CS Paper Radar

Privacy-Preserving ECG-HRV Emotion Classification for Mood Swing Detection using Federated Learning on Constrained Edge Devices

Chidike Vincent, Muhammad Aslam Jarwar, Najam Ul Hasan, Laurence Hirsch, Jonathan Zasada-James, Hem Raj Dadra

cs.LG cs.AI ·submitted 2026-11-01 12:45 UTC · v1

Abstract

This paper presents a privacy-preserving mood monitoring framework that classifies emotional states from ECG-derived heart rate variability (HRV) features. The framework is evaluated on three public datasets comprising 74 participants and further validated using a wearable device in a pilot study. Leave-One-Participant-Out cross-validation (LOPO-CV) is used to assess generalization to unseen individuals. A series of experiments investigates the impact of temporal windowing, HRV feature selection, and class balancing on both four-class valence-arousal and binary valence classification. Results show that class balancing substantially improves minority-class recall, while Logistic Regression consistently outperforms five alternative classifiers and achieves competitive performance against HRV-based baselines. Pilot validation using a Polar H10 wearable achieves 75% binary valence accuracy on an unseen individual without calibration, demonstrating the feasibility of real-world deployment. To preserve privacy, the framework is also implemented using federated learning on a six-node Raspberry Pi cluster. Federated Logistic Regression achieves performance comparable to centralized training without sharing raw physiological data. These results demonstrate the potential of interpretable and privacy-preserving mood monitoring for continuous mental health assessment in clinical and community settings.

Closest papers

Nearest neighbours by meaning across the whole index.

Hybrid Quantum-inspired Kolmogorov-Arnold Networks for Privacy-Aware Federated Biosignal Learning

cs.LG cs.AIcs.DCcs.ET+1 ·2026-08-14 ·Chun-Hua Lin, Samuel Yen-Chi Chen, Yu-Chao Hsu, Kuo-Chung Peng, Jiun-Cheng Jiang +5 more
similarity 0.64
Abstract · 7 pages, 4 figures

Electrocardiogram (ECG) recordings are sensitive biomedical data, limiting the ability of hospitals and wearable devices to share raw signals for centralized model training. Federated learning addresses this practical privacy constraint by enabling collaborative model training while keeping raw biosignal data at their respective sources. However, federated ECG classification remains challenging due to limited client-side samples, imbalanced arrhythmia labels, and non-independent and identically distributed (non-IID) data across clients. These constraints require classifiers that are both communication-efficient and robust to cross-client distribution shifts. In this work, we evaluate a hybrid quantum-inspired Kolmogorov-Arnold network (HQKAN) against a multilayer perceptron (MLP) for five-class arrhythmia classification on the MIT-BIH dataset and three-class classification on the INCART dataset under federated averaging (FedAvg). Across multiple client configurations, HQKAN improves most aggregate and minority-class metrics while using 37.35% fewer trainable parameters and reducing communication cost by 24.89% on MIT-BIH; on INCART, it achieves corresponding reductions of 44.81% and 36.41%. These results indicate that HQKAN offers a compact, communication-efficient and robust alternative to the MLP baseline for privacy-aware federated learning on biosignal data.

0.07

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.64
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

Bridging the Gap in ECG-Based Emotion Recognition: A Unified Evaluation of Deep Learning Models

eess.SP cs.LG ·2026-09-14 ·Timothy C Sweeney-Fanelli, Ajan Ahmed, Masudul Imtiaz
publishedbenchmarkcode/data similarity 0.63
Abstract · Accepted at 2026 IEEE 17th Annual Ubiquitous Computing, Electronics & Mobile Communication Conference (UEMCON) - 2026 IEEE UEMCON

