CS Paper Radar

Knit-Structure Effects on Electromechanical Metrics and Their Correlation with Joint-Angle Estimation Error in Knitted Strain Sensors

Annika Eloranta, Zhuchenyang Liu, Iiro Naulapaa, Iida Arvola, Yao Zhang, Anna-Mari Leppisaari, Lulu Xu, Yu Xiao

cs.HC ·submitted 2026-10-05 21:27 UTC · v1

Abstract

Knitted resistive strain sensors show strong promise for joint motion sensing in sports and rehabilitation, but the linkage between sensor design and in situ performance remains unclear. We investigate how knit structure and machine settings (e.g., stitch size) shape electromechanical properties and which metrics predict sensing performance during bending. Sensors spanning seven common knit structures at two stitch sizes were fabricated, characterized under uniaxial cyclic tension, and evaluated on a joint emulating bending rig. Joint-angle estimation was assessed with machine learning models, and correlations with electromechanical metrics were analyzed. Experimental results show that, among six common metrics, gauge factor and baseline resistance are largely set by knit structure, while working range, linear range, hysteresis, and cyclic stability vary only modestly across designs. Gauge factor correlates negatively and baseline resistance positively with joint-angle estimation error, mainly in lower-sensitivity designs, whereas the other metrics have weak or no predictive value. These results support using uniaxial tensile tests to screen out weak designs, while underscoring the need for joint-relevant evaluation and application-specific metrics to identify top performers.

Comment
10 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Anticipatory Textile MMG-Strain Sensing for Confirm-Then-Assist Soft Knee Exosuits

cs.RO ·2026-10-11 ·Zheng Ma, Xiao Jin, Zhenhua Yu
similarity 0.66
Abstract · 8 pages, 9 figures, 4 tables

Soft wearable robots must commit to assistance around movement onset, when the available signals are ambiguous. Surface electromyography (sEMG) detects neuromuscular drive early but degrades under sweat and electrode shift, and kinematic sensors respond only once the limb moves. This letter presents a knitted textile interface that co-samples a three-channel mechanomyography (MMG) array and an anterior strain sensor on a single synchronous 500 Hz clock. Across five participants, MMG activation preceded strain-detected knee motion during sit-to-stand by per-channel medians of 322-344 ms. Sampled on the same clock, the sign of the strain slope resolved movement direction on 649 of 650 completed transitions with no training or per-participant calibration, raising four-class balanced accuracy from 90.3% to 95.6%. The fused signals drove a two-stage confirm-then-assist policy for a soft pneumatic knee. Across 240 trials in four participants, the onboard controller entered the assist state on 78 of 80 sit-to-stand trials and on none of the 80 isometric co-contractions. It also entered the assist state on 27 of 80 stand-to-sit trials and left it at the hold timeout, motivating an antagonistic flexor gauge to resolve this direction at onset. Co-sampling muscle acoustics with textile strain on one clock lets the inflation command be issued around movement onset.

0.37

A Unified Kinematic Representation Enables Reusable Biological Joint Moment Estimation

cs.RO ·2026-10-06 ·Jinwoo Hwang, Ilseung Park, Changseob Song, Vu Phan, Eni Halilaj +1 more
code/data similarity 0.60
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

Objective: Data-driven models that estimate physiological states, particularly biological joint moments, are widely used in exoskeleton control. However, these estimators are often coupled to device-specific sensor configurations, limiting controller transfer and the use of open-source biomechanics datasets. Methods: We proposed joint kinematics as an intermediate representation that decouples hardware-specific sensing from downstream biological joint moment estimation. A joint-moment estimator using joint angles and angular velocities was trained exclusively on open-source biomechanics data and evaluated using kinematics from a hip exoskeleton, knee exoskeleton, and inertial measurement unit (IMU) sensor suite during level-ground, ramp-ascent, and ramp-descent walking. Results: The estimator achieved an root mean square error (RMSE) of 0.17 Nm/kg and coefficient of determination (R2) of 0.79 using hip exoskeleton kinematics, 0.19 Nm/kg and 0.62 using knee exoskeleton kinematics, and 0.15 Nm/kg and 0.85 using kinematics derived from IMUs across bilateral hip, knee, and ankle joints. Conclusion: Joint kinematics enabled an estimator trained only on open-source data to operate across distinct wearable platforms. Significance: This framework may reduce target-device data collection and support transferable biological joint moment estimation for exoskeleton control and wearable biomechanics.

