CS Paper Radar

Finite Element Elastographic Analysis of Kidney MRI for Computational Assessment of Chronic Kidney Disease

A. Bhattacharjee, M. M. Rahman, A. Srivastava, E. H. Bhuiyan

eess.IV ·submitted 2026-11-04 21:03 UTC · v1
unusual

Abstract

Background and Objective: Bridging kidney MRI with patient-specific computational biomechanics may enable accurate, noninvasive assessment of chronic kidney disease. To develop a finite element method (FEM)-based computational elastography framework for estimating renal biomechanical properties from conventional kidney MRI and to evaluate its ability to differentiate chronic kidney disease (CKD) from healthy controls. Methods: Kidney segmentation masks from healthy control and CKD subjects were converted into triangulated surface meshes, and watertight surfaces were tetrahedralized to create volumetric FEM meshes. Kidney tissue was modeled as a nearly incompressible Kelvin-Voigt viscoelastic material. Harmonic wave propagation simulations were performed using FEM, followed by Helmholtz-based elastographic inversion to estimate complex shear modulus distributions. Derived biomechanical parameters were used for CKD classification using machine learning models. Results: FEM-derived stiffness estimates showed consistency with stiffness ranges previously reported in human renal MRE studies and also showed measurable differences between healthy and CKD groups. Machine learning models trained on FEM-derived features achieved classification performance up to 86.26% cross-validation accuracy with an AUC of 0.92. Conclusion: FEM-derived elastographic parameters showed potential for distinguishing CKD from healthy tissue and may provide an alternative for renal biomechanical assessment without dedicated MRE acquisition.

Comment
Original research article

Closest papers

Nearest neighbours by meaning across the whole index.

Ultrasound Elastography: Excitation Methods and Low-Cost Alternative

cs.CV eess.IV ·2026-11-11 ·Corin F. Otesteanu
published similarity 0.59
Abstract

Ultrasound elastography (or elasticity imaging) is a method that characterizes the tissue mechanical properties with the purpose of aiding the diagnosis of certain pathologies. Many novel clinical applications use the assumption that these tissue properties are changed in the presence of pathological processes. Characterization of tissue mechanical properties is achieved by imaging the response of the tissue to an induced stress or excitation. A plethora of approaches have been used in the scientific community to induce excitation in tissue, which usually require additional tools or devices than are costly. Furthermore these are usually integrated in the imaging pipeline using additional software or hardware for control. An alternative that is simpler, faster to integrate (and low-cost) is proposed in this work, by using readily available smartphones as a source of mechanical excitation. The induced displacements are used to solve the elasticity inverse problem (IP) using a finite element method (FEM) approach. Preliminary elasticity reconstructions of a phantom that mimics tissue are similar to when using a dedicated actuator as means of inducing harmonic displacements, illustrating the feasibility of our low-cost ultrasound elasography approach.

0.36

Physics-Informed Deep Learning for Shear Wave Speed Estimation in MR Elastography

eess.IV cs.LGphysics.med-ph ·2026-11-19 ·Stefan Martin, Jakob Schattenfroh, Patrick Schuenke, Felix Frederik Zimmermann, Ingolf Sack +2 more
top venuecode/data similarity 0.53
Abstract · 13 pages (incl. cover page), 6 figures, 2 tables. Accepted version of the article published in IEEE Transactions on Biomedical Engineering. …

Objective: Magnetic Resonance Elastography (MRE) is a non-invasive imaging technique for mapping biomechanical properties of in vivo tissue, including shear wave speed (SWS), but involves intrinsically slow data acquisition and an ill-posed wave inversion. Instead of relying on handcrafted image priors, we propose a data-driven approach jointly combining image reconstruction and MRE inversion for robust SWS estimation from undersampled k-space data. Methods: Our physics-informed reconstruction framework comprises two blocks: a model-based neural network (NN)-regularized reconstruction module and a phase-gradient inversion (k-MDEV) calculating SWS from the reconstructed images. Concatenating both blocks yields an end-to-end trainable method to estimate SWS directly from measured k-space data. We evaluated the method on retrospectively highly undersampled brain MRE data and compared it to a total variation (TV) minimization-based approach. We assessed the impact of end-to-end training (qualitative images and SWS maps as targets) versus pre-training (qualitative images as targets) and applied the method also to in vivo data. Results: Our approach significantly reduces NRMSE by 30% compared to TV. End-to-end training improves SWS estimation over separate image reconstruction and SWS calculation. Conclusion: Accurate SWS quantification is possible at acceleration factors up to 19. Our method significantly outperforms TV, highlighting the need for data-driven regularization in this challenging MR problem. Further, our approach successfully generalizes to in vivo data. Significance: We present the first end-to-end trainable MRE reconstruction method for estimating SWS maps directly from k-space. NN-based reconstruction can enable rapid stiffness mapping for dynamic studies, functional imaging, and real-time clinical feedback.

