CS Paper Radar

Performance Analysis and Design of an Optomechanical Microphone Using an Integrated Photonic Waveguide Interferometer

Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall

eess.AS eess.SYphysics.app-ph ·submitted 2026-09-21 03:58 UTC · v2
unusual

Abstract

We present an optomechanical microphone based on a diaphragm-integrated photonic waveguide Mach-Zehnder interferometer. Acoustic pressure deforms the MEMS diaphragm, inducing strain in the sensing waveguide and changing its optical path length. We analytically evaluate the optical and mechanical transduction mechanisms and key figures of merit, including signal-to-noise ratio, dynamic range, acoustic overload pressure, and minimum detectable pressure. Two design cases are considered: a MEMS microphone and a measurement microphone. The results indicate competitive performance but no substantial overall advantage over state-of-the-art microphones in conventional applications. The architecture may nevertheless offer advantages for high-temperature and other harsh-environment sensing applications.

Comment
16 pages, 12 figures, 1 table

Closest papers

Nearest neighbours by meaning across the whole index.

Modeling and Design of a Diaphragm-Integrated Photonic Waveguide Microphone

eess.AS ·2026-10-13 ·Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall
benchmark similarity 0.88
Abstract · 14 pages

Can an integrated optical readout improve the useful operating range of a miniature microphone? We address this question with an analytical model of a diaphragm carrying the sensing arm of a Mach-Zehnder interferometer (MZI). The model links pressure-induced bending to waveguide elongation and then to photocurrent, allowing mechanical sensitivity and optical detection limits to be assessed separately. Optical shot noise and back-cavity thermomechanical noise set the pressure resolution, while a 10% total harmonic distortion criterion defines acoustic overload. Two operating regimes are examined: a compact MEMS microphone with 1 mW optical input and a measurement microphone with 100 mW optical input. For the compact case, a 1 mm diameter, 1 micrometer thick, stress-free silicon diaphragm and 100% modulation efficiency give a predicted signal-to-noise ratio of 78 dB and acoustic overload pressure of 124 dB. The higher-power case lowers the modeled noise floor and increases dynamic range relative to the selected measurement microphone benchmark. These estimates rely on favorable assumptions and do not establish a substantial overall advantage in conventional microphone applications. Remote optical interrogation offers a separate motivation for harsh-environment sensing, but the temperature tolerance of the proposed sensing head remains unverified. The analysis identifies the design tradeoffs and measurements needed to test the predicted performance.

0.09

Side-Vent Design for Microphone-Based Mechanomyography Sensors: Modeling and Experimental Evaluation of Contact Dependence

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.56
Abstract · 10 pages, 9 figures, 1 table. Submitted to IEEE Sensors Journal

Wearable muscle sensing for rehabilitation, assistive robotics, and electrical-stimulation feedback needs mechanomyography sensors less sensitive to fit changes during wear. In microphone-based mechanomyography, cavity pressure depends on rim contact, a dependence housing design has rarely targeted. This study evaluates a side-vented housing, whose vent opens a pressure-relief path in parallel with the rim to lower contact dependence, and quantifies the acoustic-gain cost. Thermoviscous finite-element simulations compared twenty cavity configurations under prescribed source motion. Paired bench sweeps over 10-200 Hz on both housings compared direct contact with a Gap-ring spacer, a radially grooved spacer ring. At 100 Hz, side venting reduced the simulated acoustic-gain variation across 0.10-0.50 mm rim clearances from 25.8 to 10.0 dB and cost 5.5 dB of gain at 0.20 mm clearance. Velocity fields and branch-flow calculations identified this path. At the higher speaker drive level, the Gap-ring spacer caused median attenuations of 13.6 dB (vented) and 30.1 dB (unvented) relative to direct contact. In this front end, a 35.9-dB signal-gain increase at 100 Hz raised the calculated operational-amplifier voltage-noise gain by 1.6 dB. A single-participant demonstration of paced elbow flexion and extension compared envelope timing and spectra between housings, finding similar envelope timing (correlation 0.935) and broadly similar spectra (correlation 0.956). Vent area trades acoustic gain against contact dependence and can therefore serve as a housing design parameter.