0.48

Design and Control of a Cable-Driven Switchable Actuator with Torque/Tension Dual Modes for Exoskeletons

cs.RO eess.SY ·2026-09-20 ·YuanLong Ji, Xu Liu, Xinyuan Cai, Qihan Ye, Xiangyu Xie +6 more
top venue similarity 0.57
Abstract

Existing wearable exoskeleton architectures are typically constrained by a single mechanical output modality, providing either joint torque around an anatomical joint or linear traction along a limb-training-oriented direction, which limits adaptability to diverse training scenarios. This letter presents a cable-driven switchable actuator (CDSA) that can rapidly switch between torque and tension modes while centralizing all sensing and actuation components at the proximal drive unit. A Coupled Movable Pulley Mechanism (CMPM) provides tension amplification at the distal end-effector, while a bidirectional Cable-Driven Ratchet Mechanism (CDRM) enables mode switching and preload regulation. To eliminate the need for distal instrumentation, multi-source proximal sensors are integrated with a data-driven fusion model to estimate distal output forces. An adaptive dual-mode force control strategy based on iterative learning control (ILC) is further developed. Platform experiments demonstrate transmission efficiencies of $(92.4 \pm 2.0)\%$ and $(96.5 \pm 3.3)\%$ in the torque and tension modes, respectively, along with a tension amplification ratio of $2.77 \pm 0.10$ under tension mode. Tracking tests on simulated knee-joint gait trajectories and short-stroke tension profiles yield stable control, with RMSEs of $(4.52 \pm 0.51)\%$ and $(3.15 \pm 0.19)\%$ of the uncontrolled peak value, respectively. Finally, seated human-coupled experiments validate the system's controllable force generation in both joint-torque and linear-traction application modes.

0.40

Reliable Piezoresistive Strain Sensing Through Physical Limits and Uncertainty Monitoring

cs.RO ·2026-08-16 ·Carmen Ballester, Víctor Muñoz, Dorin Copaci, Dolores Blanco
similarity 0.57
Abstract

Soft piezoresistive strain sensors are one of the most common sensing solutions for wearable and soft robotic applications due to their flexibility and compliance. However, their resistance response is nonlinear and hysteretic, and a sensor can be pushed past its calibrated workspace or misbehave inside it, carrying that error into a decision or control loop. Probabilistic regressors track confidence but ignore those limits. A predictive mean can look unremarkable even when the reading comes from a sensor outside its admissible range or already failing internally, so a confident-looking estimate is not the same as a trustworthy one. This paper proposes a reliability framework pairing a physics-informed probabilistic inverse model, built on physics-guided input features, with a risk factor fusing uncertainty with strain and strain-rate limits into a three-state monitor. Tests on a Nitinol wire and a silver-coated polyamide thread with a Gaussian Process raised fit scores to 0.90-0.95 (RMSE 0.26%-0.15%) and a 96% empirical coverage against the 95% target. The monitor caught 95% of out-of-range and 100% of abnormal conditions while staying reliable under nominal operation. A sensor that reports confidence alongside its estimate lets a system withhold action instead, since it needs no labeled failure examples, which are hard to collect for soft materials.

0.04

SaddleSense: Saddle-Shaped Modules for 3D Shape Sensing with Single-Axis Off-the-Shelf Bend Sensors

cs.RO ·2026-10-31 ·Dong Heon Han, Runze Zuo, Chankyo Kim, Saima Jamal, Daniel Bruder
similarity 0.56
Abstract

Accurate posture feedback is essential for precise control of continuum robots. Off-the-shelf bend sensors measure curvature about only one axis; without a suitable mounting arrangement, they can restrict robot motion and provide incomplete posture information. SaddleSense introduces a 3D-printed thermoplastic polyurethane (TPU) saddle-shaped lattice that holds one commercial bend sensor along each curved edge. Because each sensor flexes within its own channel rather than spanning the segment axially, the lattice converts multi-axis body deformation into sensor curvature without tying segment length to sensor length. Each four-sensor module accommodates two-axis bending, contraction, and extension while quantifying all three deformation modes across its four readings. A hybrid calibration maps the sensor readings to piecewise constant curvature (PCC) parameters using a learned model paired with a physics-based fallback for out-of-distribution inputs. We demonstrate a six-module prototype with 24 off-the-shelf bend sensors on a 430~mm continuum body. Using only each module's four local readings, the physics-based model alone achieves a tip position root mean square error (RMSE) of 29.9~mm (7.0\% of body length). The data-driven model reduces the tip RMSE to 13.2~mm (3.1\%) on held-out samples of motions similar to the training set and 15.8~mm (3.7\%) on separately recorded trials. Reducing each module from four sensors to one nearly triples the tip error.

