CS Paper Radar

Artifact removal improves electrodermal waveforms but not downstream classification in a virtual-reality balance task

Haochen Chai, Qixu Zhu, Siyao Li, Fangfang Jiang

cs.HC cs.LGeess.SP ·submitted 2026-10-05 21:42 UTC · v1
benchmarkcode/data

Abstract

Artifact removal routinely precedes the classification of electrodermal activity (EDA), on the assumption that a cleaner signal supports a better decision. We tested this assumption in a virtual-reality (VR) balance-disturbance task. A residual gating network was trained on a benchmark with expert-corrected EDA, frozen, and applied to VR recordings, where raw and gated signals were classified by five published time-series methods under identical leave-one-participant-out evaluation. On the benchmark the gate detected artifacts well (median record AUROC 0.94) and reduced error inside artifact regions by 17.8%. In the VR task it did not improve classification. Changes in balanced accuracy ranged from -1.35 to +0.93 percentage points, no classifier improved and two lost accuracy, and all five were equivalent to raw input within +/- 3.32 points. The benefit was lost between waveform and decision. The correction that lowered waveform error also reduced skin conductance response detection in all 43 benchmark records. Processing left 92.8% of predictions unchanged, and the predictions it did change were corrected and corrupted at similar rates. The VR recordings also carried little contamination (an estimated 4.6% of samples), and even perfect localization of deliberately injected artifacts recovered only 3.3 points in the most sensitive classifier. A pooled association between artifact level and accuracy (11.3 points) disappeared within participants (0.1 points), showing how differences between people can make cleaning look useful. Preprocessing should be judged by the decision it supports, against an unprocessed arm.

Comment
10 pages, 9 figures, 3 tables. Code and frozen data: https://github.com/rtb-1005/FairEDA

Closest papers

Nearest neighbours by meaning across the whole index.

A Dry-Contact Ear-EEG System With Continuous Electrode-Skin Impedance Mismatch Monitoring for Motion Artifact Cancellation Using DRL Stimulus

eess.SP eess.SY ·2026-09-02 ·Lohan Atapattu, Sajitha Madugalle, Imasha Nethmal, Erandee Jayathilaka, Avishka Herath +4 more
published similarity 0.60
Abstract · 5 pages, 4 figures, accepted for presentation at IEEE BioCAS 2026

Dry-contact ear-electroencephalography (Ear-EEG) enables wearable neural monitoring. However, motion induced electrode-skin impedance (ESI) mismatches between electrodes can severely degrade signal quality. To the best of our knowledge, this paper presents the first proof-of-concept dry-contact EarEEG system that uses a driven-right-leg (DRL) stimulus for continuous ESI mismatch monitoring, enabling online adaptive motion artifact cancellation. A 1 kHz sinusoidal stimulus is injected through the DRL electrode. The resulting response to the injected carrier is separated from the EEG using bandpass filtering and demodulation, and then used to extract the ESI mismatch information as the reference input for a normalized least-mean-square adaptive filter followed by a Hampel filtering stage. To evaluate artifact suppression and preservation of neural activity, alpha-band EEG activity was analyzed involving four healthy participants performing head nodding, electrode tapping, and jaw clenching. The system achieved artifact power reductions of 6.5, 12.6, and 9.0 dB (77.6%, 92.8%, and 86.4%, respectively) while alpha-band modulation remained clearly observable after processing. This demonstrates the feasibility of DRL-stimulusbased ESI mismatch monitoring for motion artifact cancellation in wearable dry-contact Ear-EEG.

0.38

Beyond Reconstruction: A Unified Framework for Trustworthy and Explainable EEG Artifact Removal Evaluation

eess.SP cs.AI ·2026-11-16 ·Phat Lam, Hung Nguyen, Lam Pham, Huy Phan, Dat Tran +3 more
similarity 0.59
Abstract · IEEE journal manuscript under review

Deep-learning methods have achieved strong performance in EEG artifact removal, but evaluation remains dominated by reconstruction metrics such as error, correlation, and signal-to-noise ratio. Although these metrics assess similarity to clean EEG, they do not establish whether models effectively suppress artifacts, preserve neural activity, or provide reliable explanations. To address these limitations, we propose TriX-EEG, a three-level framework for trustworthy and explainable EEG artifact removal. Level 1, Signal Validity (SV), evaluates reconstruction quality and neural band-power preservation. Level 2, Removal Faithfulness (RF), assesses the removed component through artifact error and residual artifact/neural leakage. Level 3, Explanation Reliability (ER), examines model behavior through temporal alignment, causal relevance, and stability. We evaluate TriX-EEG using nine published neural denoisers across three public benchmarks derived from EEGDenoiseNet and the PhysioNet Motion Artifact Contaminated EEG Dataset, covering EOG, EMG, and motion artifacts. Results show that reconstruction metrics alone are insufficient for trustworthy denoiser assessment: RF complements it by revealing whether errors stem from residual artifact or suppressed neural activity, while ER captures distinct aspects of explanation behavior, supporting joint evaluation of three aspects within a unified framework rather than reliance on any single factor. External validation on an independent EEG/EOG dataset and the BCI Competition IV-2a motor-imagery dataset further demonstrates broadly consistent rankings under dataset shift. Higher-ranked denoisers generally preserve more task-relevant information or cause less downstream performance degradation. Overall, TriX-EEG provides a comprehensive basis for EEG denoiser assessment, encouraging models that are not only accurate but also faithful and explainable.

