WAVES: Wearable Active Vibroacoustic Elasticity Sensing for Low-Cost and Non-Invasive Muscle Stiffness Monitoring

Shubham Rohal, Dong Yoon Lee, Shijia Pan

cs.ET ·submitted 2026-11-04 19:50 UTC · v1

Abstract

Muscle stiffness is a physiologically meaningful biomarker associated with a wide range of musculoskeletal and neurological conditions. However, existing muscle stiffness assessment methods, such as shear wave elastography (SWE), manual palpation, and handheld mechanical probes, remain impractical for continuous, everyday monitoring due to bulky hardware, operator dependence, and limited self-use. Meanwhile, wearable muscle-sensing modalities such as Electromyography (EMG) and Mechanomyography (MMG) primarily capture muscle activation rather than passive mechanical properties of tissue at rest, leaving a critical gap in portable monitoring of resting muscle stiffness. In this work, we present WAVES, a wearable system for continuous monitoring of muscle stiffness via active vibroacoustic sensing. WAVES injects controlled vibroacoustic excitation into soft tissue and estimates muscle stiffness by measuring shear-wave propagation velocity through Time-Difference-of-Arrival (TDoA) analysis across spatially distributed wearable sensors. To achieve accurate TDoA estimation with low-cost wearable hardware, we develop a physiology- and quality-guided vibroacoustic sensing framework that effectively screens and refines TDoA for accurate stiffness estimation. We evaluate WAVES through characterization experiments using ballistic jelly and end-to-end on-body evaluation with human participants. Results demonstrate that WAVES can robustly estimate muscle stiffness across multiple users and different superficial muscles while enabling lightweight, wearable deployment for everyday use. WAVES is able to achieve a muscle stiffness estimation error of 13.1% or less across multiple users and multiple muscle groups.

Closest papers

Nearest neighbours by meaning across the whole index.

Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

cs.LG physics.med-phstat.AP ·2026-08-26 ·Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi +1 more
similarity 0.58
Abstract · 8 pages, 5 figures, 2 tables

As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

0.28

Uncertainty Quantification in Cardiac Model Personalisation from Ultrafast Ultrasound

cs.LG q-bio.QMphysics.med-ph ·2026-09-28 ·Camilla Ferrario, Maelys Venet, Olivier Villemain, Maxime Sermesant
top venueunusual similarity 0.57
Abstract

Cardiac model personalisation requires inferring mechanical parameters that are not directly measurable in vivo. Ultrafast ultrasound shear wave elastography (SWE) enables non-invasive tracking of myocardial stiffness dynamics over the cardiac cycle, providing a target for personalisation. However, mapping these observations to subject specific model parameters remains ill-posed, as multiple parameter sets can reproduce the same stiffness dynamics. We formulate SWE-informed personalisation as a statistical inference problem using simulation-based inference (SBI). Using a subject-adapted 0D cardiovascular model and neural posterior estimation, we estimate model-conditional posterior distributions over active stiffness scale k0, contraction rate kATP, and relaxation rate kSR, conditioned on SWE-derived curve features and subject specific context. Among six healthy volunteers, four passed objective prior-support diagnostics and were retained for quantitative posterior analysis. Curve-level RMSE against the observed SWE target decreased from 12.61 $\pm$ 5.55 kPa for the prior predictive median to 1.14 $\pm$ 0.38 kPa for the posterior predictive median, an 89.7 $\pm$ 4.2% reduction. Posterior analysis revealed parameter-specific uncertainty, k0-kATP compensation, weaker constraint of kSR, and the importance of prior-predictive diagnostics for assessing whether each subject is represented within the modelled SWE feature space. These results support SBI for uncertainty aware SWE-based personalisation, while identifying prior support and forward-model adequacy as key diagnostics.