Deep learning has led to numerous proposed architectures for Automated Emotion Recognition (AER) from electrocardiogram (ECG) data, but inconsistencies in preprocessing, training, and evaluation make direct comparisons difficult. Most studies train and validate models on individual datasets collected under homogeneous conditions, limiting variability and raising concerns about generalizability. Cross-dataset validation is sometimes used but primarily assesses model adaptability rather than true generalization. This study presents a comparative analysis of prominent deep learning architectures in AER, emphasizing model generalization over dataset adaptability. To enable this benchmark, we introduce two open-source frameworks: Affective Research on Representations and Classifications (ARRC), a standardized benchmarking toolkit, and Affective Research Dataset Toolkit (ARDT), a framework for inter-dataset training and validation. Using ARDT, we consolidate three publicly available AER datasets, CUADS, ASCERTAIN, and DREAMER, into a single dataset, increasing variability in sensor types, recording conditions, and participant demographics. We then use ARRC to evaluate three widely studied deep learning models and two CNN baselines through hyperparameter optimization and 10-fold cross-validation. Our findings provide insights into the trade-offs between classification accuracy and model complexity, establishing a reproducible benchmark for AER research. All source code for ARRC, ARDT, and model evaluation is publicly available to ensure transparency and facilitate further research.

0.37

Emotion Recognition from Physiological Signals Using Machine Learning Algorithms Under Controlled Emotional Stimuli

eess.SP ·2026-09-04 ·Aditi Site, Annariina Lohiranta, Tarmo Lipping
similarity 0.62
Abstract

Emotion recognition using physiological signals plays a crucial role in well-being analysis, affective computing and human-computer interaction. This study investigates the performance of multiple machine learning models in classifying targets such as discrete emotions with varying granularity, valence and arousal using physiological signals such as Electrocardiogram (ECG) and Galvanic Skin Response (GSR). In here, we extracted various time- and frequency-domain features from the ECG and GSR data to train machine learning models. The results indicate that categorizing discrete emotions with fewer emotions and categorizing arousal achieves good classification accuracy with tree-based models. XGBoost achieved accuracy of 52.8 % for classifying discrete emotions and Random Forest achieved accuracy of 53.6% for classifying arousal. In both the cases, the combination of ECG+GSR feature sets achieved best performance. These findings highlight the effectiveness of physiological signals in capturing emotional states and support their use for emotion recognition systems.

0.26

NeuroPriv: Adversarial Representation Learning for Privacy in Wearable EEG Systems

cs.CR cs.HCcs.LG ·2026-08-31 ·Sarmistha Sarna Gomasta, Bhawana Chhaglani, Prashant Shenoy
similarity 0.61
Abstract

Wearable EEG systems may expose sensitive information beyond their intended health function, creating substantial risks to neuroprivacy. In this work, we show that commonly used EEG features can reveal participant identity and demographic attributes in addition to supporting the intended cognitive task. Wearable EEG is increasingly being explored for cognitive monitoring, neurological assessment, and longitudinal digital-health applications, yet many systems assume that transmitting compact spectral or spatial features instead of raw EEG provides sufficient privacy protection. Using EEGMAT as a motivating case study, we find that compact EEG features achieve a balanced accuracy of 0.788 for cognitive-state classification while enabling gender, age, and subject-identity inference with balanced accuracies of 0.858, 0.789, and 0.692, respectively. We further show that privacy-aware representation learning preserves task performance at 0.781 while reducing these inference accuracies to 0.563, 0.467, and 0.206. These findings motivate purpose-limited representations and explicit privacy auditing in wearable neurohealth systems.

0.42

From Stress to Affect: Multimodal Deep Learning for Physiological Emotion Recognition Across Wearable Sensor Modalities

cs.LG ·2026-09-17 ·Desta Haileselassie Hagos, Saurav Keshari Aryal, Legand L. Burge
similarity 0.57
Abstract · Under review

