CS Paper Radar

Extraction of clinical findings from mammography and breast ultrasound reports: a comparison between specialists and Artificial Intelligence

Lorenzo Farias, Hanna Reckziegel, Daniela Duarte da Silva Bagatini, Daniel Schulz, Gabriela de Andrade Monteiro, Letícia Zanatta, Ana Laura Brill Thum, Priscila Schmidt Lora, Débora Oliveira da Silva, Ana Paula Wernz da Cunha Müller, Cristiane Drebes Pedron

cs.CL cs.AI ·submitted 2026-09-25 20:18 UTC · v1

Abstract

Breast cancer is the leading cause of cancer-related death among women in Brazil, and the time between the request and the release of mammography reports directly influences adherence to screening, making the agility in processing these reports a critical factor for early diagnosis. In this context, this study compares the performance of a Large Language Model (LLM) with manual extraction performed by a team of health researchers in identifying clinical findings from mammography and breast ultrasound reports written in Brazilian Portuguese. Named Entity Recognition (NER) was applied through Prompt Engineering using a few-shot strategy, employing the Gemini 2.5 Flash model, selected from preliminary exploratory tests with four candidate models. The Gemini 2.5 Flash model demonstrated the best performance, achieving a Macro F1 of 0.91 and a Micro F1 of 0.98. The subjective validation, in which 29 exams of different formats were evaluated by health researchers using a Likert scale, yielded an agreement index of 93.1%. The model outperformed human extraction in overall Macro F1 (0.91 vs. 0.72), as in four reports the model correctly identified information that had been omitted or incorrectly recorded during manual extraction, demonstrating its potential as a complementary verification tool alongside specialists. The results confirm the hypothesis that LLMs, when instructed through Prompt Engineering, can achieve performance comparable to or superior to manual extraction by health professionals.

Comment
16 pages, 10 figures, 3 tables. Submitted to Artificial Intelligence in Medicine

Closest papers

Nearest neighbours by meaning across the whole index.

The Value of System 1 Models in Medicine

cs.LG ·2026-10-22 ·Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik Lübberstedt +15 more
similarity 0.59
Abstract · 27 pages, 6 figures; includes Supplementary Appendix (3 figures, 5 tables)

Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown. Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging. Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models. Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy. System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.

0.52

From Density to Biopsy Decisions and Malignancy Prediction: A Benchmark Study of Multimodal Large Language Models Against Radiologists in Digital and Contrast-Enhanced Mammography

cs.CV physics.med-ph ·2026-09-13 ·Ali Abbasian Ardakani, Afshin Mohammadi, Taha Yusuf Kuzan, Beyza Nur Kuzan, Alisa Mohebbi +9 more
benchmark similarity 0.59
Abstract · 37 pages, 6 figures, 5 tables

Purpose: To compare four multimodal large language models (MLLMs) with radiologists of varying expertise in breast density assessment, BI-RADS assessment, biopsy candidacy determination, and continuous malignancy probability estimation using digital mammography (DM) and contrast-enhanced mammography (CEM). Methods: This study included 179 women with paired DM/CEM examinations and reference standards. Four MLLMs (ChatGPT-5.2, Gemini-3.1 Pro, Sonnet-4.6, Muse Spark) interpreted images with and without masks; three radiologists interpreted non-masked images. Results: For binary density classification on DM, radiologist accuracies ranged from 55.81% to 78.60%, exceeding most MLLM values (62.33%-71.63%), while masks added limited benefit. Five-category BI-RADS accuracies were higher for radiologists on DM (56.74-67.44%) and CEM (62.33-82.79%) compared with MLLMs (DM 31.16-45.12%; CEM 40.00-55.81%). Binary biopsy-candidacy accuracies were likewise higher for radiologists (DM 85.12-89.77%; CEM 86.98-92.09%) than for MLLMs (DM 61.39-75.35%; CEM 69.30-82.79%), although CEM improved performance across all readers. Lesion masks substantially improved MLLM continuous malignancy-probability accuracies from 64.65%-71.63% to 72.56-78.60% on DM and from 67.91%-77.21% to 72.56%-81.86% on CEM, approaching radiologist ranges (DM 63.72-82.79%; CEM 81.86-88.84%). The corresponding AUCs for the top masked models overlapped those of the human readers. Overall, Muse Spark, followed by Sonnet-4.6, demonstrated the strongest performance among the MLLMs across domains. Conclusion: Radiologists generally outperformed MLLMs in categorical tasks, while selected masked models approached human performance for continuous malignancy probability estimation, suggesting a potential adjunctive role.

