CS Paper Radar

A Reconfigurable Pipelined-SAR ADC with Embedded Compression for Temporal Compressed-Sensing Ultrasound Imaging

Reza Pakdaman Zangabad, Xitie Zhang, Levent Degertekin, Shaolan Li

eess.SP physics.med-ph ·submitted 2026-08-28 20:35 UTC · v1

Abstract

Compact ultrasound imaging systems are increasingly constrained by receiver-side sampling, conversion, memory, and data-transfer requirements. This work presents a compressed-sensing pipelined successive-approximation-register analog-to-digital converter (CS-SAR ADC) for acquisition-side temporal compression of pre-beamformed medical ultrasound radio-frequency (RF) data. Pseudo-random polarity modulation and charge-domain accumulation are embedded in the SAR sampling network so that multiple consecutive RF samples are encoded into one measurement before quantization, supporting temporal compression ratios of $N_{cT}=1$, 2, and 4. The compressed outputs are recovered off chip using a probe-specific pulse-dictionary RF model and then processed with conventional ultrasound beamforming. A 65-nm CMOS prototype was measured with a 1.2-V supply and 50-MHz master clock. In the non-compressed mode, it operates at 10 MS/s, consumes 964.49~$μ$W, and achieves 44.12-dB SNDR and 56.40-dB SFDR for a 7.7-kHz input. The ADC output rates decrease to 5 MS/s and 2.5 MS/s for $N_{cT}=2$ and 4. Across all evaluated RF traces, median NCC values were 0.981 and 0.932, with median NRMSE values of 0.36 and 0.56, respectively. Wire-phantom localization error remained below 0.04 mm with no appreciable FWHM degradation. In the speckle-rich cyst phantom, SSIM remained 0.94 and 0.87, while CNR decreased from 3.534 in the reference to 2.047 and 1.379. These results demonstrate a hardware-realistic tradeoff in which temporal compression substantially reduces ADC conversion count and output data rate while preserving point-target geometry, whereas low-contrast cyst conspicuity is more compression-sensitive.

Comment
15 pages, 11 figures, Journal

Closest papers

Nearest neighbours by meaning across the whole index.

Common Offset Gathers for Efficient Multistatic Beamforming in Frequency Domain

eess.SP physics.med-ph ·2026-10-29 ·Marko Jakovljevic, Xiaohong Wang, Ion Candel, Anthony E. Samir, Kai Thomenius
similarity 0.58
Abstract · 11 pages

Frequency-domain beamformers reconstruct ultrasound images with far fewer operations than delay-and-sum (DAS). However, for multistatic synthetic aperture data, they require Fourier transforms over the full transmit-receive aperture and large amounts of memory, limiting their use for volumetric imaging. Here, we adapt common offset gathers (COG) from seismic imaging to frequency-domain beamforming: transmit-receive pairs with the same offset are beamformed independently using a bistatic formulation, holding only one offset gather in memory at a time. We combine COG with the range-Doppler algorithm (RDA) and evaluate COG RDA against DAS and conventional multistatic RDA using simulated, phantom, and in vivo acquisitions. For linear arrays, COG RDA reduced memory requirements by two orders of magnitude relative to conventional RDA and beamformed up to 25x faster than DAS, with comparable image quality. For a 32x32-element matrix array, COG RDA requires only 2-D instead of 4-D Fourier transforms, and reconstructed a volume on a GPU 32x faster and with 67x less energy than DAS. COG RDA makes frequency-domain multistatic beamforming practical for matrix arrays and power-constrained devices.