0.32

Artifact Annotations Partially Substitute for Per-User Calibration: SAFE-EDA and a Normalization-Controlled Evaluation of Wrist-EDA Affect Recognition

cs.LG eess.SP ·2026-10-01 ·Haochen Chai, Xinbi Luo, Zining Liu, Fangfang Jiang
code/data similarity 0.59
Abstract · 12 pages, 6 figures, 6 tables, plus 2 pages of supplementary material. Code: https://github.com/rtb-1005/SAFE-EDA

Wrist electrodermal activity (EDA) differs in amplitude from one person to the next, so affect-recognition models normalize their input before classification. Studies that test such models on held-out subjects seldom report where the normalization statistics come from, yet statistics computed from the held-out subject's own recording give the model information that a device does not have when it is first worn. We asked how this choice alters the measured benefit of pretraining. A compact convolutional network, SAFE-EDA, was pretrained on expert artifact annotations from 43 subjects and compared with the same network trained from scratch on the Wearable Stress and Affect Detection (WESAD) dataset (15 subjects, leave-one-subject-out), with two normalization sources crossed with four window hops. When the statistics came only from training subjects, pretraining raised macro-F1 by 0.078 to 0.227; when they came from the held-out user's full recording, the gain fell to between 0.020 and 0.050 and was no longer significant. Artifact supervision was far more useful than self-supervised pretraining on the same recordings (0.078 versus 0.008). Across 13 configurations in two datasets, the pretrained network was better in 12, but on the second dataset (26 subjects) per-user normalization increased the gain instead of reducing it, so the interaction depends on the data. Only five of 50 published WESAD studies state which data were used for normalization. Reporting this choice is necessary to separate first-use performance from performance after calibration.

0.39

A Proof-of-Concept Study of Weakly Supervised Labeling of Fine-Grained EEG Components for Artifact Attenuation

cs.LG eess.SP ·2026-10-07 ·Lu Wang-Nöth, Hai Huang, Philipp Heiler, Shuqiong Wu, Liyun Zhang +1 more
similarity 0.56
Abstract

Electroencephalography (EEG) is highly susceptible to electromyographic (EMG) artifacts, whose temporal heterogeneity and spatial-spectral overlap with neural activity can leave mixed sources after blind source separation. Existing artifact-removal methods are further limited by scarce reliable component-level ground truth: expert annotations are costly and subjective, while no established method provides realistic simulation-based ground truth for EMG contamination in multichannel scalp EEG. To address these limitations, we propose a framework combining a frequency-aware high-dimensional representation with Multi-Instance Learning. The representation unfolds separated components into frequency-resolved intra-components, creating a space in which mixed neural and muscular activity becomes more separable, while the weakly supervised learning formulation enables artifact-likelihood scores for individual intra-components to be learned from epoch-level labels without finer-grained ground truth. The resulting intra-component classifier supports fine-grained EMG artifact detection and score-guided attenuation. Experiments on held-out subjects show that the framework learns informative intra-component scores and reduces artifact-related spectral deviations most clearly for jaw tension, with moderate effects for raising eyebrows and limited effects for frowning.

0.12

Automated Artifact Removal in EEG Age Prediction: A systematic comparison

eess.SP ·2026-09-25 ·Davoud Hajhassani, Paul-Adrien Graignic, Bruno Aristimunha, Apolline Mellot, Tom Mariani +6 more
similarity 0.55
Abstract

Automated EEG artifact removal may improve downstream analysis but can also alter predictive information. We benchmarked nine automated artifact removal methods against a common no-artifact-removal baseline for cross-dataset EEG age prediction. We introduce Signal Quality Index (SQI)-guided GEDAI, which leverages local signal-quality assessment to restrict correction to the channel--epoch pairs requiring intervention. Three deep neural architectures were trained on TUEG and evaluated without target-domain fitting on ds005385, LEMON, and TDBRAIN. Across this setting, GEDAI and SQI-guided GEDAI were the only methods with consistent gains over baseline in age prediction performance across all datasets and architectures ($Δ$MAE $=-0.77/-0.64$ years, $ΔR^2=+0.083/+0.072$, respectively). The remaining methods were neutral or detrimental on average ($Δ$MAE $=+0.22\pm0.16$ years, $ΔR^2=-0.023\pm0.016$ across methods). The two GEDAI-based methods achieved closely matched performance, while SQI guidance reduced the median modification ratio from $74.78\%$ to $42.80\%$. These findings show that curation benefits are method-dependent and establish SQI guidance as a more selective operating point, leaving more of the original EEG unchanged and limiting the potential loss of neural activity while retaining most of GEDAI's predictive benefit.

