CS Paper Radar

EMG-FM-Bench: A Comprehensive Benchmark for Foundation Model Transfer and Adaptation on Electromyography

Tianhao Wu, Jiawei Yu, Xiangdong Hu, Xu Wu, Hongyu Wu, Sidharth Anupkrishnan, Amirmohammad Radmehr, Yi Chen Liu, Phuc Nguyen, Yi Wu, Jian Liu

cs.LG ·submitted 2026-10-05 14:53 UTC · v2
benchmark

Abstract

Foundation models (FMs) are increasingly being developed for general time series and physiological signals, yet their transferability to downstream physiological tasks remains poorly understood. This question is particularly challenging for electromyography (EMG), where signal distributions vary substantially across users, sensing configurations, acquisition hardware, and downstream tasks. We introduce EMG-FM-Bench, a systematic benchmark for studying foundation-model transfer and adaptation on EMG. EMG-FM-Bench unifies 20 public datasets with over 1 million EMG segments and evaluates nine pretrained foundation models across four questions: how pretrained models perform when frozen or fully fine-tuned, how much pretraining helps compared with training the same model from scratch, how well models generalize to new users with limited labeled data, and how performance changes across different EMG tasks. Across the benchmark, linear probing provides useful information about pretrained representations, but full fine-tuning can substantially change downstream EMG performance. Comparing each pretrained model with the same model trained from scratch shows that the benefit of pretraining varies substantially across models and is not universal. Performance decreases when models are evaluated on new users, while five-shot adaptation improves macro-F1 in 70.2% of evaluated model-dataset combinations but recovers only part of the lost performance. Model performance is highly consistent between upper- and lower-limb classification and remains strongly correlated with continuous EMG-to-text decoding. Together, these results provide a systematic view of when pretrained time-series models transfer effectively to EMG and how their performance depends on fine-tuning, user variation, and downstream task.

Closest papers

Nearest neighbours by meaning across the whole index.

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

cs.LG ·2026-10-01 ·Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu +2 more
similarity 0.72
Abstract · The authors are withdrawing this manuscript because the current experimental evaluation and validation are insufficient to adequately suppor…

Electromyography (EMG) signals vary substantially across individuals, body regions, recording sessions, and sensing hardware, limiting the generalization of models for assistive devices and human-computer interaction. Existing time-series foundation models are also computationally expensive for real-time wearable deployment and often fail to capture EMG-specific time-frequency characteristics. We present LiteEMG-FM, an efficient hybrid CNN-Transformer foundation model for practical EMG sensing. Pretrained on 16 diverse upper- and lower-limb EMG datasets, LiteEMG-FM learns representations that generalize across users and datasets. For resource-constrained deployment, we implement a hierarchical wake-up architecture in which a lightweight, always-on 1D-CNN filters rest and non-target activity and activates LiteEMG-FM only for valid gestures. We evaluate full inference offloading, split inference, and full on-device processing, characterizing their trade-offs in latency, power consumption, and memory footprint. Across diverse evaluation settings, LiteEMG-FM outperforms state-of-the-art time-series foundation models and supervised baselines, particularly under zero-calibration cross-participant and data-scarce conditions. These results demonstrate that LiteEMG-FM is an effective, efficient, and deployable foundation model for EMG applications.

0.11

Benchmarking EEG Foundation Models at Scale: Lessons from 20,000 Evaluations

cs.LG eess.SP ·2026-09-26 ·Zhige Chen, Shu Peng, Chengxuan Qin, Rui Liu, Rui Yang +2 more
benchmarkcode/data similarity 0.69
Abstract · 91 pages, including appendices and supplementary material

