CS Paper Radar

The Hearpiece Database of Binaural Room Impulse Responses and Driver Responses on KEMAR

Tong Xiao, Reinhild Roden, Matthias Blau, Simon Doclo

eess.AS ·submitted 2026-11-04 11:05 UTC · v1

Abstract

This document describes the measurement setup, signal processing, data organization, and MATLAB file format of a database of acoustic responses measured on a Knowles Electronics Manikin for Acoustic Research (KEMAR) using the Hearpiece, a multi-microphone, multi-driver in-ear research device. The data include binaural room impulse responses (BRIRs) and Hearpiece driver responses, together with center-microphone room impulse responses and a loopback impulse response of the playback and recording system. The BRIRs cover two Hearpiece configurations, three room conditions, three independent insertions per configuration, and 24 horizontal source directions. The database supports reproducible research on binaural and hearing-device signal processing, with potential applications in speech enhancement, spatial filtering and source separation, dereverberation, active noise and occlusion control, and acoustic feedback cancellation. The database, MATLAB loading script, and technical documentation are publicly available at https://doi.org/10.5281/zenodo.23667308.

Comment
13 pages, 7 figures, 5 tables. Database and MATLAB loading script available at https://doi.org/10.5281/zenodo.23667308

Closest papers

Nearest neighbours by meaning across the whole index.

ARPEGE: Dataset and Methods to Estimate Acoustic and Geometric Parameters of Rooms from Sound

cs.SD eess.AS ·2026-10-30 ·Jean-Daniel Pascal Prieto, Prerak Srivastava, Cédric Foy, Antoine Deleforge
dataset similarity 0.61
Abstract

Can one hear the walls of a room? To foster audio signal processing research around this question we release ARPEGE, a dataset containing hundreds of ambisonic spherical-array room impulse responses recorded in 6 empty rooms, annotated by the relative positions of sources, microphones and all acoustic reflectors. The dataset includes multiple room sizes, surface materials, orientations and distances, as well as recordings of human speakers and handclaps. Two state-of-the-art methods on image source localization and blind room parameter estimation are demonstrated on the data. Initial code for re-simulating the measured room impulse responses is provided, a longer term goal being to digitally twin the dataset.

0.58

A Device to Control and Manipulate Occlusion Effects for Own Voice Perception Studies

eess.AS ·2026-09-11 ·Rouben Rehman, Simon Kersten, Aron Schliep, Janina Fels
similarity 0.60
Abstract

The occlusion effect (OE) refers to changes of the eardrum sound pressure through ear canal occlusion. It consists of two phenomena: an insertion loss (IL) attenuating air-conducted sounds, and an occlusion gain (OG) amplifying bone-conduction. Perceptual research on this is hindered by high variability of the OE across individuals, complicating repeatable presentation of precise OE conditions. Consequently, a method to control OE conditions reproducibly during perceptual experiments is needed. For such investigations, the system must enable separate control of IL and OG. We present an approach based on modified commercial earmuffs with integrated microphones. The design integrates dedicated impedance measurements and the derivation of digital filters, which are applied to the microphone signals to emulate arbitrary OE curves. The system is evaluated objectively through appropriate measurements. Results show that the headphones' inherent OG is guaranteed to be below 6dB above 115Hz, falling below 0dB above 155Hz. Emulation is shown to work accurately over the entire frequency range of interest. Limitations arise mainly due to a slight residual inherent OG for deep voices and the processing delay of the system. Future work will focus on the perceptual evaluation of the system and its application in perceptual studies.

