CS Paper Radar

EMA-Based Subspace Tracking for Adaptive Artifact Subspace Reconstruction

Vishnu KN, Cota Navin Gupta

eess.SP ·submitted 2026-09-28 14:07 UTC · v1
code/data

Abstract

Electroencephalogram (EEG) artifact removal remains a critical challenge for real-world brain-computer interface deployment due to non-stationary signal statistics and limited calibration availability. Artifact Subspace Reconstruction (ASR) provides an automated framework for variance-based artifact suppression but relies on a static calibration-derived covariance model, limiting stability under intra-subject drift and increasing sensitivity to parameter mis-specification. This work proposes an adaptive ASR framework based on exponential moving average (EMA) subspace tracking. By integrating short-horizon covariance estimation with slow recursive assimilation, the method establishes dual adaptation timescales that enable responsiveness to evolving EEG structure while preserving stability against transient artifacts. This formulation further promotes smoother operating characteristics across rejection thresholds, reducing sensitivity to hyperparameter selection in continuous deployment settings. Evaluated on 24-channel EEG recordings from 10 subjects with prominent blink artifacts across cognitive states, EMA-ASR achieved substantially stronger artifact attenuation than Original and memory-limited ASR variants (53.1% vs. 24.0% and 26.7% blink reduction), at the cost of increased reconstruction and spectral deviation, whereas the memory-limited variant performed comparably to Original ASR. These findings position EMA-based adaptive tracking as a lightweight, deployment-oriented approach to continuous EEG artifact removal under non-stationary conditions, with an explicit trade-off between suppression strength and signal preservation.

Comment
6 pages, 2 figures, 2 tables. Code: https://github.com/NeuralLabIITGuwahati/EMA-ASR

Closest papers

Nearest neighbours by meaning across the whole index.

Memory-Augmented Online Test-Time Adaptation for EEG Motor Imagery via Perturbation Consistency and Confidence Calibration

cs.LG eess.SP ·2026-10-21 ·Kunkun Zhang, Kehao Wu, Zhitao Chen, Haigen Hu, Qianwei Zhou
top venue similarity 0.61
Abstract · Accepted for publication in IEEE Transactions on Instrumentation and Measurement (TIM), 2026

Recently, electroencephalography (EEG)-based brain--computer interfaces (BCIs) have gained traction as portable neural measurement systems. However, the practical deployment of these instruments is often hindered by nonstationarity and cross-subject distribution shifts, which lead to significant intersubject inconsistency. Existing adaptation methods remain impractical for real-time measurement scenarios, as they typically require offline access to source or aggregated target data. To address these challenges, this article proposes memory-augmented online test-time adaptation (OTTA) with perturbation consistency and confidence calibration (MOPC), a source-free framework designed to enhance the reliability of BCI instrumentation. MOPC enables the measurement system to update its decoding parameters on the fly during the inference stage, facilitating single-pass adaptation without accessing sensitive source data. We introduce random-mask perturbations to enforce prediction consistency against inherent EEG signal noise and acquisition artifacts. Furthermore, a confidence-calibrated reweighting loss is designed to integrate feature-space similarity, effectively mitigating unreliable pseudolabels and class imbalance during continuous signal acquisition. To ensure system stability and prevent the catastrophic forgetting of established neural patterns, a lightweight memory module is incorporated to regularize parameter updates within a tight latency budget. Evaluated on the BCI IV IIb and OpenBMI datasets, MOPC achieves state-of-the-art performance, outperforming prior methods by 2.22~\% and 3.67~\%, respectively, while keeping the per-trial adaptation latency to approximately 40--60 ms. This study provides a robust, recalibration-free solution for real-time EEG decoding, marking a significant advancement in the precision and usability of practical BCI measurement instruments.

0.22

A Proof-of-Concept Study of Weakly Supervised Labeling of Fine-Grained EEG Components for Artifact Attenuation

cs.LG eess.SP ·2026-10-07 ·Lu Wang-Nöth, Hai Huang, Philipp Heiler, Shuqiong Wu, Liyun Zhang +1 more
similarity 0.60
Abstract

