CS Paper Radar

Improving O-RADS Risk Stratification from Ultrasound Reports: A Comparative Evaluation of Hybrid versus End-to-End LLM Reasoning Strategies

Xiaotong Tan, Chunli Qiu, Xin Liu, Qing Huang, Guangli Zhou, Bo Gao, Xiaoyan Song, Shuyan Wang, Xiuqin Wang, Wufeng Xue, Ruobing Huang, Dong Ni, Guowei Tao, Jun Cheng

cs.AI ·submitted 2026-08-24 10:04 UTC · v1

Abstract

Background: Automating clinical guideline-based decision-making with large language models (LLMs) remains challenging because of reliability, hallucination, and limited interpretability. We compared the performance of LLMs and reasoning strategies for automated Ovarian-Adnexal Reporting and Data System (O-RADS) classification from free-text pelvic ultrasound reports. Methods: In this retrospective study, consecutive patients with ovarian masses who underwent pelvic ultrasound were included. Eight LLMs were tested with three reasoning strategies: implicit-knowledge end-to-end, rule-informed end-to-end, and a feature-based hybrid architecture that decoupled feature extraction from rule-based classification. The reference standard was O-RADS categorization established by expert consensus. Results: A total of 310 women with 390 ovarian masses were evaluated. The feature-based hybrid architecture using Gemini 3.6 Flash demonstrated the best performance, achieving an accuracy of 99.2% (387 of 390) and almost perfect agreement with the reference standard (weighted kappa = 1.00; 95% CI: 0.99-1.00). Its performance surpassed that of original clinical reports (accuracy, 87.7% [342 of 390]; weighted kappa = 0.94; 95% CI: 0.91-0.96) and end-to-end LLM strategies (accuracy range, 65.6% [256 of 390] to 95.9% [374 of 390]). For structured feature extraction, Gemini 3.6 Flash demonstrated higher overall accuracy than Claude Fable 5 (98.9% vs 97.8%; P < 0.001). The hybrid architecture reduced misclassification errors and mitigated the overstaging tendency observed in original reports. Conclusion: The feature-based hybrid LLM architecture that separates clinical feature extraction from deterministic guideline execution enables highly accurate, reliable, and interpretable automated O-RADS classification, providing a promising approach for standardized, guideline-based clinical decision-making.

Comment
Main manuscript: 20 pages, 5 figures, and 2 tables; supplemental material: 11 pages, 1 figure, and 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

A Concept-informed Interpretable Artificial Intelligence Framework for Breast Ultrasound Diagnosis

cs.CV ·2026-10-12 ·Shengzhou Zhong, Ziying Wang, Liang Li, Lihua Yan, Shuochun Chen +12 more
code/data similarity 0.65
Abstract · 31 pages, 17 figures, 4 tables

Most existing artificial intelligence systems for breast ultrasound rely primarily on image-driven prediction, with limited incorporation of the knowledge from the Breast Imaging Reporting and Data System (BI-RADS) and the intermediate assessment processes underlying radiologists' workflow, thereby constraining their interpretability and alignment with clinical practice. We curated, to our knowledge, the largest multicenter collection of breast ultrasound images paired with structured BI-RADS descriptors, comprising 9,941 patients across 20 independent datasets. Across 14 testing datasets, IBUS demonstrated consistent generalization performance across different clinical centers and imaging conditions. Incorporating BI-RADS descriptors enabled fine-grained risk stratification, while cross-checking predicted BI-RADS grades against malignancy probabilities identified internally discordant predictions that may warrant additional clinical review. In a reader study involving eight radiologists, IBUS assistance increased diagnostic sensitivity among both junior and senior readers, with the potential of guiding radiologists to make targeted revision in risk stratification. Overall, IBUS exhibits its potential as a second-stage decision-support system that complements radiologists by providing additional risk estimates and interpretable evidence for diagnostically challenging cases. The demo video of IBUS platform is publicly available at https://github.com/zsz1997/IBUS.

0.30

Extraction of clinical findings from mammography and breast ultrasound reports: a comparison between specialists and Artificial Intelligence

cs.CL cs.AI ·2026-09-25 ·Lorenzo Farias, Hanna Reckziegel, Daniela Duarte da Silva Bagatini, Daniel Schulz, Gabriela de Andrade Monteiro +6 more
similarity 0.59
Abstract · 16 pages, 10 figures, 3 tables. Submitted to Artificial Intelligence in Medicine

Breast cancer is the leading cause of cancer-related death among women in Brazil, and the time between the request and the release of mammography reports directly influences adherence to screening, making the agility in processing these reports a critical factor for early diagnosis. In this context, this study compares the performance of a Large Language Model (LLM) with manual extraction performed by a team of health researchers in identifying clinical findings from mammography and breast ultrasound reports written in Brazilian Portuguese. Named Entity Recognition (NER) was applied through Prompt Engineering using a few-shot strategy, employing the Gemini 2.5 Flash model, selected from preliminary exploratory tests with four candidate models. The Gemini 2.5 Flash model demonstrated the best performance, achieving a Macro F1 of 0.91 and a Micro F1 of 0.98. The subjective validation, in which 29 exams of different formats were evaluated by health researchers using a Likert scale, yielded an agreement index of 93.1%. The model outperformed human extraction in overall Macro F1 (0.91 vs. 0.72), as in four reports the model correctly identified information that had been omitted or incorrectly recorded during manual extraction, demonstrating its potential as a complementary verification tool alongside specialists. The results confirm the hypothesis that LLMs, when instructed through Prompt Engineering, can achieve performance comparable to or superior to manual extraction by health professionals.

