CS Paper Radar

Open-Source Live-Reconfigurable Multi-Mode Wearable Ultrasound

Cédric Hirschi, Federico Villani, Luca Benini, Andrea Cossettini

eess.SP cs.AR ·submitted 2026-10-01 12:48 UTC · v1
publishedunusual

Abstract

Wearable ultrasound enables continuous deep-tissue monitoring, and a single programmable probe can operate in multiple complementary modes, such as structural A-mode and Doppler flow measurement. However, each operating mode requires dedicated measurement parameters and peripheral states, with no single configuration serving all modes on resource-constrained devices. Time multiplexing of operating modes introduces reconfiguration latency that lowers the effective mode repetition rate. To address this limitation, we present an open-source, transition-aware control stack for low-latency, in-session reconfiguration of the 32-channel TinyProbe wearable platform. Operating modes are described as hardware configurations, and host-side shadow registers track the peripheral states, enabling transition-specific register updates. Transition sequences are executed either by the host (over Wi-Fi 6) or by a firmware loop on the probe MCU. We validate the stack on a pulsatile-flow phantom by interleaving blocks of 25 to 100 pulsed-wave Doppler shots at 1.43 kHz PRF with single 16-channel A-mode acquisitions, changing channel configurations at every transition. Compared to full reconfiguration, the overhead per transition decreases from 30.2 ms to 11.6 ms (host-scheduled) and 3.1 ms (MCU-scheduled). For 75-shot Doppler blocks, the multi-mode repetition rate reaches 16.0 Hz (MCU-scheduled), 90.1% of the theoretical maximum of 17.7 Hz. Concurrent reconstruction of a Doppler spectrogram and a lumen-diameter trace demonstrates the functionality of time-multiplexed flow and structural monitoring.

Comment
4 pages, 4 figures, 1 table. This work has been accepted for publication in the 2026 IEEE International Ultrasonics Symposium (IUS) proceedings. The final published version will be available via IEEE Xplore

Closest papers

Nearest neighbours by meaning across the whole index.

Open-Source Multi-Wire SPI Readout for Wearable Ultrasound Probes

cs.AR eess.SP ·2026-10-01 ·Federico Villani, Soumyo Bhattacharjee, Lisa Odermatt, Cédric Hirschi, Luca Benini +1 more
published similarity 0.65
Abstract · 4 pages, 3 figures. This work has been accepted for publication in the 2026 IEEE International Ultrasonics Symposium (IUS) proceedings. The …

Wearable ultrasound probes must transfer increasingly large acquisition payloads while maintaining compact, low-power electronics. In TinyProbe, the current bottleneck in data transfer occurs between the acquisition FPGA and the wireless system controller. This work presents an open-source, multi-wire SPI readout interface that uses serial command and address phases followed by a build-time-selectable dual- or quad-lane payload phase that is intended to address this bottleneck by increasing the potential bandwidth over the wifi limit while retaining compatibility with the Microcontroller-centric wearable US architecture. The interface emulates a serial flash memory, enabling compatibility with a broad range of microcontroller families and their existing peripheral interfaces. On the FPGA, the data path connects the existing acquisition FIFOs to the SPI interface through clock-domain crossing, sample reshaping, and packing into 32-bit words. Dual-SPI readout is integrated into the existing IGLOO2/SiWG917 TinyProbe architecture and verified at an SCLK frequency of 5 MHz. A separate Kria K26 testbed is used to characterize the FPGA SPI interface independently of the acquisition and wireless subsystems, demonstrating error-free transfers at SCLK frequencies up to 66 MHz. These measurements identify the SiWG917 multi-lane SPI implementation as the next bandwidth-limiting component and motivate a future upgrade of the system controller. The HDL and MCU implementations are released under a permissive open-source license.

