CS Paper Radar

Uncertainty Quantification in Cardiac Model Personalisation from Ultrafast Ultrasound

Camilla Ferrario, Maelys Venet, Olivier Villemain, Maxime Sermesant

cs.LG q-bio.QMphysics.med-ph ·submitted 2026-09-28 14:04 UTC · v1
top venueunusual

Abstract

Cardiac model personalisation requires inferring mechanical parameters that are not directly measurable in vivo. Ultrafast ultrasound shear wave elastography (SWE) enables non-invasive tracking of myocardial stiffness dynamics over the cardiac cycle, providing a target for personalisation. However, mapping these observations to subject specific model parameters remains ill-posed, as multiple parameter sets can reproduce the same stiffness dynamics. We formulate SWE-informed personalisation as a statistical inference problem using simulation-based inference (SBI). Using a subject-adapted 0D cardiovascular model and neural posterior estimation, we estimate model-conditional posterior distributions over active stiffness scale k0, contraction rate kATP, and relaxation rate kSR, conditioned on SWE-derived curve features and subject specific context. Among six healthy volunteers, four passed objective prior-support diagnostics and were retained for quantitative posterior analysis. Curve-level RMSE against the observed SWE target decreased from 12.61 $\pm$ 5.55 kPa for the prior predictive median to 1.14 $\pm$ 0.38 kPa for the posterior predictive median, an 89.7 $\pm$ 4.2% reduction. Posterior analysis revealed parameter-specific uncertainty, k0-kATP compensation, weaker constraint of kSR, and the importance of prior-predictive diagnostics for assessing whether each subject is represented within the modelled SWE feature space. These results support SBI for uncertainty aware SWE-based personalisation, while identifying prior support and forward-model adequacy as key diagnostics.

Journal ref
Statistical Atlases and Computational Modelling of the Heart (STACOM), MICCAI 2026., Sep 2026, Strasbourg, France

Closest papers

Nearest neighbours by meaning across the whole index.

WAVES: Wearable Active Vibroacoustic Elasticity Sensing for Low-Cost and Non-Invasive Muscle Stiffness Monitoring

cs.ET ·2026-11-04 ·Shubham Rohal, Dong Yoon Lee, Shijia Pan
similarity 0.57
Abstract

Muscle stiffness is a physiologically meaningful biomarker associated with a wide range of musculoskeletal and neurological conditions. However, existing muscle stiffness assessment methods, such as shear wave elastography (SWE), manual palpation, and handheld mechanical probes, remain impractical for continuous, everyday monitoring due to bulky hardware, operator dependence, and limited self-use. Meanwhile, wearable muscle-sensing modalities such as Electromyography (EMG) and Mechanomyography (MMG) primarily capture muscle activation rather than passive mechanical properties of tissue at rest, leaving a critical gap in portable monitoring of resting muscle stiffness. In this work, we present WAVES, a wearable system for continuous monitoring of muscle stiffness via active vibroacoustic sensing. WAVES injects controlled vibroacoustic excitation into soft tissue and estimates muscle stiffness by measuring shear-wave propagation velocity through Time-Difference-of-Arrival (TDoA) analysis across spatially distributed wearable sensors. To achieve accurate TDoA estimation with low-cost wearable hardware, we develop a physiology- and quality-guided vibroacoustic sensing framework that effectively screens and refines TDoA for accurate stiffness estimation. We evaluate WAVES through characterization experiments using ballistic jelly and end-to-end on-body evaluation with human participants. Results demonstrate that WAVES can robustly estimate muscle stiffness across multiple users and different superficial muscles while enabling lightweight, wearable deployment for everyday use. WAVES is able to achieve a muscle stiffness estimation error of 13.1% or less across multiple users and multiple muscle groups.

0.25

Personalized and Explainable Blood Pressure Estimation from PPG via Hybrid CNN--Morphological Features

cs.CV ·2026-08-11 ·Myung-Kyu Yi, Jongshill Lee, Jeyeon Lee, In Young Kim
published similarity 0.55
Abstract

