CS Paper Radar

Artifact Annotations Partially Substitute for Per-User Calibration: SAFE-EDA and a Normalization-Controlled Evaluation of Wrist-EDA Affect Recognition

Haochen Chai, Xinbi Luo, Zining Liu, Fangfang Jiang

cs.LG eess.SP ·submitted 2026-10-01 13:45 UTC · v1
code/data

Abstract

Wrist electrodermal activity (EDA) differs in amplitude from one person to the next, so affect-recognition models normalize their input before classification. Studies that test such models on held-out subjects seldom report where the normalization statistics come from, yet statistics computed from the held-out subject's own recording give the model information that a device does not have when it is first worn. We asked how this choice alters the measured benefit of pretraining. A compact convolutional network, SAFE-EDA, was pretrained on expert artifact annotations from 43 subjects and compared with the same network trained from scratch on the Wearable Stress and Affect Detection (WESAD) dataset (15 subjects, leave-one-subject-out), with two normalization sources crossed with four window hops. When the statistics came only from training subjects, pretraining raised macro-F1 by 0.078 to 0.227; when they came from the held-out user's full recording, the gain fell to between 0.020 and 0.050 and was no longer significant. Artifact supervision was far more useful than self-supervised pretraining on the same recordings (0.078 versus 0.008). Across 13 configurations in two datasets, the pretrained network was better in 12, but on the second dataset (26 subjects) per-user normalization increased the gain instead of reducing it, so the interaction depends on the data. Only five of 50 published WESAD studies state which data were used for normalization. Reporting this choice is necessary to separate first-use performance from performance after calibration.

Comment
12 pages, 6 figures, 6 tables, plus 2 pages of supplementary material. Code: https://github.com/rtb-1005/SAFE-EDA

Closest papers

Nearest neighbours by meaning across the whole index.

From Stress to Affect: Multimodal Deep Learning for Physiological Emotion Recognition Across Wearable Sensor Modalities

cs.LG ·2026-09-17 ·Desta Haileselassie Hagos, Saurav Keshari Aryal, Legand L. Burge
similarity 0.59
Abstract · Under review

Physiological emotion recognition using wearable sensors has important applications in mental health monitoring, affective computing, and human-computer interaction. However, existing studies typically evaluate a single model, sensing configuration, or dataset, limiting our understanding of how these factors influence recognition performance. We present a comparative study of temporal deep learning architectures for physiological emotion recognition using two multimodal wearable datasets: WESAD and EmoWear. Bidirectional long short-term memory (LSTM), temporal convolutional network (TCN), and Transformer models are evaluated under wrist-only, chest-only, and multimodal sensing configurations using participant-independent leave-one-subject-out cross-validation (LOSO-CV). We also investigate soft-voting ensembles, sensor ablation, sampling frequency, and gradient-based saliency. The Transformer achieved the highest multimodal accuracy on WESAD (99.02% +/- 0.51%), whereas the LSTM achieved the best multimodal accuracy on EmoWear for both arousal (91.80% +/- 1.06%) and valence (89.96% +/- 0.36%). These results show that relative architecture performance depends on dataset characteristics rather than one architecture being uniformly superior. Multimodal sensing consistently outperformed wrist-only and chest-only configurations across both datasets. Sampling-frequency analysis showed that 4 Hz provides a practical operating point, with performance comparable to higher frequencies at substantially lower training cost. These findings provide guidance for selecting architectures, sensing modalities, and sampling frequencies for wearable physiological emotion recognition.

0.09

Artifact removal improves electrodermal waveforms but not downstream classification in a virtual-reality balance task

cs.HC cs.LGeess.SP ·2026-10-05 ·Haochen Chai, Qixu Zhu, Siyao Li, Fangfang Jiang
benchmarkcode/data similarity 0.59
Abstract · 10 pages, 9 figures, 3 tables. Code and frozen data: https://github.com/rtb-1005/FairEDA

Artifact removal routinely precedes the classification of electrodermal activity (EDA), on the assumption that a cleaner signal supports a better decision. We tested this assumption in a virtual-reality (VR) balance-disturbance task. A residual gating network was trained on a benchmark with expert-corrected EDA, frozen, and applied to VR recordings, where raw and gated signals were classified by five published time-series methods under identical leave-one-participant-out evaluation. On the benchmark the gate detected artifacts well (median record AUROC 0.94) and reduced error inside artifact regions by 17.8%. In the VR task it did not improve classification. Changes in balanced accuracy ranged from -1.35 to +0.93 percentage points, no classifier improved and two lost accuracy, and all five were equivalent to raw input within +/- 3.32 points. The benefit was lost between waveform and decision. The correction that lowered waveform error also reduced skin conductance response detection in all 43 benchmark records. Processing left 92.8% of predictions unchanged, and the predictions it did change were corrected and corrupted at similar rates. The VR recordings also carried little contamination (an estimated 4.6% of samples), and even perfect localization of deliberately injected artifacts recovered only 3.3 points in the most sensitive classifier. A pooled association between artifact level and accuracy (11.3 points) disappeared within participants (0.1 points), showing how differences between people can make cleaning look useful. Preprocessing should be judged by the decision it supports, against an unprocessed arm.