0.32

What the Sleeve Feels: Explainable Machine Learning for Textile Pressure-Based Postural Screening

cs.AI ·2026-10-07 ·Limon Bin Hossain, Md Sadib Rahman Ananta
similarity 0.55
Abstract

Pressure-sensing smart textiles convert body-surface contact into a dense, image-like signal closely tied to posture and movement, making them a promising low-cost route to wearable posture screening. Realizing that promise, however, requires more than classification accuracy: a deployable system must generalize to wearers unseen during training, expose the physical evidence behind its decisions, and tolerate the small donning offsets that occur whenever a garment is removed and re-worn. This paper addresses these three requirements jointly using a knitted piezoresistive sleeve worn on the forearm as a testbed. We regroup fine-grained everyday activities into three coarser screening categories (neutral, potentially undesirable, and functional or transitional), engineer 29 interpretable pressure-distribution features spanning global intensity, spatial center of pressure, quadrant asymmetry, distribution complexity, and short-horizon temporal change, and evaluate under a strict subject-wise split. A tuned XGBoost classifier reaches 0.818 accuracy, 0.788 balanced accuracy, and 0.801 macro F1 on unseen test subjects, with tight frame-level bootstrap 95% intervals of about plus-minus 0.01 and a subject-to-subject standard deviation near 0.06 under leave-one-subject-out cross-validation. A simple 2D-CNN baseline trained on raw frames achieves broadly similar performance, showing that hand-engineered features are not left behind by a learned spatial representation on this task. SHAP-based explanation, a feature-group ablation, per-activity error analysis inside the pooled undesirable class, class-mapping sensitivity, and a simulated donning-rotation stress test together locate what the model relies on, where it degrades, and why, directly targeting the generalization, interpretability, and robustness gaps that determine whether such a system is deployable.

0.25

Synchronized AMG and EMG Dataset of Lower-limb Muscle Activities in Everyday Training

cs.HC ·2026-08-12 ·Dongxu Tang, Shih Ying-Lei, Zhuoyi Ren, Jianting Liao, Yitian Shao
benchmarkdataset similarity 0.55
Abstract

Understanding how lower-limb muscle groups coordinate is important for studying movement impairment, rehabilitation, and physical performance. Reproducible analysis of this coordination requires multimodal recordings that relate local muscle-related signals with body-level kinematics. Complementing neural-level electrical activation captured by EMG, AMG provides a valuable mechanical approach to monitoring muscle activity. Here, we introduce a synchronized, multimodal dataset for healthy-adult lower-limb activities. For data collection on the left leg, 16 triaxial accelerometers were evenly divided into four muscle-site clusters for AMG recording, complemented by four surface EMG channels. A 15-marker optical motion-capture (MoCap) system captured lower-body kinematics, with the resulting marker trajectories used to compute bilateral knee and ankle joint angles. Our dataset contains 1,918 trials from 30 subjects across 16 task conditions. We benchmark the dataset by estimating four joint angles from 300 ms windows of the 5-100 Hz band-pass-filtered AMG data and assess matched EMG features in a separate modality ablation. In the primary cross subject benchmark, the four reference models achieved mean absolute errors of 8.840$^\circ$-9.591$^\circ$. The benchmark and ablation results characterize performance across subjects, tasks, and joint angles and examine the effects of sensor configuration, modality, the number of training subjects, and frequency representation. The release includes documented timing definitions, processed data, and reproducible benchmark resources. https://dongxutang918-afk.github.io/SAME-Limb/

0.16

History-Aware Force Sensing and Tunable Stiffness in a Pneumatic Kresling Origami Cell

cs.RO ·2026-11-01 ·Hengyi Zhou, Jiaqi Wang, Yilin Ma, Dezhong Tong, Xiaonan Huang
similarity 0.55
Abstract

Mechanical hysteresis and pneumatic loading complicate contact force estimation from deformation measurements in soft robots. This work presents a 3D-printed polyether block amide (PEBA) Kresling cell with magnetic angular sensing that supports three operating modes: force sensing at zero gauge pressure, force sensing with tunable stiffness under gauge positive pressure, and self-sensing actuation under negative gauge pressure. A multiscale gated recurrent unit (GRU) network estimates contact force from angular histories to account for the the combined effects of geometric deformation and material response. At zero gauge pressure, the model achieves a test RMSE of 0.76~N. Positive gauge pressure approximately doubles the average axial loading stiffness at +20~kPa over the first 3~mm of compression, while pressure-specific models maintain RMSEs below 0.93~N. Under negative gauge pressure, an energy-based compensation model enables contact force estimation using the the model trained at zero gauge pressure, achieving RMSEs of 1.66--2.10~N under quasi-static conditions. These results demonstrate a compact approach to combining force feedback, tunable axial stiffness, and self-sensing actuation in soft origami systems.

0.36