CS Paper Radar

U-Sonic: An Open-Source 8-Channel Ultrasound Transmit IP in a 130 nm RISC-V SoC

Federico Villani, Nico Canzani, Marc-André Wessner, Philippe Sauter, Enrico Zelioli, Andrea Cossettini, Christoph Leitner, Luca Benini

cs.AR eess.SP ·submitted 2026-10-01 12:48 UTC · v1
published

Abstract

Miniaturized ultrasound (US) probes require programmable and synchronized transmit (TX) excitation across multiple elements, while existing compact platforms often rely on limited microcontroller (MCU) pulse generators or closed-source fixed-function pulser devices. We present U-Sonic, an open-source digital US TX peripheral integrated into a 32-bit RISC-V system-on-chip (SoC). The implemented SoC integrates 8 pulser cores, while the parameterized architecture supports up to 16 channels. Each core generates single- or dual-tone bursts with programmable period, duty cycle, pulse count, polarity, and idle level, together with optional inverted stop pulses for active damping. A shared memory-mapped Open Bus Interface (OBI) enables synchronous start and stop of arbitrary channel subsets and supports composite bipolar, gated, and three-level excitation schemes. Functional correctness was verified in Verilator against a Python golden model over 4379 checked cycles across directed and randomized configurations, and confirmed on a Terasic DE10-Lite field-programmable gate array (FPGA). The design was synthesized and placed-and-routed in IHP 130 nm. The post-layout area in kilo gate equivalents (kGE), scales as 1.65 kGE plus 1.66 kGE per channel. The 8-channel instance occupies 14.9 kGE, corresponding to approximately 14.3% of the 104 kGE SoC. The register-transfer level (RTL), register descriptions, verification collateral, and software support are released as open source.

Comment
4 pages, 3 figures, 3 tables. This work has been accepted for publication in the 2026 IEEE International Ultrasonics Symposium (IUS) proceedings. The final published version will be available via IEEE Xplore

Closest papers

Nearest neighbours by meaning across the whole index.

Open-Source Live-Reconfigurable Multi-Mode Wearable Ultrasound

eess.SP cs.AR ·2026-10-01 ·Cédric Hirschi, Federico Villani, Luca Benini, Andrea Cossettini
publishedunusual similarity 0.57
Abstract · 4 pages, 4 figures, 1 table. This work has been accepted for publication in the 2026 IEEE International Ultrasonics Symposium (IUS) proceedi…

Wearable ultrasound enables continuous deep-tissue monitoring, and a single programmable probe can operate in multiple complementary modes, such as structural A-mode and Doppler flow measurement. However, each operating mode requires dedicated measurement parameters and peripheral states, with no single configuration serving all modes on resource-constrained devices. Time multiplexing of operating modes introduces reconfiguration latency that lowers the effective mode repetition rate. To address this limitation, we present an open-source, transition-aware control stack for low-latency, in-session reconfiguration of the 32-channel TinyProbe wearable platform. Operating modes are described as hardware configurations, and host-side shadow registers track the peripheral states, enabling transition-specific register updates. Transition sequences are executed either by the host (over Wi-Fi 6) or by a firmware loop on the probe MCU. We validate the stack on a pulsatile-flow phantom by interleaving blocks of 25 to 100 pulsed-wave Doppler shots at 1.43 kHz PRF with single 16-channel A-mode acquisitions, changing channel configurations at every transition. Compared to full reconfiguration, the overhead per transition decreases from 30.2 ms to 11.6 ms (host-scheduled) and 3.1 ms (MCU-scheduled). For 75-shot Doppler blocks, the multi-mode repetition rate reaches 16.0 Hz (MCU-scheduled), 90.1% of the theoretical maximum of 17.7 Hz. Concurrent reconstruction of a Doppler spectrogram and a lumen-diameter trace demonstrates the functionality of time-multiplexed flow and structural monitoring.

