CS Paper Radar

ElectroCalm: Investigating User Experience and Physiological Responses to Multi-Node Transcutaneous Electrical Stimulation for Stress Modulation

Yoon Kyung Shon, Pablo E. Paredes

cs.HC ·submitted 2026-10-15 23:35 UTC · v2
published

Abstract

Transcutaneous Electrical Stimulation (TES) for stress modulation has largely focused on vagus nerve stimulation at the neck, yet two questions remain underexplored: how users experience electrotactile sensations at this sensitive site, and whether electrotactile feedback itself can function as a haptic stress intervention. To investigate this gap, we applied an 8-node TES array to two body sites during a cognitively demanding 2-back task: the neck, a site used in prior vagal TES research for its anatomical proximity to the cervical vagus nerve, and the arm, the most common haptic wearable site, which primarily provides cutaneous electrotactile sensation without vagal access. In a usability study, both sites were rated as comparably comfortable without disrupting task performance, though the same stimulation was interpreted differently across sites. A second study assessing the physiological effects of active versus inactive stimulation under identical electrode attachment revealed that only neck TES produced cortical and autonomic changes consistent with stress modulation, while arm TES did not differ from inactive conditions. These findings suggest that neck TES can be acceptable despite the site's sensitivity, and that both the physiological effects and the sensory experience of TES depend on placement.

Comment
25 pages, 6 figures, to appear in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies, Vol. 10, No. 4, December 2026
DOI
10.1145/3857961

Closest papers

Nearest neighbours by meaning across the whole index.

Bio-Inspired Electrotactile Feedback: A Framework and Impacts of Multimodal Cues

cs.HC cs.ET ·2026-10-13 ·Melika Emami, Amirhossein Bayat, Rahim Tafazolli, Atta Quddus
similarity 0.62
Abstract

Electrotactile stimulation, as a haptic feedback method, often struggles to evoke high-quality natural sensations. Consequently, despite its practical advantages, it is generally less preferred in human-machine systems than mechanical approaches. In this paper, we propose a bio-inspired stimulation framework that generates signals modelled on afferent neural activity derived from a touch model. By producing more biologically plausible spiking patterns, the proposed approach aims to enhance the realism of perceived tactile sensations. To evaluate these stimulation patterns in a realistic task context and to quantify the influence of visual and movement cues, we conducted a series of subjective experiments under three conditions. The results indicate that bio-inspired modulation was effective: in particular, bio-inspired co-modulation of amplitude and frequency achieved a favourable pressure-irritation trade-off, increasing the probability of perceiving pressure while maintaining low irritation (pressure: 0.78; irritation: 0.24) relative to the other patterns. Visual cues and hand movement further improved feedback quality by significantly increasing the probability of reporting pressure (p$<$0.001) without a corresponding increase in irritation, and by increasing mean naturalness ratings. Overall, these findings demonstrate the potential of bio-inspired electrotactile patterns to improve haptic feedback quality, and highlight the importance of evaluating such methods under realistic, multimodal interaction scenarios.

0.29

AppetiteCheck: Feasibility of Momentary Vagus Nerve Stimulation as an Implicit Intervention for Eating Behavior

cs.HC cs.ET ·2026-09-09 ·Tan Gemicioglu, Jas Brooks, Pedro Lopes, Tanzeem Choudhury
published similarity 0.59
Abstract · 28 pages, 9 figures. Published in Proceedings of the ACM on Interactive, Mobile, Wearable and Ubiquitous Technologies, Volume 10, Issue 3, 2…

Overeating and emotional eating are common health issues that affect people even without an eating disorder. The vagus nerve plays a critical role in the gut-brain axis, and implanted vagus nerve stimulators have been associated with reduced appetite. In this paper, we propose transcutaneous cervical vagus nerve stimulation (tcVNS) as a ubiquitous system to provide immediate, low-effort intervention during an eating episode. In a study with 24 participants, we evaluated a mobile, handheld tcVNS device during a single episode of distracted snacking. We found that participants ate 9.6% less and 23.6% more slowly during vagus nerve stimulation than during sham stimulation. Post-snacking satiety was the same in both conditions, while heart rate was lower during vagus nerve stimulation. The stimulation was described as subtle and barely noticeable. Overall, these results provide evidence for the feasibility of non-invasive vagus nerve stimulation as a low-attention intervention for managing eating behavior -- one that can be packaged inside ubiquitous interactive systems. As such, we extend the design space of implicit interfaces toward physiological intervention, motivating future ubiquitous systems that pair eating-related sensing with low-attention interventions.

