CS Paper Radar

Ultrasound Elastography: Excitation Methods and Low-Cost Alternative

Corin F. Otesteanu

cs.CV eess.IV ·submitted 2026-11-11 15:56 UTC · v1
published

Abstract

Ultrasound elastography (or elasticity imaging) is a method that characterizes the tissue mechanical properties with the purpose of aiding the diagnosis of certain pathologies. Many novel clinical applications use the assumption that these tissue properties are changed in the presence of pathological processes. Characterization of tissue mechanical properties is achieved by imaging the response of the tissue to an induced stress or excitation. A plethora of approaches have been used in the scientific community to induce excitation in tissue, which usually require additional tools or devices than are costly. Furthermore these are usually integrated in the imaging pipeline using additional software or hardware for control. An alternative that is simpler, faster to integrate (and low-cost) is proposed in this work, by using readily available smartphones as a source of mechanical excitation. The induced displacements are used to solve the elasticity inverse problem (IP) using a finite element method (FEM) approach. Preliminary elasticity reconstructions of a phantom that mimics tissue are similar to when using a dedicated actuator as means of inducing harmonic displacements, illustrating the feasibility of our low-cost ultrasound elasography approach.

Journal ref
2019 International Conference on Systems, Signals and Image Processing (IWSSIP), Osijek, Croatia, 2019, pp. 103-107
DOI
10.1109/IWSSIP.2019.8787332

Closest papers

Nearest neighbours by meaning across the whole index.

Finite Element Elastographic Analysis of Kidney MRI for Computational Assessment of Chronic Kidney Disease

eess.IV ·2026-11-04 ·A. Bhattacharjee, M. M. Rahman, A. Srivastava, E. H. Bhuiyan
unusual similarity 0.59
Abstract · Original research article

Background and Objective: Bridging kidney MRI with patient-specific computational biomechanics may enable accurate, noninvasive assessment of chronic kidney disease. To develop a finite element method (FEM)-based computational elastography framework for estimating renal biomechanical properties from conventional kidney MRI and to evaluate its ability to differentiate chronic kidney disease (CKD) from healthy controls. Methods: Kidney segmentation masks from healthy control and CKD subjects were converted into triangulated surface meshes, and watertight surfaces were tetrahedralized to create volumetric FEM meshes. Kidney tissue was modeled as a nearly incompressible Kelvin-Voigt viscoelastic material. Harmonic wave propagation simulations were performed using FEM, followed by Helmholtz-based elastographic inversion to estimate complex shear modulus distributions. Derived biomechanical parameters were used for CKD classification using machine learning models. Results: FEM-derived stiffness estimates showed consistency with stiffness ranges previously reported in human renal MRE studies and also showed measurable differences between healthy and CKD groups. Machine learning models trained on FEM-derived features achieved classification performance up to 86.26% cross-validation accuracy with an AUC of 0.92. Conclusion: FEM-derived elastographic parameters showed potential for distinguishing CKD from healthy tissue and may provide an alternative for renal biomechanical assessment without dedicated MRE acquisition.

0.26

A hybrid CNN-adjoint optimization framework for reconstruction of viscoelastic tissue properties in magnetic resonance elastography

cs.LG math.OCmath.NA ·2026-10-02 ·Anwesa Dey, Johann Rudi, Elena Cherkaev
similarity 0.57
Abstract

Magnetic resonance elastography (MRE) is a noninvasive imaging modality for quantifying the viscoelastic properties of soft tissues from shear wave propagation. Recovering the complex-valued shear modulus from measured displacement fields leads to a severely ill-posed inverse problem, particularly in the presence of noise and limited boundary excitations. We investigate adjoint-based optimization, convolutional neural network (CNN) reconstruction, and a hybrid framework combining both approaches. The forward model is based on a scalar form of the modified stationary Stokes system with a complex shear modulus. We establish well-posedness of the forward problem, existence of minimizers, and first-order optimality conditions for the adjoint-based formulation, and implement a nonlinear conjugate-gradient method with Armijo line search. While PDE-constrained optimization can accurately refine coefficient reconstructions, its performance depends strongly on initialization. We therefore construct a two-dimensional CNN that maps complex-valued displacement measurements to spatially varying complex shear modulus fields and provides rapid, informative initial reconstructions. The proposed hybrid method uses the CNN reconstruction to initialize the adjoint-based optimization, yielding faster convergence and improved accuracy. The CNN is trained on coefficient fields containing individual perturbations and tested on both individual and previously unseen combined configurations. Numerical experiments demonstrate that the CNN generalizes to these more challenging configurations, while subsequent PDE-constrained optimization further refines the reconstructed coefficient. These results demonstrate the potential of combining data-driven initialization with physics-based optimization for efficient and accurate MRE reconstruction.

