Wireless electromyography (EMG) interfaces must balance electrode coverage against transmission bandwidth. Here, we show that compact EMG tokens substantially reduce payload while retaining information for three-dimensional hand-pose decoding. We evaluate two causal tokenizers fitted without pose labels: an encoder pretrained to reconstruct EMG spectra and one based on SPAR, an engineered spectral-spatial representation of neighbouring electrodes. In personalized, within-session experiments with 320-channel EMG from nine participants, we compare tokenized and continuous features using matched decoder architectures and training procedures. Averaged across decoders, tokenization changed mean error by +0.01 mm for SPAR (95% confidence interval: -0.12 to 0.14) and +0.45 mm for the learned representation (0.10 to 0.82). Both increases met a 1 mm non-inferiority criterion. Stored token arrays reduced payloads 41-fold relative to raw EMG and 36-fold relative to continuous SPAR features. On sampled windows of the public emg2pose benchmark's test partition, absolute differences in mean error between learned tokens and continuous features were below 0.05 mm across 176 participants and in the subset of 20 participants unseen during training. Electrode coverage, calibration, and unseen recordings affected SPAR decoding more than quantization did. In a computational benchmark, optimized SPAR generated tokens for 63 channels within 20 ms on a Cortex-M55 microcontroller. These findings support tokenization as a compact interface between wearable sensing and movement decoding, allowing decoders to be updated while the wearable encoder and transmitted representation remain fixed.

Comment
11 pages, 7 figures; 12-page supplement included. Supplementary Data 1-9 (CSV) are provided as ancillary files

Closest papers

Nearest neighbours by meaning across the whole index.

EMGBlend: Heterogeneity-Aware Self-Supervised Pretraining for Gesture and Force Decoding

cs.LG cs.AI ·2026-09-22 ·Yuwei Jia, Cheng Zhong, Jinyang Yu, Zhe Cui
code/data similarity 0.69
Abstract

Public surface electromyography (EMG) datasets vary widely in electrode layout, channel count, frequency support, and size. Simply mixing them for pretraining can misalign channel semantics, introduce spectral targets that some devices cannot observe, and let large or high-channel-count datasets dominate learning. We introduce EMGBlend, a self-supervised framework designed around these differences. It combines shared channel patches with geometry-aware attention, restricts spectral targets to each recording's supported frequency band, and balances exposure across data sources. We pretrain a 109M-parameter model on 11 public EMG sources and evaluate it on gesture recognition, continuous-force regression, and contact classification. EMGBlend consistently outperforms matched random initialization and waveform reconstruction controls. Fixed-budget source controls show that multi-source pretraining improves gesture recognition and remains competitive for force decoding. Ablations confirm that geometry, band-aware targets, and source balancing each contribute to transfer, although cross-person NinaPro force estimation remains difficult. Overall, EMGBlend shows how heterogeneous EMG datasets can be combined through explicit mechanism design rather than simple concatenation. Code is available at https://github.com/tamanano/EMGBlend

0.25

EMG-GPT: Predictive Pretraining on Residual-Quantized EMG Tokens for Hand Pose Estimation

cs.LG cs.AI ·2026-10-04 ·Ettore Magni, Rolandos Alexandros Potamias, Stefanos Zafeiriou, Konstantinos Barmpas
similarity 0.68
Abstract

Surface electromyography (sEMG) is a low-power, cost-effective biosignal for hand-pose estimation and gesture classification. In this work, we examine whether self-supervised pretraining on sEMG can yield transferable representations for continuous hand-pose estimation. We introduce EMG-GPT, a causal transformer-based model that operates on discrete sEMG representations from a frozen residual vector quantization (RVQ) tokenizer and learns temporal dynamics through depth-autoregressive future-code prediction. The model combines within-frame integration with causal temporal modeling while preserving the geometry of the pretrained codebook. EMG-GPT shows competitive results in both Regression and Tracking tasks, supporting EMG-only pretraining as a viable approach for learning transferable sEMG representations.