Electroencephalography (EEG) is highly susceptible to electromyographic (EMG) artifacts, whose temporal heterogeneity and spatial-spectral overlap with neural activity can leave mixed sources after blind source separation. Existing artifact-removal methods are further limited by scarce reliable component-level ground truth: expert annotations are costly and subjective, while no established method provides realistic simulation-based ground truth for EMG contamination in multichannel scalp EEG. To address these limitations, we propose a framework combining a frequency-aware high-dimensional representation with Multi-Instance Learning. The representation unfolds separated components into frequency-resolved intra-components, creating a space in which mixed neural and muscular activity becomes more separable, while the weakly supervised learning formulation enables artifact-likelihood scores for individual intra-components to be learned from epoch-level labels without finer-grained ground truth. The resulting intra-component classifier supports fine-grained EMG artifact detection and score-guided attenuation. Experiments on held-out subjects show that the framework learns informative intra-component scores and reduces artifact-related spectral deviations most clearly for jaw tension, with moderate effects for raising eyebrows and limited effects for frowning.

0.12

Rethinking EEG Spatial Super-Resolution as Dynamic State Decomposition and Filtering

cs.AI cs.LG ·2026-10-17 ·Hongjun Liu, Leyu Zhou, Chang Ge, Shitong Duan, Chao Yao
similarity 0.60
Abstract

EEG spatial super-resolution aims to recover high-density neural signals from sparse electrode observations. Existing methods have achieved substantial progress through spatial modeling, generative reconstruction, and temporal representation learning. However, the current EEG state contains two different sources of information: predictable evolution inherited from preceding states and newly emerging changes revealed by the current observation. Most approaches typically do not model these two components explicitly. In this work, we formulate streaming EEG spatial super-resolution as a sequential state filtering problem and propose Dynamic State Filtering (DSF). Rather than relying on a single temporal reconstruction pathway, DSF combines a history-aware dynamical branch with an innovation-filtering branch that explicitly decomposes waveform-state estimation into prediction and observation-driven correction. To infer how spatially incomplete innovations should affect missing locations, DSF routes the observed innovations across electrodes through a mask-constrained, topology-aware transition operator and incorporates them through uncertainty-aware state correction. The two complementary estimates are finally fused to reconstruct the dense EEG signal. Experiments on SEED, SEED-IV and BCI2000 demonstrate that DSF improves reconstruction fidelity and downstream utility while maintaining robustness under dynamically changing and unreliable sparse observations.

0.14

Observable And Null Space Electrophysiological Source Imaging with Diffusion Priors

cs.CE ·2026-10-20 ·Zirui Wen, Shihao Yang, Feng Liu
similarity 0.59
Abstract

Electrophysiological source imaging is severely underdetermined because the lead-field matrix has limited rank relative to the source dimension and strongly correlated columns. Scalp EEG measurements constrain only the observable row-space component, leaving a high-dimensional null space unobservable. We propose a two-stage framework coupling posterior diffusion refinement with deterministic null-space completion. A minimum-norm-initialized, singular-coordinate Posterior-DDIM sampler combines a spatiotemporal diffusion prior with direction-dependent measurement reliability to refine the observable component. A frozen ridge predictor and nonlinear temporal residual network then estimate the null component under explicit projection constraints, preserving the refined row estimate and its predicted EEG exactly. All learned components are trained exclusively on simulated cortical activity and its row-null decomposition, without paired EEG-source training data. Across simulations with varying noise levels, the method achieved higher frame-level area under the receiver operating characteristic curve and average precision, together with lower localization error, than conventional and learning-based baselines. Exploratory evaluations on evoked EEG and simultaneous scalp EEG-stereo-EEG recordings showed condition- and event-dependent concordance with cross-modal and intracranial references.

0.11

Identifying Neural Source Dynamics from Unknown Local Interventions

cs.LG ·2026-09-28 ·Ayana Mussabayeva, Jiaqi Sun, Anuar Aimoldin, Olivier Oullier, Kun Zhang
similarity 0.58
Abstract · 11 pages main text, 52 pages total including references and appendices; 3 figures

Electroencephalography (EEG) records mixtures of brain-source activity. Even with a known anatomical forward model, experiments that excite only part of the source-state space leave the dynamics unidentified, and repetition cannot resolve the ambiguity. We show that unknown local mechanism changes can supply the missing information. We consider linear dynamics among fixed anatomical sources with known source-state initialization patterns. Changing one source's update rule for one transition leaves a rank-one, source-specific signature in subsequent EEG: subtracting matched baseline responses isolates it, and the forward model identifies the source and calibrates its response history. Combining these histories with initialization responses recovers source interactions without baseline reachability and without first identifying the intervention coefficients. We establish sufficient recovery conditions, a direct estimator, and a noise-sensitivity bound conditional on correct source labels. Simulated EEG on anatomy derived from magnetic resonance imaging confirms the information gain: with baseline excitation confined to four of twelve source coordinates, eight unknown changes recover all dynamics in 32/32 systems, whereas baseline realization, baseline regression through an invertible forward model, and changes that leave the tested states unexposed all fail, and explicitly constructed alternative dynamics reproduce every baseline mean. Where baseline information suffices, direct reconstruction is also more reliable than a matched-information spectral estimator. Nonlocal changes and forward-model error limit accuracy even when source labels are correct.

