CS Paper Radar

Mobility Enhancement of Patients Body Monitoring based on WBAN with Multipath Routing

Yasna Ghanbari Birgani, Nastooh Taheri Javan, Mohsen Tourani

cs.NI ·submitted 2026-10-02 09:24 UTC · v1
publishedunusualhighly cited

Abstract

One of the promising applications of wireless sensor networks (WSNs) is monitoring of the human body for health concerns. For this purpose, a large number of small sensors are implanted in the human body. These sensors altogether provide a network of wireless sensors (WBANs) and monitor the vital signs and signals of the human body; these sensors will then send this information to the doctor. The most important application of the WBAN is the implementation of the monitoring network for patient safety in the hospital environment. In this case, supporting patients' mobility is one of the basic needs, which has been underestimated in recent studies. The problem that involves providing the required energy for the units used in this type of network is challenging; for this reason, sent/received units with very low power consumption and with a very small radius are used in order to save energy. The resulting small sending range leads to the lack of support for patients' mobility. In this paper, the ad hoc mode is suggested for use to establish a network and a multipath routing algorithm for the purpose of supporting patients' mobility in a hospital setting. The results of the simulation show that, in addition to supporting patients' mobility, the use of the proposed idea instead of previously presented protocols reduces delays in data transmission and energy consumption; it also increases the delivery rate depending on the destination and the lifetime of the network, while increasing routing overhead.

Closest papers

Nearest neighbours by meaning across the whole index.

SmartBike: A Low-Power Edge IoT System for Cycling Safety and Real-Time Awareness

eess.SP ·2026-10-08 ·Sogand Hashemi, Gonçalo Sarabanda Neves Loureiro, Catarina Pereira De Freitas Lima, Lyssa Ramaut, Liesbet Van der Perre
published similarity 0.50
Abstract · 5 pages, 4 figures, 4 tables. Presented at the 46th Symposium on Information Theory and Signal Processing in the Benelux (SITB 2026), Ghent,…

Urban cycling is a sustainable mode of transportation, but cyclists remain highly vulnerable in dense traffic because of limited situational awareness and the lack of active safety assistance on conventional bicycles. This paper presents SmartBike, a low power Internet-of-Things (IoT) platform for cyclist safety, combining blind spot monitoring, rider usage detection, localization, and wireless edge-to-gateway communication. The proposed system consists of a bike-mounted IoT node and a gateway assisted monitoring interface. The node integrates three time-of-flight sensors for blind spot detection, an IMU module for motion sensing and on-board speed estimation, a GNSS module for localization, and a saddle mounted piezo-electric transducer for event-driven wake up. To satisfy the energy constraints of the IoT node, the design employs piezo-triggered activation, application specific sensing rates, and compact connectionless Bluetooth Low Energy (BLE) advertisements for low overhead transmission. The firmware is implemented in Zephyr RTOS using a lightweight state machine architecture, while the gateway performs passive BLE scanning, payload decoding, and real-time dashboard visualization. The BLE payload is reduced to 11 bytes, and power analysis shows that sensing accounts for more than 90% of the total energy budget, while wireless communication represents less overall consumption. With a 12600 mWh battery, the estimated lifetime reaches approximately 21 months under typical commuting conditions (Average 40 min per day).

0.40

A Wearable Sensor Array on Conductive Textiles for Body Surface Temperature Mapping

eess.SP ·2026-10-27 ·Amiri Onuki, Akihito Noda
published similarity 0.50
Abstract · 6 pages, 6 figures. Accepted manuscript of a paper published in Proceedings of the SICE Festival 2026 with Annual Conference, September 14-1…