0.12

EMG-FM-Bench: A Comprehensive Benchmark for Foundation Model Transfer and Adaptation on Electromyography

cs.LG ·2026-10-05 ·Tianhao Wu, Jiawei Yu, Xiangdong Hu, Xu Wu, Hongyu Wu +6 more
benchmark similarity 0.68
Abstract

Foundation models (FMs) are increasingly being developed for general time series and physiological signals, yet their transferability to downstream physiological tasks remains poorly understood. This question is particularly challenging for electromyography (EMG), where signal distributions vary substantially across users, sensing configurations, acquisition hardware, and downstream tasks. We introduce EMG-FM-Bench, a systematic benchmark for studying foundation-model transfer and adaptation on EMG. EMG-FM-Bench unifies 20 public datasets with over 1 million EMG segments and evaluates nine pretrained foundation models across four questions: how pretrained models perform when frozen or fully fine-tuned, how much pretraining helps compared with training the same model from scratch, how well models generalize to new users with limited labeled data, and how performance changes across different EMG tasks. Across the benchmark, linear probing provides useful information about pretrained representations, but full fine-tuning can substantially change downstream EMG performance. Comparing each pretrained model with the same model trained from scratch shows that the benefit of pretraining varies substantially across models and is not universal. Performance decreases when models are evaluated on new users, while five-shot adaptation improves macro-F1 in 70.2% of evaluated model-dataset combinations but recovers only part of the lost performance. Model performance is highly consistent between upper- and lower-limb classification and remains strongly correlated with continuous EMG-to-text decoding. Together, these results provide a systematic view of when pretrained time-series models transfer effectively to EMG and how their performance depends on fine-tuning, user variation, and downstream task.

0.19

MyoCodec: A Streaming Neural Codec for Electromyography

eess.SP cs.AI ·2026-09-29 ·Jihwan Lee, Kleanthis Avramidis, Junhyeok Lee, Tiantian Feng, Najim Dehak +1 more
code/data similarity 0.67
Abstract

Neural codecs encode continuous signals into compact sequences of discrete tokens, providing an interface for efficient transmission, storage, and token-based sequence modeling. This paradigm has been widely adopted in modern speech and audio frameworks; however, the biosignal domain still lacks a neural codec designed specifically for low-bitrate streaming and generalization across diverse downstream tasks. We present MyoCodec, a streaming neural codec designed for electromyography (EMG). Inspired by recent neural audio codecs, MyoCodec combines causal Transformers with residual vector quantization to encode continuous EMG signals into different levels of EMG representations spanning from continuous latent features to discrete tokens operating at 50 Hz. Trained on twelve public EMG datasets, MyoCodec achieves favorable performance in both intrinsic codec quality and representative downstream tasks, including typing (emg2qwerty), hand-pose (emg2pose), speech decoding (emg2speech), and speech-to-EMG synthesis (speech2emg). Across these tasks, MyoCodec exhibits strong performance against prior models while providing a compact and causal EMG representation. During streaming inference, it requires compute time of only 0.482 ms for each 20 ms frame, enabling real-time streaming. Also, the discrete token representation provided by MyoCodec has the potential to support integration into language-model based approaches, creating a path toward LLM-based interactive systems, where tokenized EMG representations are directly processed into such language or speech models. Code and model weights are released.

0.32

EFormer: Temporally Aligned Local Correction for Continuous sEMG-Based Hand Pose Tracking

cs.LG cs.HC ·2026-09-30 ·JiaCheng Ge, SiYu Zhang
similarity 0.64
Abstract

Surface electromyography (sEMG) provides a wearable, camera-free signal for continuous hand-motion inference. Mapping muscle activity to joint kinematics remains challenging because the recorded waveforms are indirect measurements, their relationship with motion changes over time, and individual anatomy and sensor placement alter the signal distribution. This paper presents EFormer, a residual feature-correction network built on a frozen tracking backbone. EFormer combines a high-rate event branch, temporally aligned local cross-attention, two causal rotary position embedding (RoPE) temporal layers, and a bounded, dynamically gated residual. EFormer receives 16-channel sEMG sampled at 2 kHz and fuses a 64-channel tracking representation at 25 Hz with a 128-channel event representation at 200 Hz. Cross-attention uses a nominal delay of 100 ms, a 300 ms history parameter, and a 50 ms tolerance; its causal mask restricts each query to events occurring 50-400 ms earlier. The correction scale is 0.15. The evaluated continuation-training configuration contains 585,376 trainable parameters and 5,974,508 frozen parameters. On the test set, EFormer achieves an MAE of 0.1546634 rad, an RMSE of 0.24063 rad, and an R^2 of 0.74801, compared with 0.1745326 rad, 0.2715448 rad, and 0.6791103 for the official tracking baseline. EFormer reduces MAE by 11.38% relative to the baseline. The results show that temporally aligned event-feature correction can reduce continuous hand-pose tracking error.

