CS Paper Radar

Modeling and Design of a Diaphragm-Integrated Photonic Waveguide Microphone

Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall

eess.AS ·submitted 2026-10-13 05:23 UTC · v1
benchmark

Abstract

Can an integrated optical readout improve the useful operating range of a miniature microphone? We address this question with an analytical model of a diaphragm carrying the sensing arm of a Mach-Zehnder interferometer (MZI). The model links pressure-induced bending to waveguide elongation and then to photocurrent, allowing mechanical sensitivity and optical detection limits to be assessed separately. Optical shot noise and back-cavity thermomechanical noise set the pressure resolution, while a 10% total harmonic distortion criterion defines acoustic overload. Two operating regimes are examined: a compact MEMS microphone with 1 mW optical input and a measurement microphone with 100 mW optical input. For the compact case, a 1 mm diameter, 1 micrometer thick, stress-free silicon diaphragm and 100% modulation efficiency give a predicted signal-to-noise ratio of 78 dB and acoustic overload pressure of 124 dB. The higher-power case lowers the modeled noise floor and increases dynamic range relative to the selected measurement microphone benchmark. These estimates rely on favorable assumptions and do not establish a substantial overall advantage in conventional microphone applications. Remote optical interrogation offers a separate motivation for harsh-environment sensing, but the temperature tolerance of the proposed sensing head remains unverified. The analysis identifies the design tradeoffs and measurements needed to test the predicted performance.

Comment
14 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Performance Analysis and Design of an Optomechanical Microphone Using an Integrated Photonic Waveguide Interferometer

eess.AS eess.SYphysics.app-ph ·2026-09-21 ·Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall
unusual similarity 0.88
Abstract · 16 pages, 12 figures, 1 table

We present an optomechanical microphone based on a diaphragm-integrated photonic waveguide Mach-Zehnder interferometer. Acoustic pressure deforms the MEMS diaphragm, inducing strain in the sensing waveguide and changing its optical path length. We analytically evaluate the optical and mechanical transduction mechanisms and key figures of merit, including signal-to-noise ratio, dynamic range, acoustic overload pressure, and minimum detectable pressure. Two design cases are considered: a MEMS microphone and a measurement microphone. The results indicate competitive performance but no substantial overall advantage over state-of-the-art microphones in conventional applications. The architecture may nevertheless offer advantages for high-temperature and other harsh-environment sensing applications.

0.30

Side-Vent Design for Microphone-Based Mechanomyography Sensors: Modeling and Experimental Evaluation of Contact Dependence

cs.HC ·2026-10-11 ·Cong Liu, Xiao Jin, Zhenhua Yu
similarity 0.52
Abstract · 10 pages, 9 figures, 1 table. Submitted to IEEE Sensors Journal

Wearable muscle sensing for rehabilitation, assistive robotics, and electrical-stimulation feedback needs mechanomyography sensors less sensitive to fit changes during wear. In microphone-based mechanomyography, cavity pressure depends on rim contact, a dependence housing design has rarely targeted. This study evaluates a side-vented housing, whose vent opens a pressure-relief path in parallel with the rim to lower contact dependence, and quantifies the acoustic-gain cost. Thermoviscous finite-element simulations compared twenty cavity configurations under prescribed source motion. Paired bench sweeps over 10-200 Hz on both housings compared direct contact with a Gap-ring spacer, a radially grooved spacer ring. At 100 Hz, side venting reduced the simulated acoustic-gain variation across 0.10-0.50 mm rim clearances from 25.8 to 10.0 dB and cost 5.5 dB of gain at 0.20 mm clearance. Velocity fields and branch-flow calculations identified this path. At the higher speaker drive level, the Gap-ring spacer caused median attenuations of 13.6 dB (vented) and 30.1 dB (unvented) relative to direct contact. In this front end, a 35.9-dB signal-gain increase at 100 Hz raised the calculated operational-amplifier voltage-noise gain by 1.6 dB. A single-participant demonstration of paced elbow flexion and extension compared envelope timing and spectra between housings, finding similar envelope timing (correlation 0.935) and broadly similar spectra (correlation 0.956). Vent area trades acoustic gain against contact dependence and can therefore serve as a housing design parameter.

