CS Paper Radar

ErgoAssist: Cognition-Aware Posture Feedback in Wearable Ergonomic Systems

Sarmistha Sarna Gomasta, Bhawana Chhaglani, VP Nguyen, Prashant Shenoy

cs.HC ·submitted 2026-08-31 22:25 UTC · v1

Abstract

Prolonged digital device use has made poor posture and musculoskeletal discomfort pervasive among knowl- edge workers. Existing ergonomic wearables rely solely on posture thresholds, frequently interrupting users during high-focus moments and leading to alert fatigue and abandonment. Yet posture and cognitive load are closely coupled, and most systems remain cognitively unaware. We present ErgoAssist, a head-worn ergonomic assistant that detects poor posture using IMU-based head tracking and estimates task-induced cognitive load using a consumer-grade EEG headband for continuous everyday use. In a controlled lab study, ErgoAssist achieves 81% posture classification and 90.2% task induced cognitive load estimation accuracy under leave-one-subject-out evaluation. In a preliminary real-time deployment, cognition-aware alerting reduces alert frequency by 81%, improves perceived usability by 43%, task performance by 25%, and improves posture correction rate by 38%, delivering fewer but better-timed interventions rather than merely suppressing alerts.

Closest papers

Nearest neighbours by meaning across the whole index.

Tracking Human Daily Cognitive Activity from EEG and Biometric Data

cs.HC ·2026-10-02 ·Alina Gutoreva, Zhaniya Omar
published similarity 0.68
Abstract

Understanding human cognitive activity in everyday life remains challenging due to the dynamic, context-dependent, and multimodal nature of cognition. Laboratory-based studies often fail to capture real-world cognitive processes, while single-modality approaches provide only partial insight into cognitive states. Advances in wearable sensing now enable the collection of heterogeneous data streams for a more comprehensive view of daily cognition. This paper presents a multimodal framework for tracking human cognitive activity using electroencephalography (EEG), wearable physiological signals, behavioral context, and self-reported measures. A preliminary pilot study was conducted with observational data from three participants (N = 3) over 280 annotated 10-minute intervals spanning nine activity domains across two weeks. Results reveal consistent temporal patterns, including a discernible mid-day decrease in motivation and energy at 13:00, followed by afternoon recovery. Work and IADLs yielded the highest flow state rates (51% and 50%), while ADLs produced the lowest (15%). Motivation correlated strongly with arousal (r = 0.78) and attention (r = 0.74), whereas perceived stress showed a weaker negative relationship (r = -0.33). A linear regression model predicting motivation from arousal, attention, energy, and stress achieved R2 = 0.76 (MAE = 9.84, RMSE = 12.85). Lag-based analysis indicates that prior energy levels positively predict subsequent motivation, confirming temporal dependencies in cognitive dynamics. These findings demonstrate the feasibility of multimodal cognitive activity analysis in real-world environments and highlight the importance of integrating physiological and behavioral indicators. The proposed framework provides a foundation for future large-scale multimodal systems and applied intelligent solutions.

0.22

FOCUS: A Lightweight Mamba-2 Model for EEG-Based Cognitive Workload Classification

cs.AI ·2026-10-23 ·Ioannis Kyprakis, Stefanos Gkikas, Chariklia Chatzaki, Zongyi Jiang, Randy Gomez +1 more
similarity 0.58
Abstract

Cognitive workload estimation from physiological signals is increasingly relevant in high-risk environments, where continuous and unobtrusive monitoring can inform adaptive systems and safety interventions. This paper presents FOCUS (Frequency-band Optimized Cognitive-load Ultralight SSM), a compact Mamba-2-based model for EEG-based binary workload classification under constrained data conditions. Rather than learning frequency sensitivity from data, FOCUS encodes preprocessed multi-channel EEG using a fixed FFT decomposition that covers the five canonical EEG bands. The proposed model combines depthwise-separable convolution and a weight-shared encoder-bottleneck Mamba-2 pair, with 0.04 million parameters and 0.11 GFLOPs. Evaluated in a pilot study with 11 participants under leave-one-subject-out cross-validation across three cognitively distinct tasks, FOCUS achieves 74.75% accuracy on the full dataset at 0.08 ms GPU model-forward latency. In the weight-sharing ablation, the shared configuration achieves 4.55 percentage points higher accuracy on the full dataset than the non-shared variant while reducing the SSM parameter budget; however, this difference does not reach statistical significance under a two-sided Wilcoxon signed-rank test ($p=0.083$). Overall, the selected FOCUS configuration provides a favorable trade-off between classification performance and computational cost within this controlled pilot setting.

