CS Paper Radar

An Ultra-Low-Noise Tunable TIA in 45nm Silicon Photonics for Electro-Optical Ultrasound Data Acquisition

Marziyeh Rezaei, Sridhar Singhal, Alp A. Derin, Soner Sonmezoglu, Sajjad Moazeni

eess.SP eess.SY ·submitted 2026-11-06 00:30 UTC · v1
unusual

Abstract

This paper presents the design and experimental characterization of a 32-channel, WDM-compatible electronic-photonic receiver array fabricated in the GlobalFoundries 45nm monolithic silicon photonics process. Optimized for miniaturized, millimeter-scale electro-optical ultrasound data acquisition probes for broadband photo-acoustic imaging (PAI), the chip utilizes integrated micro-ring resonator (MRR) demultiplexers and photodiode (PD) arrays to decode multi-wavelength acoustic signals outside the body. This work focuses specifically on the comprehensive characterization of the receiver front-end, evaluating both the optical WDM filter bank and the transimpedance amplifier (TIA) performance. Monolithic co-integration minimizes critical photodiode-to-TIA interface parasitics. The TIA incorporates a DC-offset cancellation loop that compensates for photodiode-induced offset currents while providing tunable low-frequency cutoff control over a range of 30 kHz to 1.5 MHz. This tunability enables effective suppression of flicker noise and improves overall signal integrity. The front-end achieves the peak transimpedance gain of 144 dB$Ω$ while maintaining an ultra-low input-referred noise current density of $1\text{ pA}/\sqrt{\text{Hz}}$, demonstrating a highly scalable architecture for high-sensitivity intravascular and endobronchial imaging.

Closest papers

Nearest neighbours by meaning across the whole index.

Modeling and Design of a Diaphragm-Integrated Photonic Waveguide Microphone

eess.AS ·2026-10-13 ·Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall
benchmark similarity 0.51
Abstract · 14 pages

Can an integrated optical readout improve the useful operating range of a miniature microphone? We address this question with an analytical model of a diaphragm carrying the sensing arm of a Mach-Zehnder interferometer (MZI). The model links pressure-induced bending to waveguide elongation and then to photocurrent, allowing mechanical sensitivity and optical detection limits to be assessed separately. Optical shot noise and back-cavity thermomechanical noise set the pressure resolution, while a 10% total harmonic distortion criterion defines acoustic overload. Two operating regimes are examined: a compact MEMS microphone with 1 mW optical input and a measurement microphone with 100 mW optical input. For the compact case, a 1 mm diameter, 1 micrometer thick, stress-free silicon diaphragm and 100% modulation efficiency give a predicted signal-to-noise ratio of 78 dB and acoustic overload pressure of 124 dB. The higher-power case lowers the modeled noise floor and increases dynamic range relative to the selected measurement microphone benchmark. These estimates rely on favorable assumptions and do not establish a substantial overall advantage in conventional microphone applications. Remote optical interrogation offers a separate motivation for harsh-environment sensing, but the temperature tolerance of the proposed sensing head remains unverified. The analysis identifies the design tradeoffs and measurements needed to test the predicted performance.

0.09

A Reconfigurable Pipelined-SAR ADC with Embedded Compression for Temporal Compressed-Sensing Ultrasound Imaging

eess.SP physics.med-ph ·2026-08-28 ·Reza Pakdaman Zangabad, Xitie Zhang, Levent Degertekin, Shaolan Li
similarity 0.49
Abstract · 15 pages, 11 figures, Journal

