CS Paper Radar

Evaluation of effective wave velocities in polycrystalline materials using the ultrasonic reflection matrix

Gatien Clément, Alexandre Aubry, Cécile Brütt, Benoît Gérardin, Claire Prada

eess.IV physics.app-ph ·submitted 2026-09-22 12:50 UTC · v1
unusual

Abstract

In-depth characterization of heterogeneous materials has long been a challenge in non-destructive testing. Here, a method is proposed to determine the elastic constants of metallic polycrystalline materials using back-scattered ultrasound. The waves scattered by the microstructure are analyzed to image the effective bulk velocities. To this end, a reflection matrix is acquired with an array of transducers. The projection of this matrix onto a focused basis is used to estimate an average point spread function. Optimizing this function with respect to the propagation model leads to an estimation of the longitudinal velocity. Additional treatments are developed to adapt the method to map the shear wave velocity. The local Poisson's ratio is then deduced from the ratio between those two velocities. Young's modulus and shear modulus can also be obtained assuming known densities. This matrix approach is experimentally validated on different polycrystalline materials. A sample displaying heterogeneous mechanical properties is then simulated to assess the accuracy and the resolution of the method. Its strengths and limitations are discussed, demonstrating its potential for quantitative non-destructive material characterization.

Comment
13 pages, 14 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Ultrasound Elastography: Excitation Methods and Low-Cost Alternative

cs.CV eess.IV ·2026-11-11 ·Corin F. Otesteanu
published similarity 0.52
Abstract

Ultrasound elastography (or elasticity imaging) is a method that characterizes the tissue mechanical properties with the purpose of aiding the diagnosis of certain pathologies. Many novel clinical applications use the assumption that these tissue properties are changed in the presence of pathological processes. Characterization of tissue mechanical properties is achieved by imaging the response of the tissue to an induced stress or excitation. A plethora of approaches have been used in the scientific community to induce excitation in tissue, which usually require additional tools or devices than are costly. Furthermore these are usually integrated in the imaging pipeline using additional software or hardware for control. An alternative that is simpler, faster to integrate (and low-cost) is proposed in this work, by using readily available smartphones as a source of mechanical excitation. The induced displacements are used to solve the elasticity inverse problem (IP) using a finite element method (FEM) approach. Preliminary elasticity reconstructions of a phantom that mimics tissue are similar to when using a dedicated actuator as means of inducing harmonic displacements, illustrating the feasibility of our low-cost ultrasound elasography approach.

0.36

Spatial Thickness Mapping in Heterogeneous Plate Using Wave Physics-Informed Regression

eess.SP ·2026-10-01 ·Amanda Beck, Harsha Vardhan Tetali, Michael MacIsaac, Charlie Tran, Woohyun Eum +2 more
similarity 0.51
Abstract

Traditional guided wave methods for structural health monitoring typically assume uniform material properties, which limit their ability to characterize heterogeneous structures with spatially varying thickness, damage, or material properties. These are challenges commonly encountered in corrosion assessment, composite delamination detection, and structural degradation monitoring. This paper presents a wave physics-informed regression approach that enables spatially resolved characterization of material properties by extracting local dispersion curves across a structure. Our approach focuses on a highly interpretable but flexible physics-informed framework that can be solved using fast algorithms and achieve robust numerical solutions. This paper discusses the mathematical design of the framework, the algorithm, and its interpretation. The framework was applied to a guided wave wavefield imaging dataset from a thin aluminum plate with non-uniform thickness around a hole to validate its practicality. The framework creates an accurate thickness map (correlation coefficient 0.94 with x-ray CT validation) as well as extracts the frequency-dependent velocities of waves within those regions.

0.25

Blind tests of a simple-body model of submarine target strength on open benchmarks

eess.AS cs.SDeess.SP ·2026-11-19 ·Sunil Tyagi
unusual similarity 0.50
Abstract · 17 pages, 6 figures, 9 tables, Data: https://doi.org/10.57967/hf/11704

Finite-element and boundary-element models of a submarine's sonar echo need a mesh and a solver, and their cost grows quickly with frequency. SSR-Sim takes an analytical route. The hull is cut into a few simple bodies, the echo of each is a closed-form result of geometrical acoustics or of the Kirchhoff approximation, the surface enters through a plane-wave reflection coefficient, and the echoes add in energy. This paper describes the method, including the reduction of a hull and its sail to simple bodies, and tests it on three open cases. (1) The reflection coefficient of a 50 mm rubber tile on steel plating, computed with finite elements by Yang et al., is reproduced to 0.02 rms or better at incidence angles from 0° to 75° once the layer is allowed to refract. (2) For the rigid full-scale BeTSSi submarine at 1 kHz, a prediction fixed before the reference was opened agrees with the boundary-element results of Venås and Kvamsdal to within 0.7 dB in every aspect sector from the bow to 150°; in the stern sector it is 5 dB high. (3) For a 1:15 BeTSSi model with 10 mm tiles measured in a lake, a second blind prediction is within -3.1, +1.4 and -0.5 dB of the measured level over aspects 0-120° at 5, 15 and 20 kHz, against -3.1, +3.1 and +3.5 dB for the Kirchhoff-finite-element computation published with the measurement. At 10 kHz, on a resonance of the tile, the prediction is 6.9 dB low, and in the bow sector it is 7 dB or more low at every frequency. The tests cover the specular component and the coating model only. The failures show what such a model lacks: edge diffraction and the returns that set the off-beam floor of a real model.

