CS Paper Radar

A spinal-inspired spiking neural network for continuous finger-joint kinematics estimation from high-density surface EMG

Cristian David Guerrero-Mendez, Leonardo Abdala Elias

cs.HC ·submitted 2026-10-25 01:34 UTC · v2

Abstract

Decoding simultaneous and proportional finger kinematics from high-density surface electromyography (HD sEMG) remains challenging. Although data-driven methods have shown promising performance for finger movement decoding, their limited physiological interpretability remains a relevant limitation. This study proposes and evaluates a spiking neural network (SNN) that incorporates spinal-inspired structures and mechanisms to predict multi-joint finger kinematics from HD sEMG signals. The spinal-inspired SNN includes a spike-encoding computational model with input-noise variability, a phenomenological representation of Henneman's size principle, and excitation/inhibition (E/I) balance. HD sEMG and kinematic data were collected from 23 healthy participants performing grasping tasks under different elbow and wrist postures. Performance was assessed using six prediction metrics and compared against six baseline machine learning and deep learning methods. The proposed method showed a large and significant ($p<0.05$, rank-biserial correlation $r_{rb}>0.7$) improvement over all baseline methods across all accuracy metrics. Performance improved significantly with increasing spike encoder firing rates up to approximately 83 Hz, and with more regular input spike trains compared with a Poisson-like encoder. In contrast, the E/I balance did not significantly affect the decoding performance of the algorithm. The firing rate and inter-spike interval statistics of the SNN differed significantly across motor tasks. These results demonstrate that incorporating neurophysiological principles into SNNs improves prediction performance while providing additional physiological interpretability for simultaneous and proportional finger-kinematics decoding. This approach represents a promising step toward physiology-informed neural networks, with potential applications in motor rehabilitation.

Comment
32 pages (25 pages of main text and 7 pages of supplementary material), 9 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Neuromotor Hierarchy Network: Physiological Inductive Biases for Robust Generalization in sEMG Decoding

cs.LG ·2026-10-06 ·He Wang, Hongyuan Qi, Zhaoxian Zhang, Jinbin Luo, Linyi He +2 more
similarity 0.68
Abstract · Adjust the authors info

Surface electromyography (sEMG) provides a wearable, noninvasive interface to neuromuscular activity for movement decoding and human-computer interaction. Population-scale decoding remains difficult because the relationship between sEMG and neuromuscular activity varies across users and sessions, while task-relevant dynamics span channels and multiple timescales. Learning waveform-to-output mappings from task labels leaves the distinction between recording variability and coordinated motor activity implicit. We introduce the Neuromotor Hierarchy Network (NHN), which learns a compact latent neuromotor state from task supervision to represent task-relevant neuromuscular coordination. NHN constructs this latent state through a hierarchy inspired by neuromotor organization. It adapts recording statistics while preserving relative intensity. Its spatiotemporal encoder uses parameter-efficient channel interactions and modulates features with multi-timescale history. The resulting features yield candidate activations of learned motor primitives, which are temporally integrated and continuously weighted to form the state. Theoretical analysis characterizes the efficiency, temporal behavior, and optimization of NHN's core mechanisms. We evaluate the architecture for both continuous hand-pose estimation on emg2pose and touch-typing recognition on emg2qwerty. On emg2pose, NHN reduces user-averaged angular error by 0.52% to 2.84% across all three generalization splits in both Regression and Tracking relative to Hadidi et al.'s best task-specific variants, using 48.42% to 48.51% fewer parameters. On emg2qwerty, NHN reduces beam-search character error rate by 19.40% zero-shot and 30.42% after fine-tuning relative to SplashNet-Upscale, using 65.86% fewer parameters. Physiology-guided inference of a latent neuromotor state supports parameter-efficient sEMG decoding.

0.18

Deep Neural Networks for Learning Intent from sEMG Signals to Support Hardware Devices for Post-Stroke Neurorehabilitation

cs.LG ·2026-09-09 ·Zakariyya Brewster, Divy Wadhwani, Emily Yan, Aidan Wang, Karma Namgyal +3 more
hot direction similarity 0.67
Abstract

Finger-specific motor intent is a clinically meaningful control signal for post-stroke neurorehabilitation, where residual muscle activity may remain measurable despite weak or incomplete movement. We study five-finger multilabel intent decoding from impaired-arm high-density surface electromyography (sEMG) in PhysioMio, a bilateral longitudinal dataset collected from stroke patients. A common processing protocol aligns movement labels, applies 20--450 Hz Butterworth filtering and Symlet-4 wavelet denoising, segments overlapping 200 ms windows, and extracts twelve time- and frequency-domain descriptors per channel. Direct LSTM, CNN, and GNN baselines reveal complementary behavior: the LSTM attains the highest subset accuracy (0.545), whereas the GNN attains the highest macro F1 (0.706) and macro AUPRC (0.776). Architecture search then identifies CNN-Large as the strongest single-split CNN, with 0.593 subset accuracy and 0.714 macro F1, while CNN-Micro provides a compact architecture for embedded inference. To match a four-sensor hardware design, we retrain CNN-Micro using channels associated with ECRB, ECRL, FDS, and FDP and exclude the ground electrode from model input. Across five seeds, cross-channel knowledge distillation improves the four-channel student over direct training, reaching $0.5219 \pm 0.0114$ subset accuracy, $0.7612 \pm 0.0038$ finger accuracy, and $0.6095 \pm 0.0058$ macro F1. The selected 123K-parameter model accepts nine windows of 48 features and has been exported to ONNX. These results establish a reproducible software path from post-stroke sEMG to compact five-finger intent prediction for subsequent hardware-in-the-loop evaluation.

