Complementary-Aperture Pulse Sequencing for Fundamental-Band Nonlinearity Parameter Imaging

Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila

eess.SP physics.med-ph ·submitted 2026-09-19 17:50 UTC · v1
published

Abstract

The depletion method (DM) enables the estimation of the acoustic nonlinearity parameter, B/A, in pulse-echo ultrasound using fundamental-band signals from low- and high-pressure acquisitions, but requires accurate knowledge of the acoustic-pressure scaling factor. This requirement limits experimental translation because of the slightly nonlinear scaling between excitation voltage set on the ultrasound system and pressure at the probe. We propose a complementary-aperture pulse sequence (CAPS) that recovers the linearly scaled low-pressure signal by coherently summing RF acquisitions from interleaved transmit subapertures whereas a full-aperture transmission provides the high-pressure signal maintaining the same excitation voltage configured in the ultrasound system. In silico phantoms of a homogeneous sample and a reference evaluated four aperture partitions of CAPS and compared them with the DM under relative scaling-factor errors from 0.01% to 10%. Using the DM, errors of 0.1% and 1% produced absolute B/A biases of up to 27.3% and 58.3%, respectively. CAPS yielded mean B/A values of 8.9 for a prescribed value of 9, with biases of less than 1.3% across all partitions, matching an ideally calibrated DM. These results demonstrate that CAPS preserves depletion-based B/A estimation without using the pressure scaling factor as a reconstruction input, supporting experimental and in vivo implementation without pressure-ratio calibration.

Comment
4 pages, 3 figures, accepted to 22nd International Symposium on Medical Information Processing and Analysis (SIPAIM)

Closest papers

Nearest neighbours by meaning across the whole index.

Closed-form weak-wave propagation pressure amplitudes for arbitrary power-law attenuation

eess.SP physics.med-ph ·2026-09-16 ·Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila
publishedunusual similarity 0.63
Abstract · 7 pages, 2 figures, submitted to JASA Express Letters

Biological tissues exhibit power-law frequency dependence of the attenuation coefficient. We derive closed-form weak-wave expressions for fundamental, second-, and third-harmonic pressure amplitudes of monochromatic acoustic plane waves in homogeneous media with arbitrary power-law attenuation to extend classical expressions for quadratic attenuation. For linear frequency dependence of attenuation, one-dimensional simulations using the k-Wave k-space pseudospectral solver yielded 35-42% (classical) and 0-2% (proposed) normalized root-mean-square errors for fundamental-band depletion. This extension supports improved fundamental-band B/A estimation for quantitative ultrasound tissue characterization. A proof-of-concept through-transmission application in phantoms with nearly linear attenuation yielded experimental B/A estimation errors of 23.7-52.7% (classical) and 4.0-5.9% (proposed).

0.41

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.61
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35

Common Offset Gathers for Efficient Multistatic Beamforming in Frequency Domain

eess.SP physics.med-ph ·2026-10-29 ·Marko Jakovljevic, Xiaohong Wang, Ion Candel, Anthony E. Samir, Kai Thomenius
similarity 0.59
Abstract · 11 pages

Frequency-domain beamformers reconstruct ultrasound images with far fewer operations than delay-and-sum (DAS). However, for multistatic synthetic aperture data, they require Fourier transforms over the full transmit-receive aperture and large amounts of memory, limiting their use for volumetric imaging. Here, we adapt common offset gathers (COG) from seismic imaging to frequency-domain beamforming: transmit-receive pairs with the same offset are beamformed independently using a bistatic formulation, holding only one offset gather in memory at a time. We combine COG with the range-Doppler algorithm (RDA) and evaluate COG RDA against DAS and conventional multistatic RDA using simulated, phantom, and in vivo acquisitions. For linear arrays, COG RDA reduced memory requirements by two orders of magnitude relative to conventional RDA and beamformed up to 25x faster than DAS, with comparable image quality. For a 32x32-element matrix array, COG RDA requires only 2-D instead of 4-D Fourier transforms, and reconstructed a volume on a GPU 32x faster and with 67x less energy than DAS. COG RDA makes frequency-domain multistatic beamforming practical for matrix arrays and power-constrained devices.