0.50

Improving O-RADS Risk Stratification from Ultrasound Reports: A Comparative Evaluation of Hybrid versus End-to-End LLM Reasoning Strategies

cs.AI ·2026-08-24 ·Xiaotong Tan, Chunli Qiu, Xin Liu, Qing Huang, Guangli Zhou +9 more
similarity 0.59
Abstract · Main manuscript: 20 pages, 5 figures, and 2 tables; supplemental material: 11 pages, 1 figure, and 3 tables

Background: Automating clinical guideline-based decision-making with large language models (LLMs) remains challenging because of reliability, hallucination, and limited interpretability. We compared the performance of LLMs and reasoning strategies for automated Ovarian-Adnexal Reporting and Data System (O-RADS) classification from free-text pelvic ultrasound reports. Methods: In this retrospective study, consecutive patients with ovarian masses who underwent pelvic ultrasound were included. Eight LLMs were tested with three reasoning strategies: implicit-knowledge end-to-end, rule-informed end-to-end, and a feature-based hybrid architecture that decoupled feature extraction from rule-based classification. The reference standard was O-RADS categorization established by expert consensus. Results: A total of 310 women with 390 ovarian masses were evaluated. The feature-based hybrid architecture using Gemini 3.6 Flash demonstrated the best performance, achieving an accuracy of 99.2% (387 of 390) and almost perfect agreement with the reference standard (weighted kappa = 1.00; 95% CI: 0.99-1.00). Its performance surpassed that of original clinical reports (accuracy, 87.7% [342 of 390]; weighted kappa = 0.94; 95% CI: 0.91-0.96) and end-to-end LLM strategies (accuracy range, 65.6% [256 of 390] to 95.9% [374 of 390]). For structured feature extraction, Gemini 3.6 Flash demonstrated higher overall accuracy than Claude Fable 5 (98.9% vs 97.8%; P < 0.001). The hybrid architecture reduced misclassification errors and mitigated the overstaging tendency observed in original reports. Conclusion: The feature-based hybrid LLM architecture that separates clinical feature extraction from deterministic guideline execution enables highly accurate, reliable, and interpretable automated O-RADS classification, providing a promising approach for standardized, guideline-based clinical decision-making.

0.41

Can decision models extract clinical data from cancer pathology reports? An evaluation of accuracy, calibration, and failure modes

cs.CL cs.AIcs.LG ·2026-11-15 ·Indranil Mallick, Paromita Roy
similarity 0.58
Abstract · 22 pages, 7 figures

Decision models are a new class of language model that, instead of generating text, choose one option per question from a fixed list and return a probability for every option. They have not yet been evaluated on clinical text. We evaluated two open-weights decision models, Nimble 9B and Tev1 4B, for extracting 25 fields from 1,113 oral cavity cancer pathology reports from a single centre, against a prospectively maintained clinical database. We compared them with two generative models: Qwen3.5 9B, run locally, and GLM-5.3-flash, run through a cloud API. Tev1 reached a mean field accuracy of 0.917 (95% CI 0.913 to 0.920), the same as Qwen3.5 9B (0.918; p = 0.26), and was four times faster (15 s against 61 s per report). Nimble reached 0.862 and GLM-5.3-flash 0.986. Both decision models matched GLM-5.3-flash on simple dichotomous categories. They were weak on measurements binned into categories, on fields whose correct answer was not reported, and on some complex decisions (e.g. involved margins). We found that the main cause of the inferior performance of Nimble's came from asking 25 questions in one request: with two questions per request, its accuracy improved. Pooled over fields, the returned probabilities were well calibrated (expected calibration error 0.022 and 0.026), but they did not flag systematic errors within single fields. A simulated strategy of sending answers with a probability below 0.94 to GLM-5.3-flash raised Tev1's accuracy to 0.982, with 38% of answers escalated. Decision models can extract explicitly stated findings from pathology reports quickly on local hardware and return useful probabilities. They should be validated in the configuration in which they will be used, restricted to the fields in which they are reliable, and combined with other methods for numeric values.

