CS Paper Radar

A Dry-Contact Ear-EEG System With Continuous Electrode-Skin Impedance Mismatch Monitoring for Motion Artifact Cancellation Using DRL Stimulus

Lohan Atapattu, Sajitha Madugalle, Imasha Nethmal, Erandee Jayathilaka, Avishka Herath, Kithmin Wickremasinghe, Simon L. Kappel, Nilan Udayanga, Chamira U. S. Edussooriya

eess.SP eess.SY ·submitted 2026-09-02 16:12 UTC · v1
published

Abstract

Dry-contact ear-electroencephalography (Ear-EEG) enables wearable neural monitoring. However, motion induced electrode-skin impedance (ESI) mismatches between electrodes can severely degrade signal quality. To the best of our knowledge, this paper presents the first proof-of-concept dry-contact EarEEG system that uses a driven-right-leg (DRL) stimulus for continuous ESI mismatch monitoring, enabling online adaptive motion artifact cancellation. A 1 kHz sinusoidal stimulus is injected through the DRL electrode. The resulting response to the injected carrier is separated from the EEG using bandpass filtering and demodulation, and then used to extract the ESI mismatch information as the reference input for a normalized least-mean-square adaptive filter followed by a Hampel filtering stage. To evaluate artifact suppression and preservation of neural activity, alpha-band EEG activity was analyzed involving four healthy participants performing head nodding, electrode tapping, and jaw clenching. The system achieved artifact power reductions of 6.5, 12.6, and 9.0 dB (77.6%, 92.8%, and 86.4%, respectively) while alpha-band modulation remained clearly observable after processing. This demonstrates the feasibility of DRL-stimulusbased ESI mismatch monitoring for motion artifact cancellation in wearable dry-contact Ear-EEG.

Comment
5 pages, 4 figures, accepted for presentation at IEEE BioCAS 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Artifact removal improves electrodermal waveforms but not downstream classification in a virtual-reality balance task

cs.HC cs.LGeess.SP ·2026-10-05 ·Haochen Chai, Qixu Zhu, Siyao Li, Fangfang Jiang
benchmarkcode/data similarity 0.60
Abstract · 10 pages, 9 figures, 3 tables. Code and frozen data: https://github.com/rtb-1005/FairEDA

Artifact removal routinely precedes the classification of electrodermal activity (EDA), on the assumption that a cleaner signal supports a better decision. We tested this assumption in a virtual-reality (VR) balance-disturbance task. A residual gating network was trained on a benchmark with expert-corrected EDA, frozen, and applied to VR recordings, where raw and gated signals were classified by five published time-series methods under identical leave-one-participant-out evaluation. On the benchmark the gate detected artifacts well (median record AUROC 0.94) and reduced error inside artifact regions by 17.8%. In the VR task it did not improve classification. Changes in balanced accuracy ranged from -1.35 to +0.93 percentage points, no classifier improved and two lost accuracy, and all five were equivalent to raw input within +/- 3.32 points. The benefit was lost between waveform and decision. The correction that lowered waveform error also reduced skin conductance response detection in all 43 benchmark records. Processing left 92.8% of predictions unchanged, and the predictions it did change were corrected and corrupted at similar rates. The VR recordings also carried little contamination (an estimated 4.6% of samples), and even perfect localization of deliberately injected artifacts recovered only 3.3 points in the most sensitive classifier. A pooled association between artifact level and accuracy (11.3 points) disappeared within participants (0.1 points), showing how differences between people can make cleaning look useful. Preprocessing should be judged by the decision it supports, against an unprocessed arm.

0.40

ErgoAssist: Cognition-Aware Posture Feedback in Wearable Ergonomic Systems

cs.HC ·2026-08-31 ·Sarmistha Sarna Gomasta, Bhawana Chhaglani, VP Nguyen, Prashant Shenoy
similarity 0.58
Abstract

Prolonged digital device use has made poor posture and musculoskeletal discomfort pervasive among knowl- edge workers. Existing ergonomic wearables rely solely on posture thresholds, frequently interrupting users during high-focus moments and leading to alert fatigue and abandonment. Yet posture and cognitive load are closely coupled, and most systems remain cognitively unaware. We present ErgoAssist, a head-worn ergonomic assistant that detects poor posture using IMU-based head tracking and estimates task-induced cognitive load using a consumer-grade EEG headband for continuous everyday use. In a controlled lab study, ErgoAssist achieves 81% posture classification and 90.2% task induced cognitive load estimation accuracy under leave-one-subject-out evaluation. In a preliminary real-time deployment, cognition-aware alerting reduces alert frequency by 81%, improves perceived usability by 43%, task performance by 25%, and improves posture correction rate by 38%, delivering fewer but better-timed interventions rather than merely suppressing alerts.