0.50

U-Sonic: An Open-Source 8-Channel Ultrasound Transmit IP in a 130 nm RISC-V SoC

cs.AR eess.SP ·2026-10-01 ·Federico Villani, Nico Canzani, Marc-André Wessner, Philippe Sauter, Enrico Zelioli +3 more
published similarity 0.57
Abstract · 4 pages, 3 figures, 3 tables. This work has been accepted for publication in the 2026 IEEE International Ultrasonics Symposium (IUS) proceed…

Miniaturized ultrasound (US) probes require programmable and synchronized transmit (TX) excitation across multiple elements, while existing compact platforms often rely on limited microcontroller (MCU) pulse generators or closed-source fixed-function pulser devices. We present U-Sonic, an open-source digital US TX peripheral integrated into a 32-bit RISC-V system-on-chip (SoC). The implemented SoC integrates 8 pulser cores, while the parameterized architecture supports up to 16 channels. Each core generates single- or dual-tone bursts with programmable period, duty cycle, pulse count, polarity, and idle level, together with optional inverted stop pulses for active damping. A shared memory-mapped Open Bus Interface (OBI) enables synchronous start and stop of arbitrary channel subsets and supports composite bipolar, gated, and three-level excitation schemes. Functional correctness was verified in Verilator against a Python golden model over 4379 checked cycles across directed and randomized configurations, and confirmed on a Terasic DE10-Lite field-programmable gate array (FPGA). The design was synthesized and placed-and-routed in IHP 130 nm. The post-layout area in kilo gate equivalents (kGE), scales as 1.65 kGE plus 1.66 kGE per channel. The 8-channel instance occupies 14.9 kGE, corresponding to approximately 14.3% of the 104 kGE SoC. The register-transfer level (RTL), register descriptions, verification collateral, and software support are released as open source.

0.50

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.51
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

FLOW: Feature-Level Optimal Warping for Generalized Remote Physiological Measurement

cs.CV ·2026-09-30 ·Bo Zhao, Junzhe Cao, Dan Guo, Dongmin Huang, Wenjin Wang +3 more
similarity 0.49
Abstract

Remote photoplethysmography (rPPG) enables non-contact physiological measurement but remains vulnerable to domain shifts from illumination, motion, and sensors. We propose \textbf{FLOW (Feature-Level Optimal Warping)}, an \emph{optimal transport--driven} framework for domain-generalized rPPG. FLOW integrates a \textbf{Temporal Refinement Module (TRM)} to stabilize temporal dynamics and a \textbf{Prototype-based Cross-Temporal Optimal Transport (PCOT)} module to achieve domain-invariant alignment via learnable prototypes.Beyond feature alignment, FLOW employs soft cross-temporal correspondence modeling that aligns temporal features in a flexible manner, allowing the model to respect and preserve the intrinsic rhythmic patterns of physiological signals. Moreover, the lightweight design of our modules allows seamless integration into existing end-to-end rPPG architectures without additional preprocessing. Two regularization terms further enforce source consistency and identity preservation. Theoretically, we derive a generalization bound under conditional optimal transport. Extensive experiments across four rPPG benchmarks show that FLOW achieves state-of-the-art cross-domain performance with lightweight design and strong physiological fidelity.

0.43

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

cs.LG ·2026-10-01 ·Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu +2 more
similarity 0.49
Abstract · The authors are withdrawing this manuscript because the current experimental evaluation and validation are insufficient to adequately suppor…

Electromyography (EMG) signals vary substantially across individuals, body regions, recording sessions, and sensing hardware, limiting the generalization of models for assistive devices and human-computer interaction. Existing time-series foundation models are also computationally expensive for real-time wearable deployment and often fail to capture EMG-specific time-frequency characteristics. We present LiteEMG-FM, an efficient hybrid CNN-Transformer foundation model for practical EMG sensing. Pretrained on 16 diverse upper- and lower-limb EMG datasets, LiteEMG-FM learns representations that generalize across users and datasets. For resource-constrained deployment, we implement a hierarchical wake-up architecture in which a lightweight, always-on 1D-CNN filters rest and non-target activity and activates LiteEMG-FM only for valid gestures. We evaluate full inference offloading, split inference, and full on-device processing, characterizing their trade-offs in latency, power consumption, and memory footprint. Across diverse evaluation settings, LiteEMG-FM outperforms state-of-the-art time-series foundation models and supervised baselines, particularly under zero-calibration cross-participant and data-scarce conditions. These results demonstrate that LiteEMG-FM is an effective, efficient, and deployable foundation model for EMG applications.