0.31

An Ultra-Low-Noise Tunable TIA in 45nm Silicon Photonics for Electro-Optical Ultrasound Data Acquisition

eess.SP eess.SY ·2026-11-06 ·Marziyeh Rezaei, Sridhar Singhal, Alp A. Derin, Soner Sonmezoglu, Sajjad Moazeni
unusual similarity 0.51
Abstract

This paper presents the design and experimental characterization of a 32-channel, WDM-compatible electronic-photonic receiver array fabricated in the GlobalFoundries 45nm monolithic silicon photonics process. Optimized for miniaturized, millimeter-scale electro-optical ultrasound data acquisition probes for broadband photo-acoustic imaging (PAI), the chip utilizes integrated micro-ring resonator (MRR) demultiplexers and photodiode (PD) arrays to decode multi-wavelength acoustic signals outside the body. This work focuses specifically on the comprehensive characterization of the receiver front-end, evaluating both the optical WDM filter bank and the transimpedance amplifier (TIA) performance. Monolithic co-integration minimizes critical photodiode-to-TIA interface parasitics. The TIA incorporates a DC-offset cancellation loop that compensates for photodiode-induced offset currents while providing tunable low-frequency cutoff control over a range of 30 kHz to 1.5 MHz. This tunability enables effective suppression of flicker noise and improves overall signal integrity. The front-end achieves the peak transimpedance gain of 144 dB$Ω$ while maintaining an ultra-low input-referred noise current density of $1\text{ pA}/\sqrt{\text{Hz}}$, demonstrating a highly scalable architecture for high-sensitivity intravascular and endobronchial imaging.

0.29

Non-Imaging Optical Tactile Sensors for Robotics: Transduction Principles, System Integration, and Robotic Applications

cs.RO ·2026-11-16 ·Hao Wu, Yu Feng, Haotian Guo, Huichan Zhao, Changsheng Wu +1 more
similarity 0.46
Abstract · 35 pages, 9 figures

Non-imaging optical tactile sensors encode contact through changes in optical intensity, wavelength, spectra, or photon counts, offering diverse architectures for robotic touch. Their usefulness depends on whether contact variables can be reliably distinguished from coupled mechanical and environmental effects, and whether the resulting information can be delivered in time to guide action. This review develops a unified framework linking mechanical load transmission, optical encoding, readout, and tactile inference to robotic task requirements. It examines reflective and waveguide-based devices, micro/nanofibers, fiber gratings, interferometric and resonant structures, and mechanoluminescent composites. Three considerations emerge across these approaches. First, high optical sensitivity supports accurate tactile estimation only when target variables remain identifiable under the relevant contact and calibration conditions. Second, spatial coverage and feedback timing must be assessed at the system level, accounting for multiplexing, acquisition, demodulation, and inference. Third, device characterization, offline recognition, and closed-loop robotic performance provide distinct levels of evidence and require different evaluation criteria. Representative studies illustrate how these considerations shape force estimation, contact localization, slip correction and distributed interaction. This review concludes with priorities for calibration transfer, reliable interfaces, scalable readout, and task-based validation, providing a basis for selecting and developing non-imaging optical tactile architectures for robotics.

0.16

Comparative Robustness of Mach-Zehender and Microring Photonic Matrix Multipliers Under Laser RIN and Thermal Drift

cs.AR physics.optics ·2026-10-11 ·Andreas Falkenberg
similarity 0.45
Abstract · 22 pages, 16 figures

Photonic matrix multipliers can accelerate neural-network inference, but their practical utility depends on how optical weight elements respond to source noise, thermal variation, and calibration error. This paper compares Mach-Zehnder modulator (MZM) and microring-resonator (MRR) implementations under laser relative-intensity noise (RIN), column-wise thermal/phase drift, and their joint action. Two CIFAR-10 classifiers - a compact four-layer CNN and ResNet-8 - are mapped to matched photonic multiply-accumulate chains using common source-distribution, detection, numerical, and calibration assumptions. Both architectures reproduce the same zero-perturbation baseline for each workload: 79.5% classification accuracy for the Small CNN and 70.0% for ResNet-8. Robustness is then evaluated using separate RIN-only and drift-only sweeps and a full two-dimensional RIN-drift grid, with dimensionless RMS perturbation levels extending from 0.5% to 20%. The analysis reports classification accuracy, class normalized confusion matrices, rolling-accuracy traces, one-dimensional robustness curves, and multidimensional response surfaces. Device equations and parameter definitions follow the models implemented in the QPI Labs Photonic Inference Simulator, with shared laser fluctuations propagated as correlated multiplicative noise and slow drift represented as a per-output-column perturbation of calibrated weights. All numerical results are generated from recorded experiment configurations and random seeds. The study provides a controlled system-level framework for comparing interferometric and resonant photonic weight elements while limiting conclusions to the implemented device models, perturbation ranges, calibration policy, and neural-network workloads.