Compact ultrasound imaging systems are increasingly constrained by receiver-side sampling, conversion, memory, and data-transfer requirements. This work presents a compressed-sensing pipelined successive-approximation-register analog-to-digital converter (CS-SAR ADC) for acquisition-side temporal compression of pre-beamformed medical ultrasound radio-frequency (RF) data. Pseudo-random polarity modulation and charge-domain accumulation are embedded in the SAR sampling network so that multiple consecutive RF samples are encoded into one measurement before quantization, supporting temporal compression ratios of $N_{cT}=1$, 2, and 4. The compressed outputs are recovered off chip using a probe-specific pulse-dictionary RF model and then processed with conventional ultrasound beamforming. A 65-nm CMOS prototype was measured with a 1.2-V supply and 50-MHz master clock. In the non-compressed mode, it operates at 10 MS/s, consumes 964.49~$μ$W, and achieves 44.12-dB SNDR and 56.40-dB SFDR for a 7.7-kHz input. The ADC output rates decrease to 5 MS/s and 2.5 MS/s for $N_{cT}=2$ and 4. Across all evaluated RF traces, median NCC values were 0.981 and 0.932, with median NRMSE values of 0.36 and 0.56, respectively. Wire-phantom localization error remained below 0.04 mm with no appreciable FWHM degradation. In the speckle-rich cyst phantom, SSIM remained 0.94 and 0.87, while CNR decreased from 3.534 in the reference to 2.047 and 1.379. These results demonstrate a hardware-realistic tradeoff in which temporal compression substantially reduces ADC conversion count and output data rate while preserving point-target geometry, whereas low-contrast cyst conspicuity is more compression-sensitive.

0.28

A Time-Encoded Analog Photonic Interposer for Energy-EfficientIntegration of Analog Vision Sensors and Analog Accelerators

cs.AR ·2026-09-02 ·Subhradip Chakraborty, Zihan Yin, Xuming Chen, Chengwei Zhou, Gourav Datta +1 more
similarity 0.49
Abstract

This work introduces a time-encoded analog photonic interposer that enables long-distance, high-fidelity transport of analog signals between spatially separated chiplets. Unlike prior silicon-photonic links limited to digital data, the interposer preserves analog information by converting amplitudes into timing intervals using an analog-to-time converter (ATC), transmitting them over a wavelength-division-multiplexed photonic link, and reconstructing values at the receiver without an explicit high-precision ADC/DAC data-converter pipeline. The link instead embeds an implicit 6-bit time-domain quantization and uses a single wavelength per processing element independent of bit precision. Evaluated in a fully analog vision pipeline with an in-pixel computing (IPC) sensor, it achieves a 2.04x energy--delay product (EDP) improvement over an 8-bit digital electrical baseline on the 560x560 Visual Wake Words dataset, with the advantage widening with link length even against a precision-matched 6-bit baseline. The pipeline holds 89.87% and 86.15% accuracy on ResNet18 and MobileNetV2 for VWW and generalizes across CIFAR-10 and ModelNet40 within 2% of the digital baseline.

0.26

Performance Analysis and Design of an Optomechanical Microphone Using an Integrated Photonic Waveguide Interferometer

eess.AS eess.SYphysics.app-ph ·2026-09-21 ·Xiaoyu Niu, Yuqi Meng, Zihuan Liu, Ehsan Vatankhah, Neal Hall
unusual similarity 0.48
Abstract · 16 pages, 12 figures, 1 table

We present an optomechanical microphone based on a diaphragm-integrated photonic waveguide Mach-Zehnder interferometer. Acoustic pressure deforms the MEMS diaphragm, inducing strain in the sensing waveguide and changing its optical path length. We analytically evaluate the optical and mechanical transduction mechanisms and key figures of merit, including signal-to-noise ratio, dynamic range, acoustic overload pressure, and minimum detectable pressure. Two design cases are considered: a MEMS microphone and a measurement microphone. The results indicate competitive performance but no substantial overall advantage over state-of-the-art microphones in conventional applications. The architecture may nevertheless offer advantages for high-temperature and other harsh-environment sensing applications.

0.30

Adaptive carrier signal synthesis for frequency-division multiplexed cryogenic detector readout

eess.SP physics.ins-det ·2026-11-12 ·Timo Muscheid, Benedikt Keppner, Daniel Crovo, Robert Gartmann, Marvin Fuchs +3 more
unusual similarity 0.47
Abstract · TWEPP26 Proceedings

Frequency-domain multiplexing is a fundamental technology for readout of cryogenic detector arrays on a single transmission line. Synthesizing a large number of static carrier tones for resonator stimulation eventually drives the cryogenic low-noise amplifier beyond its P1dB, introducing detector signal distortion. Scaling array sizes to O(10^6) detector pixels therefore demands minimizing the total power on the transmission line by continuous tracking of the resonances, which requires the readout electronics to be capable of updating the carrier tones dynamically. This work presents an scalable FPGA-based implementation for carrier signal synthesis based on a numerically controlled oscillator and a polyphase filter bank, enabling real-time frequency adaptivity as well as frequency resolution of 4 mHz to precisely tune the operating point, while simultaneously reducing resource usage compared to the current memory-based implementation.