0.65

A Portable Multichannel Kilohertz Current Stimulator for Selective Peripheral Transcutaneous Stimulation

eess.SP ·2026-09-19 ·Jiatong Jiang, Andrea Bottin, Simos Koutsoftidis, Enrico Merlo, Georgios Gryparis +4 more
unusual similarity 0.55
Abstract · 12 pages, 10 figures, to be submitted to journal

We present SineStim, a portable, 12-channel current stimulator for transcutaneous spinal cord stimulation and peripheral electrical stimulation at kilohertz frequencies. Each channel delivers independent, current-controlled sinusoidal waveforms with amplitudes from 0 to 50 mA (0.1 mA resolution) and frequencies from 0 to 50 kHz (0.1 Hz resolution), with burst modulation modes supported. A custom output stage with a high compliance voltage of $\pm$ 120 V was designed and developed, with galvanically isolated channels and independently programmable stimulation parameters for each channel. The stimulator performance was tested on both passive loads and human subjects. Benchtop characterisation on resistive and resistive-capacitive loads demonstrated a total harmonic distortion between 1 - 8 % across typical operating conditions. Multichannel functionality was demonstrated in two-channel human forearm stimulation experiments. Burst-modulated waveforms with differing channel amplitudes modulated inter-finger force ratios, and channels with small frequency offsets elicited temporal interference force patterns at the beat frequency. Smoothly enveloped bursts of kilohertz sinusoidal waveforms produced negligible stimulation artifacts at steady state in concurrent surface electromyography (sEMG) recordings at motor threshold, in contrast to conventional biphasic square wave stimulation. SineStim delivers precise, isolated, multichannel kilohertz stimulation through a portable device, with performance demonstrated on both benchtop loads and human participants. By combining multichannel spatial control with minimal-artifact sEMG compatibility, SineStim enables future precision non-invasive neural stimulation paradigms based on multichannel optimisation and real-time closed-loop control capabilities not available via existing single-channel stimulators.

0.28

Remote Surfaces at Your Fingertips: Electrovibration-Based Tactile Feedback for Robot Teleoperation via Touchscreen Interfaces

cs.RO cs.HC ·2026-08-22 ·Alperen Kenan, Juan José García Cárdenas, Adriana Tapus, Paul Bremner, Manuel Giuliani
published similarity 0.54
Abstract · 8 pages, 10 figures, accepted for presentation at the 2026 IEEE Conference on Telepresence in Bristol, United Kingdom, November 9-13, 2026

Enabling operators to perceive and interact with remote environments naturally is a fundamental challenge in robotic teleoperation. This is especially critical in tasks involving physical interaction, where real-time haptic awareness improves operational safety and effectiveness. Existing kinesthetic haptic feedback methods suffer from instability during rigid surface contacts and remain sensitive to communication delays, while visual cue-based force feedback imposes additional cognitive load and limits sustained situational awareness. This work presents a teleoperation interface that conveys remote surface interactions to the operator through electrovibration-based tactile feedback, enabling naturally mapped force reflection while avoiding the stability issues associated with kinesthetic feedback and the latency limitations of mechanical actuators. A user study (N=21) evaluated interface usability, sense of presence, and operator workload under two force reflection conditions: visual feedback and electrovibration-based tactile feedback. Characterisation experiments further assessed path-following accuracy and response time across both conditions. Results show that tactile feedback significantly reduced response time by 15.35% (p=0.002, d=0.96) and increased the sense of presence by 31% (p<0.001, d=0.90) compared to visual feedback, while imposing comparable workload and usability across both conditions. These findings demonstrate that electrovibration-based tactile feedback is a viable and effective modality for robot teleoperation, improving operator responsiveness and sense of presence in contact-rich manipulation tasks, with direct applicability to safety-critical domains such as nuclear maintenance.

0.20

A wearable input/output interface learns personalized models of haptic perception

cs.RO ·2026-11-06 ·Wen Li, E. Magnus Adams, Zijie Xu, Jiawen Yao, Aybala Esmer +3 more
hot direction similarity 0.53
Abstract

Wearable haptic interfaces deliver physical stimuli to the skin, yet perceived locations vary widely across users and diverge from actuator locations, particularly for emergent tactile-feedback techniques. We developed a wearable haptic input/output (I/O) device integrating a 36-channel electrotactile array with capacitive touch sensing, enabling stimulation and user-reported percept locations to be registered within the same body-referenced coordinate frame. In 24 participants, the device revealed electrotactile and referred-thermal perceptual maps with notable interparticipant variability. Despite this variability, both modalities retained electrode-pair-specific spatial structure across participants. Tactile and thermal percepts also showed spatial correspondence, whose strength varied across participants. These findings motivated our human-in-the-loop calibration framework, which adapts a forward-prediction strategy to individual users and generates personalized perceptual models. These models enabled inverse rendering by selecting stimulation patterns predicted to generate a target percept for a specific user. Using these models, we demonstrate personalized haptic rendering in haptic-guided robot teleoperation, visual-to-haptic sensory substitution, interpersonal haptic communication, and virtual reality (VR). Together, this platform provides a route toward adaptive haptic interfaces that measure, model, and render according to each user's perception.

