Bodyseismography (BSG): Theoretical Foundation and Numerical Modeling

Yuanyuan Zhang, Yuyan Wu, Sahas Biddappa, Yida Zhang, Jiayu Chen, Zixuan Zeng, Yixuan Li, Jiahui Li, Fei Dou, Zhenlin An, Younghoon Kwon, Hae Young Noh, WenZhan Song

eess.SP physics.med-ph ·submitted 2026-10-26 17:55 UTC · v3

Abstract

Bodyseismography (BSG) records cardiovascular vibrations transmitted through the body and a supporting bed, enabling contactless assessment of cardiac mechanics. Relating these vibrations to hemodynamic features requires separating cardiac excitation from the effects of body and bed transmission. We develop a source-transmission-measurement framework that couples myocardial contraction and vascular recoil to directional BSG observations. The theory connects stroke volume, cardiac output, and blood pressure to observation and target Jacobians, establishes a local first-order target-observability criterion, and characterizes how additional sensing axes reduce ambiguities under specified source and transmission uncertainties. Numerical modeling combines four-chamber cardiac mechanics, cardiac-to-body excitation, and calibrated body-bed operators. Across 27 participants, a multilayer finite-element model with calibrated frequency correction achieves median Pearson correlation coefficients of 0.865 for the vertical channel and 0.682 for the planar-sum channel in matched-window waveform reconstruction. Controlled stroke-volume perturbations show that transmission reshapes feature sensitivity, including a reversal of the vertical feature association in 8 of 27 participant-specific transfer models. These analytical and numerical studies explain how cardiovascular sources and mechanical propagation jointly shape triaxial BSG and provide a physical basis for relating directional vibration features to hemodynamic changes.

Comment
Yuanyuan Zhang and Yuyan Wu contributed equally and share first authorship

Closest papers

Nearest neighbours by meaning across the whole index.

Physics-Constrained Deep Learning Model for Contactless Blood Pressure Monitoring from Triaxial Bodyseismography

eess.SP cs.AIphysics.bio-ph ·2026-08-24 ·Yuanyuan Zhang, Yida Zhang, Jiahui Li, Yuyan Wu, Fei Dou +4 more
similarity 0.66
Abstract

Ballistocardiography (BCG) is promising for unobtrusive long-term blood pressure (BP) monitoring in laboratory settings, but traditional BCG signals are vulnerable to the variations in body-bed interaction with shifted fiducial points in temporal or amplitude axis, and BP varies with personal hemodynamic changes, causing misaligned representations that affect model generalizability and robustness. In this work, we propose Phy-BP, a physics-constrained BP estimation framework based on triaxial bodyseismography (BSG) acquired using bed-mounted sensors as an extension of single-axis BCG. Firstly, we design an adaptive quality-control algorithm combining neighboring beat patterns and universal cardiogenic templates to retain reliable cardiac components. Secondly, we propose a physical model of wave propagation through the body-bed system to constrain latent feature evolution, aligning triaxial representations generated by a shared cardiogenic excitation. These mechanical constraints connect multi-axis feature learning to body-bed dynamics and complement data-driven regression from vibration signals. Evaluation on a 162-hour hospital dataset from 21 subjects against invasive arterial BP yields a mean absolute error of 5.07 mmHg, a prediction-error standard deviation of 7.24 mmHg, and a Pearson correlation coefficient of 0.86 for mean arterial pressure. This framework is intended for unobtrusive monitoring during rest and sleep, with potential applications in overnight hospital and home monitoring.

0.43

Impact of Multiple Non-Invasive Biosignals on Cardiovascular Biomarker Estimation via Simulation-Based Inference

cs.LG physics.med-phstat.AP ·2026-08-26 ·Shusaku Maeda, Masahiro Nakano, Tomoharu Iwata, Kenji Komiya, Ryo Nishikimi +1 more
similarity 0.57
Abstract · 8 pages, 5 figures, 2 tables

As the population ages, the number of patients with cardiovascular diseases continues to increase, highlighting the need for early detection before progression to severe and irreversible functional decline. Consequently, estimating cardiovascular biomarkers from non-invasive biosignals, such as photoplethysmography (PPG) and arterial pressure wave (APW) signals, has attracted increasing attention. These signals can be measured using wearable and cuff-type devices. Previous studies have used PPG and APW signals to estimate cardiovascular biomarkers. However, these signals exhibit strong similarities in both the temporal and frequency domains and primarily reflect peripheral and arterial pulse waveforms. Therefore, they may provide limited information about cardiac mechanical function. In contrast, the quantitative impact of additional biosignals, such as ballistocardiography (BCG), which reflect the body's minute mechanical responses to cardiac ejection, remains unclear. In this study, we generated synthetic PPG, APW, and BCG signals from a unified whole-body cardiovascular circulation model and evaluated the complementary contribution of BCG to probabilistic cardiovascular biomarker estimation. We estimated posterior distributions of cardiovascular biomarkers using neural posterior estimation and simulation-based inference. The results showed that adding BCG signals significantly improved estimation performance. Furthermore, even in ill-posed cases where PPG and APW alone produced multimodal posterior distributions, adding BCG yielded unimodal posterior distributions. These findings provide fundamental insights into signal selection for estimating cardiovascular dynamics.