Physiological emotion recognition using wearable sensors has important applications in mental health monitoring, affective computing, and human-computer interaction. However, existing studies typically evaluate a single model, sensing configuration, or dataset, limiting our understanding of how these factors influence recognition performance. We present a comparative study of temporal deep learning architectures for physiological emotion recognition using two multimodal wearable datasets: WESAD and EmoWear. Bidirectional long short-term memory (LSTM), temporal convolutional network (TCN), and Transformer models are evaluated under wrist-only, chest-only, and multimodal sensing configurations using participant-independent leave-one-subject-out cross-validation (LOSO-CV). We also investigate soft-voting ensembles, sensor ablation, sampling frequency, and gradient-based saliency. The Transformer achieved the highest multimodal accuracy on WESAD (99.02% +/- 0.51%), whereas the LSTM achieved the best multimodal accuracy on EmoWear for both arousal (91.80% +/- 1.06%) and valence (89.96% +/- 0.36%). These results show that relative architecture performance depends on dataset characteristics rather than one architecture being uniformly superior. Multimodal sensing consistently outperformed wrist-only and chest-only configurations across both datasets. Sampling-frequency analysis showed that 4 Hz provides a practical operating point, with performance comparable to higher frequencies at substantially lower training cost. These findings provide guidance for selecting architectures, sensing modalities, and sampling frequencies for wearable physiological emotion recognition.

0.09

PULSE: Personalized Opportunistic Learning for Wearable Devices

cs.LG cs.AIcs.DC ·2026-10-20 ·Mattia Giovanni Campana, Dariush Salami, Hüseyin Yiğitler, Stephan Sigg
similarity 0.57
Abstract · Submitted to IEEE PerCom 2027

Wearable devices increasingly support personalized health and well-being applications, but post-deployment data can differ substantially from those used for training, while purely local adaptation may be limited by the data available on a single device during real-world operation. Conventional federated and decentralized learning rely on recurrent communication and stable connectivity, whereas existing opportunistic approaches often exploit available encounters without adequately considering their utility, compatibility, or communication cost. We propose PULSE, an event-driven framework for personalized opportunistic learning that treats each encounter as an online collaboration decision, selecting either no interaction or a promising nearby peer. Peer gradients are incorporated only when compatible with the local learning direction, while past interactions guide future peer selection. Across human activity recognition, fall detection, and stress recognition under synthetic and real contact traces, PULSE preserves or improves personalized classification performance, while reducing peer-assisted exchanges by 80-94% compared with opportunistic model averaging. On-device experiments further demonstrate its feasibility on wearable hardware: peer-assisted operations require limited energy, while the complete implementation occupies 149.8 KiB of RAM and 561.8 KiB of flash. The obtained results show that selective opportunistic collaboration can provide effective personalization while limiting communication and resource demands on constrained wearable devices.

0.26

Towards End-to-End Privacy-Preserving AI for Real-Time ECG Monitoring

cs.CR ·2026-10-18 ·Beyazit Bestami Yuksel
published similarity 0.57
Abstract · 9 pages, 4 figures, 2 tables. Accepted to MICCAI 2026 Doctoral Symposium (Springer LNCS)

Healthcare artificial intelligence is shifting from centralized archives toward distributed pipelines that combine wearables, edge processing, cloud analytics, and multi-institutional learning. In this regime, electrocardiogram (ECG) streams cross multiple trust boundaries, so privacy cannot be reduced to a single transmission control. Existing privacy-enhancing technologies typically secure isolated stages and leave gaps between acquisition, analysis, and institutional collaboration. This doctoral research develops a unified lifecycle framework for end-to-end privacy-preserving ECG AI. Rather than introducing another privacy mechanism, it orchestrates complementary privacy-enhancing technologies across the clinical ECG lifecycle, allocating each mechanism to the trust boundary where its security, computational, and operational properties are most appropriate. Three interoperable modules instantiate the framework: AES with CKKS-based homomorphic statistics for secure monitoring; adaptive chaotic protection for low-latency edge transmission; and federated learning with homomorphic aggregation under heterogeneous partitions. Across prototype monitoring, signal-security analysis, and simulated collaboration, the programme shows that privacy layers can be composed without collapsing diagnostic utility, while exposing overhead and fidelity limits that constrain clinical translation.

0.26