CS Paper Radar

Side-Vent Design for Microphone-Based Mechanomyography Sensors: Modeling and Experimental Evaluation of Contact Dependence

Cong Liu, Xiao Jin, Zhenhua Yu

cs.HC ·submitted 2026-10-11 13:23 UTC · v1

Abstract

Wearable muscle sensing for rehabilitation, assistive robotics, and electrical-stimulation feedback needs mechanomyography sensors less sensitive to fit changes during wear. In microphone-based mechanomyography, cavity pressure depends on rim contact, a dependence housing design has rarely targeted. This study evaluates a side-vented housing, whose vent opens a pressure-relief path in parallel with the rim to lower contact dependence, and quantifies the acoustic-gain cost. Thermoviscous finite-element simulations compared twenty cavity configurations under prescribed source motion. Paired bench sweeps over 10-200 Hz on both housings compared direct contact with a Gap-ring spacer, a radially grooved spacer ring. At 100 Hz, side venting reduced the simulated acoustic-gain variation across 0.10-0.50 mm rim clearances from 25.8 to 10.0 dB and cost 5.5 dB of gain at 0.20 mm clearance. Velocity fields and branch-flow calculations identified this path. At the higher speaker drive level, the Gap-ring spacer caused median attenuations of 13.6 dB (vented) and 30.1 dB (unvented) relative to direct contact. In this front end, a 35.9-dB signal-gain increase at 100 Hz raised the calculated operational-amplifier voltage-noise gain by 1.6 dB. A single-participant demonstration of paced elbow flexion and extension compared envelope timing and spectra between housings, finding similar envelope timing (correlation 0.935) and broadly similar spectra (correlation 0.956). Vent area trades acoustic gain against contact dependence and can therefore serve as a housing design parameter.

Comment
10 pages, 9 figures, 1 table. Submitted to IEEE Sensors Journal

Closest papers

Nearest neighbours by meaning across the whole index.

Performance Analysis and Design of an Optomechanical Microphone Using an Integrated Photonic Waveguide Interferometer

eess.AS eess.SYphysics.app-ph ·2026-09-21 ·Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall
unusual similarity 0.56
Abstract · 16 pages, 12 figures, 1 table

We present an optomechanical microphone based on a diaphragm-integrated photonic waveguide Mach-Zehnder interferometer. Acoustic pressure deforms the MEMS diaphragm, inducing strain in the sensing waveguide and changing its optical path length. We analytically evaluate the optical and mechanical transduction mechanisms and key figures of merit, including signal-to-noise ratio, dynamic range, acoustic overload pressure, and minimum detectable pressure. Two design cases are considered: a MEMS microphone and a measurement microphone. The results indicate competitive performance but no substantial overall advantage over state-of-the-art microphones in conventional applications. The architecture may nevertheless offer advantages for high-temperature and other harsh-environment sensing applications.

0.30

Modeling and Design of a Diaphragm-Integrated Photonic Waveguide Microphone

eess.AS ·2026-10-13 ·Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall
benchmark similarity 0.52
Abstract · 14 pages

Can an integrated optical readout improve the useful operating range of a miniature microphone? We address this question with an analytical model of a diaphragm carrying the sensing arm of a Mach-Zehnder interferometer (MZI). The model links pressure-induced bending to waveguide elongation and then to photocurrent, allowing mechanical sensitivity and optical detection limits to be assessed separately. Optical shot noise and back-cavity thermomechanical noise set the pressure resolution, while a 10% total harmonic distortion criterion defines acoustic overload. Two operating regimes are examined: a compact MEMS microphone with 1 mW optical input and a measurement microphone with 100 mW optical input. For the compact case, a 1 mm diameter, 1 micrometer thick, stress-free silicon diaphragm and 100% modulation efficiency give a predicted signal-to-noise ratio of 78 dB and acoustic overload pressure of 124 dB. The higher-power case lowers the modeled noise floor and increases dynamic range relative to the selected measurement microphone benchmark. These estimates rely on favorable assumptions and do not establish a substantial overall advantage in conventional microphone applications. Remote optical interrogation offers a separate motivation for harsh-environment sensing, but the temperature tolerance of the proposed sensing head remains unverified. The analysis identifies the design tradeoffs and measurements needed to test the predicted performance.