0.32

Complementary-Aperture Pulse Sequencing for Fundamental-Band Nonlinearity Parameter Imaging

eess.SP physics.med-ph ·2026-09-19 ·Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila
published similarity 0.56
Abstract · 4 pages, 3 figures, accepted to 22nd International Symposium on Medical Information Processing and Analysis (SIPAIM)

The depletion method (DM) enables the estimation of the acoustic nonlinearity parameter, B/A, in pulse-echo ultrasound using fundamental-band signals from low- and high-pressure acquisitions, but requires accurate knowledge of the acoustic-pressure scaling factor. This requirement limits experimental translation because of the slightly nonlinear scaling between excitation voltage set on the ultrasound system and pressure at the probe. We propose a complementary-aperture pulse sequence (CAPS) that recovers the linearly scaled low-pressure signal by coherently summing RF acquisitions from interleaved transmit subapertures whereas a full-aperture transmission provides the high-pressure signal maintaining the same excitation voltage configured in the ultrasound system. In silico phantoms of a homogeneous sample and a reference evaluated four aperture partitions of CAPS and compared them with the DM under relative scaling-factor errors from 0.01% to 10%. Using the DM, errors of 0.1% and 1% produced absolute B/A biases of up to 27.3% and 58.3%, respectively. CAPS yielded mean B/A values of 8.9 for a prescribed value of 9, with biases of less than 1.3% across all partitions, matching an ideally calibrated DM. These results demonstrate that CAPS preserves depletion-based B/A estimation without using the pressure scaling factor as a reconstruction input, supporting experimental and in vivo implementation without pressure-ratio calibration.

0.32

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.54
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35

Compute Before You Digitize: ADC-less Mixed-Signal Processing for Scalable Cryogenic Qubit Readout

cs.AR quant-phcs.ETeess.SP ·2026-11-17 ·Qirui Zhang, Ben Toby, He Wang, Benjamin Lienhard, David Blaauw +1 more
similarity 0.54
Abstract

We introduce DIRAC, an ADC-less in-cryostat qubit readout architecture that uses analog computing to redraw the analog-digital boundary. Directly operating on the front-end's analog output, passive complex mixers perform the equivalent of digital demodulation, ping-pong active-RC integrators average their outputs into down-sampled per-qubit traces, and a time-domain stage digitizes them, eliminating Nyquist-rate ADCs. A TX-RX co-design derives the mixers' local oscillators from the readout transmitter's baseband rather than per-tone PLLs. A per-line calibration flow trains the matched filter jointly with the neural network, improving fidelity and enabling low-bit-width, low-voltage digital processing. Designed in 22 nm FD-SOI and evaluated at 4 K on 1.12M experimental shots, DIRAC matches the fidelity of a floating-point (FP32) digital pipeline for readout windows down to 750 ns, at 31.6$\times$ and 238$\times$ lower energy than the fixed-point (FxP) and FP32 pipelines. It cuts the total 4 K power per physical qubit by 50.4% and 68.6% relative to FxP and room-temperature flex cables, respectively. At a fixed logical-qubit count and 4 K budget, this yields, against FxP, a code distance larger by 2 to 6 and a 1.6-7.3$\times$ (Willow) and 4.9-204$\times$ (SI1000, $p = 10^{-3}$) lower logical error rate.

0.23

Task-Based Evaluation of Raw Radar Data Compression: A Pre-Registered Study of Where Classical Codecs Fail to Preserve Target Detection, and Why

eess.SP ·2026-08-18 ·Eric Michael Chrabot
code/data similarity 0.53
Abstract · 16 pages, 9 figures, 5 tables. v2: corrects the retention-only counterfactual (Secs. I, III-A, V-C); states the criterion's commit chronolog…

