Abstract

In medical imaging, it is common to use learned perceptual image patch similarity (LPIPS) to compare images semantically in feature space. Although backbones pretrained on natural images are widely used for LPIPS computation, B-mode ultrasound images possess distinct speckle patterns and acoustic-specific image statistics that are fundamentally different from natural images and even from other images in radiology. Consequently, we propose that domain-specific models are needed to measure perceptual similarity in ultrasound data, a finding which is not necessarily the case for other imaging modalities. We compare LPIPS metrics across downstream tasks like classification, segmentation and reconstruction using natural image, medical generalist and ultrasound backbone models and show that selection of LPIPS backbone is a non-trivial design choice. In particular, the ultrasound backbone models were more correlated with downstream performance of supervised models than classical and natural image models, and optimization of the LPIPS loss with an ultrasound backbone achieved a strong balance between reconstruction quality and realism. Our code is available at https://github.com/talg2324/UltraPIPS and introduces the UltraPIPS library, a set of LPIPS metrics based on the open-source foundation models analyzed in this paper.

Comment
MICCAI ASMUS 2026

Closest papers

Nearest neighbours by meaning across the whole index.

UltraBench 2: Towards Robust Evaluation of Vision Foundation Models on Ultrasound

cs.CV cs.LG ·2026-09-23 ·Ashwath Radhachandran, Adam Tupper, Christian Gagné, William Speier
benchmark similarity 0.75
Abstract

Benchmarking is an increasingly critical part of research in machine learning and the domains where it is applied, including healthcare. Yet, despite the steady development of new ultrasound foundation models in recent years, the development of well-designed benchmarks to evaluate them has lagged behind. This deficiency has led to fragmented and inconsistent evaluations of competing models, making it difficult to measure progress. To address this issue, we introduce UltraBench 2, a comprehensive benchmark with wide anatomical and task coverage, and a focus on standardization, reproducibility, and ease-of-use. Using this benchmark, we compare existing vision foundation models for ultrasound image analysis. Our analyses demonstrate that ultrasound-specific pretraining still leads on classification, but that state-of-the-art general-purpose models have drawn level on segmentation.

0.05

UltraDiff: Differentiable Ray Tracing in Ultrasound for Shape Optimization

cs.GR cs.CV ·2026-10-06 ·Felix Duelmer, Magdalena Wysocki, Nassir Navab, Mohammad Farid Azampour
top venuehot direction similarity 0.67
Abstract · 4 pages, 4 figures, 1 table. Accepted at SIGGRAPH Asia 2026 Technical Communications

Physically-based differentiable rendering enables gradient-based optimization of scene parameters by matching rendered images to measurements, but has so far mainly focused on light transport. We extend this paradigm to medical ultrasound, where image formation resembles transient rendering: echoes are binned by time-of-flight rather than projected onto an image plane. We present UltraDiff, a modular framework for differentiable ultrasound ray tracing. UltraDiff formulates ultrasound image formation as a path-space integral, gated by travel time between the transducer and tissue interfaces, and derives a Monte Carlo estimator of both the forward model and its gradients with respect to scene parameters. We demonstrate this on an inverse geometry estimation: starting from a sphere, an SDF is optimized until simulated echoes match measured ones, recovering vertebral surfaces from simulated B-mode sweeps and from a real robotic acquisition of a spine phantom. Unlike state-of-the-art ultrasound shape reconstruction methods, which rely on pre-segmented images, our approach operates unsupervised on B-mode images through analysis-by-synthesis, while achieving competitive geometric accuracy. Implemented on top of Mitsuba 3, UltraDiff brings differentiable path tracing to a new sensing modality and provides a foundation for inverse problems in acoustic imaging.

0.47

Zero-Shot Adaptation of Medical Vision Foundation Models for High-Frequency Micro-Ultrasound Prostate Segmentation

cs.CV cs.LG ·2026-08-14 ·Ayusha Abbas, Saram Abbas, Kabita Adhikari
similarity 0.66
Abstract