0.15

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

cs.LG ·2026-10-01 ·Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu +2 more
similarity 0.63
Abstract · The authors are withdrawing this manuscript because the current experimental evaluation and validation are insufficient to adequately suppor…

Electromyography (EMG) signals vary substantially across individuals, body regions, recording sessions, and sensing hardware, limiting the generalization of models for assistive devices and human-computer interaction. Existing time-series foundation models are also computationally expensive for real-time wearable deployment and often fail to capture EMG-specific time-frequency characteristics. We present LiteEMG-FM, an efficient hybrid CNN-Transformer foundation model for practical EMG sensing. Pretrained on 16 diverse upper- and lower-limb EMG datasets, LiteEMG-FM learns representations that generalize across users and datasets. For resource-constrained deployment, we implement a hierarchical wake-up architecture in which a lightweight, always-on 1D-CNN filters rest and non-target activity and activates LiteEMG-FM only for valid gestures. We evaluate full inference offloading, split inference, and full on-device processing, characterizing their trade-offs in latency, power consumption, and memory footprint. Across diverse evaluation settings, LiteEMG-FM outperforms state-of-the-art time-series foundation models and supervised baselines, particularly under zero-calibration cross-participant and data-scarce conditions. These results demonstrate that LiteEMG-FM is an effective, efficient, and deployable foundation model for EMG applications.

0.11

MotorSense: A Video-EMG Dataset of Motoric Representations for Action Understanding

cs.CV cs.RO ·2026-10-30 ·Eadom Dessalene, Michael Maynord, Amir-Hossein Shahidzadeh, Botao He, Yasamin Tabatabaee +4 more
publishedcode/data similarity 0.62
Abstract · NeurIPS 2026. 27 pages, 9 figures, 5 tables. Project page: https://www.cs.umd.edu/~edessale/motorsense/

Computer vision models learn hand action only from its visual consequences, without access to the underlying embodied motor signals. We address this absence with MotorSense, the first large-scale paired egocentric video and surface electromyography (EMG) dataset. MotorSense pairs bimanual EMG bands with egocentric video and yields synchronized video, bimanual EMG and IMU, and audio across 100 hours of unscripted manipulation. EMG offers a powerful scalable alternative to manual annotation: it captures finger movement, hand configuration, and the forces exerted between hand and environment as a dense signal free of occlusion and labeler bias, whereas manual annotation is costly, subjective, and unreliable under occlusion. We use MotorSense to learn sensorimotor alignment, producing an organization of action that is shared across the visual and motoric spaces, through cross-modal pre-training between video and EMG. The resultant vision models are then transferred to downstream tasks that benefit from sensorimotor alignment: in this case, action recognition, 3D hand reconstruction, and 3D contact reconstruction. We further demonstrate a generative application in which EMG motor signals are used to condition a video diffusion model, yielding videos of fine-grained hand manipulation. Across four action-centric computer vision tasks and eight popular video datasets, we demonstrate that sensorimotor alignment provides a stronger foundation for visual representation learning than conventional self-supervised learning methods over video, outperforming every baseline across all tasks and datasets evaluated.

0.28

EVFormer: An Egocentric Vision-EMG Bidirectional Attention Model for Bimanual Hand Pose Estimation

cs.LG cs.HC ·2026-10-03 ·JiaCheng Ge, SiYu Zhang, ShengJie Li, XinTong Yang
similarity 0.62
Abstract

Egocentric bimanual hand pose estimation is important for virtual interaction, wearable control, and rehabilitation, but visual observations are often degraded by self-occlusion, hand-hand contact, and object manipulation. We propose EVFormer, a multimodal framework that combines the current RGB frame with the preceding 200 ms of bilateral wrist surface electromyography (sEMG) to estimate 44 finger and wrist joint angles. EVFormer separately encodes visual spatial features and sEMG temporal features, enables cross-modal information exchange through sequential bidirectional cross-attention, and integrates the two modalities using feature-wise gated fusion. We evaluate EVFormer in a single-participant feasibility study using one synchronized public EgoEMG recording with chronologically separated training, validation, and test splits. On 296 test samples, EVFormer achieves a mean absolute error of 11.482 degrees, compared with 13.228-13.610 degrees for vision-only, sEMG-only, late-fusion, and training-mean baselines. This corresponds to relative error reductions of 13.20% compared with the vision-only model and 14.23% compared with late fusion. EVFormer also achieves the lowest error in four of the five evaluated gesture classes. These results provide preliminary evidence that feature-level interaction between egocentric vision and sEMG can improve bimanual hand pose estimation. Further evaluation across participants, recording sessions, sensor placements, and real-world interaction conditions is required to establish the generalizability of the approach.

0.19