0.56

Open-Source Multi-Wire SPI Readout for Wearable Ultrasound Probes

cs.AR eess.SP ·2026-10-01 ·Federico Villani, Soumyo Bhattacharjee, Lisa Odermatt, Cédric Hirschi, Luca Benini +1 more
published similarity 0.55
Abstract · 4 pages, 3 figures. This work has been accepted for publication in the 2026 IEEE International Ultrasonics Symposium (IUS) proceedings. The …

Wearable ultrasound probes must transfer increasingly large acquisition payloads while maintaining compact, low-power electronics. In TinyProbe, the current bottleneck in data transfer occurs between the acquisition FPGA and the wireless system controller. This work presents an open-source, multi-wire SPI readout interface that uses serial command and address phases followed by a build-time-selectable dual- or quad-lane payload phase that is intended to address this bottleneck by increasing the potential bandwidth over the wifi limit while retaining compatibility with the Microcontroller-centric wearable US architecture. The interface emulates a serial flash memory, enabling compatibility with a broad range of microcontroller families and their existing peripheral interfaces. On the FPGA, the data path connects the existing acquisition FIFOs to the SPI interface through clock-domain crossing, sample reshaping, and packing into 32-bit words. Dual-SPI readout is integrated into the existing IGLOO2/SiWG917 TinyProbe architecture and verified at an SCLK frequency of 5 MHz. A separate Kria K26 testbed is used to characterize the FPGA SPI interface independently of the acquisition and wireless subsystems, demonstrating error-free transfers at SCLK frequencies up to 66 MHz. These measurements identify the SiWG917 multi-lane SPI implementation as the next bandwidth-limiting component and motivate a future upgrade of the system controller. The HDL and MCU implementations are released under a permissive open-source license.

0.50

A single-precision floating-point systolic Givens-QRD Triangular Solver for MVDR Beamforming

cs.AR eess.SP ·2026-09-02 ·Athi Ram R S, Alwin A, S. G. Sreejeesh, J. U. Kidav
similarity 0.54
Abstract · 18 pages, 14 figures, 18 tables

Computation of adaptive beamforming weights in Minimum Variance Distortionless Response (MVDR) processing is a latency-critical operation that poses significant challenges for real-time hardware implementation. This paper presents an FPGA implementation of a systolic Givens-rotation QR decomposition pipeline for MVDR beamforming on a simulated 32-element ultrasound transducer array, using single-precision floating-point arithmetic. The design is deployed on a Zynq UltraScale+ FPGA at 100 MHz with three parallel kernel instances operating concurrently, achieving a measured throughput of 31,123 weight vectors/s at 90.9% parallel efficiency relative to the measured single-instance rate. At an estimated 2.451 W of programmable-logic power, and 5.286 W including the processing system, this corresponds to 12,698 and 5,888 weight vectors/s/W, respectively. Under a matched three-way dispatch, a 24-core Intel Xeon Gold 5220R at 2.20 GHz achieves 465,699 weight vectors/s at a measured 83.08 W package power, corresponding to 5,606 weight vectors/s/W. The FPGA therefore attains 2.3x the power-normalised throughput of the processor on a programmable-logic basis and 1.05x on a total on-chip basis. In contrast, the processor retains a raw throughput advantage of approximately 15x at this operating point. Numerical precision is validated against MATLAB float32 reference outputs from a Field II cyst phantom simulation, achieving a 100% pass rate with a root mean square error of 5.10x10^-7, confirming near-theoretical finite-precision behaviour without systematic bias.

0.38

A Reconfigurable Pipelined-SAR ADC with Embedded Compression for Temporal Compressed-Sensing Ultrasound Imaging

eess.SP physics.med-ph ·2026-08-28 ·Reza Pakdaman Zangabad, Xitie Zhang, Levent Degertekin, Shaolan Li
similarity 0.53
Abstract · 15 pages, 11 figures, Journal

Compact ultrasound imaging systems are increasingly constrained by receiver-side sampling, conversion, memory, and data-transfer requirements. This work presents a compressed-sensing pipelined successive-approximation-register analog-to-digital converter (CS-SAR ADC) for acquisition-side temporal compression of pre-beamformed medical ultrasound radio-frequency (RF) data. Pseudo-random polarity modulation and charge-domain accumulation are embedded in the SAR sampling network so that multiple consecutive RF samples are encoded into one measurement before quantization, supporting temporal compression ratios of $N_{cT}=1$, 2, and 4. The compressed outputs are recovered off chip using a probe-specific pulse-dictionary RF model and then processed with conventional ultrasound beamforming. A 65-nm CMOS prototype was measured with a 1.2-V supply and 50-MHz master clock. In the non-compressed mode, it operates at 10 MS/s, consumes 964.49~$μ$W, and achieves 44.12-dB SNDR and 56.40-dB SFDR for a 7.7-kHz input. The ADC output rates decrease to 5 MS/s and 2.5 MS/s for $N_{cT}=2$ and 4. Across all evaluated RF traces, median NCC values were 0.981 and 0.932, with median NRMSE values of 0.36 and 0.56, respectively. Wire-phantom localization error remained below 0.04 mm with no appreciable FWHM degradation. In the speckle-rich cyst phantom, SSIM remained 0.94 and 0.87, while CNR decreased from 3.534 in the reference to 2.047 and 1.379. These results demonstrate a hardware-realistic tradeoff in which temporal compression substantially reduces ADC conversion count and output data rate while preserving point-target geometry, whereas low-contrast cyst conspicuity is more compression-sensitive.