Continuous monitoring of body-surface temperature distributions can provide useful information for wearable health and thermal-condition monitoring. However, practical daily-use wearable systems for distributed temperature sensing remain difficult to implement because multiple sensor nodes require power delivery and data collection across a garment. Conventional wiring increases system complexity, reduces placement flexibility, and can compromise the wearability of garment-integrated sensor arrays. To address this issue, we present a conductive-textile-based wearable temperature sensing system in which the textile itself serves as a shared bus for both DC power delivery and data communication. Each sensor node is implemented as a compact, battery-free circular board with a diameter of 21 mm and a weight of 0.9 g, integrating a commercial temperature sensor and custom circuitry for UART/DC superposition. The shared textile bus enables flexible node placement without individual wiring while supplying power to each node. Address-based half-duplex UART with master polling enables collision-free multi-node communication. To demonstrate the system-level capability, we implemented an 18-node sensor array on a garment worn by a mannequin and developed a real-time temperature mapping viewer. In a thermal scanning demonstration using warm air from a heat gun with a set temperature of approximately 50 °C, the 18-node array captured spatiotemporal temperature variations over the garment surface at a refresh rate of 99.2 Hz. These results show that the proposed conductive-textile bus can support real-time, high-refresh-rate distributed temperature mapping, providing a practical basis for garment-integrated body-surface monitoring and future multi-sensor wearable systems.

0.41

Protocol-Flexible Custom NFC for Wire-Free Wearable Sensor Networks

cs.NI ·2026-09-20 ·Riku Maeda, Akihito Noda
publishedunusual similarity 0.50
Abstract · 4 pages, 5 figures, 1 table. Accepted manuscript; accepted for publication in IEEE Sensors Letters

This study presents a custom near-field communication (NFC) system with software-defined protocol implementation for wearable sensors distributed across the body. Conventional wired implementations can degrade wearability because of mechanical constraints, whereas radio-based wireless approaches such as Bluetooth are affected by body-induced signal attenuation and limited communication coverage. The proposed system is compatible with previously demonstrated fabric-integrated meander coils, which provides a feasible path toward garment-scale NFC communication areas. The system combines a microcontroller unit with compact modulation and demodulation circuits, allowing medium access control and other communication protocols to be implemented in software. Experimental results demonstrate continuous acquisition of three-axis acceleration data from three sensor tags, achieving a per-tag polling rate of $222\,\mathrm{Hz}$ and an effective throughput of approximately $16\,\mathrm{kbps}$, delivering $156$ valid samples per second per tag at a measured packet error rate of $30\%$.

0.64

An Energy Efficient Wearable for Monitoring Elderly People Health

eess.SP cs.CY ·2026-08-26 ·M. Much, A Moraes Filho, J. Sieg, F. Hessel, A. Cataldo Neto +1 more
similarity 0.49
Abstract · 8 pages, 11 figures

The aged population is exposed to risk situations, like falls, sudden changes in vital signs, and faints. These situations become common at this life stage due to a decrease in body capacity and illnesses increase. This scenario imposes attention on families and the national health system. Some studies propose to overcome this problem through elderly health monitoring systems based on smartphones, smartwatches, and other equipment that usually cover low-efficient communication systems and low battery life. This paper proposes an efficient health monitoring system based on Sigfox IoT service and a watch-type wearable device for sensing elderly motion, location, and vital signs to predict risk situations designed to achieve at least 30-days of battery life. Our experimental results show that this architecture is a low-cost, low-power, efficient, and feasible elderly health monitoring solution.

0.36

Location-Based Safety Management with Wearable Seamless Indoor-Outdoor Positioning

cs.RO ·2026-10-15 ·Anh-Van Vu, Seungwoo Chae, Changmin Sung, Van-Tuan Nguyen, Dongsoo Han
published similarity 0.48
Abstract · 6 pages