Electroencephalography (EEG) foundation models (FMs) promise transferable neural representations, yet their advantages over strong supervised baselines and their prospects for further scaling remain unclear. To address these questions, we introduce EEG-Arena, an open-source benchmark covering 30 EEG FMs and 25 supervised baselines evaluated on 57 downstream tasks from 23 public datasets. Through more than 20,000 evaluations across five experimental protocols, we assess downstream performance, pretraining benefits, model size scaling, pretraining data scaling, and robustness to channel configuration. We find that (1) EEG FMs outperform strong task-specific supervised baselines on most evaluated tasks, particularly under non-bipolar settings; (2) compared with architecture-matched supervised training from scratch, pretraining improves both early optimization and final downstream performance, with larger and more consistent gains as more labeled downstream data become available; (3) existing EEG FMs do not exhibit a consistent positive relationship between parameter count and downstream performance; (4) under a fixed architecture, increasing the pretraining data scale yields sustained downstream gains; and (5) channel-flexible FMs achieve higher absolute performance than channel-constrained models across most evaluated channel configurations. Together, these findings demonstrate the downstream value of EEG FMs and identify pretraining data expansion as a promising direction for further progress. To support continued research, we release EEG-Arena as an open-source evaluation framework that provides shared infrastructure for reproducible benchmarking, model comparison, and community-driven development.

0.56

EMGBlend: Heterogeneity-Aware Self-Supervised Pretraining for Gesture and Force Decoding

cs.LG cs.AI ·2026-09-22 ·Yuwei Jia, Cheng Zhong, Jinyang Yu, Zhe Cui
code/data similarity 0.69
Abstract

Public surface electromyography (EMG) datasets vary widely in electrode layout, channel count, frequency support, and size. Simply mixing them for pretraining can misalign channel semantics, introduce spectral targets that some devices cannot observe, and let large or high-channel-count datasets dominate learning. We introduce EMGBlend, a self-supervised framework designed around these differences. It combines shared channel patches with geometry-aware attention, restricts spectral targets to each recording's supported frequency band, and balances exposure across data sources. We pretrain a 109M-parameter model on 11 public EMG sources and evaluate it on gesture recognition, continuous-force regression, and contact classification. EMGBlend consistently outperforms matched random initialization and waveform reconstruction controls. Fixed-budget source controls show that multi-source pretraining improves gesture recognition and remains competitive for force decoding. Ablations confirm that geometry, band-aware targets, and source balancing each contribute to transfer, although cross-person NinaPro force estimation remains difficult. Overall, EMGBlend shows how heterogeneous EMG datasets can be combined through explicit mechanism design rather than simple concatenation. Code is available at https://github.com/tamanano/EMGBlend

0.25

EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate

eess.SP cs.HCcs.LG ·2026-10-23 ·Raul C. Sîmpetru, Amin Olamazadeh, Devon Rohlf, Vlad Cnejevici, Alessandro Del Vecchio
benchmark similarity 0.68
Abstract · 11 pages, 7 figures; 12-page supplement included. Supplementary Data 1-9 (CSV) are provided as ancillary files

Wireless electromyography (EMG) interfaces must balance electrode coverage against transmission bandwidth. Here, we show that compact EMG tokens substantially reduce payload while retaining information for three-dimensional hand-pose decoding. We evaluate two causal tokenizers fitted without pose labels: an encoder pretrained to reconstruct EMG spectra and one based on SPAR, an engineered spectral-spatial representation of neighbouring electrodes. In personalized, within-session experiments with 320-channel EMG from nine participants, we compare tokenized and continuous features using matched decoder architectures and training procedures. Averaged across decoders, tokenization changed mean error by +0.01 mm for SPAR (95% confidence interval: -0.12 to 0.14) and +0.45 mm for the learned representation (0.10 to 0.82). Both increases met a 1 mm non-inferiority criterion. Stored token arrays reduced payloads 41-fold relative to raw EMG and 36-fold relative to continuous SPAR features. On sampled windows of the public emg2pose benchmark's test partition, absolute differences in mean error between learned tokens and continuous features were below 0.05 mm across 176 participants and in the subset of 20 participants unseen during training. Electrode coverage, calibration, and unseen recordings affected SPAR decoding more than quantization did. In a computational benchmark, optimized SPAR generated tokens for 63 channels within 20 ms on a Cortex-M55 microcontroller. These findings support tokenization as a compact interface between wearable sensing and movement decoding, allowing decoders to be updated while the wearable encoder and transmitted representation remain fixed.