0.12

WAVES: Wearable Active Vibroacoustic Elasticity Sensing for Low-Cost and Non-Invasive Muscle Stiffness Monitoring

cs.ET ·2026-11-04 ·Shubham Rohal, Dong Yoon Lee, Shijia Pan
similarity 0.56
Abstract

Muscle stiffness is a physiologically meaningful biomarker associated with a wide range of musculoskeletal and neurological conditions. However, existing muscle stiffness assessment methods, such as shear wave elastography (SWE), manual palpation, and handheld mechanical probes, remain impractical for continuous, everyday monitoring due to bulky hardware, operator dependence, and limited self-use. Meanwhile, wearable muscle-sensing modalities such as Electromyography (EMG) and Mechanomyography (MMG) primarily capture muscle activation rather than passive mechanical properties of tissue at rest, leaving a critical gap in portable monitoring of resting muscle stiffness. In this work, we present WAVES, a wearable system for continuous monitoring of muscle stiffness via active vibroacoustic sensing. WAVES injects controlled vibroacoustic excitation into soft tissue and estimates muscle stiffness by measuring shear-wave propagation velocity through Time-Difference-of-Arrival (TDoA) analysis across spatially distributed wearable sensors. To achieve accurate TDoA estimation with low-cost wearable hardware, we develop a physiology- and quality-guided vibroacoustic sensing framework that effectively screens and refines TDoA for accurate stiffness estimation. We evaluate WAVES through characterization experiments using ballistic jelly and end-to-end on-body evaluation with human participants. Results demonstrate that WAVES can robustly estimate muscle stiffness across multiple users and different superficial muscles while enabling lightweight, wearable deployment for everyday use. WAVES is able to achieve a muscle stiffness estimation error of 13.1% or less across multiple users and multiple muscle groups.

0.25

Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review

eess.IV physics.med-ph ·2026-08-23 ·Can Deniz Bezek, Orcun Goksel
survey similarity 0.56
Abstract

Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging.

0.28

EL-DIP: A Deep Image Prior Framework for Accurate,Efficient, and Noise-Robust Elastography

eess.IV cs.CE ·2026-10-22 ·Hao Liu, Fuyi Li, Dong Liu, Yue Mei, Sheng Mao
similarity 0.54
Abstract

Elastography is a key technique for non-invasive imaging, yet it remains severely ill-posed and sensitive to measurement noise, causing blurring and artifacts. We propose EL-DIP, a training-data-free framework based on deep image prior (DIP) that reconstructs heterogeneous shear modulus distributions. Inverse distance weighting interpolation enables arbitrary-shaped domains, and adjoint sensitivity analysis provides efficient gradient computation. Numerical and experimental studies show that EL-DIP accurately recovers inclusion geometry and modulus across different noise levels. Under extreme noise, image fidelity improves by approximately 97.1% over conventional methods. We believe that this method has great potential as a robust tool for biomedical diagnosis,biomechanical characterization, and non-destructive evaluation.

