) between reconstructed and ground-truth beamformed images. Across decimation factors $\times 2$ to $\times 13$, the best-performing configuration maintains mean SSIM around 0.95. Overall, the results show consistent gains in RF reconstruction and post-beamforming image quality across diverse acquisition conditions. This approach enables robust, high-quality ultrasound imaging at resource-constrained settings by allowing more sparse scanning in spatiotemporal domain.

0.18

Physics-Grounded Objective-Conditioned Deep Beamforming for Adaptive Resolution-Contrast Control in Plane-Wave Ultrasound Imaging

eess.SP ·2026-10-05 ·Gopika Gopikrishnan, Mahesh Raveendranatha Panicker
similarity 0.56
Abstract

Plane-wave ultrasound enables ultrafast imaging but remains constrained by a receive-aperture-dependent resolution- contrast trade-off. Fine structures benefit from high spatial resolution, whereas diffuse tissue and lesions often require improved contrast and clutter suppression. These objectives favor different receive-aperture configurations, yet conventional beamformers operate at a fixed imaging point. We propose a physics-grounded, objective-conditioned deep beamformer that enables controllable image formation within a single network. From single-plane-wave channel data, the network predicts spatially varying receive-apodization weights, conditioned on the desired imaging objective through feature-wise linear modulation. The conditioning variable is explicitly tied to a physically defined receive-aperture configuration and supervised using the correspondingcoherent-plane-wave-compounding target. Differentiable, region-of-interest-aware, physics-guided quality losses further promote objective-specific resolution and contrast during end-to-end training. The model is trained exclusively on simulated channel data spanning diverse target morphologies and echogenicities, and evaluated zero-shot on the PICMUS and CUBDL datasets, including unseen probe geometries. The proposed framework generally improves upon single-plane-wave delay-and-sum reconstruction while providing objective-dependent control. On PICMUS, the proposed method improves gCNR by up to 16.8% and axial resolution by 22% compared with the reference beamforming method. Moreover, switching between the contrast- and resolution-oriented objectives enables controllable changes of up to 4.9% in lesion contrast and 11.4% in lateral resolution. Compared with the best-performing learning-based baselines, the proposed method reduces lateral full-width-at-half-maximum by 5.9% and improves generalized contrast-to-noise ratio by 6.6%.

0.29