Prostate cancer claims a life every 80 seconds. Early detection is needed to prevent disease progression, and both PSA density calculation and biopsy decisions rely on knowing the exact boundary of the gland. Conventional ultrasound at 6-12 MHz blurs this boundary, missing one in three high-risk cancers. Micro-ultrasound (29 MHz) improves resolution threefold but introduces dense acoustic speckle that obscures the outer wall; given the same image, two clinicians draw outlines differing by over 10% in area. Supervised methods are costly and generalise poorly across scanners. Can a foundation model segment the prostate with no training data? We present the first zero-shot pipeline for this modality: MedSAM, pre-trained on over 1.5 million medical images, localises the prostate; we then apply CLAHE to sharpen the outer wall, binary dilation to recover missed pixels, and Fourier smoothing (4 modes, s=1.05) to refine the boundary. MedSAM requires a spatial prompt, so we evaluate bounding-box and point-click strategies across 75 patients of the Micro-Ultrasound Prostate Segmentation dataset (2,621 slices). On the 20-patient held-out test set, the pipeline reduces mean boundary-distance error by 45% (Dice 0.749+/-0.043 to 0.865+/-0.029; HD95 217.2+/-36.9 to 120.1+/-26.1 px), reaching Dice 0.859 across the cohort. Its mean overlap shows no significant difference from the three non-expert rater groups (p>0.19), while segmenting 38-52% more consistently (lower inter-patient standard deviation). Point-click prompts fail regardless of placement (best Dice=0.350), because speckle gives no stable local contrast. Only an approximate bounding box is required, so any clinic can deploy it without data collection, annotation, or retraining.

0.04

UltraG-Bench: A Multi-task Benchmark for assessing Large Vision-Language Models on Pixel-level Evidence Grounding in Ultrasound

cs.CV cs.AI ·2026-09-25 ·Quanhao Zhu, Bo Xu, Rui Lin, Chenyuan Wang, Yu Shao +5 more
benchmarkcode/data similarity 0.66
Abstract

Ultrasound is one of the most widely used medical imaging modalities, and recent large vision-language models(VLMs) have shown increasing capabilities in ultrasound image understanding. However, these models fail to provide pixel-level visual evidence aligned with their semantic predictions, and their fine-grained grounding capability in ultrasound remains largely unclear. We introduce UltraG-Bench, a large-scale multi-task benchmark for evaluating pixel-level evidence grounding in ultrasound. UltraG-Bench is built by annotating 40 public ultrasound segmentation datasets spanning 13 anatomical categories, and comprises three progressive tasks: instruction-guided segmentation, evidence-grounded VQA, and evidence-grounded report generation, with 331125, 666779, and 138832 annotations, respectively. Comprehensive evaluation of 14 state-of-the-art models reveals a substantial gap between semantic understanding and fine-grained pixel-level localization. We further propose UltraG-Agent, which combines the semantic reasoning capabilities of a VLM with the ultrasound-specific segmentation capability of UltraSAM3. Experiments show that UltraG-Agent substantially improves both semantic prediction and pixel-level visual grounding. Our dataset and code are available at https://github.com/zhuqh19/UltraG-Bench.

0.60

Diffusion Plug-in Priors for Self-Supervised Ultrasound Video Restoration

cs.CV ·2026-11-03 ·Chu Chen, Mingduo He, Yining Li, Yinhao Wu, Wei Tang +4 more
code/data similarity 0.66
Abstract

Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely available. We aim to jointly super-resolve and despeckle ultrasound videos without paired training data or network retraining. We propose UltraDiff, which uses a frozen pre-trained diffusion model (DM) as a plug-in prior and restores each frame by optimizing the latent seed of the DM sampler under a range-constrained maximum a posteriori formulation. We derive a speckle-aware data-fidelity term from a Rayleigh scale-family model and characterize its relative-residual and variance-adaptive weighting properties. We further introduce a stabilized fidelity that is bounded below and strictly convex in log intensity for positive observations in its unclamped form. A total-variation regularizer complements the DM prior, and a temporal seed update warm-starts each frame from the optimized seed of its predecessor. On EchoNet-LVH videos with simulated speckle and additive noise, UltraDiff with a natural-image prior improves PSNR by 1.24\,dB over the strongest baseline, and ultrasound-related priors improve it further. On real clinical echocardiography videos, UltraDiff reduces the mean absolute error of zero-shot ejection fraction (EF) prediction from 7.31 to 6.37 EF points relative to DUP, the strongest baseline. Combining a speckle-aware fidelity with frozen diffusion priors enables ground-truth-free ultrasound video restoration that benefits downstream measurement. UltraDiff needs neither paired data nor retraining and is not tied to a specific diffusion checkpoint. Code associated with this work will be made publicly available upon acceptance.

