CS Paper Radar

Reliability- and Anatomy-Consistency-Aware Multimodal Learning for Robust Fracture Classification from Bangladeshi Radiographs

Musa Tur Farazi, K G Subarno Bithi

eess.IV cs.AIcs.CV ·submitted 2026-08-21 09:41 UTC · v1
hot direction

Abstract

Background: Multimodal fracture classifiers may benefit from patient and anatomical metadata, but they can also become brittle when contextual information is missing or mismatched. Methods: We studied 1493 radiographs from the Bangladeshi OrthoFrac-XR dataset using leakage-safe age, sex, bone type, and laterality. A ConvNeXt image encoder was combined with a clinical multilayer perceptron through concatenation, late fusion, reliability-gated residual fusion, and a hierarchical state-location formulation. We additionally introduced an anatomy-consistency gate that attenuates metadata corrections when an image-side anatomical prediction disagrees with the reported bone type. Results: Across five folds and three seeds, hierarchical residual fusion achieved a macro-F1 of 0.6046 +/- 0.0279, compared with 0.5727 +/- 0.0270 for image-only learning, while improving the Brier score from 0.5239 to 0.4948. In a five-fold robustness experiment, anatomy-consistency fusion reduced the macro-F1 loss under shuffled metadata from 0.0567 to 0.0203 relative to ordinary residual fusion, although its clean-data macro-F1 was lower. Without bone type at inference, auxiliary anatomy supervision improved macro-F1 from 0.5620 +/- 0.0330 to 0.5899 +/- 0.0289. Conclusions: Structured context improves fracture classification, and consistency-aware gating limits harm from mismatched metadata. The observed clean-performance-robustness trade-off and the absence of patient-level identifiers motivate external and prospective validation.

Closest papers

Nearest neighbours by meaning across the whole index.

Patient-Level, Leakage-Aware Deep Learning for Cross-Center Periapical Radiograph Classification

cs.CV ·2026-09-13 ·Md Jubaer Rahman, Ulas Bagci
benchmark similarity 0.65
Abstract · Submitted to the 9th International Conference on Signal Processing and Information Security (ICSPIS 2026)

Dental caries and endodontic disease are among the most common health conditions worldwide, and intraoral periapical radiographs are central to their detection, treatment planning, and follow-up. Automated tooth-level classification of these images, however, lacks reproducible benchmarks, is often evaluated with image-level splits that leak patients between training and test, and is rarely validated across clinics. This paper presents the first patient-level, leakage-aware classification benchmark for single-tooth intraoral periapical radiographs on the DentIRO dataset, which comprises 5,300 images from 3,243 patients across two clinics and four classes: Healthy, Caries, Crowned, and Root Canal. Five transfer-learning models are compared with patient-grouped stratified cross-validation, so that every patient remains within a single fold. DenseNet121 gave the strongest and most stable result at a mean macro-F1 of 0.9787, while the four ImageNet-initialized backbones performed comparably. A controlled comparison on a fixed architecture showed that chest-radiograph pretraining transferred less effectively than ImageNet initialization. Bidirectional cross-center validation produced a small average generalization gap of 0.0077, and Grad-CAM confirmed that predictions rely on clinically meaningful tooth regions rather than acquisition artifacts. The benchmark offers a rigorous and reproducible baseline for intraoral radiograph classification.

0.29

Masked Privileged-Information Distillation for Multimodal Skin Lesion Classification Under Missing Clinical Metadata

cs.CV cs.LG ·2026-10-02 ·Anirban Barua, Md Mahir Abrar Khan, Ayman Iktidar, Md. Sajjatul Islam
similarity 0.63
Abstract

Multimodal skin lesion classification combines clinical images with patient metadata to improve diagnostic accuracy. However, complete metadata available during training may be only partially accessible at deployment, and resource-constrained settings additionally require computational efficiency. We address these challenges with a privileged-information distillation framework in which a multimodal teacher trained on complete metadata supervises a 9.2x smaller student trained with randomly masked clinical fields. Clinical fields are masked as whole groups at a per-sample rate drawn from U(0,1), so one training run covers the full metadata availability range. Fusion is residual, with metadata added as a gated correction to an unconditional image base. On the PAD-UFES-20 dataset, distillation under masked training improves balanced accuracy over cross-entropy training at every availability level, by an average of +4.7 points versus +1.8 points without masking. The masked student loses only 7.8 balanced-accuracy points as metadata decreases from complete to absent, compared with 36.6 points for the same student trained on complete metadata, highlighting the role of masked training in graceful degradation beyond distillation alone. Grad-CAM visualizations further show that the masked student's attention generally remains lesion-centered as metadata is withdrawn. The resulting compact model targets point-of-care settings, where clinical metadata is often incomplete.

