Abstract

Ensuring data security in the era of Artificial Intelligence (AI) and deepfake technology requires robust biometric systems. Conventional methods such as facial recognition, iris scans, fingerprints, and voice recognition are increasingly vulnerable to spoofing and provide only one-time authentication at login. This study introduces an Electrocardiogram (ECG) based authentication framework, compared with Photoplethysmography (PPG), leveraging Tiny Machine Learning (TinyML) for deployment on resource-constrained microcontroller units (MCUs). The proposed method enables continuous authentication, offering ongoing verification throughout device usage, which conventional biometrics cannot achieve. It also serves as a password-free solution, reducing risks of credential loss, theft, or reuse. However, ECG signals vary with physical activity, health conditions, age, and emotional states, requiring robust signal processing and learning algorithms. To address this, efficient TinyML models were designed to mitigate recognition errors from noisy real-time data. Experiments used single-lead ECG signals (Lead I) from UofTDB, MIT-BIH Arrhythmia, MIT-BIH Noise Stress Test, and PTB databases. Spectrograms and spectral features were extracted to train Deep Neural Network (DNN), 1D CNN, and 2D CNN models within the Edge Impulse platform, achieving 98% accuracy. The trained model was converted into TinyML format and deployed on an Espressif ESP-EYE (ESP32, 240 MHz). Support Vector Machine (SVM) models were also applied for benchmarking. By analyzing the number of heartbeats required for reliable recognition, the results show that averaging multiple signals improves tolerance to noise and enhances accuracy. Overall, ECG-based authentication demonstrates strong potential as a secure, real-time, and continuously verifiable method for personal identification on wearable and edge devices.

Closest papers

Nearest neighbours by meaning across the whole index.

Few-Shot Prototype Head Adaptation for On-Device ECG Personalization on PSoC~6

cs.LG cs.AI ·2026-10-05 ·Guilherme Silva, Pedro Silva, Gladston Moreira, Eduardo Luz
published similarity 0.66
Abstract

Wearable and bedside electrocardiogram (ECG) monitors must adapt to patient-specific morphology to maintain arrhythmia detection accuracy across users, yet personalization is typically performed offline and cannot account for individual physiology, electrode placement, or recording drift. On-device adaptation by backpropagation is expensive for microcontroller-class medical devices because it requires an optimizer state, repeated backward passes through convolutional layers, and labeled arrhythmic beats that may not be available at deployment time. This letter proposes prototype-only head adaptation as a compact personalization primitive for TinyML ECG systems. A one-dimensional convolutional neural network (1-D CNN; 1,314 parameters and 72.6k multiply-accumulate operations per beat) is trained offline on the MIT-BIH Arrhythmia Database under an inter-patient protocol, frozen as a feature extractor, and exported to a PSoC 6 microcontroller. Patient-specific adaptation then reduces to computing closed-form class means in a 32-dimensional embedding space, requiring no convolutional backward pass, no iterative optimization, and only one forward pass per support beat. Prototype adaptation improves inter-patient macro-F1 from 0.635/0.639/0.646 to 0.731/0.771/0.797 at 1/5/10-shot, outperforming linear stochastic-gradient-descent (SGD) head fine-tuning at every shot count for the target tiny backbone. On-device replay over 18 one-shot episodes on a PSoC 6 Cortex-M4F matches the host macro-F1 for the prototype head (0.798), with 11.39 ms per beat, 5.2 KB flash, and 22.2 KB SRAM. A restricted variant that updates only the normal-class prototype from passively buffered sinus beats yields a consistent +0.05 macro-F1 gain, reducing the annotation burden during initial

0.37

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.63
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

ECGWmark: Deep Watermarking of Electrocardiogram Signals With Error-Correcting Codes

eess.SP cs.CRcs.CV ·2026-10-09 ·Kuan-Yu Chen, Kuan-Chen Wang, Yu Tsao, Jian-Jiun Ding
similarity 0.59
Abstract · 10 pages, 3 figures, 4 tables

Wearable electrocardiogram (ECG) recordings pass through multiple networks and systems before automated interpretation, making patient metadata vulnerable to loss. Digital watermarking embeds this metadata directly into the signal. However, conventional ECG watermarking methods fail under temporal desynchronization, and waveform similarity does not guarantee downstream diagnostic preservation. This article presents ECGWmark, a deep watermarking framework for single-lead ECG. A fully convolutional generator embeds the payload without signal quantization, a detector decodes the message frame by frame and verifies watermark presence, and a frozen arrhythmia classifier penalizes changes that would alter diagnostic predictions. To bridge the gap between bit accuracy and whole-message recovery, payloads are protected by extended Hamming codes, validation-selected interleaving, and soft-decision decoding. On the MIT-BIH Arrhythmia Database, ECGWmark maintains over 90\% bit accuracy under time shifts of 10 to 50 samples, where transform baselines fall to chance level. With the coding layer, the protected 16-bit payload achieves 99.86\% exact recovery on clean segments and sustains over 90\% recovery under time shifts, 10\% sample deletion, and 10\% packet loss. Inter-patient evaluation confirms improved ventricular-beat sensitivity with preserved macro-F1. Requiring only 0.56 million parameters and about 15~ms per segment on a desktop CPU, ECGWmark highlights the need to assess physiological watermarking through whole-message recovery and diagnostic consistency.