0.34

When Temporal Perturbations Act Like Sensor Biases: Label-Free Auditing of Wearable Activity Recognizers

cs.LG cs.AIcs.CR ·2026-09-24 ·Qingyu Wu, Yuan Wei, Renju Liu, Hua Cheng
similarity 0.55
Abstract

Wearable human-activity recognition (HAR) models operate across sensors, subjects, and backbones, yet a smooth waveform may appear temporal while exploiting a persistent sensor offset primarily. We introduce SpectrumAudit, a label-sealed audit that fits a phase-randomized full-window stimulus on calibration windows from subjects held out from training and testing. After selection, it replays its exact DC projection and budget-constrained zero-mean residual on the same frozen victim without refitting. Across 27 victims from three datasets and three backbones, the selected waveforms cause 2.87-40.83-point three-phase robust accuracy losses. Under this replay budget, DC is more damaging than AC on 24/27 victims and recovers at least 90% of the full drop on 22/27; all 5 failures occur on WISDM. In a held-out UTD-MHAD check, the selected waveform causes 13.49-pp accuracy and 11.68-pp macro-F1 losses, versus -0.66 pp for matched random changes. The audit diagnoses offset versus zero-mean variation under a common peak-budget cap. The code will be released upon acceptance.

0.34

Toward Postural State Classification in Immersive VR with Multimodal Data and Explainability Analysis

cs.HC cs.AIcs.LG ·2026-08-28 ·Nipa Anjum, Md Irfan Pavel, Robert Gonzalez, Kevin Desai, Alberto Cordova +2 more
top venuecode/data similarity 0.55
Abstract · Accepted in The 25th IEEE International Symposium on Mixed and Augmented Reality (ISMAR)

Ensuring a safe virtual reality (VR) experience requires systems that can predict and respond when users lose their balance. Although prior work has examined fall prediction and motion sickness, many approaches are regression-based and postural state classification remains less explored. This study compares machine learning (ML) and deep learning (DL) models for classifying postural states in VR under visual perturbations. We used a multimodal dataset containing kinematic, electromyographic (EMG), and electrodermal activity (EDA) signals. The data were prepared for a binary task to distinguish balanced from imbalanced postural states, and participant-wise downsampling addressed class imbalance. All models were evaluated with Leave-One-Participant-Out (LOPO) cross-validation to test generalization to unseen participants. Among the models, the Mamba-inspired CNN (MI-CNN) achieved the highest accuracy of 96.76%. SHapley Additive exPlanations (SHAP) analysis improved interpretability and identified the most influential classification factors. The SHAP results showed that kinematic features were dominant, indicating that body-motion patterns are informative for detecting imbalance in VR. We also evaluated MI-CNN using only the top two-thirds of features ranked by SHAP importance. Despite a 33% reduction in input dimensionality, the model maintained performance, achieving 0.957 accuracy and 0.957 F1-score, with about a 1% decrease compared with the full-feature model. These findings suggest that multimodal sensing, temporal deep learning, and explainable AI can support reliable classification of balance-related instability in VR. Accurate recognition of imbalanced postural states may raise awareness of fall risk and guide safer, adaptive VR systems that respond to instability while improving user safety and experience. Code is available at: https://github.com/NipaAnjum/MI-CNN.

0.45

Decoding Decision Correctness from EEG Under High Cognitive Workload in Virtual Reality: Implications for Collaborative Brain-Computer Interface Teams

cs.HC ·2026-09-02 ·Christopher Baker, Stephen Hinton, Tom Reed, Stephen Fairclough
similarity 0.54
Abstract

Collaborative Brain-Computer Interfaces (cBCIs) offer a promising mechanism to augment team decision-making, but existing approaches rely exclusively on evidence available only after a decision has been made and reported, such as reaction time or stated confidence. This limits their use to explaining or discounting a decision after the fact, rather than informing a team's response before it is finalised. We tested whether spatial-covariance EEG features could instead provide a genuinely pre-emptive signal of an operator's decision correctness, available within the response window itself, and whether such a signal depends on cognitive workload. Using a continuous virtual reality target-detection task, participants (N = 23) completed a within-subject workload manipulation (High vs. Low). At the team level, weighting votes by this pre-emptive neural signal, available before a response is committed, produced substantial accuracy gains on contested (evenly-split) trials under High Workload (57% to 88% as team size increased from 2 to 16), but was actively detrimental under Low Workload. Critically, this advantage held even against post-hoc behavioural signals: confidence was the strongest single team-level signal overall, but by definition cannot inform a decision still in progress, whereas the neural signal can. These findings indicate that EEG-based decision-reliability signals are not a general-purpose team augmentation tool, but a workload-conditional one, with clear implications for when and how cBCI systems should be deployed in operational teams.

0.32