0.23

FRAC-MAS: A Safe and Explainable Multi-Agent System for Fracture Diagnosis

cs.AI ·2026-08-22 ·Hardik Iyer, Tirath Bhathawala, Mihir Panchal, Ying-Jung Chen, Kiran Bhowmick +2 more
publishedcode/data similarity 0.62
Abstract · Medical Image Computing and Computer Assisted Intervention (MICCAI) 2nd Workshop on Agentic AI for Medicine (AgenticMed)

Fracture detection and its clinical interpretability see notable improvements when deep vision models are integrated with agentic AI architectures. While deep learning models achieve high diagnostic performance, their black-box nature limits clinical adoption. We propose FRAC-MAS, an agentic AI system for automated, explainable, and safe bone fracture detection. The framework combines a stacked ensemble of four vision models with conformal prediction to produce statistically grounded differential diagnoses, while a multi-agent workflow performs independent verification, retrieves clinical guidelines, and generates patient-friendly reports. A pipeline-depth ablation study confirms that our multi-agent critic triages 86.6% of cases into a high-confidence auto-confirmed cohort while escalating uncertain cases, outperforming a single-agent baseline. Patient preference studies against Llama, MedGemma, and Gemini further demonstrate significantly more comprehensible clinical reports. These results suggest that integrating multi-agent critics with conformal guarantees enables safer radiology triage while preserving clinician oversight. More broadly, FRAC-MAS demonstrates how cooperative agentic architectures can serve as auditable, human-in-the-loop decision support systems for safety-critical healthcare. Our code is available at https://github.com/hardik1712/FRAC-MAS, and the website is available at https://frac-mas.vercel.app.

0.41

Integrating Local Detail and Global Context: A Dual-Input Multi-Task Learning Framework for Bone Tumor Diagnosis

eess.IV cs.CV ·2026-09-23 ·S. M. Nasif Uddin, Rusab Sarmun, Muhammad E. H. Chowdhury, Adam Mushtak, Israa Al-Hashimi +1 more
similarity 0.62
Abstract

Primary bone tumors are rare but clinically aggressive neoplasms whose diagnosis from radiographs is challenged by heterogeneous morphology, subtle lesion margins, and overlapping bone structures. To address the limitations of existing single-view models, we present a dual-input, multi-task learning framework that, to our knowledge, is the first to apply bidirectional cross-modal attention between a lesion crop and the full radiograph for joint segmentation and subtype classification. Using the multi-institutional Bone Tumor X-ray Radiograph Dataset (BTXRD, n=3,746), we employ a YOLO-based detector to generate regions of interest, which are paired with full images as inputs to a dual-stream DenseNet121 architecture. Features are integrated via a novel cross-modal attention fusion strategy, refined by Hierarchical Multi-scale Feature Fusion, effectively balancing fine-grained lesion detail with global anatomical context. Evaluated on a held-out patient-level test split, the model demonstrates superior performance over single-input baselines, achieving an overall Dice Similarity Coefficient of 0.896 and a macro-averaged classification F1-score of 0.928. Notably, the system exhibits exceptional sensitivity for malignant osteosarcoma (AUC 0.999), validating the potential of dual-stream context modeling to support radiologists in accurate, early decision-making.

0.20

MIRROR: Multimodal Intelligent Radiology Reasoning and Observation Reporter

cs.CV cs.AIcs.LG ·2026-08-17 ·Vignesh Nagarajan, Sriram Venkatapathy
hot direction similarity 0.61
Abstract · 8 pages, 5 figures, 5 tables, 24 references

A radiologist reading a model's output faces two problems. The model returns a number and no reason, and any system that turns that number into readable prose can quietly add claims the model never made. MIRROR is a research prototype built to separate those failures. It chains a multi-label classifier, a Grad-CAM localizer that turns each positive finding into a named anatomical region, and a report writer that receives the labels, probabilities, and regions but never the image. Because the language layer cannot see pixels, it cannot assert a finding the classifier did not make. We are precise about what that buys: a MIRROR report's findings are auditable against the probability vector, while the sentences framing them are ordinary generated text, and we show one stating a cardiothoracic ratio the system never measured. One registry holds the taxonomy, anatomy, and phrasing for chest X-ray, brain MRI, and head CT, so adding a modality is a data change; all three are routed and tested, one is trained. On ChestMNIST that classifier reaches macro AUROC 0.729 and ranks better than chance on all 14 labels, at 1.6 to 6.8 times the precision a random ranker would get. Yet at the default 0.5 threshold it emits no positive prediction at all for 11 of them, and its excellent-looking Brier score of 0.045 sits beside the 0.047 earned by a predictor that ignores the image. The discrimination is real; the decisions are not. Under the class imbalance normal in radiology, aggregate metrics flatter models that do nothing, and should be reported against that floor.