0.18

From ECG Signals to Representative-Morphology Heatmaps for Biometric Recognition

cs.CV eess.SP ·2026-09-23 ·Athanasios Angelakis, Marta Gomez-Barrero
similarity 0.57
Abstract · 31 pages, 7 figures, 14 tables

Electrocardiography (ECG) contains subject-specific morphology that supports biometric recognition, yet image-based performance depends on how the waveform is rendered. We introduce representative-morphology heatmaps, a deterministic ECG-to-image representation adapted from ECGXtractor. Within each block of ten aligned beats, the five beats closest to the block mean are averaged into a 400 by L matrix and rendered either as a conventional trace or as a dense cardiac-time-by-lead heatmap. Since both representations contain identical physiological samples, their comparison isolates the effect of rendering. We evaluate verification and closed-set identification on PTB, ECG-ID, and MIMIC-IV-ECG-DEMO. Five compact models, including ZACH-ViT, are trained from scratch, while six ImageNet-pretrained CNN and transformer backbones assess model scale and visual transfer. Heatmaps improve both FNMR operating points and both identification ranks in all 15 compact model-dataset comparisons, while EER improves in 14. Across the matched experiments, EER decreases by 9.59 percentage points and Rank-1 increases by 24.69 points on average. ConvNeXt-Tiny reaches 2.43% EER on PTB and 5.79% on ECG-ID, whereas DeiT-Base reaches 14.92% on MIMIC-DEMO. ImageNet initialization clearly benefits the two multilead datasets but has a mixed effect on ECG-ID, and performance does not increase monotonically with model size. The best heatmap systems approach the strongest signal-domain EER on PTB and ECG-ID, while DeiT-Base provides the strongest evaluated performance on MIMIC-DEMO. Lead-channel ablation further shows that useful channel combinations depend on the cohort and biometric task. Overall, representative-morphology heatmaps provide an effective image representation for ECG verification and identification.

0.21

Privacy-Preserving ECG-HRV Emotion Classification for Mood Swing Detection using Federated Learning on Constrained Edge Devices

cs.LG cs.AI ·2026-11-01 ·Chidike Vincent, Muhammad Aslam Jarwar, Najam Ul Hasan, Laurence Hirsch, Jonathan Zasada-James +1 more
similarity 0.57
Abstract

This paper presents a privacy-preserving mood monitoring framework that classifies emotional states from ECG-derived heart rate variability (HRV) features. The framework is evaluated on three public datasets comprising 74 participants and further validated using a wearable device in a pilot study. Leave-One-Participant-Out cross-validation (LOPO-CV) is used to assess generalization to unseen individuals. A series of experiments investigates the impact of temporal windowing, HRV feature selection, and class balancing on both four-class valence-arousal and binary valence classification. Results show that class balancing substantially improves minority-class recall, while Logistic Regression consistently outperforms five alternative classifiers and achieves competitive performance against HRV-based baselines. Pilot validation using a Polar H10 wearable achieves 75% binary valence accuracy on an unseen individual without calibration, demonstrating the feasibility of real-world deployment. To preserve privacy, the framework is also implemented using federated learning on a six-node Raspberry Pi cluster. Federated Logistic Regression achieves performance comparable to centralized training without sharing raw physiological data. These results demonstrate the potential of interpretable and privacy-preserving mood monitoring for continuous mental health assessment in clinical and community settings.

0.25

Interpretable Stress Detection from ECG Signals Using Motif-Based Anomaly Analysis

eess.SP cs.LG ·2026-08-27 ·Zhanna Balyan, Sachin Kumar
similarity 0.56
Abstract

Stress detection using physiological signals has gained significant attention due to its impact on both physical and mental health. While existing approaches based on machine learning and deep learning achieve strong predictive performance, they often rely on black-box models and fail to capture individual variability in physiological responses. In this work, we propose an interpretable and personalized framework for stress detection using electrocardiogram (ECG) signals based on motif discovery and Matrix Profile analysis. Instead of training a classifier, the method learns subject-specific baseline cardiac behavior by extracting recurring heartbeat patterns (motifs) from ECG signals. Stress is then detected as a deviation from these baseline patterns using a distance-based anomaly score. Experiments are conducted on the WESAD dataset using a carefully designed train-validation-test protocol to ensure reliable evaluation. The results show that the proposed approach can effectively detect stress for several subjects while providing clear interpretability through direct comparison of ECG patterns. However, the performance varies across individuals due to differences in physiological responses, with some subjects exhibiting minimal morphological changes under stress. Additional analysis incorporating heart rate variability (HRV) features reveals that while HRV can improve performance in certain cases, its contribution is not consistent across all subjects. These findings highlight the importance of personalization and interpretability in physiological stress detection and demonstrate that motif-based approaches provide a meaningful alternative to black-box models, while also revealing inherent limitations due to inter-subject variability.

0.23

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

cs.AI eess.SP ·2026-09-24 ·Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady
similarity 0.56
Abstract

This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

0.08

Unlocking with the Heart: Investigating User Perceptions of ECG-Based Biometric Authentication

cs.HC cs.CRcs.CYcs.ET+1 ·2026-10-29 ·Farnaz Farid, Linet Momposhi, Tamara Watson, Alana Maurushat, Abubakar Bello +1 more
survey similarity 0.56
Abstract · 28

Password-based authentication remains challenging for many users, especially for those who face usability and accessibility issues. The burden of maintaining security can cause user fatigue, frustration and non-engagement. To address these issues, we conducted a pilot study to assess ECG-based biometric authentication as a passwordless alternative and to gather adult participants' perspectives on this approach. The research consisted of a survey study, an authentication prototype and a follow-up usability experience questionnaire. Our approach combined an online survey of 337 adults examining authentication practices and perceptions, with a separate usability evaluation in which 49 participants interacted with a simulated ECG-authentication and password interface in a health-care application prototype, then completed a post-test usability test questionnaire. The survey examined how adults across age groups use and perceive various authentication techniques, their experiences with biometrics, their views on security and convenience, and their willingness to adopt ECG authentication. In parallel, the usability prototype and questionnaire captured participants' responses after hands-on interaction with an ECG authentication prototype.

0.26