0.29

A Dry-Contact Ear-EEG System With Continuous Electrode-Skin Impedance Mismatch Monitoring for Motion Artifact Cancellation Using DRL Stimulus

eess.SP eess.SY ·2026-09-02 ·Lohan Atapattu, Sajitha Madugalle, Imasha Nethmal, Erandee Jayathilaka, Avishka Herath +4 more
published similarity 0.58
Abstract · 5 pages, 4 figures, accepted for presentation at IEEE BioCAS 2026

Dry-contact ear-electroencephalography (Ear-EEG) enables wearable neural monitoring. However, motion induced electrode-skin impedance (ESI) mismatches between electrodes can severely degrade signal quality. To the best of our knowledge, this paper presents the first proof-of-concept dry-contact EarEEG system that uses a driven-right-leg (DRL) stimulus for continuous ESI mismatch monitoring, enabling online adaptive motion artifact cancellation. A 1 kHz sinusoidal stimulus is injected through the DRL electrode. The resulting response to the injected carrier is separated from the EEG using bandpass filtering and demodulation, and then used to extract the ESI mismatch information as the reference input for a normalized least-mean-square adaptive filter followed by a Hampel filtering stage. To evaluate artifact suppression and preservation of neural activity, alpha-band EEG activity was analyzed involving four healthy participants performing head nodding, electrode tapping, and jaw clenching. The system achieved artifact power reductions of 6.5, 12.6, and 9.0 dB (77.6%, 92.8%, and 86.4%, respectively) while alpha-band modulation remained clearly observable after processing. This demonstrates the feasibility of DRL-stimulusbased ESI mismatch monitoring for motion artifact cancellation in wearable dry-contact Ear-EEG.

0.38

Understanding Everyday Communication Patterns, Stress, and Productivity in Hybrid Work through Egocentric Wearable Audio Sensing

cs.SD ·2026-10-27 ·Tiantian Feng, Aditya Kommineni, Emily Zhou, Burcin Becerik-Gerber, Gale Lucas +2 more
published similarity 0.55
Abstract · Accepted to SLT 2026

The hybrid work trend in the post-COVID period has transformed how people communicate while at work. However, there is a lack of quantitative understanding of how home and office environments shape communicative behavior and affective well-being. To study this, as a part of a larger study of the role of work environment on stress, we designed an egocentric wearable audio sensing system that captured interpersonal communication across both working locations. The system extracts real-time acoustic features on a wearable audio sensor and performs offline foreground speaker diarization to derive speaking load and activeness features. To improve diarization performance under low-dimensional feature constraints, we apply a teacher-student knowledge distillation framework that transfers knowledge from large-scale speech foundation models into a compact ResNet-based model, achieving consistent improvements in diarization performance over the baseline across three public egocentric speech datasets. In a four-month longitudinal deployment with 16 participants, our system revealed location-dependent differences in work communication patterns. Moreover, the mixed linear model analyses showed that office-based speaking load was significantly associated with higher self-reported stress and lower self-reported productivity, while speaking activeness during home-based work amplified both productivity and affective load in this cohort.

0.38

NeuroPriv: Adversarial Representation Learning for Privacy in Wearable EEG Systems

cs.CR cs.HCcs.LG ·2026-08-31 ·Sarmistha Sarna Gomasta, Bhawana Chhaglani, Prashant Shenoy
similarity 0.55
Abstract

Wearable EEG systems may expose sensitive information beyond their intended health function, creating substantial risks to neuroprivacy. In this work, we show that commonly used EEG features can reveal participant identity and demographic attributes in addition to supporting the intended cognitive task. Wearable EEG is increasingly being explored for cognitive monitoring, neurological assessment, and longitudinal digital-health applications, yet many systems assume that transmitting compact spectral or spatial features instead of raw EEG provides sufficient privacy protection. Using EEGMAT as a motivating case study, we find that compact EEG features achieve a balanced accuracy of 0.788 for cognitive-state classification while enabling gender, age, and subject-identity inference with balanced accuracies of 0.858, 0.789, and 0.692, respectively. We further show that privacy-aware representation learning preserves task performance at 0.781 while reducing these inference accuracies to 0.563, 0.467, and 0.206. These findings motivate purpose-limited representations and explicit privacy auditing in wearable neurohealth systems.