0.51

Radiology Guideline-derived Decision Graph for Efficient Clinical Decision Support

cs.CV cs.AI ·2026-10-29 ·Xuewen Zhou, Zhen Chen
similarity 0.58
Abstract

Radiological risk stratification and management planning are essential downstream tasks in medical imaging. Automating these tasks is challenging because clinical guideline criteria are distributed across prose, tables, and cross-referenced definitions. We present Guideline-derived Decision Graph (GDGraph), a framework that decouples guideline compilation from case evaluation. During compilation, a large language model partitions guidelines into section-based chunks, extracts local decision subgraphs with linked definitions, and aggregates related branches into an executable decision graph. During inference, a fast System One model answers localized clinical questions while deterministic traversal resolves Boolean logic, turning opaque single-pass predictions into a traceable decision path without task-specific training. Across 347 cases spanning renal cyst, adnexal mass, and thyroid nodule guidelines, GDGraph improves System One accuracy from 57.3% to 90.8%, outperforming retrieval-augmented GPT-4o (80.1%) and graph-guided GPT-4o with chain-of-thought (82.7%) at substantially lower latency and cost. The source code will be available.

0.27

Large Language Model Agents for Evidence Based Genetic Disease Severity Classification

cs.AI q-bio.GNcs.CL ·2026-09-17 ·Tohid Ghasemnejad, Ahmadreza Argha, Mark Grosser, John Wang, Min Yang +5 more
similarity 0.58
Abstract

Disease severity classification for genetic conditions is subjective and labor-intensive, creating bottlenecks in genomic screening, where commercial panels vary widely in size and overlap. We developed an autonomous AI agent integrating Reasoning and Acting (ReAct) with Retrieval-Augmented Generation (RAG) to classify 10,211 Human Phenotype Ontology terms. It uses American College of Medical Genetics (ACMG)-endorsed severity guidelines and American College of Obstetricians and Gynecologists (ACOG) quality-of-life criteria to retrieve PubMed literature, generate interpretable reasoning chains, and independently verify claims. At the phenotype level, using expert-curated cohorts, the agent achieved 93.55% accuracy (MCC 0.9237) with 82.6% to 91.4% of claims supported by direct evidence or valid inferences. Gene-level severity was aggregated across 8,738 pairs, identifying 3,283 autosomal recessive pairs with severe or profound presentations. External validation showed 95.2% concordance with Mackenzie's Mission gene list. This system enables standardized panel design by providing reliable, automated classification supported by direct evidence.

0.07

PelviNeXt: A Modality-Agnostic Hybrid Network for Pelvic Imaging in Women's Health

cs.CV ·2026-08-20 ·Siam Tahsin Bhuiyan, Rashedur Rahman, Sefatul Wasi, Halima Khatun, Ashraful Islam +3 more
publishedbenchmark similarity 0.57
Abstract · Accepted at MICCAI CAPI-WOMEN 2026

Women's health remains substantially under-resourced in medical imaging research, with pelvic pathologies such as polycystic ovary syndrome (PCOS) and pelvic fracture both suffering from a scarcity of public, well-annotated benchmark data despite their clinical importance. We introduce PelviNeXt, a modality-agnostic hybrid architecture combining a dense convolutional feature extractor, hierarchical channel-spatial attention (H-CBAM), a multi-scale fusion module (MSFM), and talking-heads multi-head self-attention (TH-MHSA), applied without modification to both pelvic ultrasound and X-ray inputs. While benchmarking PelviNeXt on PCOSGen, the only gynaecologist-annotated public PCOS ultrasound dataset, we identified extensive exact and near-duplicate contamination within and across the dataset. We audit this contamination via perceptual hashing, publicly release a deduplicated version of the dataset, and establish the first integrity-audited evaluation protocol and baseline for PCOSGen under 5-fold cross-validation. On the only publicly available pelvic fracture X-ray dataset (PXR150), PelviNeXt exceeds previously reported state-of-the-art results across accuracy, recall, specificity, and AUROC. Ablation studies confirm that each architectural component contributes to performance on both tasks. Our results demonstrate that a single architecture, applied without task-specific modification, can serve as a reliable foundation for pelvic imaging across modalities in data-scarce, under-researched areas of women's health.

