CS Paper Radar

Unlocking with the Heart: Investigating User Perceptions of ECG-Based Biometric Authentication

Farnaz Farid, Linet Momposhi, Tamara Watson, Alana Maurushat, Abubakar Bello, Farhad Ahamed

cs.HC cs.CRcs.CYcs.ETeess.SY ·submitted 2026-10-29 01:39 UTC · v1
survey

Abstract

Password-based authentication remains challenging for many users, especially for those who face usability and accessibility issues. The burden of maintaining security can cause user fatigue, frustration and non-engagement. To address these issues, we conducted a pilot study to assess ECG-based biometric authentication as a passwordless alternative and to gather adult participants' perspectives on this approach. The research consisted of a survey study, an authentication prototype and a follow-up usability experience questionnaire. Our approach combined an online survey of 337 adults examining authentication practices and perceptions, with a separate usability evaluation in which 49 participants interacted with a simulated ECG-authentication and password interface in a health-care application prototype, then completed a post-test usability test questionnaire. The survey examined how adults across age groups use and perceive various authentication techniques, their experiences with biometrics, their views on security and convenience, and their willingness to adopt ECG authentication. In parallel, the usability prototype and questionnaire captured participants' responses after hands-on interaction with an ECG authentication prototype.

Comment
28

Closest papers

Nearest neighbours by meaning across the whole index.

Heart Signal (ECG) as Vibration Signature for Human Authentication Using TinyML

cs.CR cs.AR ·2026-10-17 ·Yogeswar Reddy Thota, Student Member, IEEE, Hanan Alsmadi, Student Member +4 more
similarity 0.56
Abstract

Ensuring data security in the era of Artificial Intelligence (AI) and deepfake technology requires robust biometric systems. Conventional methods such as facial recognition, iris scans, fingerprints, and voice recognition are increasingly vulnerable to spoofing and provide only one-time authentication at login. This study introduces an Electrocardiogram (ECG) based authentication framework, compared with Photoplethysmography (PPG), leveraging Tiny Machine Learning (TinyML) for deployment on resource-constrained microcontroller units (MCUs). The proposed method enables continuous authentication, offering ongoing verification throughout device usage, which conventional biometrics cannot achieve. It also serves as a password-free solution, reducing risks of credential loss, theft, or reuse. However, ECG signals vary with physical activity, health conditions, age, and emotional states, requiring robust signal processing and learning algorithms. To address this, efficient TinyML models were designed to mitigate recognition errors from noisy real-time data. Experiments used single-lead ECG signals (Lead I) from UofTDB, MIT-BIH Arrhythmia, MIT-BIH Noise Stress Test, and PTB databases. Spectrograms and spectral features were extracted to train Deep Neural Network (DNN), 1D CNN, and 2D CNN models within the Edge Impulse platform, achieving 98% accuracy. The trained model was converted into TinyML format and deployed on an Espressif ESP-EYE (ESP32, 240 MHz). Support Vector Machine (SVM) models were also applied for benchmarking. By analyzing the number of heartbeats required for reliable recognition, the results show that averaging multiple signals improves tolerance to noise and enhances accuracy. Overall, ECG-based authentication demonstrates strong potential as a secure, real-time, and continuously verifiable method for personal identification on wearable and edge devices.

0.20

Context or Digits? Balancing Memorability and Efficiency in Virtual Reality Authentication

cs.CR cs.HC ·2026-08-30 ·Yuxuan Huang, Qiao Jin, Tongyu Nie, Victoria Interrante, Evan Suma Rosenberg
publishedunusual similarity 0.55
Abstract · This paper has been conditionally accepted to VRST 2026

We present Adaptive Direction-Based Authentication (ADBA), a knowledge-based authentication method for Virtual Reality that decouples users' needs temporally by enforcing password creation based on virtual environment context while supporting both context- and digit-based entries during authentication. This design prioritizes memorability for new passwords and offers both efficient and memorable options to support users' evolving needs. We conducted a remote longitudinal study with 66 participants comparing ADBA against 6-digit PINs over 2-3 weeks. The results demonstrated that ADBA achieved superior memorability and lower perceived task load. Interestingly, no participant chose to enter via digits in the study, yet they still perceived ADBA to be highly efficiency despite longer objective entry times. ADBA also provided security benefits through randomly-generated digit representations, though some degree of password homogeneity was observed in specific virtual environments. Our findings suggest that ADBA offers solid advantages to the traditional PINs, and successfully addresses the tradeoffs between efficiency, memorability, and security under the usage scenarios considered in the study.