0.28

A Synchronized Tri-Modality Wireless System for Multi-Point Non-Contact Cardiac Monitoring

cs.AR eess.SPeess.SY ·2026-11-05 ·Wei Ren, Kaili Zhao, Huansheng Yi, Miaoyang Hu, Jianqi Wang +2 more
similarity 0.55
Abstract · 11 pages, 9 figures

Cardiac physiological monitoring is fundamental to evaluating cardiovascular health and diagnosing related diseases. Non-contact radar sensing can capture chest-wall vibrations with spatial specificity, enabling localized physiological monitoring and cardiac assessment. Progress, however, has been limited by the absence of a reliable, research-grade hardware platform for rigorous validation of radar-based methods. Prior systems typically pair radar, namely Doppler cardiography (DCG), with only electrocardiography (ECG) or other coarse references, providing no direct mechanical ground truth and thus constraining fine-grained evaluation of radar outputs. We present a tri-modality wireless system that integrates ECG, seismocardiography (SCG), and DCG under a unified acquisition and control framework for time-aligned recording and analysis. The tri-modality system combines miniaturized wearable ECG/SCG modules with a high-resolution mmWave radar module, supporting spatially resolved sensing and subsequent feature extraction. To our knowledge, this is the first integrated ECG--SCG--DCG hardware system for comprehensive cardiac monitoring; it enables multi-point thoracic acquisition, achieves precise cross-modal synchronization, and maintains specifications suitable for wearable operation. Experiments on a linear-motion platform show close agreement between DCG- and SCG-derived displacements, confirming accurate displacement measurement. Human-subject studies further demonstrate cross-modal consistency and robust extraction of feature points, establishing ECG as the electrical anchor and SCG as the mechanical ground truth for DCG. Overall, the system provides a rigorous, spatially resolved validation platform that advances non-contact cardiac sensing and supports next-generation radar-based monitoring.

0.24

A Bifurcation-Based Domain Decomposition Method with Neural Operators for Blood Flow Simulation

cs.CE physics.comp-ph ·2026-09-29 ·Yuzhou Zhao, Han Zhang, J. Matias Di Martino, Jean-Michel Morel, Guillermo Sapiro
published similarity 0.54
Abstract · Accepted for publication in Multiscale Modeling & Simulation (SIAM)

Fast and accurate simulation of hemodynamic behavior within vascular networks is essential for numerous clinical applications. However, obtaining high-quality and computationally efficient flow measurements across complex vascular networks remains challenging. To address this, we first decompose the vascular network into a set of bifurcation units and then develop an operator network capable of mapping unit-specific parameters to the local solution fields of each bifurcation unit. By lumping the Windkessel-model outlet parameters and incorporating inlet boundary conditions from the solution of parent units, the flow and pressure fields can be rapidly approximated. Subsequently, operator-network-driven Schwarz waveform relaxation is applied across bifurcation units to correct discontinuities and improve numerical accuracy. On 7-segment and 55-segment arterial tree models, the proposed method achieves $13\times$ to $17\times$ wall-clock speedups over conventional 1D numerical simulation, with relative $L^2$ errors of 1% in both pressure and velocity. The resulting pulse wave velocity biomarkers agree with the conventional reference to within 1--2%, and the same trained operator generalizes to different tree-like 1D vascular network topologies.

0.25

Uncertainty Quantification in Cardiac Model Personalisation from Ultrafast Ultrasound

cs.LG q-bio.QMphysics.med-ph ·2026-09-28 ·Camilla Ferrario, Maelys Venet, Olivier Villemain, Maxime Sermesant
top venueunusual similarity 0.54
Abstract

Cardiac model personalisation requires inferring mechanical parameters that are not directly measurable in vivo. Ultrafast ultrasound shear wave elastography (SWE) enables non-invasive tracking of myocardial stiffness dynamics over the cardiac cycle, providing a target for personalisation. However, mapping these observations to subject specific model parameters remains ill-posed, as multiple parameter sets can reproduce the same stiffness dynamics. We formulate SWE-informed personalisation as a statistical inference problem using simulation-based inference (SBI). Using a subject-adapted 0D cardiovascular model and neural posterior estimation, we estimate model-conditional posterior distributions over active stiffness scale k0, contraction rate kATP, and relaxation rate kSR, conditioned on SWE-derived curve features and subject specific context. Among six healthy volunteers, four passed objective prior-support diagnostics and were retained for quantitative posterior analysis. Curve-level RMSE against the observed SWE target decreased from 12.61 $\pm$ 5.55 kPa for the prior predictive median to 1.14 $\pm$ 0.38 kPa for the posterior predictive median, an 89.7 $\pm$ 4.2% reduction. Posterior analysis revealed parameter-specific uncertainty, k0-kATP compensation, weaker constraint of kSR, and the importance of prior-predictive diagnostics for assessing whether each subject is represented within the modelled SWE feature space. These results support SBI for uncertainty aware SWE-based personalisation, while identifying prior support and forward-model adequacy as key diagnostics.