0.37

Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach

cs.HC ·2026-09-21 ·Philipp Lepold, Paula Breitling, Jonas Hummel, Tobias Röddiger, Michael Beigl
published similarity 0.56
Abstract

Ear-ECG enables unobtrusive cardiac monitoring, but existing approaches often struggle with low signal amplitudes and limited morphology preservation. We evaluate a finger-to-ear ECG paradigm that combines an in-ear electrode with a rear housing finger-contact electrode in a speaker-equipped earbud. A study with 30 participants investigated four finger-to-ear electrode geometries against chest-reference ECG and additionally assessed robustness under music playback, talking, and walking disturbances. Left-finger configurations achieved R peak detection F1-scores >99% with high agreement of key ECG morphology features. In contrast, right finger configurations as well as walking led to severe signal degradation. The results reveal a trade-off: while cross-body setups provided the highest signal fidelity, users preferred same-side contacts for comfort reasons. This establishes finger-to-ear ECG as a robust, morphology-aware paradigm for opportunistic sensing in earables.

0.38

EITWatch: Smartwatch-Integrated Planar Electrical Impedance Tomography for Hand Gesture Recognition

cs.HC ·2026-08-29 ·Xuanyou Liu, Novel Alam, Karan Ahuja
top venuecode/data similarity 0.56
Abstract · 7 pages, 6 figures, 2 tables. Accepted to UIST '26. Code: https://github.com/XuanyouLiu/EITWatch_Hardware

Wrist Electrical Impedance Tomography (EIT) senses hand gestures from muscle- and tendon-driven impedance changes, but prior wrist-EIT systems require electrode coverage beyond the watch-back contact patch and separate analog front ends. We present EITWatch, the first wrist-EIT system built around smartwatch case-back geometry, asking whether this contact patch alone can support gesture recognition: eight planar electrodes in a 31 mm ring acquire 35 impedance measurements at 48 Hz. Because a planar array cannot encircle the wrist, EITWatch uses multi-depth scanning to sample multiple source-sink distances and current paths; it beat matched adjacent injection by 15.1/10.4 percentage points (macro/micro) across all 12 participants. In a prompted study, within-session leave-one-round-out accuracy reached 91.4%/92.5% (window/trial) for six macro-gestures, and 90.1%/91.5% (window/segment) for five micro-gestures plus relax; window-level cross-session and leave-one-user-out transfer reached 73.2%/70.4% and 63.1%/55.3% (macro/micro).

0.58

Beyond Reconstruction: A Unified Framework for Trustworthy and Explainable EEG Artifact Removal Evaluation

eess.SP cs.AI ·2026-11-16 ·Phat Lam, Hung Nguyen, Lam Pham, Huy Phan, Dat Tran +3 more
similarity 0.56
Abstract · IEEE journal manuscript under review

Deep-learning methods have achieved strong performance in EEG artifact removal, but evaluation remains dominated by reconstruction metrics such as error, correlation, and signal-to-noise ratio. Although these metrics assess similarity to clean EEG, they do not establish whether models effectively suppress artifacts, preserve neural activity, or provide reliable explanations. To address these limitations, we propose TriX-EEG, a three-level framework for trustworthy and explainable EEG artifact removal. Level 1, Signal Validity (SV), evaluates reconstruction quality and neural band-power preservation. Level 2, Removal Faithfulness (RF), assesses the removed component through artifact error and residual artifact/neural leakage. Level 3, Explanation Reliability (ER), examines model behavior through temporal alignment, causal relevance, and stability. We evaluate TriX-EEG using nine published neural denoisers across three public benchmarks derived from EEGDenoiseNet and the PhysioNet Motion Artifact Contaminated EEG Dataset, covering EOG, EMG, and motion artifacts. Results show that reconstruction metrics alone are insufficient for trustworthy denoiser assessment: RF complements it by revealing whether errors stem from residual artifact or suppressed neural activity, while ER captures distinct aspects of explanation behavior, supporting joint evaluation of three aspects within a unified framework rather than reliance on any single factor. External validation on an independent EEG/EOG dataset and the BCI Competition IV-2a motor-imagery dataset further demonstrates broadly consistent rankings under dataset shift. Higher-ranked denoisers generally preserve more task-relevant information or cause less downstream performance degradation. Overall, TriX-EEG provides a comprehensive basis for EEG denoiser assessment, encouraging models that are not only accurate but also faithful and explainable.

