CS Paper Radar

Review Before Trust: Source-Grounded Integrity Gates for AI-Assisted Personal Health Records

Nora Girda, Adrian Groza

cs.AI ·submitted 2026-08-30 18:51 UTC · v1

Abstract

Large language models can convert medical documents into structured data, but plausible output may still be unsupported by the source. Persisting such output in a longitudinal health record, a record that accumulates patient information over time, therefore creates an integrity risk: unverified data may influence later summaries, trends, or preventive-care computations. We introduce an evidence-gated trust-promotion model that keeps generated data provisional until a deterministic monitor verifies it against the source document. The monitor admits a candidate for a specified downstream use only when the source contains a unique supporting quotation, the relevant fields occur within the same laboratory row, and the required provenance is preserved. The generator cannot approve its own output, missing or ambiguous evidence causes refusal, and refused candidates remain available for human review rather than being silently discarded. We implement the model in Medical DataCloud, a personal health-record application, and evaluate it through automated tests and a replay of saved extraction outputs. All 22 conformance and mutation tests pass. The replay covers nine historical laboratory PDF reports containing 102 manually labelled rows. The reports produce 97 numeric candidates: schema validation accepts all 97, an earlier packet-level evidence check accepts 94, and the hardened quotation- and row-level policy admits 72 while retaining 25 for review. The study evaluates system integrity rather than clinical correctness or clinical safety. The results demonstrate the technical feasibility of an enforceable boundary that prevents generated claims from authorizing their own reuse in a longitudinal health record.

Closest papers

Nearest neighbours by meaning across the whole index.

CareGraph: An Auditable Hybrid AI Framework for Evidence-Grounded Personalized Longitudinal Health Intelligence

cs.AI cs.IRcs.MA ·2026-08-25 ·Pratik Ghawate, Tanvi Patil
benchmarkcode/data similarity 0.68
Abstract · 21 pages, 7 figures, Code and data: https://github.com/PratikGhawate/ai-personalized-health-intelligence

Artificial intelligence is transforming personalized healthcare, yet fragmented clinical, self reported, and wearable evidence remains difficult to interpret and trace. We present CareGraph, an auditable hybrid AI framework that converts heterogeneous records into prioritized trends, missing context indicators, bounded next steps, discussion questions, and provenance linked explanations. CareGraph organizes evidence without diagnosing, predicting outcomes, selecting treatment, or making autonomous clinical decisions. Its pipeline covers deterministic analysis, context detection, graph construction, constrained language model synthesis, evidence validation, safety controls, and release gating. Tests used synthetic cohorts of 400 patients each for development, validation, and holdout. On holdout data, a frozen ordinary least squares trend rule with a sufficiency gate achieved 0.827 accuracy, 0.837 macro F1 with a 95 percent confidence interval of 0.819 to 0.854, and 0.974 insufficient data F1. Missing context detection achieved 0.815 strict micro F1 versus 0.318 for the legacy detector. On an authored holdout benchmark, safety ruleset version 1.2 achieved 1.000 precision, 0.950 recall, and 0.974 F1. An audit requiring graph retrieval across 80 patients yielded 79 syntheses and 78 presentations without fallback; one output was blocked and one failed closed because of an invalid evidence key. Against monolithic GPT 5.6 on 56 matched patients, CareGraph was faster at 40.15 versus 49.62 seconds, shorter at 661 versus 1,163 words, and showed better exploratory lexical alignment with longitudinal targets; the baseline used fewer tokens and cited more raw evidence. Graph auditing verified provenance and deterministic retrieval; incremental graph effects on generation require paired evaluation. CareGraph offers a safety bounded foundation for intelligent personalized health systems.