0.31

An Ultra-Low-Noise Tunable TIA in 45nm Silicon Photonics for Electro-Optical Ultrasound Data Acquisition

eess.SP eess.SY ·2026-11-06 ·Marziyeh Rezaei, Sridhar Singhal, Alp A. Derin, Soner Sonmezoglu, Sajjad Moazeni
unusual similarity 0.48
Abstract

This paper presents the design and experimental characterization of a 32-channel, WDM-compatible electronic-photonic receiver array fabricated in the GlobalFoundries 45nm monolithic silicon photonics process. Optimized for miniaturized, millimeter-scale electro-optical ultrasound data acquisition probes for broadband photo-acoustic imaging (PAI), the chip utilizes integrated micro-ring resonator (MRR) demultiplexers and photodiode (PD) arrays to decode multi-wavelength acoustic signals outside the body. This work focuses specifically on the comprehensive characterization of the receiver front-end, evaluating both the optical WDM filter bank and the transimpedance amplifier (TIA) performance. Monolithic co-integration minimizes critical photodiode-to-TIA interface parasitics. The TIA incorporates a DC-offset cancellation loop that compensates for photodiode-induced offset currents while providing tunable low-frequency cutoff control over a range of 30 kHz to 1.5 MHz. This tunability enables effective suppression of flicker noise and improves overall signal integrity. The front-end achieves the peak transimpedance gain of 144 dB$Ω$ while maintaining an ultra-low input-referred noise current density of $1\text{ pA}/\sqrt{\text{Hz}}$, demonstrating a highly scalable architecture for high-sensitivity intravascular and endobronchial imaging.

0.29

Non-Imaging Optical Tactile Sensors for Robotics: Transduction Principles, System Integration, and Robotic Applications

cs.RO ·2026-11-16 ·Hao Wu, Yu Feng, Haotian Guo, Huichan Zhao, Changsheng Wu +1 more
similarity 0.46
Abstract · 35 pages, 9 figures

Non-imaging optical tactile sensors encode contact through changes in optical intensity, wavelength, spectra, or photon counts, offering diverse architectures for robotic touch. Their usefulness depends on whether contact variables can be reliably distinguished from coupled mechanical and environmental effects, and whether the resulting information can be delivered in time to guide action. This review develops a unified framework linking mechanical load transmission, optical encoding, readout, and tactile inference to robotic task requirements. It examines reflective and waveguide-based devices, micro/nanofibers, fiber gratings, interferometric and resonant structures, and mechanoluminescent composites. Three considerations emerge across these approaches. First, high optical sensitivity supports accurate tactile estimation only when target variables remain identifiable under the relevant contact and calibration conditions. Second, spatial coverage and feedback timing must be assessed at the system level, accounting for multiplexing, acquisition, demodulation, and inference. Third, device characterization, offline recognition, and closed-loop robotic performance provide distinct levels of evidence and require different evaluation criteria. Representative studies illustrate how these considerations shape force estimation, contact localization, slip correction and distributed interaction. This review concludes with priorities for calibration transfer, reliable interfaces, scalable readout, and task-based validation, providing a basis for selecting and developing non-imaging optical tactile architectures for robotics.

0.16

Comparative Robustness of Mach-Zehender and Microring Photonic Matrix Multipliers Under Laser RIN and Thermal Drift

cs.AR physics.optics ·2026-10-11 ·Andreas Falkenberg
similarity 0.43
Abstract · 22 pages, 16 figures

Photonic matrix multipliers can accelerate neural-network inference, but their practical utility depends on how optical weight elements respond to source noise, thermal variation, and calibration error. This paper compares Mach-Zehnder modulator (MZM) and microring-resonator (MRR) implementations under laser relative-intensity noise (RIN), column-wise thermal/phase drift, and their joint action. Two CIFAR-10 classifiers - a compact four-layer CNN and ResNet-8 - are mapped to matched photonic multiply-accumulate chains using common source-distribution, detection, numerical, and calibration assumptions. Both architectures reproduce the same zero-perturbation baseline for each workload: 79.5% classification accuracy for the Small CNN and 70.0% for ResNet-8. Robustness is then evaluated using separate RIN-only and drift-only sweeps and a full two-dimensional RIN-drift grid, with dimensionless RMS perturbation levels extending from 0.5% to 20%. The analysis reports classification accuracy, class normalized confusion matrices, rolling-accuracy traces, one-dimensional robustness curves, and multidimensional response surfaces. Device equations and parameter definitions follow the models implemented in the QPI Labs Photonic Inference Simulator, with shared laser fluctuations propagated as correlated multiplicative noise and slow drift represented as a per-output-column perturbation of calibrated weights. All numerical results are generated from recorded experiment configurations and random seeds. The study provides a controlled system-level framework for comparing interferometric and resonant photonic weight elements while limiting conclusions to the implemented device models, perturbation ranges, calibration policy, and neural-network workloads.