0.32

A Reconfigurable Pipelined-SAR ADC with Embedded Compression for Temporal Compressed-Sensing Ultrasound Imaging

eess.SP physics.med-ph ·2026-08-28 ·Reza Pakdaman Zangabad, Xitie Zhang, Levent Degertekin, Shaolan Li
similarity 0.56
Abstract · 15 pages, 11 figures, Journal

Compact ultrasound imaging systems are increasingly constrained by receiver-side sampling, conversion, memory, and data-transfer requirements. This work presents a compressed-sensing pipelined successive-approximation-register analog-to-digital converter (CS-SAR ADC) for acquisition-side temporal compression of pre-beamformed medical ultrasound radio-frequency (RF) data. Pseudo-random polarity modulation and charge-domain accumulation are embedded in the SAR sampling network so that multiple consecutive RF samples are encoded into one measurement before quantization, supporting temporal compression ratios of $N_{cT}=1$, 2, and 4. The compressed outputs are recovered off chip using a probe-specific pulse-dictionary RF model and then processed with conventional ultrasound beamforming. A 65-nm CMOS prototype was measured with a 1.2-V supply and 50-MHz master clock. In the non-compressed mode, it operates at 10 MS/s, consumes 964.49~$μ$W, and achieves 44.12-dB SNDR and 56.40-dB SFDR for a 7.7-kHz input. The ADC output rates decrease to 5 MS/s and 2.5 MS/s for $N_{cT}=2$ and 4. Across all evaluated RF traces, median NCC values were 0.981 and 0.932, with median NRMSE values of 0.36 and 0.56, respectively. Wire-phantom localization error remained below 0.04 mm with no appreciable FWHM degradation. In the speckle-rich cyst phantom, SSIM remained 0.94 and 0.87, while CNR decreased from 3.534 in the reference to 2.047 and 1.379. These results demonstrate a hardware-realistic tradeoff in which temporal compression substantially reduces ADC conversion count and output data rate while preserving point-target geometry, whereas low-contrast cyst conspicuity is more compression-sensitive.

0.28

Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review

eess.IV physics.med-ph ·2026-08-23 ·Can Deniz Bezek, Orcun Goksel
survey similarity 0.54
Abstract

Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging.

0.28

Compression Hurts, Pooling Helps: Information Loss in Rayleigh-Scale Estimation from B-Mode Ultrasound

eess.IV cs.CVstat.AP ·2026-09-17 ·D. Hudson Smith, Ahmer Raza
similarity 0.53
Abstract · 20 pages, 7 figures

Clinical B-mode images are widely available as potential data sources for quantitative ultrasound (QUS) analysis for tissue characterization. However, standard clinical ultrasound devices apply unknown log-compression to RF envelope data before display and storage. Previous work has demonstrated estimation of the underlying RF envelope statistics in the presence of an unknown compression law. Using Fisher information analysis, we show that finite-offset log compression causes severe information loss when estimating the Rayleigh scale $σ$, which controls diffuse speckle. For a single image window, unknown compression raises the minimum achievable variance for unbiased estimation of $σ$ by a compression-independent factor of approximately 34.98. When $M$ equal-sized windows share the same unknown compression settings, the excess variance decays as $1/M$; even in the most favorable regime, reducing the variance inflation factor below 1.1 requires 340 windows. Our analysis treats the contrast parameter $a$ as unknown and the boundary offset $b$ as known; estimating $b$ experimentally shows even larger variance. We validate this theory using synthetic estimation experiments and demonstrate RF-scale recovery on real RF-envelope windows from the OASBUD dataset. Together, these results clarify the limitations of using routine B-mode images for QUS.