0.18

A Concept-informed Interpretable Artificial Intelligence Framework for Breast Ultrasound Diagnosis

cs.CV ·2026-10-12 ·Shengzhou Zhong, Ziying Wang, Liang Li, Lihua Yan, Shuochun Chen +12 more
code/data similarity 0.56
Abstract · 31 pages, 17 figures, 4 tables

Most existing artificial intelligence systems for breast ultrasound rely primarily on image-driven prediction, with limited incorporation of the knowledge from the Breast Imaging Reporting and Data System (BI-RADS) and the intermediate assessment processes underlying radiologists' workflow, thereby constraining their interpretability and alignment with clinical practice. We curated, to our knowledge, the largest multicenter collection of breast ultrasound images paired with structured BI-RADS descriptors, comprising 9,941 patients across 20 independent datasets. Across 14 testing datasets, IBUS demonstrated consistent generalization performance across different clinical centers and imaging conditions. Incorporating BI-RADS descriptors enabled fine-grained risk stratification, while cross-checking predicted BI-RADS grades against malignancy probabilities identified internally discordant predictions that may warrant additional clinical review. In a reader study involving eight radiologists, IBUS assistance increased diagnostic sensitivity among both junior and senior readers, with the potential of guiding radiologists to make targeted revision in risk stratification. Overall, IBUS exhibits its potential as a second-stage decision-support system that complements radiologists by providing additional risk estimates and interpretable evidence for diagnostically challenging cases. The demo video of IBUS platform is publicly available at https://github.com/zsz1997/IBUS.

0.30

Mammography Foundation Models for Opportunistic Prediction of Major Adverse Cardiovascular Events

eess.IV cs.CVcs.LG ·2026-09-16 ·Paula Feldman, Nusrat Binta Nizam, Sunwoo Kwak, Batuhan Karaman, Katerina Dodelzon +1 more
code/data similarity 0.56
Abstract

Cardiovascular disease (CVD) remains the leading cause of death among women, yet cardiovascular risk assessment often relies on clinical variables that may be missing, outdated, or unavailable in routine care. Screening mammography offers an opportunity for opportunistic cardiovascular risk stratification because it is routinely acquired and contains vascular features, including breast arterial calcifications (BAC), that are associated with cardiovascular risk and events. We evaluate whether mammography specific foundation models, originally pretrained for breast cancer-related tasks, can transfer to cardiovascular risk prediction without cardiovascular specific supervision or explicit BAC annotation. We constructed a 5-year major adverse cardiovascular event (MACE) cohort of 22,497 women linked to electronic health record outcomes, including 500 events (2.22% prevalence). The foundation models achieved AUROCs of 0.823 and 0.822 substantially exceeding an age-only model (AUROC 0.765), despite using only the screening mammogram as input, with no clinical variables. Both foundation models evaluated assigned substantially higher predicted risk to patients with radiologist-documented BAC, despite BAC never being used as a training label, and showed activation patterns consistent with vascular findings. Together, these findings suggest that mammography foundation models can recover clinically relevant cardiovascular risk information directly from mammographic pixels and suggest that screening mammography may provide an opportunistic source of cardiovascular risk information to complement conventional clinical assessment without additional imaging. Code is available in https://github.com/PauFeld/MammoCVD