0.26

ST-Topo GAN: A Motor EEG-to-EMG Decoding Model Matched to Wrist Movement Complexity

eess.SY cs.LG ·2026-08-23 ·Ye Sun, Mingxuan Qu, Jing Wang, Dezhong Yao, Gang Liu
similarity 0.61
Abstract · 11 pages, 9 figures

The wrist plays a critical role in upper-limb function by enabling precise hand positioning, force regulation, and object manipulation. Continuous brain--muscle interfaces (BMIs) offer a promising approach for motor restoration by decoding neural activity into muscle activation signals. However, existing EEG-to-EMG models have mainly been developed for tasks with relatively stable muscle synergies and may be less effective for the heterogeneous and weakly coupled neuromuscular organisation involved in wrist movements. This paper proposes ST-Topo GAN, a Spatial--Temporal Topological Generative Adversarial Network for continuous EEG-to-EMG decoding of wrist movements. The framework integrates multi-band EEG representation, sensorimotor cortical topology modelling, and conditional adversarial learning to reconstruct multi-channel iEMG activation. The model was evaluated through cross-task comparison, wrist EEG-to-iEMG decoding, and ablation experiments. Compared with the WAY-EEG-GAL grasp-and-lift dataset, the wrist dataset exhibited lower inter-muscle activation similarity and greater decoding difficulty for conventional models. ST-Topo GAN achieved an average PCC of 0.4436 on the wrist dataset, outperforming all evaluated baselines, while the ablation study confirmed the contribution of its key components. These results support the effectiveness of ST-Topo GAN for continuous wrist EEG-to-iEMG decoding.

0.25

DoF-Query Transformer for Adaptive Fusion of Egocentric Vision and Forearm HD-sEMG in Continuous Hand Kinematics

cs.CV cs.HCcs.LG ·2026-11-15 ·Jiahang Liu, Wenbo Zhang, Junsong Wang, Zhenzhi Ying, Siqi Hou +2 more
similarity 0.61
Abstract

Continuous and accurate estimation of human hand kinematics is important not only for intuitive human-machine interaction, but also for capturing fine-grained human manipulation demonstrations that can provide action supervision for embodied-intelligence datasets and dexterous robot learning. However, individual sensing modalities may be insufficient for reliable estimation under varying operating conditions. We present a finger-unencumbered multimodal framework for continuous regression of 20 hand joint angles from egocentric RGB images and 128-channel forearm high-density surface electromyography (HD-sEMG). The framework combines a Vision Transformer-based visual encoder, a Transformer-based EMG encoder, and a degree of freedom (DoF) query Transformer fusion decoder. To account for the varying informativeness of visual and EMG cues across joint DoFs and input conditions, the decoder assigns a separate learnable query to each DoF, enabling DoF-specific and context-adaptive fusion of the two modalities. The framework was evaluated on synchronized multimodal data from 10 participants. Averaged across participants, the proposed fusion model achieved a mean coefficient of determination ($R^2$) of $0.88$ and a mean absolute error (MAE) of $2.80^\circ$, compared with $0.82$ and $3.21^\circ$ for the vision-only model and $0.68$ and $5.13^\circ$ for the EMG-only model. It also outperformed the evaluated representative unimodal baselines and alternative fusion designs. DoF-wise analyses showed larger fusion gains for visually ambiguous joints and viewing conditions, while synthetic visual occlusion demonstrated greater robustness than vision-only estimation. These results highlight the complementary value of egocentric vision and forearm HD-sEMG for capturing fine-grained human hand kinematics, with potential applications in human demonstration acquisition and dexterous robot learning.

0.05

Feature extraction for LSTM-based finger-joint angle estimation from sEMG

cs.LG ·2026-11-02 ·Gerda de Jager, Marelie H Davel, Ian Thomson
similarity 0.61
Abstract · 20 pages, 8 figures

Continuous estimation of finger-joint angles from surface electromyography (sEMG) is a promising approach for controlling dexterous myoelectric prostheses. Deep time series models have been applied successfully in this context, typically relying on feature extraction rather than raw signals, given limited subject-specific data. Various time-domain and frequency-domain features can be used, extracted for a given window and step size. This study systematically investigates these three design choices for Long Short-Term Memory (LSTM) regression on the Ninapro DB2 dataset. Window sizes from 300 to 1200 ms and step sizes from 10 to 100 ms were evaluated in combination with six time- and frequency-domain features. Models were evaluated using regression performance metrics, inference time, and memory footprint to assess feasibility on embedded microcontroller hardware suitable for a prosthetic device. A 300 ms window with a 100 ms step, paired with either the Mean Absolute Value (MAV) or Root Mean Squared (RMS) feature, yielded the best performance (test PCC of 0.779 +/- 0.080 / 0.779 +/- 0.085). Window size, step size, and feature choice were found to interact non-trivially: jointly tuning them can improve both accuracy and computational feasibility for real-time, embedded myoelectric control.