0.32

Practical flow state detection: Entropy-based EEG classification from portable EEG headbands

eess.SP ·2026-09-17 ·Matin Beiramvand, Reijo Koivula, Tarmo Lipping
published similarity 0.55
Abstract

Flow state, characterized by deep engagement and immersion during challenging activities, represents a valuable mental state with significant implications for learning, performance, and rehabilitation outcomes. While flow has been extensively studied behaviorally, objective neurophysiological detection methods suitable for real-world deployment remain limited. Electroencephalography (EEG) offers a promising avenue for flow detection due to its accessibility, portability, and superior temporal resolution; however, the utility of consumer-grade EEG devices for robust, and subject independent flow classification has been insufficiently explored. This study validates entropy-based biomarkers for flow state detection using two wearable EEG headsets, Muse-S and Emotiv Insight, across 45 participants performing adaptive Tetris gameplay. After denoising, we applied the Discrete Wavelet Transform (DWT) to decompose the signals into multiple frequency sub-bands. From each sub-band, entropy-based features, combining channel-wise measures (Slope Entropy, Distribution Entropy, Spectral Entropy) with cross-channel descriptors (Cross Distribution Entropy, Cross Spectral Entropy) were extracted. These features were then used as input to a Random Forest classifier (RF), evaluated with two validation schemes: Random Sampling (RS) and Leave-One-Subject-Out (LOSO). Under random sampling cross-validation, Random Forest classifiers achieved 97% mean accuracy; under the more rigorous leave-one-subject-out (LOSO) scheme, average accuracy reached 75%, demonstrating genuine cross-subject generalizability. Comprehensive multi-classifier validation (SVM-RBF, GentleBoost, k-NN, Fitted Discriminant, Naive Bayes) confirmed that entropy biomarkers are robust across diverse modeling frameworks.

0.28

A Device to Control and Manipulate Occlusion Effects for Own Voice Perception Studies

eess.AS ·2026-09-11 ·Rouben Rehman, Simon Kersten, Aron Schliep, Janina Fels
similarity 0.53
Abstract

The occlusion effect (OE) refers to changes of the eardrum sound pressure through ear canal occlusion. It consists of two phenomena: an insertion loss (IL) attenuating air-conducted sounds, and an occlusion gain (OG) amplifying bone-conduction. Perceptual research on this is hindered by high variability of the OE across individuals, complicating repeatable presentation of precise OE conditions. Consequently, a method to control OE conditions reproducibly during perceptual experiments is needed. For such investigations, the system must enable separate control of IL and OG. We present an approach based on modified commercial earmuffs with integrated microphones. The design integrates dedicated impedance measurements and the derivation of digital filters, which are applied to the microphone signals to emulate arbitrary OE curves. The system is evaluated objectively through appropriate measurements. Results show that the headphones' inherent OG is guaranteed to be below 6dB above 115Hz, falling below 0dB above 155Hz. Emulation is shown to work accurately over the entire frequency range of interest. Limitations arise mainly due to a slight residual inherent OG for deep voices and the processing delay of the system. Future work will focus on the perceptual evaluation of the system and its application in perceptual studies.

0.20

EMA-Based Subspace Tracking for Adaptive Artifact Subspace Reconstruction

eess.SP ·2026-09-28 ·Vishnu KN, Cota Navin Gupta
code/data similarity 0.53
Abstract · 6 pages, 2 figures, 2 tables. Code: https://github.com/NeuralLabIITGuwahati/EMA-ASR

Electroencephalogram (EEG) artifact removal remains a critical challenge for real-world brain-computer interface deployment due to non-stationary signal statistics and limited calibration availability. Artifact Subspace Reconstruction (ASR) provides an automated framework for variance-based artifact suppression but relies on a static calibration-derived covariance model, limiting stability under intra-subject drift and increasing sensitivity to parameter mis-specification. This work proposes an adaptive ASR framework based on exponential moving average (EMA) subspace tracking. By integrating short-horizon covariance estimation with slow recursive assimilation, the method establishes dual adaptation timescales that enable responsiveness to evolving EEG structure while preserving stability against transient artifacts. This formulation further promotes smoother operating characteristics across rejection thresholds, reducing sensitivity to hyperparameter selection in continuous deployment settings. Evaluated on 24-channel EEG recordings from 10 subjects with prominent blink artifacts across cognitive states, EMA-ASR achieved substantially stronger artifact attenuation than Original and memory-limited ASR variants (53.1% vs. 24.0% and 26.7% blink reduction), at the cost of increased reconstruction and spectral deviation, whereas the memory-limited variant performed comparably to Original ASR. These findings position EMA-based adaptive tracking as a lightweight, deployment-oriented approach to continuous EEG artifact removal under non-stationary conditions, with an explicit trade-off between suppression strength and signal preservation.

0.51