0.09

Speech-muscle coupling at jaw and ear electrodes: a volume-conductor model with orientation and electrode-count controls

cs.HC eess.SP ·2026-08-12 ·Carl Vincent Kho
code/data similarity 0.51
Abstract · Revised title, abstract and text. Reported both derived fibre models; clarified protocol history and current-normalization limits. Added a g…

Objective. We compared how strongly speech-muscle sources couple to electrodes on the jaw and around the ear, and tested sensitivity to source orientation, electrode count, and anatomical detail. Approach. Using reciprocity in MIDA (116 labelled compartments, 500 micrometres), we evaluated 22 electrode positions against ten segmented articulators. Muscle was modelled as both source and conducting tissue. Comparisons used equal electrode counts and a hemisphere orientation sweep, with anatomy-derived fibre models for temporalis and lateral pterygoid. Results. Orbicularis oris, buccinator, mentalis, depressor anguli oris, and platysma favoured the jaw at every sampled orientation and tested electrode subset. Temporalis showed a 2.57 dB ear advantage under the uniform sweep, reduced to 1.15 dB with the derived fibre field. Its jaw-minus-ear interval [-1.45, +5.46] dB crossed zero; 50.5% of four-site ear subsets favoured the ear. The derived lateral-pterygoid interval [-5.33, -1.12] dB favoured the ear at the fixed jaw basis. Both derived constructions have unresolved anatomical limitations. Simplifying non-muscle soft-tissue conductivities preserved montage assignments while changing gaps by up to 3.27 dB. Significance. In this head model, jaw placement better captures lip and chin activity. Ear-side preferences depend on source assumptions and electrode selection. Targeted four-site placement improved lateral-pterygoid coupling by 1.07 dB over the median random ear montage. These coupling predictions require experimental testing.

0.24

A Device to Control and Manipulate Occlusion Effects for Own Voice Perception Studies

eess.AS ·2026-09-11 ·Rouben Rehman, Simon Kersten, Aron Schliep, Janina Fels
similarity 0.49
Abstract

The occlusion effect (OE) refers to changes of the eardrum sound pressure through ear canal occlusion. It consists of two phenomena: an insertion loss (IL) attenuating air-conducted sounds, and an occlusion gain (OG) amplifying bone-conduction. Perceptual research on this is hindered by high variability of the OE across individuals, complicating repeatable presentation of precise OE conditions. Consequently, a method to control OE conditions reproducibly during perceptual experiments is needed. For such investigations, the system must enable separate control of IL and OG. We present an approach based on modified commercial earmuffs with integrated microphones. The design integrates dedicated impedance measurements and the derivation of digital filters, which are applied to the microphone signals to emulate arbitrary OE curves. The system is evaluated objectively through appropriate measurements. Results show that the headphones' inherent OG is guaranteed to be below 6dB above 115Hz, falling below 0dB above 155Hz. Emulation is shown to work accurately over the entire frequency range of interest. Limitations arise mainly due to a slight residual inherent OG for deep voices and the processing delay of the system. Future work will focus on the perceptual evaluation of the system and its application in perceptual studies.

0.20

Sensing Bone-Conducted Speech with Earbuds

eess.AS ·2026-09-02 ·Christoph Weyer, Peter Jax
published similarity 0.48
Abstract · 14 pages, 12 figures, journal

Clear capture of the wearer's own voice (OV) is essential when using earbuds for mobile communication. However, OV capture remains challenging in noisy environments. Bone-conducted (BC) speech, which can be sensed as vibrations of the earbud housing, can be used to improve OV capture. However, neither bandwidth nor spatial characteristics of OV-induced earbud vibrations have been analyzed in detail, despite both characteristics being relevant, e.g., for sensor choice and placement. This study investigates both characteristics, based on measurements with two earbud models. Spectrally, results indicate that OV-induced earbud vibrations exhibit a low-pass characteristic, with a steep roll-off of -93 dB per decade above 400 Hz. Thus, sensors with comparatively low noise floors are required to sense the vibrations above \SI{1}{\kilo\hertz}. Spatially, results indicate that the earbuds mainly vibrate in and out of the ear canal entrance, with high consistency between subjects and fits. Simulations confirm that this enables capture of the high-power vibrations below 400 Hz by a single-axis sensor with less than 1.5 dB mean attenuation.