0.32

Cracks in Embeddings: Robustness and Stability of JEPA-Based Chest X-Ray Representations

cs.CV ·2026-11-13 ·Zahid Mansur, Kalpana Yadav, Deepak Mishra
similarity 0.61
Abstract

Self-supervised Joint Embedding Predictive Architecture (JEPA) models are increasingly used for medical imaging, however there is a limited understanding about robustness of these models toward real-world image changes. We test four JEPA-based chest X-ray encoders, trained on 78,468 NIH ChestX-ray14 images, under six tests: two black-box adversarial attacks (SPSA, Boundary Attack), three image corruptions (Gaussian noise, brightness shift, contrast shift), and a label-scarcity test, measuring embedding change and classification AUROC. These perturbations cause severe, model-dependent damage: encoder-level Cosine Similarity drops as low as 0.33, and AUROC falls by as much as 0.12 in the worst case (I-JEPA under the Boundary Test). We test two ways of training the small predictor on top of each frozen encoder to address this. Adversarial fine-tuning, trained on clean and perturbed images together, raises embedding consistency above 0.97 in nearly every case and improves AUROC, relative to the same perturbed baseline, for most models, with the largest gain of $+0.10$ on I-JEPA. A Vector-Quantized codebook method, trained only on clean images and evaluated on perturbed test images for the first time, instead degrades under distortion for all four models, most noticeably for I-JEPA ($-0.15$ AUROC on average), showing that its discrete bottleneck alone does not provide the robustness that comes from training on perturbed data directly.

0.25

M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Models

cs.CV ·2026-09-27 ·Sathiyamohan Nishankar, Pubudu Sanjeewani, Asanka Perera
similarity 0.61
Abstract

Quantitative evaluation of generative models for radiology remains challenging. Clinically relevant structures are often small and infrequent, feature spaces learned from natural images may represent them poorly, and a single summary score cannot distinguish limited fidelity from limited diversity. This study proposes the Medical Multi-axis Maximum Mean Discrepancy score (M3-Score), an evaluation framework based on RadioDINO-s16, a frozen vision transformer pretrained on radiology images. M3-Score reports three complementary axes computed at pre-specified encoder depths: \emph{fidelity}, measured by an unbiased multi-bandwidth radial basis function (RBF) MMD$^2$ at the final block; \emph{memorization}, measured by nearest-neighbor distances at 75\% depth; and \emph{coverage}, defined as the fraction of real images with a generated neighbor within their $k$-nearest-neighbor radius at 33\% depth. Reference sets are sampled across subjects to limit the influence of correlated slices. On BraTS brain MRI, the fidelity axis ordered five comparison sets of increasing severity (Spearman $ρ= 1.00$), and a subject-disjoint real set yielded $\mathrm{MMD}^2 = 0$ (permutation $p = 1$). An unconditional denoising diffusion probabilistic model achieved $\mathrm{MMD}^2 = 0.073$ (95\% confidence interval $[0.071, 0.080]$) but covered only 38\% of the real distribution. Under progressive mode dropping, $k$-NN manifold recall increased at all twelve encoder blocks, whereas the proposed coverage estimator decreased monotonically ($ρ= -1.00$). RadioDINO-s16 features separated real brain MRI from generated samples with a ROC-AUC of 0.819, compared with 0.555 for InceptionV3 and 0.582 for CLIP. Across a twentyfold range of sample sizes, the mean M3 value varied by a factor of 1.05, compared with 2.52 for the Fréchet Inception Distance.

0.21

Domain-Adversarial Adaptation from MURA to In-House Radiographs for Improved Adult Elbow Fracture Classification

cs.CV ·2026-11-09 ·M. Bolhassani, W. Furtado, D. Duvall, MJ Negahdar, J. Joshi +2 more
published similarity 0.61
Abstract · 4 pages, 3 figures, Accepted and presented on SPIE Medical Imaging 2026

We studied domain shift in adult elbow fracture classification from radiographs when training on a large public dataset and deploying on a small, institution-specific dataset (UofL). We implemented a domain-adversarial neural network (DANN) to align feature distributions across source (MURA) and target (UofL) domains while optimizing fracture classification. A pretrained convolutional backbone was adapted to grayscale inputs; the task head predicts fracture presence, and a gradient-reversal-based domain head encourages domain-invariant features via adversarial learning. We compared four settings: (1) Source-only, (2) Target-only (limited labels), (3) Naive merge (pooled training), and (4) DANN (MURA to UofL). Evaluation on UofL test data uses AUC-ROC, and accuracy. DANN outperformed Source-only and Naive merge baselines by reducing domain bias without overfitting to the small target set. Ablations showed that progressive adversarial weight, dataset-size-aware domain loss, and domain-balanced sampling improved stability and target performance. Results demonstrated that domain alignment is a practical path to robust clinical generalization from public to local data.

0.40