0.37

Finger-to-Ear ECG: Systematic Evaluation of an Earbud-Based Cardiac Monitoring Approach

cs.HC ·2026-09-21 ·Philipp Lepold, Paula Breitling, Jonas Hummel, Tobias Röddiger, Michael Beigl
published similarity 0.53
Abstract

Ear-ECG enables unobtrusive cardiac monitoring, but existing approaches often struggle with low signal amplitudes and limited morphology preservation. We evaluate a finger-to-ear ECG paradigm that combines an in-ear electrode with a rear housing finger-contact electrode in a speaker-equipped earbud. A study with 30 participants investigated four finger-to-ear electrode geometries against chest-reference ECG and additionally assessed robustness under music playback, talking, and walking disturbances. Left-finger configurations achieved R peak detection F1-scores >99% with high agreement of key ECG morphology features. In contrast, right finger configurations as well as walking led to severe signal degradation. The results reveal a trade-off: while cross-body setups provided the highest signal fidelity, users preferred same-side contacts for comfort reasons. This establishes finger-to-ear ECG as a robust, morphology-aware paradigm for opportunistic sensing in earables.

0.38

Conversational Interaction for LLM-Based Clinical Text-to-SQL: A User Study with Healthcare Professionals

cs.AI cs.HC ·2026-10-31 ·Jun-Min Lee, Suyoung Yoo, Gyubok Lee, Edward Choi, Meong Hi Son
benchmark similarity 0.53
Abstract

Conversational text-to-SQL interfaces could give healthcare professionals natural-language access to electronic health record (EHR) data, but evidence for their real-world usability remains limited: prior evaluations have relied largely on curated benchmarks with fully specified questions or on simulated users. We report a user study in which 14 physicians who regularly work with EHR data used both a single-turn and a conversational multi-turn text-to-SQL interface over the MIMIC-IV database in a within-subjects design; dialogue analyses additionally drew on interaction logs from 21 healthcare professionals across the main study and two pilot studies. The conversational interface was consistently favored: mean System Usability Scale scores rose from 68.2, near the industry average, to 85.9 (p<0.001), with significant advantages across technology-acceptance constructs including performance expectancy, effort expectancy, self-efficacy, and behavioral intention. In post-study forced-choice comparisons, 93% of participants reported greater overall satisfaction with the conversational interface, 86% preferred it for real-world adoption, and 71% trusted its results more; no participant preferred or trusted the single-turn interface more. Turn-level analysis of 425 logged user turns showed that freely composed queries triggered clarification requests in 24.8% of cases versus 1.8% for predefined, fully specified questions, and 64.3% of clarification episodes stemmed from EHR- or clinical-domain knowledge. Conversational interaction is a practical prerequisite, rather than a convenience, for natural-language EHR access. The frequent need for clarification in realistic clinical queries further underscores the importance of conversational interfaces, while benchmark-style evaluation can substantially underrepresent the ambiguity of real clinical use.

0.32

User Experience in Human-Machine Interaction: Insights from Field Studies in Autonomous Mobility

cs.HC ·2026-08-31 ·Helen Schneider, Svetlana Pavlitska, J. Marius Zöllner
published similarity 0.50
Abstract · Accepted for publication at ABAW Workshop at ECCV2026

Autonomous vehicles (AVs) promise safer, cleaner, and more inclusive mobility, yet large-scale adoption is hindered by user acceptance rather than by technical challenges. Prior studies on acceptance and user experience largely rely on surveys, simulators or Wizard-of-Oz setups, often over-representing technologically enthusiastic participants and focusing on drivers instead of passengers. We address this gap with real-world field studies with AVs in real traffic, totaling 144 participants. Using multi-modal sensing, we evaluated EGG, heartbeat, breathing, camera and voice signals for affect inference in combination with vehicle data. Our results show that breathing, camera and voice measurements are reliable and pratical in naturalistic passenger contexts. We further contribute a validated study protocol, a self-assessment app for real-time assessment during human-machine interaction, and a tailored questionnaire to capture participant attitudes towards AVs. By grounding UX evaluation in real-world contexts, this work lays a foundation for user-centered design of autonomous mobility systems and robotics in general. Our work bridges the gap between affective computing and technical implementation of autonomous vehicles.