0.20

Deformable CT-US Registration via Anatomy-Aware Implicit Neural Representations

cs.CV ·2026-10-06 ·Agnieszka Lach, Magdalena Wysocki, Feng Li, Mohammad Farid Azampour, Benjamin D. Killeen +5 more
published similarity 0.54
Abstract · 10 pages, 3 figures. Accepted at the 7th International Workshop on Advances in Simplifying Medical UltraSound (ASMUS 2026), held with MICCAI…

Slice-to-volume registration between ultrasound (US) and preoperative computed tomography (CT) imaging would enhance many minimally invasive interventions, for example by locating soft tissue structures intra-operatively that are discernible in CT. While optical tracking enables initial rigid registration, contact from the probe induces soft tissue deformations that inhibit accurate alignment. In this work, we introduce a deformable CT-ultrasound registration framework that incorporates anatomical priors derived from CT to improve registration under deformation. Rigid registration is first established using a robot-assisted optical tracking system, after which a deformable transformation is estimated using a sinusoidal implicit neural representation (SIREN) optimized per frame. Tissue stiffness is approximated from CT-based HU values and used as spatially varying regularization, suppressing deformation in rigid structures such as bone while allowing more flexibility in soft tissue. Two additional constraints capture the physics of probe contact: a contact-zone displacement prior that drives the displacement field to compress tissue below the probe face, and a fan-geometry regularization term based on beam direction and convex transducer field of view. Model parameters are optimized with a normalized gradient field (NGF). The proposed approach improves alignment over rigid initialisation by 17% and outperforms classical deformable baselines while maintaining near-zero topological folding.

0.52

Ultrasound and Magnetic Resonance Elastography of the Neck: Biomechanical Basis, Clinical Applications and Methodological Challenges

eess.IV ·2026-10-08 ·Rashedul Hasan, Anna Yang, Kishani Kandasamy, Hossein Bahreinizad, Md Ashikuzzaman +2 more
unusual similarity 0.54
Abstract

Many neck disorders, from chronic neck pain and headache to thyroid and nodal malignancy and radiation-induced fibrosis, both arise from and alter the mechanical properties of neck tissues, yet clinical assessment still relies on morphology, palpation and symptoms. Ultrasound and magnetic resonance elastography (MRE) now allow these properties to be measured in vivo, but the neck literature differs widely in methodology and remains dispersed across modalities and tissues. This review brings together the biomechanical basis of neck tissue behavior, the clinical conditions that alter it, and the principles and applications of ultrasound elastography and MRE in the neck. We show that ultrasound elastography has demonstrated diagnostic value for thyroid nodules and cervical lymph nodes, while neck MRE has been shown to be feasible but remains at an early stage. Across both modalities, reported values depend strongly on fiber orientation, posture, muscle activation and acquisition conditions. We therefore propose reporting recommendations and discuss how measurements beyond stiffness, including anisotropy, viscosity and nonlinearity, could improve disease management and inform computational models of the neck.

0.24

Initial condition recovery in nonlinear damped viscous photoacoustic tomography using a convolutional neural network-guided gradient-free optimization framework

cs.LG math.OC ·2026-10-01 ·Madhu Gupta, Anwesa Dey, Prapti Tala, Souvik Roy
similarity 0.53
Abstract

Photoacoustic tomography (PAT) is a hybrid imaging modality that combines high optical contrast with high ultrasonic resolution for biomedical imaging applications. In this work, we investigate the inverse problem of recovering the initial pressure distribution from boundary measurements in the presence of nonlinear acoustic propagation and viscous attenuation effects. To model these phenomena more accurately, we consider a nonlinear damped viscoelastic wave equation incorporating spatially varying sound speed, temporal attenuation, and nonlinear propagation mechanisms. We first establish the well-posedness of the corresponding forward problem using a Galerkin approximation combined with energy estimates and a fixed-point argument. For the inverse problem, we derive existence, uniqueness, and local uniqueness results under suitable assumptions through a harmonic extension reduction, spectral Laplace transform techniques, and observability estimates. To numerically reconstruct the initial pressure field, we develop a hybrid reconstruction framework that combines a convolutional neural network (CNN) with a gradient-free optimization strategy based on the sequential quadratic Hamiltonian (SQH) method derived from Pontryagin's maximum principle. The CNN is used to generate an informative initial guess, while the SQH framework enforces the governing PDE dynamics during the reconstruction process. Numerical experiments demonstrate that the proposed hybrid strategy significantly improves reconstruction quality, contrast, and robustness compared to standalone time-reversal and CNN-based approaches.