0.37

Identifying the Shear Piezoelectric Coefficient using Physics-Informed Neural Networks under Exact Boundary and Initial Constraints

cs.LG physics.comp-phcond-mat.mtrl-sciphysics.app-ph ·2026-11-02 ·Suhas Suresh Bharadwaj
similarity 0.49
Abstract · 19 pages, 9 figures

The shear piezoelectric coefficient $e_{15}$ governs the shear-mode electromechanical coupling in piezoelectric micromachined ultrasonic transducers (PMUTs) and surface acoustic wave (SAW) devices, but measuring it typically requires destructive resonance testing on dedicated specimens. On simulated data, $e_{15}$ can instead be recovered non-destructively from sparse, noisy subsurface wavefield observations using a constrained physics-informed neural network (PINN). By building exact spatial distance functions and temporal multipliers directly into the network output, the clamped, grounded boundaries and resting initial state hold automatically, leaving the loss with only the interior equations of coupled electro-elastodynamics and the data misfit. Non-dimensional scaling brings all governing coefficients within one decade of O(1), and the setup removes the boundary and initial-condition penalty weights that soft-constraint methods must tune. In a six-way comparison (plane-strain PZT-5H, manufactured wavefield, 30 dB noise), a soft-penalty baseline with adaptive weights converges to an erroneous $e_{15}$ in four of the five runs (51.7% mean error), and fixed penalties reach an error of 0.85% only after a second-order optimization stage. The constrained formulations reach mean $e_{15}$ errors between 0.15% and 0.51% with held-out displacement errors below 1%. Within these variants, the spatial multiplier gives rapid first-order convergence, and the quadratic temporal multiplier lowers the early-time electrostatic residual by a factor of 6.8 versus a linear one. On finite-element data along one subsurface line, the full formulation recovers $e_{15}$ with 1.19% mean error at 30 dB and keeps it between 0.65% and 2.71% across a 40 to 0 dB noise sweep. Finally, training on displacements alone still recovers $e_{15}$ with mean errors of 0.45% on finite-element and 1.64% on manufactured data.

0.27

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.48
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35

Closed-form weak-wave propagation pressure amplitudes for arbitrary power-law attenuation

eess.SP physics.med-ph ·2026-09-16 ·Esteban Avilés, Michael Oelze, Roberto Lavarello, Andres Coila
publishedunusual similarity 0.48
Abstract · 7 pages, 2 figures, submitted to JASA Express Letters

Biological tissues exhibit power-law frequency dependence of the attenuation coefficient. We derive closed-form weak-wave expressions for fundamental, second-, and third-harmonic pressure amplitudes of monochromatic acoustic plane waves in homogeneous media with arbitrary power-law attenuation to extend classical expressions for quadratic attenuation. For linear frequency dependence of attenuation, one-dimensional simulations using the k-Wave k-space pseudospectral solver yielded 35-42% (classical) and 0-2% (proposed) normalized root-mean-square errors for fundamental-band depletion. This extension supports improved fundamental-band B/A estimation for quantitative ultrasound tissue characterization. A proof-of-concept through-transmission application in phantoms with nearly linear attenuation yielded experimental B/A estimation errors of 23.7-52.7% (classical) and 4.0-5.9% (proposed).

0.41

Pulse-Echo Ultrasound Methods for Speed-of-Sound Estimation: A Review

eess.IV physics.med-ph ·2026-08-23 ·Can Deniz Bezek, Orcun Goksel
survey similarity 0.48
Abstract

Speed of sound (SoS) is fundamental to ultrasound beamforming and a promising quantitative biomarker for tissue characterization. Although transmission- and reflector-based methods have demonstrated the diagnostic value of SoS, their need for dedicated hardware or constrained acquisition geometries limits clinical usability. Pulse-echo SoS imaging addresses these limitations by estimating SoS with conventional ultrasound probes and data acquisition paradigms. This review provides a structured overview of pulse-echo SoS estimation methods, categorized by the source of information used, the estimated SoS representation, and the reconstruction strategy. We review methods by their locality, e.g., global, layer-wise, and spatially-resolved predictions, as well as in terms of prediction strategies including gradient-free search, optimization-based solutions, analytical closed-form approximations, and deep learning-based methods. Finally, we summarize emerging diagnostic applications in the breast, liver, and muscle, while discussing challenges and possibilities with SoS imaging.

0.28

UltraDiff: Differentiable Ray Tracing in Ultrasound for Shape Optimization

cs.GR cs.CV ·2026-10-06 ·Felix Duelmer, Magdalena Wysocki, Nassir Navab, Mohammad Farid Azampour
top venuehot direction similarity 0.44
Abstract · 4 pages, 4 figures, 1 table. Accepted at SIGGRAPH Asia 2026 Technical Communications

Physically-based differentiable rendering enables gradient-based optimization of scene parameters by matching rendered images to measurements, but has so far mainly focused on light transport. We extend this paradigm to medical ultrasound, where image formation resembles transient rendering: echoes are binned by time-of-flight rather than projected onto an image plane. We present UltraDiff, a modular framework for differentiable ultrasound ray tracing. UltraDiff formulates ultrasound image formation as a path-space integral, gated by travel time between the transducer and tissue interfaces, and derives a Monte Carlo estimator of both the forward model and its gradients with respect to scene parameters. We demonstrate this on an inverse geometry estimation: starting from a sphere, an SDF is optimized until simulated echoes match measured ones, recovering vertebral surfaces from simulated B-mode sweeps and from a real robotic acquisition of a spine phantom. Unlike state-of-the-art ultrasound shape reconstruction methods, which rely on pre-segmented images, our approach operates unsupervised on B-mode images through analysis-by-synthesis, while achieving competitive geometric accuracy. Implemented on top of Mitsuba 3, UltraDiff brings differentiable path tracing to a new sensing modality and provides a foundation for inverse problems in acoustic imaging.

0.47