0.52

WAVES: Wearable Active Vibroacoustic Elasticity Sensing for Low-Cost and Non-Invasive Muscle Stiffness Monitoring

cs.ET ·2026-11-04 ·Shubham Rohal, Dong Yoon Lee, Shijia Pan
similarity 0.43
Abstract

Muscle stiffness is a physiologically meaningful biomarker associated with a wide range of musculoskeletal and neurological conditions. However, existing muscle stiffness assessment methods, such as shear wave elastography (SWE), manual palpation, and handheld mechanical probes, remain impractical for continuous, everyday monitoring due to bulky hardware, operator dependence, and limited self-use. Meanwhile, wearable muscle-sensing modalities such as Electromyography (EMG) and Mechanomyography (MMG) primarily capture muscle activation rather than passive mechanical properties of tissue at rest, leaving a critical gap in portable monitoring of resting muscle stiffness. In this work, we present WAVES, a wearable system for continuous monitoring of muscle stiffness via active vibroacoustic sensing. WAVES injects controlled vibroacoustic excitation into soft tissue and estimates muscle stiffness by measuring shear-wave propagation velocity through Time-Difference-of-Arrival (TDoA) analysis across spatially distributed wearable sensors. To achieve accurate TDoA estimation with low-cost wearable hardware, we develop a physiology- and quality-guided vibroacoustic sensing framework that effectively screens and refines TDoA for accurate stiffness estimation. We evaluate WAVES through characterization experiments using ballistic jelly and end-to-end on-body evaluation with human participants. Results demonstrate that WAVES can robustly estimate muscle stiffness across multiple users and different superficial muscles while enabling lightweight, wearable deployment for everyday use. WAVES is able to achieve a muscle stiffness estimation error of 13.1% or less across multiple users and multiple muscle groups.

0.25

20 ghz longitudinal surface acoustic wave resonators in 100-nm x-cut lithium niobate on silicon carbide

eess.SP ·2026-11-19 ·Jiajun Huang, Ziqian Yao, Tzu-Hsuan Hsu, Ian Anderson, Joshua Campbell +1 more
similarity 0.41
Abstract

Surface acoustic wave (SAW) resonators above 15~GHz require a fast acoustic mode that retains strong electromechanical coupling ($k^2$). This work reports longitudinal SAW (L-SAW) resonators designed for high $k^2$ in 100-nm X-cut lithium niobate (LN) on 4H silicon carbide (SiC), operating up to 21.7~GHz and reaching a $k^2$ of 8.1\%, a maximum Bode $Q$ of 70, and a figure of merit (FoM) of 5.7 at 20.24~GHz. In this thin-film waveguide, shrinking the wavelength ($λ$) keeps the normalized LN thickness ($h_\mathrm{LN}/λ$) large, sustaining both $k^2$ and acoustic confinement. Conversely, increasing $λ$ from 292 to 471~nm lowers $h_\mathrm{LN}/λ$ from 0.34 to 0.21 and raises the L-SAW phase velocity from 6.32 to 7.05~km/s, within 1.1\% of the 7126-m/s shear-wave velocity of 4H-SiC. As the velocity approaches this limit, more of the acoustic energy spreads into the non-piezoelectric SiC, and $k^2$ falls from its 8.1\% peak at $λ= 322$~nm to 1.7\% at $λ= 471$~nm. No L-SAW resonance is observed for $λ\geq 518$~nm ($h_\mathrm{LN}/λ\leq 0.19$), where the mode becomes leaky. Overall, the FoM stays within 5\% of its maximum for $h_\mathrm{LN}/λ$ between 0.26 to 0.31, defining a design window for L-SAW resonators in thin LN on SiC at K-band and beyond.

0.27

Virtual Microphone Array for Direction-of-Arrival Estimation Based on Fiber-Optic Position Sensing

eess.AS ·2026-11-04 ·Sebastian Schwarze, Jiekai Wang, Thomas Kissinger, Stephan Werner
unusual similarity 0.41
Abstract · 11 pages, 7 figures

This paper presents a virtual microphone array approach for estimating the direction of arrival of a sound source using a moving microphone and a stationary reference microphone. The method exploits the microphone motion to generate a time-varying array geometry, using fiber-optic position sensing to reconstruct the trajectory and determine the resulting virtual microphone configurations. For each configuration, the estimated time difference of arrival between the two microphone signals and the corresponding microphone geometry define a hyperboloid representing all possible sound source positions consistent with the time difference. By combining multiple hyperboloid constraints, the direction of arrival can be estimated in azimuth and elevation relative to the microphone coordinate system. In contrast to conventional arrays with fixed geometries and approaches based on predefined microphone trajectories, the proposed method derives the virtual array geometry directly from the measured microphone motion, enabling a spatially distributed virtual array to be formed using only two physical microphones and offering potential for size- and weight-constrained applications. The approach was experimentally evaluated under controlled low-reflection conditions for different source positions, source distances, and signal characteristics. The influence of microphone motion was further examined, and the method was tested with a moving sound source. The results demonstrate the feasibility of direction-of-arrival estimation using a virtual microphone array without requiring a predefined microphone trajectory.

0.29