0.29

BRIDGE-EEG: Bridging Self-Supervised Pretraining and Efficient Deployment for Cross-Dataset EEG Classification

cs.HC cs.LGeess.SP ·2026-09-10 ·Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu, Gourav Datta, Shreyas Sen
similarity 0.65
Abstract · 11 pages, 7 figures 8 tables, journal submission

The growing use of electroencephalography (EEG) motivates automated analysis that is accurate, transferable, and deployable on constrained hardware. Recent EEG foundation models learn general representations from large-scale pretraining, but their size and computational cost limit edge and wearable deployment. We introduce BRIDGE-EEG, an efficient multi-task EEG classification pipeline that preserves the benefits of pretraining while reducing model size. A unified preprocessing scheme maps heterogeneous recordings with different channel counts, montages, and sampling rates to a device-agnostic 62-channel time--frequency representation. We pretrain an SE-ResNet18 teacher (11.84 M parameters) with SimCLR on unlabeled EEG from five heterogeneous datasets, then compress it into SE-ResNet8 (1.56 M) and SE-ResNet4 (0.48 M) students using task-agnostic and task-specific distillation. We evaluate six benchmarks spanning abnormality detection, motor imagery, and emotion recognition. For abnormality detection and emotion recognition, the students achieve accuracy comparable to or better than several recent EEG foundation models with 10--1,000$\times$ more parameters. Motor imagery shows a remaining representation gap, highlighting the importance of pretraining diversity. Inference profiling on a server GPU, desktop CPU, and NVIDIA Jetson Orin Nano shows up to 3.0$\times$ lower edge energy per inference (15.64 mJ vs. 46.67 mJ). The compact models further support future deployment on MCU-class wearables.

0.21

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.64
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

MyoCodec: A Streaming Neural Codec for Electromyography

eess.SP cs.AI ·2026-09-29 ·Jihwan Lee, Kleanthis Avramidis, Junhyeok Lee, Tiantian Feng, Najim Dehak +1 more
code/data similarity 0.64
Abstract

Neural codecs encode continuous signals into compact sequences of discrete tokens, providing an interface for efficient transmission, storage, and token-based sequence modeling. This paradigm has been widely adopted in modern speech and audio frameworks; however, the biosignal domain still lacks a neural codec designed specifically for low-bitrate streaming and generalization across diverse downstream tasks. We present MyoCodec, a streaming neural codec designed for electromyography (EMG). Inspired by recent neural audio codecs, MyoCodec combines causal Transformers with residual vector quantization to encode continuous EMG signals into different levels of EMG representations spanning from continuous latent features to discrete tokens operating at 50 Hz. Trained on twelve public EMG datasets, MyoCodec achieves favorable performance in both intrinsic codec quality and representative downstream tasks, including typing (emg2qwerty), hand-pose (emg2pose), speech decoding (emg2speech), and speech-to-EMG synthesis (speech2emg). Across these tasks, MyoCodec exhibits strong performance against prior models while providing a compact and causal EMG representation. During streaming inference, it requires compute time of only 0.482 ms for each 20 ms frame, enabling real-time streaming. Also, the discrete token representation provided by MyoCodec has the potential to support integration into language-model based approaches, creating a path toward LLM-based interactive systems, where tokenized EMG representations are directly processed into such language or speech models. Code and model weights are released.

0.32

EMG-GPT: Predictive Pretraining on Residual-Quantized EMG Tokens for Hand Pose Estimation

cs.LG cs.AI ·2026-10-04 ·Ettore Magni, Rolandos Alexandros Potamias, Stefanos Zafeiriou, Konstantinos Barmpas
similarity 0.63
Abstract

Surface electromyography (sEMG) is a low-power, cost-effective biosignal for hand-pose estimation and gesture classification. In this work, we examine whether self-supervised pretraining on sEMG can yield transferable representations for continuous hand-pose estimation. We introduce EMG-GPT, a causal transformer-based model that operates on discrete sEMG representations from a frozen residual vector quantization (RVQ) tokenizer and learns temporal dynamics through depth-autoregressive future-code prediction. The model combines within-frame integration with causal temporal modeling while preserving the geometry of the pretrained codebook. EMG-GPT shows competitive results in both Regression and Tracking tasks, supporting EMG-only pretraining as a viable approach for learning transferable sEMG representations.

0.12