0.20

Reproduction of Simulated Acoustics Scenes Using Acoustics Room Transformer for speech intelligibility tests in Clinics

eess.AS physics.med-ph ·2026-11-13 ·Ali Fallah, Kirsten C Wagener, Pascal Pflueger, Steven van de Par
similarity 0.56
Abstract · This paper is submitted to Acta Acustica and is currently under review

An Acoustic Room Transformation (ART) method is proposed for clinical applications to render simulated acoustic environments using six loudspeakers in a reverberant room. In typical clinical settings, testing rooms are not acoustically treated and only a limited number of loudspeakers are available. The ART approach enables control of the playback-room reverberation, allowing speech intelligibility tests to be performed under realistic and perceptually compensated conditions. The method focuses on the two most common Speech Reception Threshold (SRT) configurations: S0N90 and S0N90. One front and one side loudspeaker reproduce the direct sound components, while the remaining four loudspeakers (two in front and two behind the listener) generate the reverberant sound field. The direct sound is optimized in terms of energy, and the reverberant field is adjusted based on both energy and interaural coherence. An additional direct-sound gain is applied to match the clarity index (C50) of the reproduced signals to that of the reference target. Results from speech intelligibility tests demonstrate that, with ART processing, the reproduced scenarios achieve SRT values very close to those of the reference signal in both S0N0 and S0N90 conditions and therefore allow for comparable speech test results independent of the particular test room acoustics.

0.27

Active noise cancellation extends the benefit of AI speech enhancement in real hearing-aid recordings

eess.AS ·2026-10-12 ·Andrew T. Sabin, Linkai Li
similarity 0.56
Abstract · 8 pages, 5 figures, 1 table

Active noise cancellation (ANC) is common in headphones but rare in hearing aids, and its value for understanding speech in noise is not established. Algorithms that improve signal-to-noise ratio (SNR) act only on the hearing aid's amplified path, while unprocessed sound also reaches the eardrum directly through the vent, limiting the SNR improvement that is realized. Our earlier simulations predicted that attenuating this direct path with ANC would substantially increase the benefit of such processing. We tested that prediction in three hardware conditions: a standard receiver-in-canal (RIC) hearing aid, and an ANC-capable RIC with ANC off and on. Each was fit to NAL-NL2 targets for an N3 hearing loss and recorded on KEMAR with an AI speech-enhancement algorithm (AI-SE) off and on, in seven realistic scenes above 70 dB SPL. Speech and noise spectra were estimated from each recording with a binary time-frequency mask derived from the clean speech. AI-SE produced a similar peak benefit of about 4 dB in the high frequencies in all three conditions, but that benefit stayed at or above 1 dB only above 1500, 600, and 130 Hz for the standard RIC, ANC RIC (ANC off), and ANC RIC (ANC on), respectively, closely tracking the measured attenuation of the direct path. With AI-SE on, ANC RIC (ANC on) improved SII-weighted SNR by 5.1 dB relative to the open ear, compared with 3.3 dB for ANC RIC (ANC off) and 1.6 dB for the standard RIC. With AI-SE off, enabling ANC added only 0.2 dB. ANC is therefore an enabling technology: on its own it added little, but by attenuating the direct path it allowed SNR-enhancing processing to deliver substantially greater benefit at the eardrum, extending that benefit to much lower frequencies.

0.21

A Novel Binaural Cue Preservation Loss for DNN-Based Binaural Speech Enhancement

eess.AS cs.SD ·2026-08-17 ·Jayteerth Amble, Thomas Haubner, Hendrik Schröter, Christoph Hoog Antink, Henning Puder
similarity 0.55
Abstract · Accepted at the International Workshop on Acoustic Signal Enhancement (IWAENC) 2026

Binaural speech enhancement for hearing aids aims to reduce noise while preserving the interaural cues needed for spatial localization. Although deep neural network-based methods achieve strong noise reduction, they often distort the rela- tionship between the left and right signals. In this paper, we propose two novel binaural cue preservation losses. First, a binaural reconstruction error loss that directly penalizes masking-induced distortion in the relationship between the left and right spectra, providing a more direct measure of the binaural consistency than conventional separate interaural level differences (ILD) and interaural phase differences (IPD) errors as in prior work. Second, a binaural cue loss that jointly models ILD and IPD to better preserve the binaural structure. Experimental results show that both proposed losses maintain strong noise reduction performance and reduce masking- induced distortion compared to the state-of-the-art baseline cue loss, while the second proposed joint binaural cue loss also outperforms the baseline in ILD preservation.