0.34

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.58
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

Beyond Reconstruction: A Unified Framework for Trustworthy and Explainable EEG Artifact Removal Evaluation

eess.SP cs.AI ·2026-11-16 ·Phat Lam, Hung Nguyen, Lam Pham, Huy Phan, Dat Tran +3 more
similarity 0.58
Abstract · IEEE journal manuscript under review

Deep-learning methods have achieved strong performance in EEG artifact removal, but evaluation remains dominated by reconstruction metrics such as error, correlation, and signal-to-noise ratio. Although these metrics assess similarity to clean EEG, they do not establish whether models effectively suppress artifacts, preserve neural activity, or provide reliable explanations. To address these limitations, we propose TriX-EEG, a three-level framework for trustworthy and explainable EEG artifact removal. Level 1, Signal Validity (SV), evaluates reconstruction quality and neural band-power preservation. Level 2, Removal Faithfulness (RF), assesses the removed component through artifact error and residual artifact/neural leakage. Level 3, Explanation Reliability (ER), examines model behavior through temporal alignment, causal relevance, and stability. We evaluate TriX-EEG using nine published neural denoisers across three public benchmarks derived from EEGDenoiseNet and the PhysioNet Motion Artifact Contaminated EEG Dataset, covering EOG, EMG, and motion artifacts. Results show that reconstruction metrics alone are insufficient for trustworthy denoiser assessment: RF complements it by revealing whether errors stem from residual artifact or suppressed neural activity, while ER captures distinct aspects of explanation behavior, supporting joint evaluation of three aspects within a unified framework rather than reliance on any single factor. External validation on an independent EEG/EOG dataset and the BCI Competition IV-2a motor-imagery dataset further demonstrates broadly consistent rankings under dataset shift. Higher-ranked denoisers generally preserve more task-relevant information or cause less downstream performance degradation. Overall, TriX-EEG provides a comprehensive basis for EEG denoiser assessment, encouraging models that are not only accurate but also faithful and explainable.

0.27

NOMAD-EEG: Native Omni-Montage Adaptive Diffusion

cs.LG eess.SP ·2026-10-26 ·Abdulkader Helwan, Khadidja Henni, Lina Abou-Abbas
similarity 0.58
Abstract · 37 pages and 7 figures

Purpose. Electroencephalography (EEG) montages, channel counts and recording lengths vary widely, but most EEG foundation models are bound to the channel set and input length they were trained on. We aimed to build a generative EEG foundation model independent of the number, identity and order of electrodes and of the input length. Methods. NOMAD-EEG is a 12.0 M-parameter diffusion model that alternates state-space layers along time, without patches, with attention across electrodes identified only by their 3D scalp position. It was pre-trained on 147 h of unlabelled EEG from a single corpus and evaluated with frozen linear probes on ten datasets with 1 to 64 electrodes against seven foundation models run under one protocol, and on two unseen populations. Results. Despite its small size (12.0 M parameters against 69 M for REVE) and single pre- training corpus, NOMAD-EEG outperformed all seven foundation models on EEGMMIDB mo- tor imagery (balanced accuracy 0.442), Siena seizure detection (macro F1 0.622) and Bonn seizure detection (AUROC 0.999), had the highest accuracy of the seven compared models on TUEP epilepsy diagnosis (0.640) and, after fine-tuning, the highest \k{appa} (0.635) and weighted F1 (0.814) on TUEV event classification. It was the best of five models on P300 detection in autism with an unseen eight-electrode montage (AUROC 0.718). With only 5 of 19 electrodes, its mean AUROC fell only from 0.942 to 0.891. Conclusion. Identifying electrodes by position and modelling time without patches let one small model, pre-trained on one corpus, outperform much larger EEG foundation models on seizure detection, epileptiform event classification, epilepsy diagnosis and motor imagery.

0.14