Continuous cuffless blood pressure (BP) monitoring using photoplethysmography (PPG) offers a promising solution for personalized healthcare. However, existing methods have two major limitations. Handcrafted feature-based approaches rely on precise fiducial point detection and are limited to short-term analysis, while deep learning models, despite their accuracy, often operate as black boxes with limited physiological interpretability. To address these challenges, we propose a physiology-guided hybrid framework for personalized BP estimation that couples a convolutional neural network (CNN) branch capturing global and local waveform dynamics with a morphology-prior branch that explicitly encodes person-specific vascular characteristics. By embedding a morphology-based feature set that explicitly encodes individual vascular characteristics, the proposed framework enhances personalization and reduces dependence on large-scale training datasets. Evaluated on a subset of the MIMIC-III database under a subject-specific (personalized) testing protocol, the proposed personalized physiology-guided hybrid approach achieved mean absolute errors (MAEs) of 3.77 mmHg for systolic BP and 2.36 mmHg for diastolic BP, corresponding to relative improvements of 43.7% and 32.4% over a subject-specific (personalized) CNN-only baseline. SHAP-based analysis confirmed that the introduced morphology-prior features align with individual vascular characteristics, reinforcing per-subject interpretability. These findings highlight the potential of personalized, physiology-guided hybrid learning with novel morphological descriptors for accurate and explainable BP monitoring in real-world settings.

0.57

Physics-Constrained Deep Learning Model for Contactless Blood Pressure Monitoring from Triaxial Bodyseismography

eess.SP cs.AIphysics.bio-ph ·2026-08-24 ·Yuanyuan Zhang, Yida Zhang, Jiahui Li, Yuyan Wu, Fei Dou +4 more
similarity 0.55
Abstract

Ballistocardiography (BCG) is promising for unobtrusive long-term blood pressure (BP) monitoring in laboratory settings, but traditional BCG signals are vulnerable to the variations in body-bed interaction with shifted fiducial points in temporal or amplitude axis, and BP varies with personal hemodynamic changes, causing misaligned representations that affect model generalizability and robustness. In this work, we propose Phy-BP, a physics-constrained BP estimation framework based on triaxial bodyseismography (BSG) acquired using bed-mounted sensors as an extension of single-axis BCG. Firstly, we design an adaptive quality-control algorithm combining neighboring beat patterns and universal cardiogenic templates to retain reliable cardiac components. Secondly, we propose a physical model of wave propagation through the body-bed system to constrain latent feature evolution, aligning triaxial representations generated by a shared cardiogenic excitation. These mechanical constraints connect multi-axis feature learning to body-bed dynamics and complement data-driven regression from vibration signals. Evaluation on a 162-hour hospital dataset from 21 subjects against invasive arterial BP yields a mean absolute error of 5.07 mmHg, a prediction-error standard deviation of 7.24 mmHg, and a Pearson correlation coefficient of 0.86 for mean arterial pressure. This framework is intended for unobtrusive monitoring during rest and sleep, with potential applications in overnight hospital and home monitoring.

0.42

When2What: A Timing-Conditioned Framework for Long-Horizon Forecasting of Continuous Cardiovascular Waveforms

cs.LG ·2026-11-06 ·Chaoqi Zhang, Shujie Yan, Zhao Zhang, Yanhua Sun, Yu Wang +4 more
code/data similarity 0.54
Abstract · 31 pages (18 pages main text, 13 pages supplementary material), 7 figures, 31 tables. Code available at https://github.com/prncoprs/when2wha…

Long-horizon forecasting of quasi-periodic cardiovascular waveforms, such as the electrocardiogram (ECG), arterial blood pressure (ABP), and photoplethysmogram (PPG), requires predicting both when future cardiac events will occur (beat timing) and what the local structural pattern looks like around each event (beat morphology). However, standard sequence forecasters trained with pointwise mean squared error (MSE) average across uncertain future heartbeat phases, flattening sharp R peaks and pulse upstrokes into featureless baselines. Our analysis of intraoperative ECG reveals a clear temporal asymmetry: beat-time predictability from history decays within seconds due to stochastic heart-rate variability, whereas local beat morphology aligned at true beat times remains stable over several minutes. Guided by this insight, we introduce When2What, a timing-conditioned framework comprising three stages: Predict, Commit, and Generate. Given a 120-s history, When2What predicts a dense 60-s timing map, selects and sharpens discrete beat events into unit-height Gaussian impulses, and conditions a neural waveform generator on both these committed events and the observed history. Across intraoperative ECG, When2What substantially outperforms existing time-series and physiological forecasters, achieving a near-term waveform event skill of 0.644 and reproducing 95.62% of its predicted heartbeats in the generated waveform where direct long-horizon forecasters collapse into flat baselines. Furthermore, When2What transfers zero-shot to external hospital and atrial fibrillation cohorts, extends effectively to ABP and PPG pulse waveforms, and is supported by ablations and synthetic analyses that establish explicit timing conditioning as an effective paradigm for quasi-periodic long-horizon waveform forecasting.