0.28

uhd-rfsoc: Bringing Off-the-Shelf RFSoC Boards to Unmodified UHD Applications

cs.NI cs.AReess.SP ·2026-11-13 ·Wei Cheng, Yiming Li, Junyao Zheng, Cheng-Bin Chen, Tingjun Chen
code/data similarity 0.50
Abstract

Next-generation wireless research relies on software-defined radios (SDRs) with more channels and larger bandwidth. The USRP family is one of the most widely used SDR platforms, and much of the wireless software ecosystem is built on top of the USRP hardware driver (UHD). However, each USRP model comes with a fixed channel count, bandwidth, and streaming capability. Off-the-shelf radio frequency system-on-chip (RFSoC) boards, on the other hand, integrate up to 16 analog-to-digital converters (ADCs) and 16 digital-to-analog converters (DACs) operating at several gigasamples per second (GS/s), but existing UHD applications cannot directly use them. We present uhd-rfsoc, an open-source FPGA design and host software stack that turns these boards, including the 16-channel ZCU216 and the RFSoC 4x2, into standard UHD devices without modifying UHD. Through standard UHD calls, applications can configure the carrier frequency, channel count, the per-channel I/Q sample rate, and the wire format. uhd-rfsoc combines timestamped, flow-controlled sample transport in the FPGA with data plane development kit (DPDK) packet processing and vectorized sample conversion on x86 and Arm hosts. The built bitstreams for a number of RFSoC board configurations with varying RF data converter rates, channel counts, I/Q sample rates, and wire formats all successfully pass UHD's built-in streaming benchmarks. We further demonstrate compatibility with unmodified GNU Radio flowgraphs, a custom GPU-accelerated transceiver digital signal processing pipeline, as well as the OCUDU and Duranta 5G radio access network stacks using both software and commodity user equipment.

0.35

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

eess.SP ·2026-10-09 ·T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer +181 more
dataset similarity 0.50
Abstract · Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

0.47

FIREQ: FPGA Instrumentation for Readout and Qubit control

eess.SY quant-ph ·2026-08-29 ·Giuseppe La Capra, Fabio Calabrese, Giorgio D'Amico, Christian Conti, Andrea De Simone +6 more
code/data similarity 0.49
Abstract · 15 pages, 9 figures

We present FIREQ (FPGA Instrumentation for Readout and Qubit control), an open-source RFSoC-based framework for the control and readout of superconducting qubits. FIREQ combines a modular AXI-compliant firmware architecture with a PYNQ-based software stack designed to support extensible hardware integration, deterministic experiment timing, and low-overhead execution of repeated calibration and characterization workflows. The firmware implements direct RF synthesis and acquisition, trigger-based sequencing, programmable pulse generation, frequency-multiplexed readout, and memory-efficient acquisition and waveform buffering. The software adopts a client-server architecture with streamed data transfer and dependency-aware configuration updates to reduce host-device and reconfiguration overhead during parameter sweeps. On an AMD Zynq UltraScale+ RFSoC ZCU216, FIREQ generates RF pulses up to 9.3 GHz with a pulse-duration resolution of 107 ps and an event-timing resolution of 1.7 ns. FPGA resource utilization is compared with representative open-source RFSoC control frameworks, showing a low BRAM footprint while retaining full-rate I/Q generation and acquisition. The RF output is characterized in terms of phase noise, noise spectral density, and inter-channel timing skew. End-to-end operation is validated on a superconducting qubit through resonator spectroscopy, Rabi, Ramsey, and relaxation measurements, yielding T1 = 6.94 us and T2* = 13.50 us. FIREQ can therefore be used both as a qubit-control platform and as an experimental environment for evaluating alternative control and readout IP architectures.

0.35

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.49
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35