0.21

A Multi-Source Ultrasound Benchmark Revealing the Limits of Contemporary Self-Supervised Anomaly Detection Methods

cs.CV cs.LG ·2026-10-07 ·Marco Riedenauer, Daniel Kienzle, Pratik Mayekar, Rainer Lienhart
publishedbenchmark similarity 0.64
Abstract · 7 pages, 3 figures

Self-supervised anomaly detection is a promising paradigm for medical ultrasound, as normal images are often easier to obtain than exhaustive annotations of all possible pathologies. However, most existing evaluations are limited to a single anatomy or task, making it unclear whether models learn a robust notion of normal ultrasound appearance or only a source-specific representation. We introduce the SADUSI benchmark, a multi-source ultrasound dataset designed to train and evaluate anomaly detection methods across a broad range of anatomical regions, views, and acquisition protocols. The goal of SADUSI is to provide a diverse normal ultrasound distribution and a benchmark for visible structural anomalies that can be assessed from single images. We evaluate representative self-supervised anomaly detection methods and find that current approaches struggle in this setting. In particular, reconstruction-based diffusion methods such as AnoDDPM and DeCo-Diff achieve pixel-level AUROC values of 0.56-0.72 and maximum F1 scores of 0.10-0.26, indicating limited separation of pathology from normal image regions. Feature-based PatchCore variants perform better, reaching pixel-level AUROC values of 0.76-0.83, but remain limited with maximum F1 scores of 0.14-0.40. These findings suggest that broad multi-source ultrasound anomaly detection remains an open challenge and that SADUSI can serve as a resource for developing methods that generalize beyond anatomy-specific settings.

0.40

Open ultrasound foundation model for robust segmentation and clinical measurement across heterogeneous settings

cs.CV ·2026-09-16 ·Chao Qin, Fahad Shahbaz Khan, Salman Khan, Sarim Ather, Siddiq Anwar +2 more
code/data similarity 0.64
Abstract · The PDF includes the Supplementary Information. Code is available at https://github.com/AlfredQin/sonobase

Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 clinical applications and 17 countries, and SonoBase, an interactive segmentation foundation model pretrained on it. Across fifteen evaluation datasets introducing new organs, devices, operators, and geographies, SonoBase outperforms SAM2, MedSAM2, and the concept-promptable MedSAM3 on every dataset and matches per-dataset specialist models trained on the same data; on fully external data it exceeds the accuracy these baselines achieve on their own in-distribution benchmarks. Ejection fraction derived from its segmentations falls within inter-observer variability (6.63\% error), with fewer misclassifications at the defibrillator-candidacy threshold than either promptable baseline (13\% versus 18--42\%); fetal head-circumference (1.81~mm) and gestational-age (1.2 days) errors fall below inter-observer variability. Where a baseline fails outright, one in four test cases, SonoBase recovers a usable segmentation in 81\% of them, including on handheld probes operated by minimally trained users in two low- and middle-income countries (Sierra Leone and Tanzania). Five labeled examples can help the model adapt to a new setting, and the identical training protocol transfers well to newer models such as SAM3, locating the advantage in ultrasound-specific pretraining rather than any single architecture. To ensure reproducibility and enable the community to build on SonoBase as a platform, we release all checkpoints, optimizer states, data-split indices, deduplication hashes, and starter code at https://github.com/AlfredQin/sonobase.

0.36

Learning Prostate Anatomy at Test Time for Cancer Detection in Micro-Ultrasound

cs.CV cs.LG ·2026-08-20 ·Obed Korshie Dzikunu, Mohammad Mahdi Abootorabi, Mohamed Harmanani, Paul F. R. Wilson, Emma Willis +5 more
code/data similarity 0.63
Abstract

Domain shift across clinical centers using different imaging hardware or acquisition protocols remains a fundamental barrier to deploying deep learning models for prostate cancer (PCa) detection. Existing test-time adaptation (TTA) methods address distribution shift through entropy minimization or augmentation-based self-supervision, correcting for statistical differences in image appearance but ignoring the anatomical structure of the target domain. We propose ANT, a segmentation-guided TTA framework that adapts a pretrained cancer detection encoder to the target domain by solving an auxiliary prostate segmentation task at test time, supervised by pseudo-masks from a frozen pretrained segmentation network. By aligning encoder representations to prostate anatomy in the target domain, ANT corrects domain-specific feature drift while preserving cancer-discriminative structure. The model was trained on 693 patients imaged with an earlier-generation micro-ultrasound scanner in a multi-center clinical trial, and evaluated on 118 patients acquired with a newer-generation system across two centers in another clinical trial. Under a leave-one-center-out protocol with identical evaluation conditions across all methods, ANT improves mean AUC by 2.9% and 3.6% at the biopsy-core and patient levels, respectively, over no adaptation, outperforming TTA baselines. Code is available at: https://github.com/ObedDzik/ant.git.