0.49

EL-DIP: A Deep Image Prior Framework for Accurate,Efficient, and Noise-Robust Elastography

eess.IV cs.CE ·2026-10-22 ·Hao Liu, Fuyi Li, Dong Liu, Yue Mei, Sheng Mao
similarity 0.52
Abstract

Elastography is a key technique for non-invasive imaging, yet it remains severely ill-posed and sensitive to measurement noise, causing blurring and artifacts. We propose EL-DIP, a training-data-free framework based on deep image prior (DIP) that reconstructs heterogeneous shear modulus distributions. Inverse distance weighting interpolation enables arbitrary-shaped domains, and adjoint sensitivity analysis provides efficient gradient computation. Numerical and experimental studies show that EL-DIP accurately recovers inclusion geometry and modulus across different noise levels. Under extreme noise, image fidelity improves by approximately 97.1% over conventional methods. We believe that this method has great potential as a robust tool for biomedical diagnosis,biomechanical characterization, and non-destructive evaluation.

0.20

Development and Evaluation of Ultrasound Image Learning Pipelines for MASLD Risk Stratification

eess.IV cs.CV ·2026-09-03 ·Guangyi Zhang, Xiaohong Wang, Eugene Cheah, Peng Guo, Brian A. Telfer +2 more
published similarity 0.52
Abstract · 7 pages, 4 figures. Accepted and presented at IEEE EMBC 2026

Metabolic dysfunction-associated steatotic liver disease (MASLD) affects approximately 30% of the general population. Ultrasound-based imaging, including B-mode imaging and shear wave elastography (SWE), is widely used for noninvasive fibrosis assessment; however, the role of deep learning-based ultrasound image learning for MASLD risk stratification remains insufficiently characterized. In this study, we developed and evaluated ultrasound image learning pipelines using B-mode and SWE images for fibrosis staging and identification of patients with at-risk metabolic dysfunction-associated steatohepatitis (MASH). A total of 250 ultrasound examinations, one exam per subject, were included. Model performance was evaluated using 3-fold cross-validation with area under the receiver operating characteristic curve (AUROC). End-to-end SWE image learning achieved performance comparable to operator-guided SWE across fibrosis stages. Overall, SWE-based learning consistently outperformed B-mode image learning in fibrosis staging, with AUROC improvements from 0.64 (95%CI: [0.56, 0.72]) to 0.72 (95% CI: [0.65, 0.79]) for F>=2 (significant fibrosis, p=0.11), from 0.67 (95%CI: [0.58, 0.75]) to 0.78 (95% CI:[0.72, 0.85]) for F>=3 (advanced fibrosis, p=0.02), and from 0.69 (95%CI: [0.56, 0.82]) to 0.80 (95%CI: [0.72, 0.89]) for F4 (cirrhosis, p=0.10). These findings highlight the potential of SWE image learning for MASLD risk stratification.

0.35

A hybrid CNN-adjoint optimization framework for reconstruction of viscoelastic tissue properties in magnetic resonance elastography

cs.LG math.OCmath.NA ·2026-10-02 ·Anwesa Dey, Johann Rudi, Elena Cherkaev
similarity 0.51
Abstract

Magnetic resonance elastography (MRE) is a noninvasive imaging modality for quantifying the viscoelastic properties of soft tissues from shear wave propagation. Recovering the complex-valued shear modulus from measured displacement fields leads to a severely ill-posed inverse problem, particularly in the presence of noise and limited boundary excitations. We investigate adjoint-based optimization, convolutional neural network (CNN) reconstruction, and a hybrid framework combining both approaches. The forward model is based on a scalar form of the modified stationary Stokes system with a complex shear modulus. We establish well-posedness of the forward problem, existence of minimizers, and first-order optimality conditions for the adjoint-based formulation, and implement a nonlinear conjugate-gradient method with Armijo line search. While PDE-constrained optimization can accurately refine coefficient reconstructions, its performance depends strongly on initialization. We therefore construct a two-dimensional CNN that maps complex-valued displacement measurements to spatially varying complex shear modulus fields and provides rapid, informative initial reconstructions. The proposed hybrid method uses the CNN reconstruction to initialize the adjoint-based optimization, yielding faster convergence and improved accuracy. The CNN is trained on coefficient fields containing individual perturbations and tested on both individual and previously unseen combined configurations. Numerical experiments demonstrate that the CNN generalizes to these more challenging configurations, while subsequent PDE-constrained optimization further refines the reconstructed coefficient. These results demonstrate the potential of combining data-driven initialization with physics-based optimization for efficient and accurate MRE reconstruction.