0.28

A Device to Control and Manipulate Occlusion Effects for Own Voice Perception Studies

eess.AS ·2026-09-11 ·Rouben Rehman, Simon Kersten, Aron Schliep, Janina Fels
similarity 0.43
Abstract

The occlusion effect (OE) refers to changes of the eardrum sound pressure through ear canal occlusion. It consists of two phenomena: an insertion loss (IL) attenuating air-conducted sounds, and an occlusion gain (OG) amplifying bone-conduction. Perceptual research on this is hindered by high variability of the OE across individuals, complicating repeatable presentation of precise OE conditions. Consequently, a method to control OE conditions reproducibly during perceptual experiments is needed. For such investigations, the system must enable separate control of IL and OG. We present an approach based on modified commercial earmuffs with integrated microphones. The design integrates dedicated impedance measurements and the derivation of digital filters, which are applied to the microphone signals to emulate arbitrary OE curves. The system is evaluated objectively through appropriate measurements. Results show that the headphones' inherent OG is guaranteed to be below 6dB above 115Hz, falling below 0dB above 155Hz. Emulation is shown to work accurately over the entire frequency range of interest. Limitations arise mainly due to a slight residual inherent OG for deep voices and the processing delay of the system. Future work will focus on the perceptual evaluation of the system and its application in perceptual studies.

0.20

13,000-Fold Frequency Down Conversion From 280 MHz to 21 kHz Using Mechanical Frequency Combs

eess.SP ·2026-11-05 ·Ian Anderson, Zihuan Liu, Vivek Tallavajhula, Yen-Chen Wang, Tzu-Hsuan Hsu +2 more
unusual similarity 0.42
Abstract · 4 pages, 6 figures

Optical frequency combs bridge the microwave and terahertz regimes by down-converting terahertz optical energy into microwave signals. A photodetector converts the comb's equally spaced lines, generated through optical nonlinearities, into a low-frequency tone at their spacing. Here, we present the first mechanical version of this process, using mechanical frequency combs to downconvert energy over 4 orders of magnitude, from the MHz to kHz regime. Thin-film lithium niobate (LN) is used to design an acoustic resonator with a wide range of mode frequencies. We achieve phononic comb excitation from 250 MHz to 900 MHz and compare the electrical and laser Doppler vibrometer (LDV) measurements at 277 MHz. We then show the low-frequency spectrum of the devices, highlighting mechanical motion at the comb's spacing and demonstrating energy transfer from 277 MHz to 21 kHz.

0.30

Multirate State Space Models for End-to-End Processing of Pulse Density Modulated Speech Signals

cs.SD eess.AS ·2026-08-28 ·Ludovic Boulanger, Sean U. N. Wood
similarity 0.42
Abstract

Deep neural networks (DNNs) based on state-space models (SSMs) are increasingly applied to speech processing, but typically operate on pulse-code-modulated (PCM) audio. This constrains deployment on low-power, always-on edge devices, which commonly use single-bit pulse-density-modulated (PDM) micro-electromechanical (MEMS) microphones for their noise robustness, low cost, and variable sampling rates that enable low-power operation. In fact, converting PDM to PCM requires low-pass filtering and decimation, imposing costly overhead on resource-constrained hardware. While prior works have attempted to process PDM signals directly, they require long training times and generalize poorly across sampling rates. In this paper, we show that the SSM has two key properties that remediate these issues: its continuous-time parametrization allows it to produce a consistent representation of the input audio signal, regardless of the modulation strategy and sampling rate, and its long-term memory enables this representation to be aggressively downsampled without needing any anti-aliasing operations. We then propose a novel end-to-end PDM speech processing architecture that uses an SSM to encode the input audio signal into a modulation- and sampling-rate-invariant latent representation. We show that our proposed architecture achieves robust speech classification and enhancement gains at low-power sampling-rates (512 kHz) and similar performance to state-of-the-art algorithms operating on PCM data when tested on standard PDM sampling-rates of 2 MHz. Moreover, we show that the SSM's output can be downsampled by more than 65,000 times, thus significantly reducing the number of processing timesteps in downstream layers.

0.17