0.43

SSEMG-Net: A Spectrogram-Based Mamba Network for Surface Electromyography Denoising

eess.SP ·2026-09-10 ·Cheng-Han Shih, Kuan-Chen Wang, Kai-Chun Liu, Ping-Cheng Yeh, Yu Tsao
published similarity 0.53
Abstract · 6 pages, 3 figures, 2 tables. Presented at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society …

Electrocardiogram (ECG) artifact contamination frequently occurs in surface electromyography (sEMG) when muscles are recorded near the heart. Existing neural network (NN)-based approaches typically perform waveform-level end-to-end denoising with pointwise losses, but often fail to preserve the spectral structures of sEMG. In addition, these models do not exploit the prior knowledge that ECG mainly distorts the low-frequency band of sEMG. We propose SSEMG-Net, a spectrogram-domain model that explicitly captures sEMG-ECG interactions using a bidirectional Mamba backbone and a dual-head decoder for magnitude masking and wrapped-phase estimation. The magnitude masking module is physiologically aware, restricting denoising to the low-frequency sub-band where ECG activity predominates. Experimental results demonstrate that SSEMG-Net achieves superior signal quality and lower feature-extraction error compared to prior methods, underscoring its potential for clinical applications where preserving sEMG spectral features is essential.

0.44

WAVES: Wearable Active Vibroacoustic Elasticity Sensing for Low-Cost and Non-Invasive Muscle Stiffness Monitoring

cs.ET ·2026-11-04 ·Shubham Rohal, Dong Yoon Lee, Shijia Pan
similarity 0.52
Abstract

Muscle stiffness is a physiologically meaningful biomarker associated with a wide range of musculoskeletal and neurological conditions. However, existing muscle stiffness assessment methods, such as shear wave elastography (SWE), manual palpation, and handheld mechanical probes, remain impractical for continuous, everyday monitoring due to bulky hardware, operator dependence, and limited self-use. Meanwhile, wearable muscle-sensing modalities such as Electromyography (EMG) and Mechanomyography (MMG) primarily capture muscle activation rather than passive mechanical properties of tissue at rest, leaving a critical gap in portable monitoring of resting muscle stiffness. In this work, we present WAVES, a wearable system for continuous monitoring of muscle stiffness via active vibroacoustic sensing. WAVES injects controlled vibroacoustic excitation into soft tissue and estimates muscle stiffness by measuring shear-wave propagation velocity through Time-Difference-of-Arrival (TDoA) analysis across spatially distributed wearable sensors. To achieve accurate TDoA estimation with low-cost wearable hardware, we develop a physiology- and quality-guided vibroacoustic sensing framework that effectively screens and refines TDoA for accurate stiffness estimation. We evaluate WAVES through characterization experiments using ballistic jelly and end-to-end on-body evaluation with human participants. Results demonstrate that WAVES can robustly estimate muscle stiffness across multiple users and different superficial muscles while enabling lightweight, wearable deployment for everyday use. WAVES is able to achieve a muscle stiffness estimation error of 13.1% or less across multiple users and multiple muscle groups.

0.25

Cylindrical Geodesic Flow Matching for Quasiperiodic Physiological Signal Transformation

cs.AI ·2026-10-06 ·Onur Selim Kilic, Afra Nawar, Cem Okan Yaldiz, Michael J. Cho, Ahmet Rasim Emirdagi +4 more
similarity 0.52
Abstract

Paired translation between quasiperiodic physiological waveforms (i.e., recovering a target oscillatory signal from the source) is central to the interpretation of cardiovascular signals derived from wearables placed at different body locations. This source-to-target mapping in these problems carries inherent geometric structure: the phase wraps around the cycle and must be treated as a circular variable, the amplitude remains strictly positive, and the beat-to-beat alignment can drift unpredictably across cycles and subjects. While deep neural networks have been used for phase estimation and complex-valued signal modeling, prior work does not explicitly learn phase transport between paired signals. Consequently, neither endpoint-supervised regression nor the standard affine path used in flow matching accounts for this phase--amplitude structure. We introduce \emph{cylindrical geodesic flow matching} for paired cardiovascular waveform translation. We show that the standard affine path used in flow matching distorts intermediate amplitude and instantaneous frequency when interpolating between quasiperiodic signals; replacing it with a closed-form geodesic on the phase--amplitude cylinder eliminates these artifacts and converts each training pair into dense, geometry-consistent velocity supervision. On zero-shot photoplethysmography and limited-support seismocardiography adaptation benchmarks, our method consistently outperforms interpolation baselines and matches or exceeds direct supervised prediction, reducing Hilbert Transform, $L_2$, and Dynamic Time Warping distance by up to ${\sim}15\%$ over the strongest competing baseline. These results suggest that bridge geometry is a critical inductive bias for flow matching on oscillatory signal translation.

0.30