0.42

Making every stage of medical device document assessment with large language models deterministic

cs.CL cs.IR ·2026-10-15 ·Ryosuke Suzuki
similarity 0.66
Abstract · 30 pages, 3 figures, 3 tables; supplementary tables S1-S15 and two supplementary notes included

To show that a medical device complies with regulation, experts judge whether documents and records meet each requirement and record the judgment for others to verify. For each assessment item that experts define, large language models could prepare a preliminary assessment: a label such as Satisfied or Not satisfied, a reason and quoted evidence. We sent fourteen commercial deployments of such models (seven models from three providers, through six routes) the same request repeatedly, with the deterministic sampling settings each accepted; every deployment returned differing assessments for at least one request, and in twelve the label changed. Reducing reasoning where the interface allows it did not reduce the variation, and prompts of retrieved passages removed it only for the smallest models. The same open-weight model was reproducible or not depending only on how it was served. A pipeline we built to be deterministic at every stage -- text extraction and optical character recognition (OCR), chunking, embedding, indexing, retrieval and inference -- returned byte-identical output at each stage across reruns, interruptions, edits, machines of one graphics processing unit (GPU) model and days, for blood glucose meter and infusion pump documents. OCR, embedding and approximate retrieval varied when their own serving was not made invariant, and outputs changed with the GPU model and with the inference engine's scheduling settings, which therefore belong in the recorded configuration. End-to-end determinism is achievable and gives a testable basis for audit and change control.

0.24

Actionable Feedback: Improving Model Capabilities from User Edit Data on Clinical Documentation

cs.CL cs.AIcs.LG ·2026-10-14 ·Daniel P. Jeong, Yewon Byun, John Giorgi, Peng Xu, Zachary C. Lipton +1 more
similarity 0.66
Abstract · Preprint

Large language models (LLMs) are increasingly being deployed in clinical documentation workflows, where clinicians review and edit their outputs before use. In principle, these clinician edits represent a scalable source of supervision for model training. In practice, not all edits represent actionable feedback: for instance, on data drawn from real-world deployment of an AI clinical documentation product, our review suggests that over 45% of edited outputs contain user-added information that is not directly supported by the inputs to the model. Naively fine-tuning on such edits risks teaching the model to hallucinate. In this paper, we develop a method to address this challenge. Given that real clinician edits on deployed documentation tools are not publicly available, we first develop a taxonomy of clinician-editing behaviors, informed by data from a deployed AI clinical documentation product. Then, we develop a method for generating semi-synthetic clinician-edit data, informed by our taxonomy, on a discharge-summary generation task based on MIMIC-III, a public dataset. Finally, we introduce simple filtering methods for identifying actionable edits, with accuracy evaluated by expert review. We show empirically, on our semi-synthetic dataset, that naive fine-tuning on raw edited output increases ungrounded content, while our approach of progressively filtering toward grounded edits enables improvement on clinician-alignment metrics while retaining faithfulness to the input context.

0.23

EviStreams: Human-in-the-Loop AI Data Extraction for Systematic Reviews in Medicine

cs.CL ·2026-09-23 ·Sai Karthik Kosuri, Ankita Shashikant Bhosale, Michael Glick, Alonso Carrasco-Labra, Chris Callison-Burch
top venuecode/data similarity 0.65
Abstract · 12 pages, 5 figures. Accepted to EMNLP 2026 System Demonstrations

Systematic reviews underpin clinical guidelines, yet their data-extraction step is a major expert-labor bottleneck bound by a protocolized workflow: two reviewers extract each study independently, an adjudicator resolves disagreements, and the team keeps an auditable record of how every value was produced. Large language models can assist with extraction, but that assistance must fit established review protocols and preserve reproducibility. We present EviStreams, a live, open-source, no-code web platform that puts review teams in control of AI-assisted extraction at three key stages: program design (a structured decomposition approved before any code runs), field specification (typed field definitions calibrated from a pilot), and extracted predictions (reviewer-blinded dual review with adjudication). Working through a form builder, a domain expert defines typed fields rather than prompts, runs extraction over uploaded PDFs, inspects every value alongside the supporting passage it came from, and resolves a reviewer-blinded dual review into an auditable consensus export. An evaluation across four clinical corpora and three frontier model families, released with the system, shows that extraction quality is shaped far more by the field specification than by the choice of model. EviStreams is live at https://evistreams.com/demo and released under Apache-2.0.