0.14

WiP: Characterizing and Defending Against Mobile-Agent-Driven MFA Automation

cs.NI ·2026-09-02 ·Yimeng Liu, Hua Huang
top venue similarity 0.50
Abstract

Mobile agents automate smartphone tasks by interpreting interfaces, interacting with apps, and coordinating cross-app workflows. This capability challenges the human-mediated separation assumed by passcode-based MFA, creating factor collapse: valid authentication factors are combined within one autonomous environment. Our modular pipeline com- pletes all 10 authorized MFA workflows, compared with 3/10 and 6/10 for two single-agent baselines. We also de- velop a motion-based Android risk signal that distinguishes human- from agent-driven logins with 98.4% table-top and 92.6% hand-held accuracy across 116 pilot sessions. These results demonstrate factor collapse and motivate physical- interaction sensing as complementary evidence of user pres- ence.

0.42

"I'm trying not to get hacked:" How Adults with Intellectual and Developmental Disabilities Navigate Security and Privacy Notifications

cs.HC ·2026-10-01 ·Hailey L. Johnson, Julia Nonnenkamp, Bilge Mutlu, Rahul Chatterjee
top venue similarity 0.49
Abstract · 27 pages, 8 figures, 8 tables. Accepted to The 28th International ACM SIGACCESS Conference on Computers and Accessibility (ASSETS '26), Octo…

Security and privacy notifications, such as login alerts, spam email warnings, and cookie consent requests, play a critical role in shaping users' responses to digital risks. Yet most notifications overlook cognitive accessibility, limiting their effectiveness for people with intellectual and developmental disabilities (IDD). We investigate how adults with IDD perceive and respond to common security and privacy notifications across mobile and web applications. Through a formative user study with seven adults with IDD, we identify three factors shaping understanding and decision-making: (1) interpretation is influenced by task and interface context; (2) unfamiliar terms, both technical and non-technical, are grounded in everyday concepts; and (3) uncertainty about outcomes leads to hesitation, avoidance, diagnostic exploration, or support-seeking. These findings lead to three design implications: (1) address context-dependent language misunderstandings beyond jargon simplification; (2) make action-outcome connections transparent; and (3) enable interdependent decision-making. Together, these insights aim to inform the design of more cognitively accessible security and privacy notifications that better support safe and supported user action.

0.43

Calmables: Demonstrating Closed-Loop Infrared Earables for Thermal Biofeedback and Relaxation Support

cs.HC ·2026-09-16 ·Valeria Zitz, Michael Küttner, Jonas Hummel, Taku Inoue, Tobias Rödiger +1 more
published similarity 0.48
Abstract

We present Calmables, a walk-up demo of a closed-loop infrared earable that uses smart-ring heart rate to create subtle, ear-localized warming cues. Building on work on thermal comfort and in-ear infrared stimulation, Calmables explores warmth at the ear as a biosignal-adaptive cue for brief recovery moments following acute activation. A smartphone first establishes an individual resting baseline and derives a personalized heart-rate threshold, while the earable controller independently enforces an over-temperature cut-off and communication fail-safes. During the guided demo flow, attendees complete a brief rapid-breathing activation phase until their heart rate reaches the personalized threshold. This triggers an ear-localized warming cue followed by a short relaxation phase, while physiological changes are displayed on a live dashboard. Attendees can also manually explore different infrared stimulation intensities. To contextualize the demo, we report preliminary placebo-controlled UX ratings from 18 participants: participants rated the active prototype higher on perceived relaxation and perceived recovery support than an identical-looking placebo. Together, the demo illustrates how infrared earables can make physiological feedback tangible through subtle, biosignal-adaptive thermal cues.

0.59