Reliable worker localization is essential for real-time industrial safety management, but seamless outdoor-indoor positioning remains challenging. GNSS performs well outdoors yet degrades near buildings and fails indoors, while many indoor systems require costly infrastructure or extensive calibration. This paper presents a practical safety-oriented positioning system that uses resource-constrained wearable tags and a device-cloud split architecture for continuous outdoor-indoor worker tracking. The tag integrates GNSS, IMU, barometric sensing, LTE Cat-M communication, and performs lightweight sensor fusion, while the cloud server executes map-aware fusion for continuous tracking. Developed as an operational platform, the system also includes a database, a map tool, and a dashboard that provide real-time monitoring, geofencing-based access alerts, and safety and productivity analysis. Experiments with multiple participants, each walking an approximately 1400 m outdoor-indoor route, using LTE Cat-M communication, achieve mean errors of 1.32 m indoors and 3.30 m outdoors, while maintaining low positioning latency and efficient power consumption. These results demonstrate the feasibility of wearable-based seamless positioning for scalable real-time safety management.

0.40

Demo: Matter-Based IoMT Telemetry and Security Analysis

cs.AR cs.ETcs.RO ·2026-11-12 ·Muhammad Hassan, Masooda Bashir, Carl Gunter
similarity 0.47
Abstract

Connected health devices increasingly support health monitoring outside clinical settings, making secure and accessible physiological data important for patients and caregivers. However, device-specific applications and interfaces complicate the integration of readings from different devices. The Matter standard provides standardized device commissioning and protected communication, but its cluster library does not represent the health attribute measurement. We present a preliminary demo study of a Matter-based IoMT testbed with a specific HealthVitals cluster. Implemented in the connectedhomeip SDK on a Raspberry~Pi~5, the cluster exposes simulated heart rate, blood oxygen saturation, and body temperature. We examine commissioning, attribute retrieval, communication under simulated packet loss, and operational traffic through a reference controller. The study demonstrates that this custom telemetry model can operate within the tested Matter configuration without modifying commissioning or secure-session mechanisms. The resulting testbed gives researchers and device developers a concrete platform for investigating health-oriented extensions. It also supports exploration of local telemetry integration that could help patients and caregivers access readings across connected devices.

0.26

IZM-DSR: A New Zone-Disjoint Multi-path Routing Algorithm for Mobile Ad-Hoc Network

cs.NI ·2026-11-15 ·Nastooh Taheri Javan
publishedhighly cited similarity 0.45
Abstract

Some of multi-path routing algorithms in MANETs use multiple paths simultaneously. These algorithms can attempt to find node-disjoint to achieve higher fault tolerance. By using node-disjoint paths, it is expected that the end-to-end delay in each case should be independent of each other. However, because of natural properties and medium access mechanisms in ad hoc networks, such as CSMA/CA, the endto-end delay between any source and destination depends on the pattern of communication in the neighborhood region. In this case some of the intermediate nodes should be silent to reverence their neighbors and this matter increases the end-toend delay. To avoid this problem, multi-path routing algorithms can use zone-disjoint paths instead of node-disjoint paths. In this paper we propose a new multi-path routing algorithm that selects zone-disjoint paths, using omnidirectional antenna. We evaluate our algorithm in several different scenarios. The simulation results show that our approach is very effective in decreasing routing overhead and end-to-end delay.

0.46

Wearable Data Profiling for NDN-Based Smart Healthcare: Performance Comparison with an IP Baseline

cs.NI ·2026-10-14 ·Mohammad R. Shakournia, Nasser Yazdani, Carlos T. Calafate
similarity 0.45
Abstract

Smart healthcare IoT requires low-latency and reliable delivery of patient data, yet IP-based communication remains host-centric and offers limited support for mobility, caching, and request aggregation. This paper evaluates a smartphone-centric Named Data Networking (NDN) approach in which a patient's smartphone aggregates sensor streams and publishes a stable latest profile under a consistent name, enabling effective in-network caching. Using ndnSIM simulations on a realistic medical IoT topology, we compare NDN and IP under identical traffic and link conditions. Results show that per-sample naming provides little benefit, but smartphone aggregation with stable naming allows NDN caching to reduce delay after cache warm-up and achieve significantly higher delivery ratios under congestion compared to IP.

0.35