0.40

Electrodermal Activity (EDA) for Stress Detection: A Comprehensive Survey and Benchmark

eess.SP ·2026-09-18 ·Gang Liu, Zixiong Ning
surveybenchmark similarity 0.58
Abstract · 19 pages, 5 figures, 7 tables

Electrodermal activity (EDA) is widely used for pervasive stress monitoring because of its sensitivity to sympathetic arousal and its computational efficiency. However, research remains fragmented: studies concentrate on a small subset of available datasets, preprocessing and evaluation protocols are inconsistent, and widely adopted methodological conventions remain unvalidated. Existing reviews summarize these practices without evaluating them under a common protocol. To bridge these gaps, this paper presents a comprehensive survey and benchmark for EDA-based stress detection. We review the technical pipeline from preprocessing to modeling and compile 26 public datasets and 22 representative unimodal studies to inform future dataset selection and methodological design. Under a subject-independent protocol spanning five diverse datasets, we benchmark decomposition, filtering, and channel-input choices alongside a broad range of machine learning (ML) and deep learning (DL) models in both in-domain and cross-domain transfer settings. Our results provide the first multi-dataset validation of cvxEDA, the default decomposition method, show that feature-based ML outperforms end-to-end (E2E) DL, and identify ecological validity as a key factor in cross-domain transfer. We conclude with directions toward robust, data-efficient, and trustworthy deployment.

0.22

WearableBridge: Task-Guided Latent Transport for Free-Living Activity Recognition

cs.LG ·2026-11-06 ·Jingjing Zou, Yixin Wang
code/data similarity 0.57
Abstract · 26 pages, 5 figures, 11 tables. Code and interactive demo: https://github.com/jingjingz/WearableBridge

Wrist-worn accelerometers make activity monitoring feasible at scale, but incidental arm motion, device orientation, and shifting context blur the signal that separates activities. Calibration studies supply higher-quality references such as concurrent thigh recordings or supervised laboratory wrist sessions, but they are expensive, cover few participants, and are rarely available at deployment. How can limited reference data improve recognition for participants who wear only a wrist device? We propose WearableBridge, which holds the reference encoder and classifier fixed and learns a task-guided transport map, the bridge, that carries each wrist feature into the region the classifier associates with its activity. Reference features or the classifier's predictions indicate the destination, and a classification loss penalizes wrist features that land in the region of another activity. We instantiate WearableBridge with three bridges: Mapper regresses onto reference features, Distillation matches the classifier's class probabilities, and MeanFlow learns a one-step flow from wrist toward reference features. On 40 held-out free-living PAAWS participants, all three bridges improve macro-F1 in every training run, and the strongest, MeanFlow, raises mean macro-F1 from 35.1% to 56.0% with concurrent thigh references (Thigh2Wrist), and from 54.0% to 63.5% with group-matched laboratory wrist references (Lab2Freeliving). Fitted only on PAAWS, MeanFlow also raises macro-F1 on the CAPTURE-24 cohort from 42.8% to 54.7%. The gains replicate on selfBACK, hold across four reference encoders, and grow with temporal context. A study can therefore collect reference recordings for a calibration subset and improve wrist-only recognition for every other participant, training only a bridge of 0.13 to 2.44 million parameters while the reference encoder and classifier stay unchanged.

0.29

When Clean Signals Are Not Enough: Detecting Structural Ambiguity for Safe Wearable Stress Classification

cs.AI ·2026-08-19 ·Saba A. Farahani, Hung Cao, Amir M. Rahmani
published similarity 0.56
Abstract · 4 pages, 3 figures, 1 table. Accepted at the 2026 IEEE 22nd International Conference on Body Sensor Networks (BSN 2026)

Wearable stress classifiers can achieve strong average performance while failing completely for a particular individual. On WESAD, a Random Forest reaches 93.0% mean accuracy yet yields F1 = 0 for Subject 14, whose cross-signal coupling weakens near stress onset. We call this structural ambiguity: individually plausible physiological channels form an inter-signal pattern that is poorly supported by the person's non-stress reference. We introduce the Individual Conformal Coupling Monitor (ICCM), a lightweight and transparent pre-inference monitor that quantifies subject-specific coupling divergence and routes each window to classify, defer, or abstain without retraining the downstream classifier. Across WESAD (N = 15) and Stress-Predict (N = 35), full-cohort Pearson associations between ambiguity and accuracy are negative (r = -0.607, p = 0.016; r = -0.412, p = 0.014). Robustness analyses temper this finding: rank correlations are not significant, and the WESAD association disappears when Subject 14 is removed. ICCM changes false-positive counts from 29 to 27 and 94 to 92, although neither paired change is significant. It withholds 3 of Subject 14's 21 stress windows but does not repair the missed-stress failure. These results position ICCM as an interpretable signal of unsupported physiology and individual failure, rather than a stand-alone safety guarantee.