0.12

From Adult Renal Masses to Pediatric Wilms Tumors: Evaluating Cross-Domain Generalization of Kidney Lesion Segmentation on MRI

cs.CV ·2026-10-16 ·Sarah de Boer, Myrthe A. D. Buser, Hartmut Häntze, Jawed Nawabi, Lisa C. Adams +6 more
similarity 0.51
Abstract

Deep learning segmentation models for pediatric oncology are often trained on small, single-center cohorts, whereas much larger datasets exist for adult diseases, such as kidney cancer. Whether models trained on adult renal lesions generalize to pediatric Wilms tumors remains unclear. We trained a segmentation model on single-sequence T1- or T2-weighted adult kidney MRI and evaluated it on a held-out adult test set and a pediatric Wilms tumor cohort, where it was compared with a pediatric-specific nnU-Net. Segmentation performance was quantified using the Dice similarity coefficient (DSC) and 95th-percentile Hausdorff distance. On the adult test set, the model achieved a median DSC of 0.86 for renal lesions. On the pediatric cohort, the adult-trained model achieved a median DSC of 0.85 compared with 0.90 for the pediatric-specific model. Despite differences in age, anatomy, and tumor type, the adult-trained model showed promising performance on pediatric Wilms tumors, with only a modest difference in median DSC compared with the pediatric-specific model. However, non-inferiority could not be shown, highlighting the value of pediatric training data. In future work, a fine-tuning strategy could be explored.

0.17

Element-Wise Femoral Stress Prediction: A Hybrid Graph Neural Network Surrogate for Finite Element Analysis

cs.LG ·2026-11-18 ·Sikha O K, Abdollah Moslemi, Elham Alizadeh, Ludovic Humbert, Miguel A. Gonzalez Ballester +1 more
code/data similarity 0.51
Abstract · This paper is submitted to Frontiers in Artificial Intelligence

Hip fractures represent a significant clinical challenge because they cause excess disability and mortality, and have a growing incidence in aging populations, as bone fragility increases. Although finite element analysis (FEA) provides biomechanical assessment of femoral strength, its clinical applicability is mainly limited by high computational cost. Conventional machine learning (ML) approaches have been explored as surrogate models for FEA; predictions are fast but fail to capture the spatial and topological structure of finite element meshes. To address these limitations, this study proposes a hybrid Graph Neural Network (GNN)-based framework for femoral stress prediction using graph-structured finite element modeling (FEM) data. The proposed GCN-SAGE-Residual architecture combines graph convolution, neighborhood aggregation, and residual learning to model spatial dependencies and stress propagation across mesh elements. We systematically evaluated 14 models in a primary comparison, spanning classical ML methods and baseline GNN architectures, complemented by a targeted architectural ablation that isolates the contribution of each component of the proposed design. Evaluation results demonstrate that the proposed hybrid architecture achieves the strongest predictive performance among all evaluated models. The proposed hybrid model achieves the best performance with an R^2 score of 0.8022 and mean absolute error of 2.879 MPa, highlighting the importance of incorporating mesh topology in biomechanical prediction tasks. The proposed framework provides a scalable and computationally efficient alternative for FEM-based orthopedic analyses and fracture risk assessment. The code is publicly available on GitHub.

0.34

An End-to-End Framework for Modelling Pneumatic Soft Robots Based on Differentiable Finite Element Methods

cs.RO eess.SY ·2026-10-03 ·Shaohong Zhong, Yao Yao, Perla Maiolino, Ingmar Posner
top venue similarity 0.51
Abstract · Published in IEEE Robotics and Automation Letters (RA-L)

Soft robots present significant modelling challenges due to their non-linearity, complex dynamics and potentially intricate geometries. These difficulties in accurate system identification and dynamics modelling limit their applications in precise robotics tasks. Prior modelling approaches typically suffer from trade-offs in accuracy, computational efficiency, or speed. The differentiable finite element method (FEM) offers a promising balance between these desiderata for soft robot modelling, and enables the use of gradients for efficient calibration and trajectory optimisation. In this paper, we propose an end-to-end differentiable FEM-based framework designed to streamline modelling and system identification for pneumatic soft robots, enabling the generation of reliable models for downstream tasks. The framework automates the conversion of computer-aided designs into voxelised tetrahedral viscoelastic FEM meshes that accurately represent the robot's geometry and actuation mechanism. By integrating easily acquired point cloud data with differentiable FEM, the framework achieves precise identification of material and dynamic actuation parameters using a minimal experimental setup. Additionally, the differentiable nature of the model facilitates trajectory optimisation by leveraging gradients from robot dynamics and contact interactions. We validate the framework by modelling a complex bellow-shaped pneumatic soft robot and demonstrate its efficacy in real-world motion planning tasks. Experimental results indicate high modelling accuracy, with a maximum positional error of less than 3 mm, and successful application in tasks such as path following and grasping.

0.75