0.28

Data-Centric Neuromotor Interfaces for Portable Human-Machine Interaction

cs.RO ·2026-08-31 ·Jiaxuan Li, Di Wu, Jianhua Liu, Yuxin Zhao, Jinnuo Li +5 more
publishedbenchmark similarity 0.61
Abstract

Dexterous human-machine interaction requires intuitive and expressive interfaces that can be efficiently deployed on constrained edge devices. Flexible material-based neuromotor interfaces hold considerable promise, as they decode human movement intention into natural control. Although emerging flexible electronic skins enable wearable high-fidelity data acquisition, practical deployment inevitably involves trade-offs between computational resources and portability. We present a data-centric paradigm where physiological features yield fundamental separability, providing sufficient discriminative cues for recognition. A wireless, high-bandwidth system developed for collecting various electrophysiological signals, when integrated with muscle-specific electrodes, forms a surface electromyography-based interface. Exploiting highly separable data, a 2,210-parameter model achieves 94.36% accuracy across 34 gestures and can be rapidly deployed on edge devices, establishing a new thousand-parameter benchmark for dexterous decoding. The underlying data-algorithm interactions in the data-centric paradigm are further clarified, demonstrating its feasibility in real-world scenarios. This study provides a principled and validated pathway for practical deployment of reliable neuromotor interfaces.

0.22

EMG Tokenization Preserves Movement Information at a Fraction of the Bitrate

eess.SP cs.HCcs.LG ·2026-10-23 ·Raul C. Sîmpetru, Amin Olamazadeh, Devon Rohlf, Vlad Cnejevici, Alessandro Del Vecchio
benchmark similarity 0.60
Abstract · 11 pages, 7 figures; 12-page supplement included. Supplementary Data 1-9 (CSV) are provided as ancillary files

Wireless electromyography (EMG) interfaces must balance electrode coverage against transmission bandwidth. Here, we show that compact EMG tokens substantially reduce payload while retaining information for three-dimensional hand-pose decoding. We evaluate two causal tokenizers fitted without pose labels: an encoder pretrained to reconstruct EMG spectra and one based on SPAR, an engineered spectral-spatial representation of neighbouring electrodes. In personalized, within-session experiments with 320-channel EMG from nine participants, we compare tokenized and continuous features using matched decoder architectures and training procedures. Averaged across decoders, tokenization changed mean error by +0.01 mm for SPAR (95% confidence interval: -0.12 to 0.14) and +0.45 mm for the learned representation (0.10 to 0.82). Both increases met a 1 mm non-inferiority criterion. Stored token arrays reduced payloads 41-fold relative to raw EMG and 36-fold relative to continuous SPAR features. On sampled windows of the public emg2pose benchmark's test partition, absolute differences in mean error between learned tokens and continuous features were below 0.05 mm across 176 participants and in the subset of 20 participants unseen during training. Electrode coverage, calibration, and unseen recordings affected SPAR decoding more than quantization did. In a computational benchmark, optimized SPAR generated tokens for 63 channels within 20 ms on a Cortex-M55 microcontroller. These findings support tokenization as a compact interface between wearable sensing and movement decoding, allowing decoders to be updated while the wearable encoder and transmitted representation remain fixed.

0.29

MyoFlow: Anchor-Tied Rectified Flow for HD-sEMG Gesture Recognition Across Sessions and Subjects

cs.LG ·2026-09-15 ·Chenhao Wu, Dingjie Peng, Zhihe Zhang, Satoshi Funabashi, Satoshi Konishi +4 more
hot direction similarity 0.60
Abstract

High-density surface electromyography (HD-sEMG) gesture recognition supports prosthetic control, assistive robotics, and rehabilitation, but electrode re-donning and physiological variability cause distribution shifts that degrade accuracy across sessions and subjects. Generative HD-sEMG models primarily synthesize signals for augmentation; although diffusion models enhance representation learning, prediction still relies on a separate classifier. To tie learned dynamics to the decision rule, we propose MyoFlow, the first discriminative flow-matching framework for HD-sEMG recognition across sessions and subjects. It recasts classification as anchor-tied transport: a domain-conditioned rectified flow moves encoded windows toward gesture anchors that serve as transport targets and define the nearest-anchor decision geometry, enabling zero-shot recognition without an independent head. On the Hyser dataset, MyoFlow improves mean cross-session and cross-subject accuracy over the strongest diffusion-based baseline by 4.24% and 6.37%, respectively, and achieves 91.71% mean zero-shot accuracy and 97.39% mean few-shot accuracy across multiple days on the CEMHSEY dataset.

0.32