0.20

When Adaptation Hurts: Split Sensitivity and Person-Level Negative Transfer in Federated Wearable Onboarding

cs.LG cs.DC ·2026-08-18 ·Rahil Aftab, Vineet Kumar Rakesh, Soumya Mazumdar, Tapas Samanta
benchmarktheorycode/data similarity 0.55
Abstract · 14 pages, 2 figures, 4 tables; supplementary material included. Code and supplementary scripts: https://github.com/TitanRahil/When-Adaptatio…

Federated wearable models eventually serve people absent from source training, but favorable average accuracy does not establish that unlabeled onboarding helps each person. We evaluate six core onboarding strategies on five wearable datasets under a leakage-controlled protocol that fixes source checkpoints, estimates normalization from source data only, separates calibration from evaluation recordings, and performs inference over held-out people rather than windows, devices, or random seeds. Completing all eligible HHAR and PAMAP2 outer-person rotations materially changes the conclusion obtained from the original frozen fold. On HHAR, balanced accuracy on that single person is 95.6-97.2% across methods versus 78.3-83.0% over all nine users, a reduction of 13.8-17.8 percentage points (pp). The displayed mean leader changes on both datasets, while paired leader-runner bootstrap intervals include zero and do not resolve a superior method. No adaptive core mechanism combines positive mean gain in all five datasets with zero seed-averaged person-level losses greater than 2 percentage points (pp). FedBN has one such loss and ATP-style adaptation has eight; Feature-only has none after seed averaging, but its exact one-sided 95% upper bound is 7.6%. A complementary seed-person stress audit records 4, 22, and 10 harmful realizations out of 114 for FedBN, ATP-style, and Feature-only, respectively; these are repeated realizations, not independent participants. Tail quality, calibration availability, and fall-window specificity reveal additional failures hidden by mean accuracy. The study therefore provides an auditable development benchmark and failure map rather than a universal-superiority or deployment-safety claim.

0.37

EMGBlend: Heterogeneity-Aware Self-Supervised Pretraining for Gesture and Force Decoding

cs.LG cs.AI ·2026-09-22 ·Yuwei Jia, Cheng Zhong, Jinyang Yu, Zhe Cui
code/data similarity 0.55
Abstract

Public surface electromyography (EMG) datasets vary widely in electrode layout, channel count, frequency support, and size. Simply mixing them for pretraining can misalign channel semantics, introduce spectral targets that some devices cannot observe, and let large or high-channel-count datasets dominate learning. We introduce EMGBlend, a self-supervised framework designed around these differences. It combines shared channel patches with geometry-aware attention, restricts spectral targets to each recording's supported frequency band, and balances exposure across data sources. We pretrain a 109M-parameter model on 11 public EMG sources and evaluate it on gesture recognition, continuous-force regression, and contact classification. EMGBlend consistently outperforms matched random initialization and waveform reconstruction controls. Fixed-budget source controls show that multi-source pretraining improves gesture recognition and remains competitive for force decoding. Ablations confirm that geometry, band-aware targets, and source balancing each contribute to transfer, although cross-person NinaPro force estimation remains difficult. Overall, EMGBlend shows how heterogeneous EMG datasets can be combined through explicit mechanism design rather than simple concatenation. Code is available at https://github.com/tamanano/EMGBlend

0.25

EMG-FM-Bench: A Comprehensive Benchmark for Foundation Model Transfer and Adaptation on Electromyography

cs.LG ·2026-10-05 ·Tianhao Wu, Jiawei Yu, Xiangdong Hu, Xu Wu, Hongyu Wu +6 more
benchmark similarity 0.55
Abstract

Foundation models (FMs) are increasingly being developed for general time series and physiological signals, yet their transferability to downstream physiological tasks remains poorly understood. This question is particularly challenging for electromyography (EMG), where signal distributions vary substantially across users, sensing configurations, acquisition hardware, and downstream tasks. We introduce EMG-FM-Bench, a systematic benchmark for studying foundation-model transfer and adaptation on EMG. EMG-FM-Bench unifies 20 public datasets with over 1 million EMG segments and evaluates nine pretrained foundation models across four questions: how pretrained models perform when frozen or fully fine-tuned, how much pretraining helps compared with training the same model from scratch, how well models generalize to new users with limited labeled data, and how performance changes across different EMG tasks. Across the benchmark, linear probing provides useful information about pretrained representations, but full fine-tuning can substantially change downstream EMG performance. Comparing each pretrained model with the same model trained from scratch shows that the benefit of pretraining varies substantially across models and is not universal. Performance decreases when models are evaluated on new users, while five-shot adaptation improves macro-F1 in 70.2% of evaluated model-dataset combinations but recovers only part of the lost performance. Model performance is highly consistent between upper- and lower-limb classification and remains strongly correlated with continuous EMG-to-text decoding. Together, these results provide a systematic view of when pretrained time-series models transfer effectively to EMG and how their performance depends on fine-tuning, user variation, and downstream task.

0.19