0.11

Demo: Matter-Based IoMT Telemetry and Security Analysis

cs.AR cs.ETcs.RO ·2026-11-12 ·Muhammad Hassan, Masooda Bashir, Carl Gunter
similarity 0.48
Abstract

Connected health devices increasingly support health monitoring outside clinical settings, making secure and accessible physiological data important for patients and caregivers. However, device-specific applications and interfaces complicate the integration of readings from different devices. The Matter standard provides standardized device commissioning and protected communication, but its cluster library does not represent the health attribute measurement. We present a preliminary demo study of a Matter-based IoMT testbed with a specific HealthVitals cluster. Implemented in the connectedhomeip SDK on a Raspberry~Pi~5, the cluster exposes simulated heart rate, blood oxygen saturation, and body temperature. We examine commissioning, attribute retrieval, communication under simulated packet loss, and operational traffic through a reference controller. The study demonstrates that this custom telemetry model can operate within the tested Matter configuration without modifying commissioning or secure-session mechanisms. The resulting testbed gives researchers and device developers a concrete platform for investigating health-oriented extensions. It also supports exploration of local telemetry integration that could help patients and caregivers access readings across connected devices.

0.26

Sensorimotor Stickies: A Reconfigurable On-Body Platform for Closed-Loop Sensorimotor Training

cs.HC ·2026-08-13 ·Tianhong Catherine Yu, Jiwei Zheng, Chi-Jung Lee, Qifeng Yang, Tingyu Cheng +3 more
top venue similarity 0.48
Abstract

Closed-loop sensorimotor training systems can improve learning by sensing movement and delivering real-time feedback, yet most are built as fixed implementations tied to a single task, even though the core technology (inertial and tactile sensing, vibrotactile cueing, rule-based logic) remains the same. We present Sensorimotor Stickies, a reconfigurable on-body platform that treats sensing and vibrotactile feedback as modular stickies that can be patched onto the body as needed. The platform includes miniaturized adhesive modules for IMU sensing, optional tactile sensing, and vibrotactile actuation; low-power firmware and BLE infrastructure for raw streaming and motor control without task-specific rewrites; and a companion mobile app that provides a shared body-centered model for placement, calibration, and feedback authoring. Together, these components enable reconfiguration across training scenarios, user needs, and feedback setups. We evaluate the platform through technical characterization, configured application demonstration, practitioner-mediated configuration sessions, and an end-user study, demonstrating technical feasibility, reconfiguration breadth, and end-user configurability for first-time setup, calibration, and within-task feedback reconfiguration.

0.34

Few-Shot Prototype Head Adaptation for On-Device ECG Personalization on PSoC~6

cs.LG cs.AI ·2026-10-05 ·Guilherme Silva, Pedro Silva, Gladston Moreira, Eduardo Luz
published similarity 0.48
Abstract

Wearable and bedside electrocardiogram (ECG) monitors must adapt to patient-specific morphology to maintain arrhythmia detection accuracy across users, yet personalization is typically performed offline and cannot account for individual physiology, electrode placement, or recording drift. On-device adaptation by backpropagation is expensive for microcontroller-class medical devices because it requires an optimizer state, repeated backward passes through convolutional layers, and labeled arrhythmic beats that may not be available at deployment time. This letter proposes prototype-only head adaptation as a compact personalization primitive for TinyML ECG systems. A one-dimensional convolutional neural network (1-D CNN; 1,314 parameters and 72.6k multiply-accumulate operations per beat) is trained offline on the MIT-BIH Arrhythmia Database under an inter-patient protocol, frozen as a feature extractor, and exported to a PSoC 6 microcontroller. Patient-specific adaptation then reduces to computing closed-form class means in a 32-dimensional embedding space, requiring no convolutional backward pass, no iterative optimization, and only one forward pass per support beat. Prototype adaptation improves inter-patient macro-F1 from 0.635/0.639/0.646 to 0.731/0.771/0.797 at 1/5/10-shot, outperforming linear stochastic-gradient-descent (SGD) head fine-tuning at every shot count for the target tiny backbone. On-device replay over 18 one-shot episodes on a PSoC 6 Cortex-M4F matches the host macro-F1 for the prototype head (0.798), with 11.39 ms per beat, 5.2 KB flash, and 22.2 KB SRAM. A restricted variant that updates only the normal-class prototype from passively buffered sinus beats yields a consistent +0.05 macro-F1 gain, reducing the annotation burden during initial

0.37