0.43

TwinGuard-Lite: A Rule-Based State-Admission Gateway for Generative Patient Digital Twins

cs.CR ·2026-10-06 ·Wenhui Chu, Sheikh Rabiul Islam
published similarity 0.65
Abstract · 6 pages, 2 figures, 1 table. Accepted to HealthSec'26 (Cybersecurity in Healthcare), co-located with ACSAC 2026

Future generative patient digital twins may combine longitudinal health records with language-model agents and keep information across sessions. The wording of a proposed update does not reveal whether it comes from an allowed source, conflicts with the patient's record, or belongs to someone else. We present TwinGuard-Lite, a rule-based gateway that admits an update to a twin's persistent state only if it passes checkable approximations of two integrity properties. Grounded state consistency (GSC) is approximated by a provenance check and a contradiction check; cross-patient noninterference (CPN) is approximated by a namespace check against trusted transport metadata. We evaluate three attack families over 20 seeded person-level splits of a semi-synthetic stream built from the openly licensed eICU database demo, with 29,131 $\pm$ 2706 candidate updates per seed. A keyword filter and an anomaly detector detect 16% and 24% of attacks, respectively; a provenance-only ablation detects 59.9% but misses every cross-patient attack. Combining GSC and CPN yields 99.1% precision, 90.5% recall, a 94.6% F1 score, and a 0.033% false-positive rate. Every attack the full gateway admits falsely claims a trusted source; when the retrieval channel does so, 92.9% of retrieval attacks are admitted. The results hold under stated trust assumptions, and no language model, agent, or retriever is executed: TwinGuard-Lite is a mechanism-level proof of concept that motivates authenticated, patient-bound ingestion, not a clinical safeguard.

0.41

TIDE 2.0: an open, model-agnostic engine for keyed de-identification of clinical notes

cs.CL cs.AI ·2026-10-05 ·Jose D. Posada, Somalee Datta, Priya Desai
code/data similarity 0.65
Abstract

Clinical notes capture most of what is documented about a patient's care, but they cannot be used for research until protected health information (PHI) is removed. De-identification is often treated as a detection problem. Detection alone is not sufficient: redaction strips clinical content along with identifiers, date blanking destroys the temporal intervals needed for longitudinal analysis, and assigning a fresh random surrogate at each occurrence breaks links between a patient's notes. We present TIDE 2.0, an MIT-licensed engine with two separable stages: an interchangeable recognizer and a keyed anonymizer. Both run on hardware the institution owns. Surrogates are generated cryptographically with no stored linkage table. Dates shift by a per-patient, interval-preserving offset; each value receives the same surrogate across all occurrences under a given key; and a release produced under a new key cannot be linked to earlier releases. We also release TIDE2-Sentry, a recognizer distilled from a large language model. On two gold-annotated corpora from two institutions, the default configuration reached span-level recall of 0.88 in-domain and 0.77 on the second institution's corpus, at precision 0.88 and 0.87. We report recall and precision per category alongside these aggregates. The engine is open source, and the recognizer is available under a gated research-use agreement, so institutions can run, inspect and extend both within their own environments.

0.62

TrustDABench: Benchmarking Reliability and Robustness of LLMs for Structured Data Analysis

cs.CL cs.SE ·2026-08-25 ·Boshen Shi, Yize Liu, Chen Zhao, Ce Chi, Zhendong Wang +2 more
benchmarkcode/data similarity 0.64
Abstract · Code&Data: https://github.com/Skyorca/TrustDABench

LLMs are increasingly used to analyze spreadsheets, CSV files, and other structured data, but producing a correct-looking answer is not the same as producing a trustworthy analysis. A trustworthy result should be supported by a valid path from the user question to the relevant data evidence. This requirement creates two diagnostic questions: whether an LLM can refuse to answer or ask for clarification when such a path does not exist, and whether it can preserve the correct analysis when the same evidence is expressed in different table forms. We introduce TrustDABench, a benchmark that operationalizes these questions as reliability and robustness. Starting from the evidence-path view, we derive 19 perturbation operators and instantiate them through an Agentic-LLM-based generation framework. TrustDABench contains 2,340 human-verified perturbed instances, and we evaluate eight representative LLMs. The results show substantial headroom: the best reliability result is only 24.21% average MRS, achieved by GPT-5.5, while the best robustness result still has 9.10% average ASR, achieved by Claude-Sonnet-5. The failures are systematic: models rarely detect conflicting evidence, often continue along executable but unsupported analysis paths, and remain sensitive to perturbations that change observation boundaries or cross-table relations. These findings suggest that stronger evidence-boundary recognition and representation-invariant reasoning are still needed for reliable structured-data analysis.

0.55

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

cs.LG ·2026-08-13 ·Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala +1 more
benchmark similarity 0.64
Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

0.04