0.25

U-Sonic: An Open-Source 8-Channel Ultrasound Transmit IP in a 130 nm RISC-V SoC

cs.AR eess.SP ·2026-10-01 ·Federico Villani, Nico Canzani, Marc-André Wessner, Philippe Sauter, Enrico Zelioli +3 more
published similarity 0.46
Abstract · 4 pages, 3 figures, 3 tables. This work has been accepted for publication in the 2026 IEEE International Ultrasonics Symposium (IUS) proceed…

Miniaturized ultrasound (US) probes require programmable and synchronized transmit (TX) excitation across multiple elements, while existing compact platforms often rely on limited microcontroller (MCU) pulse generators or closed-source fixed-function pulser devices. We present U-Sonic, an open-source digital US TX peripheral integrated into a 32-bit RISC-V system-on-chip (SoC). The implemented SoC integrates 8 pulser cores, while the parameterized architecture supports up to 16 channels. Each core generates single- or dual-tone bursts with programmable period, duty cycle, pulse count, polarity, and idle level, together with optional inverted stop pulses for active damping. A shared memory-mapped Open Bus Interface (OBI) enables synchronous start and stop of arbitrary channel subsets and supports composite bipolar, gated, and three-level excitation schemes. Functional correctness was verified in Verilator against a Python golden model over 4379 checked cycles across directed and randomized configurations, and confirmed on a Terasic DE10-Lite field-programmable gate array (FPGA). The design was synthesized and placed-and-routed in IHP 130 nm. The post-layout area in kilo gate equivalents (kGE), scales as 1.65 kGE plus 1.66 kGE per channel. The 8-channel instance occupies 14.9 kGE, corresponding to approximately 14.3% of the 104 kGE SoC. The register-transfer level (RTL), register descriptions, verification collateral, and software support are released as open source.

0.50

Analog Pin Directionality as an Exfiltration Attack Surface in Mixed-Signal ICs

cs.CR cs.AR ·2026-09-16 ·Ramana Ranganatham, Chirag Adiga, Michael Zuzak, Tejasvi Das
similarity 0.46
Abstract · Submitted to IEEE Transactions on Information Forensics and Security (TIFS)

Mixed-signal SoCs rely on nominally input-only analog pins to acquire off-chip signals, but the directionality of these interfaces is generally treated as a functional property rather than explicitly verified as a security property. This work identifies and experimentally demonstrates a directionality-based class of analog and mixed-signal (AMS) exfiltration attacks in which data-dependent circuit-offset modulation converts a nominally input-only pin into an outbound information channel. We analytically model the attack mechanism and identify three enabling host conditions: a closed-loop amplifier, an exposed amplifier input, and sufficiently high impedance at that pin. This attack class is validated through a representative silicon case study using a photoplethysmography (PPG) analog front-end (AFE) fabricated in a commercial 55-nm CMOS process. The payload incurs $<$0.001\% area overhead relative to typical biosensing AFEs. Under the evaluated conditions, payload activation reduces the filtered PPG-output SNR by only 0.03~dB, while the maximum HT-induced perturbation of 5.9\% of the PPG amplitude remains within the 34.3\% benign variation at the exposed sensor-input pin across process and temperature. The raw exfiltration SINR remains below -20~dB, while targeted filtering increases it above 14~dB and enables signal recovery. Silicon measurements demonstrate data exfiltration through the input pin at bit rates up to 10~kbps and error-free recovery of a PRBS message. These results expose a conventional test-observability gap and establish analog pin directionality as an AMS security property requiring explicit verification, test coverage, and defense rather than being inferred from nominal signal flow.

0.30

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.45
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35