0.43

A Mechanomyography-Based Integrated Sensing-Stimulation System for Fatigue-Aware Neuromuscular Therapy

cs.HC ·2026-10-11 ·Xiao Jin, Cong Liu, Zhenhua Yu
similarity 0.56
Abstract · 12 pages, 14 figures

Muscle fatigue limits the effectiveness of functional electrical stimulation (FES), yet fatigue monitoring during active stimulation remains challenging because electromyography (EMG) is severely contaminated by stimulation artifacts. To address this issue, this study proposes an integrated mechanomyography-based sensing framework (MMG-FES) for artifact-resistant fatigue monitoring during stimulation. Fatigue states were first characterized during voluntary movement using established EMG spectral indicators, including median frequency (MF) and mean power frequency (MPF), and then linked to MMG-derived features, including high-frequency energy ratio (HFER) and spectral bandwidth (BW), for fatigue recognition under stimulation conditions. Experimental results showed consistent fatigue-related trends, with EMG spectral features decreasing and MMG features exhibiting coordinated spectral redistribution across repeated contractions. Using these features, the proposed framework achieved fatigue-state recognition accuracies of 0.93 and 0.96 with logistic regression and random forest, respectively. These findings support MMG as a physiologically meaningful and stimulation-compatible modality for fatigue-aware closed-loop neuromuscular stimulation.

0.42

Ultrasound Elastography: Excitation Methods and Low-Cost Alternative

cs.CV eess.IV ·2026-11-11 ·Corin F. Otesteanu
published similarity 0.56
Abstract

Ultrasound elastography (or elasticity imaging) is a method that characterizes the tissue mechanical properties with the purpose of aiding the diagnosis of certain pathologies. Many novel clinical applications use the assumption that these tissue properties are changed in the presence of pathological processes. Characterization of tissue mechanical properties is achieved by imaging the response of the tissue to an induced stress or excitation. A plethora of approaches have been used in the scientific community to induce excitation in tissue, which usually require additional tools or devices than are costly. Furthermore these are usually integrated in the imaging pipeline using additional software or hardware for control. An alternative that is simpler, faster to integrate (and low-cost) is proposed in this work, by using readily available smartphones as a source of mechanical excitation. The induced displacements are used to solve the elasticity inverse problem (IP) using a finite element method (FEM) approach. Preliminary elasticity reconstructions of a phantom that mimics tissue are similar to when using a dedicated actuator as means of inducing harmonic displacements, illustrating the feasibility of our low-cost ultrasound elasography approach.

0.36

A Co-Located MMG-FES Wearable Interface for Action-Updated State-Gated Stimulation

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.55
Abstract · 9 pages, 8 figures. Submitted to IEEE Robotics and Automation Letters

Functional electrical stimulation (FES) assists movement, but fixed schedules cannot track how a repeatedly activated muscle changes, and surface electromyography (EMG) near the stimulation electrodes is often obscured by artifacts. Prior work recorded mechanomyography (MMG) passively during closed-loop FES cycling and estimated FES-induced fatigue or predicted fatigue for FES control, without gating stimulation with stimulated-site MMG. In this study, we present VG-FES, a wearable module co-locating microphone-based MMG, programmable charge-balanced biphasic stimulation, and embedded state-gated control at one on-skin thigh site. After each action, we compare rectus femoris (RF) mean power frequency (MPF) with an early-session baseline of the same direction, giving a relative state. A threshold on its window means enables fixed-duration bursts separated by rest periods. During onboard stimulation, MMG remained recordable, whereas near-site EMG was artifact-dominated. Under prolonged external stimulation, cycle-wise MMG tracked an independent local-pressure reference (Spearman rho = 0.968). In leave-one-session-out evaluation on 2284 squat actions (11 sessions, eight participants), MMG-based action segmentation reached an event-detection F1 of 0.923 and direction classification a balanced accuracy of 0.925. Online, over 15.69 min of self-paced squats, one participant received four bursts while MMG acquisition and action monitoring continued. Mechanical feedback from the stimulated site offers wearable FES and assistive robotics a per-action basis for state-gated stimulation.