0.36

A local language model layered with rule-based and neural detectors for clinical text de-identification: an open-source toolkit and evaluation

cs.CL cs.CYcs.SE ·2026-11-09 ·Valentin Burkin
code/data similarity 0.56
Abstract · 17 pages, 2 figures, 4 tables; supplementary material as ancillary file. Code: https://github.com/valburkin/DeidSharp

Objectives: To measure whether a locally hosted large language model (LLM), stacked with deterministic and clinical named-entity recognition (NER) detectors, finds more protected health information (PHI) than open tools, and at what precision. Materials and Methods: DeidSharp, an open-source .NET toolkit, combines the findings of pluggable detectors (patterns, a clinical NER model, a local 26B mixture-of-experts LLM) and fails closed on any detector error. Configurations fixed on tuning halves were compared, under a prespecified protocol, with deid, Philter, the Stanford/Penn de-identifier, OpenAI Privacy Filter and GLiNER on reporting halves of PhysioNet's nursing notes (889 spans) and semi-synthetic MIMIC-IV-Note discharge summaries (29,023 spans), and on synthetic ASQ-PHI queries, with paired patient-level bootstrap intervals. Results: In the nursing notes, against Stanford/Penn, the recall-first stack found 98.9% of PHI (+2.8, 95% CI 1.4 to 4.4) at 9.3 points lower precision; the precision-first stack, without NER, found 96.5%, matching Stanford/Penn, at 19.6 points higher precision (83.2%). In the discharge summaries, both stacks led Stanford/Penn by more than 20 points (recall-first 95.3%, +21.5, 20.5 to 22.4), almost entirely on generated untyped names; on typed labels all three exceeded 99%. All four prespecified comparisons held. No configuration beat deid significantly on its home corpus; Philter found more discharge-summary spans than the recall-first stack at 23 points lower precision. Discussion: The LLM was the main detector and NER added place names; asked to verify its own findings, the LLM discarded a quarter of true PHI. Conclusion: A local LLM layered with deterministic detectors offers recall-first and precision-first operating points without sending text off-site.

0.35

Fine-Grained Japanese Clinical Named Entity Recognition: A Controlled Comparison of BERT and Open-Weight Large Language Models

cs.AI cs.CL ·2026-11-17 ·Feng Han, Ayako Yagahara, Kenji Hirata, Atsushi Yoshida, Kohsuke Kudo
benchmark similarity 0.54
Abstract · 33 pages, 3 figures, 5 tables; includes appendices with supplementary tables and one supplementary figure

Background: Generative large language models (LLMs) offer an alternative to encoder-based clinical named entity recognition (NER), but their performance on fine-grained Japanese extraction tasks and sensitivity to generation settings remain uncertain. Methods: We compared two fine-tuned BERT-CRF baselines with nine open-weight LLMs on iCorpus, which defines 113 entity categories. The evaluation used 433 sentences from 36 test documents; 1,672 sentences were used for training. LLMs were evaluated using zero-shot prompting with and without JSON Schema constraints and three-seed QLoRA fine-tuning. Fine-tuned models were assessed under different output-token limits, including 900 and larger model-specific limits of 2,600 or 4,096 tokens. Performance was measured using sentence-level label-surface matching with relaxed and exact-surface F1. Results: The highest zero-shot relaxed F1 was 0.337, compared with 0.836-0.841 for the BERT baselines. At the larger output limits, all eight fine-tuned LLMs with at least 13B total parameters exceeded both BERT baselines (relaxed F1, 0.882-0.914; exact-surface F1, 0.840-0.880). Across three-seed means, increasing the output limit improved relaxed F1 by 0.052-0.085, alongside higher recall and fewer length-limited outputs. JSON Schema constraints changed relaxed F1 by -0.014 to +0.008 among seven models outside the two reasoning-oriented configurations, while medical-general model pairs showed no consistent advantage for medical specialization. Conclusions: On this historical Japanese case-report benchmark, task-specific fine-tuning combined with adequate generation capacity was associated with stronger LLM extraction performance. Output-token limits materially affected comparisons with BERT, whereas enforcing output structure alone did not overcome low zero-shot accuracy.

0.09