0.39

The Hearpiece Database of Binaural Room Impulse Responses and Driver Responses on KEMAR

eess.AS ·2026-11-04 ·Tong Xiao, Reinhild Roden, Matthias Blau, Simon Doclo
similarity 0.48
Abstract · 13 pages, 7 figures, 5 tables. Database and MATLAB loading script available at https://doi.org/10.5281/zenodo.23667308

This document describes the measurement setup, signal processing, data organization, and MATLAB file format of a database of acoustic responses measured on a Knowles Electronics Manikin for Acoustic Research (KEMAR) using the Hearpiece, a multi-microphone, multi-driver in-ear research device. The data include binaural room impulse responses (BRIRs) and Hearpiece driver responses, together with center-microphone room impulse responses and a loopback impulse response of the playback and recording system. The BRIRs cover two Hearpiece configurations, three room conditions, three independent insertions per configuration, and 24 horizontal source directions. The database supports reproducible research on binaural and hearing-device signal processing, with potential applications in speech enhancement, spatial filtering and source separation, dereverberation, active noise and occlusion control, and acoustic feedback cancellation. The database, MATLAB loading script, and technical documentation are publicly available at https://doi.org/10.5281/zenodo.23667308.

0.35

Design and Validation of a Lightweight, Low-Profile Powered Knee Prosthesis with Quasi-Direct Drive Actuation

cs.RO ·2026-09-02 ·Ross J. Cortino, Ryan Posh, Emily G. Keller, Robert D. Gregg
similarity 0.47
Abstract · 11 pages, 8 figures, Under Review

Fully-powered knee prostheses, unlike traditional passive knees, can perform controlled positive work, reducing the need for compensatory behaviors by users during energy-intensive activities. While quasi-direct drive (QDD) actuators provide superior torque control, backdrivability, and acoustic noise properties compared to traditional highly-geared actuators, prior QDD prototypes have been too heavy and bulky for commercial translation. In this work, we present the design and validation of a new lightweight (2.6 kg) and low-profile (24.5 cm tip-to-tip build height) QDD knee prosthesis. By optimizing an 18 to 1 two-stage transmission alongside thermal and structural finite-element analyses, we significantly reduce device mass while enabling a peak torque of 145 Nm. Through benchtop tests, we validate the device's high output torque, low backdrive torque (1 Nm), and its precision position and torque control capabilities. We also demonstrate biomimetic kinematics and peak knee extension torques (within one standard deviation of able-bodied references) during both level-ground walking and sit-stand transitions performed by three participants with transfemoral amputation and varying K-levels. By meeting or improving upon the mass, build height, peak torque, and acoustic noise of a leading commercial powered knee, this work establishes the clinical viability of emerging QDD prostheses that promise improved dynamic performance for their users.

0.32

Towards Effective Physical Reservoir Computing with a Pneumatic Soft Robot

cs.RO ·2026-09-02 ·Jeevan Hebbal Manjunath, Jun Wang, Suyi Li, Wenlong Zhang
publishedbenchmark similarity 0.46
Abstract · 6 pages; 5 figures, accepted for 2026 Modeling, Estimation, and Control Conference (MECC)

Physical reservoir computing (PRC) refers to the use of a physical dynamical system as a computational resource for tasks such as state estimation and control, but there has been a lack of formal study of design rules towards more effective design of such physical reservoirs. Using a pneumatic soft arm with a five-pouch sensing column, this work studies how the pouch interconnection topology, robot stiffness, and the number of instrumented sensors affect bending-angle estimation performance. Across 36 matched trials spanning waveform, baseline pressure of the sensing column, and actuation range, all designs are evaluated under the same-time bending-angle estimation benchmark using 0.2 s of pressure history and a fixed ridge estimator. Our analysis of the experimental results leads to three design guidelines. First, independently sealed pouches preserve a much richer observable state than a shared manifold. Second, increasing the baseline pressure of the sensing column makes the pouch responses more redundant and increases estimation error most strongly in the coupled topology. Third, in the sealed topology, two strategically placed sensors already recover most of the attainable benefit, three capture essentially all of it, and additional sensors provide little or no additional value. In summary, the results suggest that topology, stiffness, and number of instrumented sensors should be co-designed for accurate PRC of soft robot states; stronger excitation alone cannot recover the diversity that poor design choices have already removed.

0.30