Synthetic aperture radar (SAR) systems collect raw I/Q echo data at rates that exceed downlink capacity; fielded systems compress onboard with block-adaptive quantization (BAQ/FDBAQ). Proposed replacements, including learned compression, are evaluated with image-quality metrics (PSNR, SSIM, SQNR); none measures whether the data still supports its operational use. We introduce a task-based evaluation methodology for raw radar compression, with a published pre-registration trail: codecs are scored after SAR focusing against a two-sided criterion -- a CFAR detection-retention floor and a spurious-detection budget at matched threshold -- using frozen task models trained once on uncompressed data. On Sentinel-1 stripmap Level-0 data the evaluation brackets the fielded FDBAQ operating point at the resolution of the BAQ grid (3-bit BAQ sustains utility at 6.12 bits per complex sample; 2-bit does not), with a reported lattice artifact found to change retention by at most 0.004. Under the final plane-mapping rule no classical configuration sustains utility below 4.86 bits per complex sample on this scene. Energy concentration after focusing delivers the predicted retention gain (0.888 vs 0.691 at 2 bits) but converts it into target-adjacent false alarms for wavelet and block-transform codecs alike: a retention-only rule certifies focused-domain JPEG2000 at 4 bits while it produces 2.5 times the tolerable spurious count. On AFRL Gotcha GMTI data (airborne, never compressed onboard) the frontier is bracketed at 7.4-8.0 bits per complex sample and the same trade reappears; on an Umbra spotlight image JPEG2000 passes the retention floor at 2, 1, and 0.5 bits while producing 10-14 times the spurious budget. We report the full pre-registration trail, including the chronology of the criterion's two clauses, one retracted overclaim, and a bounded negative result for a small learned codec.

0.28

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

eess.SP ·2026-10-09 ·T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer +181 more
dataset similarity 0.53
Abstract · Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

0.47

U-Sonic: An Open-Source 8-Channel Ultrasound Transmit IP in a 130 nm RISC-V SoC

cs.AR eess.SP ·2026-10-01 ·Federico Villani, Nico Canzani, Marc-André Wessner, Philippe Sauter, Enrico Zelioli +3 more
published similarity 0.53
Abstract · 4 pages, 3 figures, 3 tables. This work has been accepted for publication in the 2026 IEEE International Ultrasonics Symposium (IUS) proceed…

Miniaturized ultrasound (US) probes require programmable and synchronized transmit (TX) excitation across multiple elements, while existing compact platforms often rely on limited microcontroller (MCU) pulse generators or closed-source fixed-function pulser devices. We present U-Sonic, an open-source digital US TX peripheral integrated into a 32-bit RISC-V system-on-chip (SoC). The implemented SoC integrates 8 pulser cores, while the parameterized architecture supports up to 16 channels. Each core generates single- or dual-tone bursts with programmable period, duty cycle, pulse count, polarity, and idle level, together with optional inverted stop pulses for active damping. A shared memory-mapped Open Bus Interface (OBI) enables synchronous start and stop of arbitrary channel subsets and supports composite bipolar, gated, and three-level excitation schemes. Functional correctness was verified in Verilator against a Python golden model over 4379 checked cycles across directed and randomized configurations, and confirmed on a Terasic DE10-Lite field-programmable gate array (FPGA). The design was synthesized and placed-and-routed in IHP 130 nm. The post-layout area in kilo gate equivalents (kGE), scales as 1.65 kGE plus 1.66 kGE per channel. The 8-channel instance occupies 14.9 kGE, corresponding to approximately 14.3% of the 104 kGE SoC. The register-transfer level (RTL), register descriptions, verification collateral, and software support are released as open source.

0.50

A Timing-Robust Frequency-Interleaved ADC with Embedded Analog Fourier Transform

eess.SP ·2026-10-02 ·Xingchen Chao, Yunqiang Xu, Qiang Yu, Christian Adam, Qiang Li
similarity 0.52
Abstract

Timing errors represent a fundamental challenge in high-speed analog-to-digital converters (ADCs). This paper presents a frequency-interleaved architecture with inherent robustness to timing errors. The frequency interleaving is achieved by an embedded analog Fourier transform (AFT), allowing accurate channel spacing. The charge-based passive AFT is able to share the capacitor array with the capacitive DAC of the subsequent data conversion. A circuit implementation for the complex-valued irrational coefficients in the AFT matrix is proposed, which eliminates the device-ratio-induced systematic errors. Measured at 10b 13GS/s, the calibration-free ADC achieves 45.8-dB SNDR and 56.1-dB SFDR at Nyquist. The ADC consumes 26.4mA from a single 1V supply, resulting in a Walden FoM of 12.7 fJ/conv.-step.

0.25