0.31

A Co-Located MMG-FES Wearable Interface for Action-Updated State-Gated Stimulation

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.52
Abstract · 9 pages, 8 figures. Submitted to IEEE Robotics and Automation Letters

Functional electrical stimulation (FES) assists movement, but fixed schedules cannot track how a repeatedly activated muscle changes, and surface electromyography (EMG) near the stimulation electrodes is often obscured by artifacts. Prior work recorded mechanomyography (MMG) passively during closed-loop FES cycling and estimated FES-induced fatigue or predicted fatigue for FES control, without gating stimulation with stimulated-site MMG. In this study, we present VG-FES, a wearable module co-locating microphone-based MMG, programmable charge-balanced biphasic stimulation, and embedded state-gated control at one on-skin thigh site. After each action, we compare rectus femoris (RF) mean power frequency (MPF) with an early-session baseline of the same direction, giving a relative state. A threshold on its window means enables fixed-duration bursts separated by rest periods. During onboard stimulation, MMG remained recordable, whereas near-site EMG was artifact-dominated. Under prolonged external stimulation, cycle-wise MMG tracked an independent local-pressure reference (Spearman rho = 0.968). In leave-one-session-out evaluation on 2284 squat actions (11 sessions, eight participants), MMG-based action segmentation reached an event-detection F1 of 0.923 and direction classification a balanced accuracy of 0.925. Online, over 15.69 min of self-paced squats, one participant received four bursts while MMG acquisition and action monitoring continued. Mechanical feedback from the stimulated site offers wearable FES and assistive robotics a per-action basis for state-gated stimulation.

0.40

Tactile Search: Enhancing Targeting in 3D Space

cs.HC ·2026-09-05 ·Amber Maimon, Iddo Yehoshua Wald, Jonas Keppel, Eunhee Chang, Yoshifumi Kitamura +3 more
top venue similarity 0.52
Abstract · Accepted to the 2026 IEEE International Symposium on Mixed and Augmented Reality (ISMAR 2026)

Visual search is crucial in daily life, from scanning for relevant information to spotting signs of danger. When sensory channels are overloaded or degraded, cognitive tasks can be supported by crossmodal information representations through vibrotactile cues. We introduce Tactile Search, an approach that uses modulation of frequency and amplitude of vibrations to the hands, for guiding attention to the location of objects in 3D space. We evaluated this approach in a competitive VR game where participants searched for targets using both vision and touch. Across two studies -- an in-the-wild demonstration (n=55) and a controlled laboratory experiment (n=28) -- we found that vibrotactile feedback significantly improved performance and increased user confidence. In the combined haptic condition, performance did not differ across target heights. We further analyzed participants' subjective experiences and search strategies highlighting the benefits of the tactile cues. Our findings suggest that Tactile Search can enhance interaction and provide design considerations for integrating haptic search into interactive systems.

0.24

A dynamic backrest may help accommodate trunk movement, and multi-device work elicits more of it: An exploratory comparison of high-end office chairs under single- and multi-device tasks

cs.HC ·2026-11-02 ·Yejin Kang, Dusan Baek, Dongwoo Park, Kitae Hwang, Woojin Park
similarity 0.52
Abstract · 22 pages, 4 figures

Dynamic-sitting office chairs are usually compared with static sitting rather than with each other, and the contribution of backrest deformability (lateral backrest movement) is unknown. Office work also increasingly spans multiple devices. Twenty healthy adults (10 men, 10 women) completed a 15-minute single-device and a 15-minute multi-device proofreading task on each of three chairs: two commercial dynamic-sitting chairs (T90, Aeron) and a T90 whose backrest lateral movement was mechanically fixed (T90-fixed). We recorded subjective ratings, head and trunk posture (inertial measurement units), upper trapezius and lateral gastrocnemius activity (electromyography), and task performance. Chair effects were largely null: T90 and Aeron did not differ in ratings or performance, posture and muscle activity showed only isolated, direction-inconsistent differences, and preferences were polarized. The standard T90 showed greater trunk movement (mean absolute angular velocity in yaw) than T90-fixed during the multi-device task (p = 0.042), which may indicate that its movable backrest helps accommodate trunk movement under demanding work; no other whole-sample posture, muscle, rating or performance measure differed between these two configurations, and replication is needed. Task effects were large and consistent: the multi-device task elicited greater and faster head, trunk and shoulder movement and higher upper trapezius activity than the single-device task, with lower reading throughput. Multi-device work thus imposes substantially greater movement demands than single-device work, which supports designing chairs that accommodate movement in modern work environments.

0.42