0.40

Anticipatory Textile MMG-Strain Sensing for Confirm-Then-Assist Soft Knee Exosuits

cs.RO ·2026-10-11 ·Zheng Ma, Xiao Jin, Zhenhua Yu
similarity 0.54
Abstract · 8 pages, 9 figures, 4 tables

Soft wearable robots must commit to assistance around movement onset, when the available signals are ambiguous. Surface electromyography (sEMG) detects neuromuscular drive early but degrades under sweat and electrode shift, and kinematic sensors respond only once the limb moves. This letter presents a knitted textile interface that co-samples a three-channel mechanomyography (MMG) array and an anterior strain sensor on a single synchronous 500 Hz clock. Across five participants, MMG activation preceded strain-detected knee motion during sit-to-stand by per-channel medians of 322-344 ms. Sampled on the same clock, the sign of the strain slope resolved movement direction on 649 of 650 completed transitions with no training or per-participant calibration, raising four-class balanced accuracy from 90.3% to 95.6%. The fused signals drove a two-stage confirm-then-assist policy for a soft pneumatic knee. Across 240 trials in four participants, the onboard controller entered the assist state on 78 of 80 sit-to-stand trials and on none of the 80 isometric co-contractions. It also entered the assist state on 27 of 80 stand-to-sit trials and left it at the hold timeout, motivating an antagonistic flexor gauge to resolve this direction at onset. Co-sampling muscle acoustics with textile strain on one clock lets the inflation command be issued around movement onset.

0.37

Knit-Structure Effects on Electromechanical Metrics and Their Correlation with Joint-Angle Estimation Error in Knitted Strain Sensors

cs.HC ·2026-10-05 ·Annika Eloranta, Zhuchenyang Liu, Iiro Naulapaa, Iida Arvola, Yao Zhang +3 more
similarity 0.53
Abstract · 10 pages

Knitted resistive strain sensors show strong promise for joint motion sensing in sports and rehabilitation, but the linkage between sensor design and in situ performance remains unclear. We investigate how knit structure and machine settings (e.g., stitch size) shape electromechanical properties and which metrics predict sensing performance during bending. Sensors spanning seven common knit structures at two stitch sizes were fabricated, characterized under uniaxial cyclic tension, and evaluated on a joint emulating bending rig. Joint-angle estimation was assessed with machine learning models, and correlations with electromechanical metrics were analyzed. Experimental results show that, among six common metrics, gauge factor and baseline resistance are largely set by knit structure, while working range, linear range, hysteresis, and cyclic stability vary only modestly across designs. Gauge factor correlates negatively and baseline resistance positively with joint-angle estimation error, mainly in lower-sensitivity designs, whereas the other metrics have weak or no predictive value. These results support using uniaxial tensile tests to screen out weak designs, while underscoring the need for joint-relevant evaluation and application-specific metrics to identify top performers.

0.40

Physics-Constrained Deep Learning Model for Contactless Blood Pressure Monitoring from Triaxial Bodyseismography

eess.SP cs.AIphysics.bio-ph ·2026-08-24 ·Yuanyuan Zhang, Yida Zhang, Jiahui Li, Yuyan Wu, Fei Dou +4 more
similarity 0.52
Abstract

Ballistocardiography (BCG) is promising for unobtrusive long-term blood pressure (BP) monitoring in laboratory settings, but traditional BCG signals are vulnerable to the variations in body-bed interaction with shifted fiducial points in temporal or amplitude axis, and BP varies with personal hemodynamic changes, causing misaligned representations that affect model generalizability and robustness. In this work, we propose Phy-BP, a physics-constrained BP estimation framework based on triaxial bodyseismography (BSG) acquired using bed-mounted sensors as an extension of single-axis BCG. Firstly, we design an adaptive quality-control algorithm combining neighboring beat patterns and universal cardiogenic templates to retain reliable cardiac components. Secondly, we propose a physical model of wave propagation through the body-bed system to constrain latent feature evolution, aligning triaxial representations generated by a shared cardiogenic excitation. These mechanical constraints connect multi-axis feature learning to body-bed dynamics and complement data-driven regression from vibration signals. Evaluation on a 162-hour hospital dataset from 21 subjects against invasive arterial BP yields a mean absolute error of 5.07 mmHg, a prediction-error standard deviation of 7.24 mmHg, and a Pearson correlation coefficient of 0.86 for mean arterial pressure. This framework is intended for unobtrusive monitoring during rest and sleep, with potential applications in overnight hospital and home monitoring.

0.43