0.27

Bodyseismography (BSG): Theoretical Foundation and Numerical Modeling

eess.SP physics.med-ph ·2026-10-26 ·Yuanyuan Zhang, Yuyan Wu, Sahas Biddappa, Yida Zhang, Jiayu Chen +8 more
similarity 0.54
Abstract · Yuanyuan Zhang and Yuyan Wu contributed equally and share first authorship

Bodyseismography (BSG) records cardiovascular vibrations transmitted through the body and a supporting bed, enabling contactless assessment of cardiac mechanics. Relating these vibrations to hemodynamic features requires separating cardiac excitation from the effects of body and bed transmission. We develop a source-transmission-measurement framework that couples myocardial contraction and vascular recoil to directional BSG observations. The theory connects stroke volume, cardiac output, and blood pressure to observation and target Jacobians, establishes a local first-order target-observability criterion, and characterizes how additional sensing axes reduce ambiguities under specified source and transmission uncertainties. Numerical modeling combines four-chamber cardiac mechanics, cardiac-to-body excitation, and calibrated body-bed operators. Across 27 participants, a multilayer finite-element model with calibrated frequency correction achieves median Pearson correlation coefficients of 0.865 for the vertical channel and 0.682 for the planar-sum channel in matched-window waveform reconstruction. Controlled stroke-volume perturbations show that transmission reshapes feature sensitivity, including a reversal of the vertical feature association in 8 of 27 participant-specific transfer models. These analytical and numerical studies explain how cardiovascular sources and mechanical propagation jointly shape triaxial BSG and provide a physical basis for relating directional vibration features to hemodynamic changes.

0.23

Adaptive Uncertainty-Aware Modeling and Stochastic Radial Basis Function Predictive Control for Personalized Fluid Resuscitation

eess.SY cs.LG ·2026-09-18 ·Elham Estiri, Hossein Mirinejad
similarity 0.53
Abstract

This paper presents a novel framework integrating Bayesian physiological modeling with optimal control strategies to achieve uncertainty-aware, personalized hemodynamic regulation during fluid resuscitation. An uncertainty-aware variational autoencoder state-space model (UVAE-SSM) was first developed to capture the dynamical relationship between mean arterial pressure (MAP) and fluid infusion using limited data, while explicitly modeling aleatoric uncertainty (i.e., randomness in the measurements, such as sensor noise). Then, a Bayesian nonlinear state-space model (BNSSM) was developed by utilizing Bayesian neural networks (BNNs) to capture epistemic uncertainty arising from physiological and patient-specific variability, enabling the creation of a virtual patient generator (VPG). Building on this uncertainty-aware modeling framework, a stochastic radial basis function model predictive control (sRBF-MPC) algorithm was designed to track the MAP target while satisfying physiological constraints. Finally, an online fine-tuning algorithm was developed to adapt the nominal UVAE-SSM using streaming VPG data, enabling progressive personalization during closed-loop therapy. Simulation results across unseen animal subjects and an independent human clinical dataset demonstrated the strong predictive accuracy and cross-population generalizability of the UVAE-SSM and BNSSM models. Closed-loop evaluations confirmed that the proposed sRBF-MPC framework achieved stable MAP regulation while providing better risk-aware control compared to quadratic MPC (Q-MPC) and stochastic quadratic MPC (sQ-MPC). Overall, the proposed framework accounts for inter- and intra-patient variability through online model adaptation, offering a promising step toward uncertainty-aware, personalized hemodynamic modeling and control in critical care.

0.26

Myocardial Strain Drift Correction in Deep Learning Based Ultrasound Tracking

eess.IV cs.AIcs.CV ·2026-09-09 ·Thierry Judge, Nicolas Duchateau, Andreas Østvik, Havard Dalen, Bjørnar Grenne +4 more
similarity 0.53
Abstract · STACOM 2026, 10 pages

Myocardial strain from echocardiography is a key biomarker for cardiac function. Recent deep learning methods show strong performance for myocardial motion tracking but often lack physiological constraints, leading to temporal drift across the cardiac cycle. Consequently, tracked points may not return to their relative initial positions at the end of each cardiac cycle, producing inaccurate strain estimates and even divergence in some cases. We propose a deep learning framework that compensates for drift during myocardial tracking. We extend a state-of-the-art echocardiographic tracking method (TAS-Net) with persistent memory tokens that share information across sliding windows over full cardiac cycles. A teacher-student fine-tuning strategy on real echocardiographic data then enforces physiologically consistent cyclic motion while preserving tracking accuracy. Experiments show reduced global and regional strain drift, improved agreement with clinical references, and better test-retest reproducibility, supporting more reliable myocardial strain estimation in clinical practice.

0.37

Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review

eess.IV physics.med-ph ·2026-08-23 ·Can Deniz Bezek, Orcun Goksel
survey similarity 0.53
Abstract

Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging.

0.28