0.42

A Flow-Theoretic Multimodal Control Framework Fusing Mental and Physical Engagement for Upper-Limb Rehabilitation

cs.RO ·2026-10-15 ·Jun Leng, Pengcheng Li, Hanze Wang, Shuxiang Guo, Junlin Jiang
similarity 0.55
Abstract · 10 pages

While Assist-as-Needed (AAN) control aims to maximize user participation in robot-assisted training, existing methods relying solely on physical metrics cannot distinguish muscular inability from mental disengagement, leading to suboptimal interventions. To address this ambiguity, a Flow-theoretic multimodal AAN framework is proposed, fusing EEG-based mental engagement and sEMG-based physical engagement into an adaptive impedance control strategy. A four-quadrant fuzzy decision engine translates these dual physiological metrics into continuous control policies. This enables the upper-limb exoskeleton to inject feedforward assistance during intent-execution mismatch (e.g., motor output attenuation despite mental focus) and escalate guiding stiffness to penalize mental distraction. The framework was validated with healthy participants against a state-of-practice sEMG-only AAN baseline. Kinematically and mechanically, the proposed framework reduced robotic energy expenditure by 71.9\% while maintaining precise trajectory tracking, confirming it elicited greater voluntary human effort. Physiologically, the system increased the time spent in the neuroplasticity zone (Flow State Ratio) from 4.6% to 42.8%. These results validate that decoupling and jointly regulating mental and physical states enhances the selectivity of robotic assistance, mitigating user passivity and sustaining the engagement crucial for motor learning.

0.27

Smart Insole Human Activity Recognition for Continuous Monitoring in Elderly Care

cs.LG ·2026-09-16 ·Edwin Rios, Antony Garcia, Fengpei Yuan, Xinming Huang
similarity 0.54
Abstract

Falls in older adults are often preceded by changes in mobility, balance, and postural transitions. This paper presents a wireless smart insole platform and machine-learning workflow for recognizing sitting, standing, walking, and unstable walking from plantar-pressure and inertial signals. Each insole integrates 16 active pressure-sensing locations and a six-dimensional IMU stream consisting of tri-axial acceleration and angular velocity. Data were collected from 15 healthy adults at 80~Hz and segmented into overlapping windows. Window length and candidate model families were first screened with stratified 10-fold cross-validation; the primary performance estimate was then obtained with participant-independent 5-fold Stratified Group cross-validation, ensuring that all windows from a participant remained in a single fold. Under this protocol, Histogram-Based Gradient Boosting (HGB) achieved macro-F1 scores of 0.954 and 0.959 for the left and right feet, respectively, and 0.980 with bilateral sensing. A compact 1D-CNN evaluated with the same participant-independent folds did not significantly outperform HGB ($p=0.0625$). The results show that low-profile footwear sensing can infer activity state from pressure and IMU measurements for participants unseen during training, establishing a basis for activity monitoring and fall prevention in elderly care.

0.21

Augmenting Human Performance with an XR Agent Learning from Online Behavior and BCI Evidence

cs.AI cs.HC ·2026-08-31 ·Ziheng Li, Xichen He, Haoyan Chen, Charlie Zou, Sheng Bai +8 more
top venue similarity 0.54
Abstract · To appear in ACM UIST 2026. 30 pages, 23 figures

We present OLIVE, a framework for adapting a foundation model to provide real-time assistance in temporally demanding, high-stakes, and dynamic tasks. We show that passive EEG, fused online with behavioral evidence, can meaningfully extend the number of targets users detect and engage beyond their unaided action bandwidth. OLIVE learns from both explicit behavioral signals (the targets the user shoots down in an XR first-person shooter game) and implicit physiological signals (fixation-locked EEG) to provide timely guidance, continuously adapting a frozen vision-language model's inference on which items are task-relevant by jointly estimating per-source reliability without manual labels or offline training. Through three user studies, including two live deployments of an assistive agent driven by OLIVE in XR, we show that OLIVE Pareto-dominates prior test-time adaptation frameworks, achieving the highest convergence rate at comparable convergence speed. Combining implicit physiological and explicit behavioral signals, the OLIVE agent produces the largest and most reliable within-session improvement to a user's ability to detect and engage targets, largely independent of the individual's skill. When the target switches silently, the agent that uses both behavioral and physiological signals reconverges significantly faster than the behavior-only agent (1.27 times faster on average, p = .008), restoring trustworthy guidance at the moment the task changes, precisely when reliable assistance matters most.

0.48