0.51

Boot-and-Feedback Framework for Generalist-Expert Model Collaboration in Breast Ultrasound Diagnosis

cs.CV cs.MM ·2026-08-25 ·Ming Cheng, Hongyu Sun, Zhaolin Chen, Jun Liu, Hossein Rahmani +1 more
published similarity 0.56
Abstract · 5 pages, 2 figures. Published in ICASSP 2026

Breast ultrasound (BUS) is widely used for breast cancer diagnosis yet remains operator-dependent. While deep learning shows promise, ensuring diagnostic reliability and interpretability is challenging. Recent Multimodal Large Language Models (MLLMs) often generate spurious descriptions due to limited domain knowledge, which mislead downstream expert models and compromise clinical validity. To address these challenges, we propose the Boot-and-Feedback (BooF) model collaboration framework for synergistic MLLM-expert interaction. Specifically, in the Boot Stage, the MLLM is guided by the BI-RADS lexicon and preliminary benign-malignant vision-expert predictions, enabling it to transfer general reasoning to BUS analysis while avoiding hallucinations. Subsequently, the Feedback Stage integrates these descriptions with visual features via a lightweight Attention-Gated Cross-Modality Fusion Module. This allows the expert to leverage textual feedback while adaptively filtering noise. Extensive experiments on multiple BUS datasets demonstrate that BooF substantially outperforms state-of-the-art methods in terms of diagnostic accuracy and interpretability.

0.52

Deep Learning-based Intelligent Diagnosis of Congenital Uterine Anomalies in 3D Ultrasound

cs.CV ·2026-09-14 ·Yueyue Xu, Yuhao Huang, Jiaxiao Deng, Yuanji Zhang, Haoming Zhang +9 more
published similarity 0.56
Abstract · 22 pages, 7 figures, 4 tables

Objective: To develop an intelligent framework, termed CUA-Net, for the automated classification of congenital uterine anomalies (CUA) without requiring coronal plane reconstruction, and to evaluate its clinical applicability. Methods: CUA-Net was built on 3D ResNet-18, equipped with a dynamic data resampling strategy to mitigate the data imbalance issue and a hard sample mining technique to fully learn from the difficult cases by loss adjustment. We further proposed the self-supervised reconstruction to comprehensively explore the volumes and the online data augmentation to refine the wrong predictions and enhance the model's generalization. We compared the CUA-Net with different deep-learning methods and junior/senior sonographers in the testing set. The evaluation metrics included accuracy, precision, recall, F1-score, micro-AUC, and macro-AUC. Results: The proposed CUA-Net exhibited satisfactory performance in both internal and external test sets. In the internal cohort, the model achieved accuracy of 93.88%, precision of 87.01%, recall of 95.92%, F1-score of 88.09%, and micro-AUC of 0.9982 and macro-AUC of 0.9997. In the external set, it maintained good performance with accuracy of 91.52%, precision of 83.27%, recall of 88.63%, F1-score of 81.49%, micro-AUC of 0.9945 and macro-AUC of 0.9990. Our CUA-Net outperformed the junior sonographers across all performance indicators and achieved performance comparable to that of the senior sonographers across most metrics. Conclusion: The CUA-Net demonstrates favorable accuracy and generalizability in classifying common CUA categories, while showing preliminary potential for recognizing less prevalent anomalies. These capabilities may help optimize clinical workflows and support more standardized diagnosis.

0.37

Automated Chest CT Protocol Selection via Large Language Model Derived Text Embeddings from Imaging Request Text

cs.LG ·2026-09-07 ·Zahra Hosseini, Mahan Pouromidi, Farzad Khalvati, Patrik Rogalla
similarity 0.55
Abstract

Purpose: Accurate CT protocol selection is critical for diagnostic quality and patient safety, yet the current process is manual, time-consuming, and prone to inconsistencies. Prior Machine Learning methods using keywords or bag-of-words lack contextual understanding and perform poorly on rare protocols. We propose a decision support system using large language model (LLM) features to recommend protocols from free-text clinical indications, capturing clinical nuance and phrasing variation for more consistent, efficient selection. Methods: In this REB-approved retrospective study, 285,123 chest CT imaging requests from a large academic medical center (2017-2024) were split into training (228,099, 80%) and held-out test (57,024, 20%) sets. Each request included procedure names, clinical indication, HIS comments, and the selected protocol. Clinical text was embedded using a fine-tuned LLM, Meta's LLaMA-3.1-70B; these features input a logistic regression classifier predicting 18 protocol labels (e.g., PE, LDCT). Results: The pipeline achieved a weighted precision of 0.84, weighted F1-score of 0.81, and overall accuracy of 79% across 18 CT protocols. On 300 independent cases with expert consensus, the LLM reached an overall accuracy of 80% versus 83% for radiologists, with no significant difference (p = 0.263). Performance was comparable across most classes, with the LLM exceeding radiologists for some challenging categories, and entropy analyses indicated more balanced protocol use, suggesting reduced variability. Conclusion: An LLM-based recommendation system can leverage general knowledge from a large natural-text corpus to accurately assign chest CT protocols from free-text imaging requests, and may serve as a viable foundation for protocol recommendation tools where inputs require language understanding.

0.15