0.22

Bin2Ambi: Learning Ambisonic Soundfield Reconstruction from Head-Tracked Binaural Audio

eess.AS ·2026-09-30 ·Gavin Milner, Nils Peters
similarity 0.54
Abstract

User-generated content has become one of the most-consumed content types. However, capturing spatial audio with consumer hardware is still challenging. Given the widespread success of smart earbuds, binaural audio could be a promising option to capture spatial audio on consumer devices, but its inherent signal characteristic limits its usability as a recording format. In this paper, we propose and define a new task, Binaural to Ambisonics conversion (Bin2Ambi). In our proposed system, we exploit simultaneously captured head-tracking data provided from the motion sensors in smart earbuds. We show that this motion data help resolve the inherent directional uncertainty of two-channel binaural audio due to front-back localization ambiguities and lateral errors in the cone of confusion. Our results show that our system learns directional and diffuse-field information and that head-tracking especially reduces extreme localization errors. Objective metrics and a subjective listening test suggest that the converted Ambisonics soundfield achieves an average directional error of up to $11.8^\circ$ and a perceived spatial quality similar to a DirAC ground-truth model. The proposed algorithm can serve as a baseline for future improvements to this novel Bin2Ambi task.

0.23

Sensing Bone-Conducted Speech with Earbuds

eess.AS ·2026-09-02 ·Christoph Weyer, Peter Jax
published similarity 0.54
Abstract · 14 pages, 12 figures, journal

Clear capture of the wearer's own voice (OV) is essential when using earbuds for mobile communication. However, OV capture remains challenging in noisy environments. Bone-conducted (BC) speech, which can be sensed as vibrations of the earbud housing, can be used to improve OV capture. However, neither bandwidth nor spatial characteristics of OV-induced earbud vibrations have been analyzed in detail, despite both characteristics being relevant, e.g., for sensor choice and placement. This study investigates both characteristics, based on measurements with two earbud models. Spectrally, results indicate that OV-induced earbud vibrations exhibit a low-pass characteristic, with a steep roll-off of -93 dB per decade above 400 Hz. Thus, sensors with comparatively low noise floors are required to sense the vibrations above \SI{1}{\kilo\hertz}. Spatially, results indicate that the earbuds mainly vibrate in and out of the ear canal entrance, with high consistency between subjects and fits. Simulations confirm that this enables capture of the high-power vibrations below 400 Hz by a single-axis sensor with less than 1.5 dB mean attenuation.

0.39

Echo Detection in Spatial Room Impulse Responses Measured with Spherical Microphone Arrays Using the Herglotz Wavefunction

eess.AS ·2026-09-23 ·Pierre Massé, Anthony Gallien, Wolfgang Kreuzer, Markus Noisternig
similarity 0.54
Abstract · 15 pages, 10 figures, 4 tables

Early reflections in spatial room impulse responses (SRIRs) measured using spherical microphone arrays (SMAs) play an important role in spatial audio analysis, rendering, and reverberation modeling. Their accurate localization and characterization can facilitate the analysis, processing, and manipulation of measured reverberation fields. This paper proposes a method for detecting and characterizing early reflections based on the Herglotz wavefunction formalism. The measured sound field is represented as a continuous superposition of incident plane waves, from which a localization function is derived in the spherical harmonic domain. An adaptive radial Gaussian fitting procedure is then used to estimate both the directions of arrival (DoAs) and the number of incident reflections within a single analysis frame. The proposed framework is evaluated using simulated and measured SRIRs and compared with conventional steered response power (SRP) and multiple signal classification (MUSIC) localization methods. The results demonstrate improved localization accuracy and more reliable detection of multiple simultaneous reflections, highlighting the potential of the proposed Herglotz-based formulation for the analysis of early reflections in SMA-measured SRIRs.

0.29