0.32

Open-H-RF: A Large-Scale Ultrasound Raw Channel Dataset Initiative

eess.SP ·2026-10-09 ·T. S. W. Stevens, S. W. Penninga, W. L. van Nierop, O. Nolan, F. Duelmer +181 more
dataset similarity 0.51
Abstract · Preprint: 15 pages, 15 figures, 3 tables. Dataset (v1.0): https://open-h.github.io/Open-H-RF

Medical ultrasound is a widely accessible, real-time imaging modality, yet progress in data-driven ultrasound research is constrained by the scarcity of large, open collections of raw channel data. Existing public datasets are predominantly based on reconstructed images, while the smaller number of open raw channel datasets is generally specialized to individual reconstruction or imaging tasks, limiting the development of general-purpose methods and foundation models that operate directly on ultrasound signals. While interpretive tasks can be performed on reconstructed images, many of the key technical challenges in ultrasound imaging, such as aberration correction and reverberation reduction, require the raw channel data itself. We introduce Open-H-RF, a community-driven open dataset initiative comprising approximately 40 TB of medical ultrasound raw channel data in 19,332 acquisitions, contributed by 38 institutions across academia and industry, spanning in-vivo, phantom, and simulated data. Each dataset is annotated with a number of supported tasks, ranging from generalized reconstruction, speed-of-sound estimation, and aberration correction to blood flow imaging, motion estimation, quantitative ultrasound, and image interpretation. Open-H-RF provides a unified, self-contained data format that captures raw channel data together with the acquisition, probe, metadata, and reconstruction information required for reproducible processing across scanners and acquisition schemes. The corpus is publicly hosted under a permissive CC BY 4.0 license and can be streamed programmatically and selectively at scale. By bringing heterogeneous ultrasound data into a common representation, backed by modern data infrastructure, Open-H-RF lowers the barrier to working with raw channel data and aims to open medical ultrasound research to new communities. See https://open-h.github.io/Open-H-RF.

0.47

Physics-Grounded Objective-Conditioned Deep Beamforming for Adaptive Resolution-Contrast Control in Plane-Wave Ultrasound Imaging

eess.SP ·2026-10-05 ·Gopika Gopikrishnan, Mahesh Raveendranatha Panicker
similarity 0.50
Abstract

Plane-wave ultrasound enables ultrafast imaging but remains constrained by a receive-aperture-dependent resolution- contrast trade-off. Fine structures benefit from high spatial resolution, whereas diffuse tissue and lesions often require improved contrast and clutter suppression. These objectives favor different receive-aperture configurations, yet conventional beamformers operate at a fixed imaging point. We propose a physics-grounded, objective-conditioned deep beamformer that enables controllable image formation within a single network. From single-plane-wave channel data, the network predicts spatially varying receive-apodization weights, conditioned on the desired imaging objective through feature-wise linear modulation. The conditioning variable is explicitly tied to a physically defined receive-aperture configuration and supervised using the correspondingcoherent-plane-wave-compounding target. Differentiable, region-of-interest-aware, physics-guided quality losses further promote objective-specific resolution and contrast during end-to-end training. The model is trained exclusively on simulated channel data spanning diverse target morphologies and echogenicities, and evaluated zero-shot on the PICMUS and CUBDL datasets, including unseen probe geometries. The proposed framework generally improves upon single-plane-wave delay-and-sum reconstruction while providing objective-dependent control. On PICMUS, the proposed method improves gCNR by up to 16.8% and axial resolution by 22% compared with the reference beamforming method. Moreover, switching between the contrast- and resolution-oriented objectives enables controllable changes of up to 4.9% in lesion contrast and 11.4% in lateral resolution. Compared with the best-performing learning-based baselines, the proposed method reduces lateral full-width-at-half-maximum by 5.9% and improves generalized contrast-to-noise ratio by 6.6%.

0.29