CS Paper Radar

LoFi RADIO: A Distilled In-Domain Backbone Applied for Artifact-Severity Grading of Ultra-Low-Field Neonatal Brain MR

Jonathan B. Martin, Yashwant Kurmi, Charlotte R. Sappo

eess.IV cs.CV ·submitted 2026-09-02 14:47 UTC · v1
publishedhot direction

Abstract

Ultra-low-field MRI makes neonatal brain imaging deploy- able in low-resource settings, but its low SNR, lack of shielding, and long scan duration make it especially prone to acquisition artifacts, motivating automated quality control. We address the LISA 2026 Task 1a challenge: multi-label severity grading (0/1/2) of seven common image artifacts on ULF T2 weighted volumes. We identify that a number of backbones may be successfully paired with a classification MLP, but that no single backbone is uniformly best across artifacts. To improve performance, we evaluate routing complementary foundation model teachers through a per-artifact gate, as well as distilling the teachers into a single in-domain ViT-S student (LoFi RADIO) over an unlabeled low-field MRI corpus. Both of these strategies improve the weighted composite. The distilled backbone matches or exceeds the gate and has the added advantage of not requiring deployment of multiple large foundation models at infer- ence.

Comment
11 pages, 2 figures, MICCAI 2026 satellite

Closest papers

Nearest neighbours by meaning across the whole index.

A Dual-Stream Regulated Reconstruction and Segmentation Network with Hierarchical Artifact-Prior Modeling for Ultra-Low-Field Pediatric Neuroimaging

cs.CV ·2026-09-17 ·Bahram Jafrasteh, Leo Milecki, Qingyu Zhao
similarity 0.68
Abstract

Automated quality assessment, enhancement, and segmentation of multiple structures in $0.064\,\mathrm{T}$ ultra-low-field pediatric MRI are limited by a low signal-to-noise ratio, weak anatomical boundaries, and frequent artifacts. We present a unified framework for the LISA 2026 Challenge that performs all three tasks together within one inference pipeline. A network with two coupled streams, built on a 3D U-Net, first reconstructs an enhanced uLF volume and then combines the original and enhanced images for subcortical segmentation. To improve boundary stability, we add an auxiliary class covering brain tissue outside the target structures, derived from whole brain masks. A head conditioned on an artifact graph predicts the seven artifact ratings from reconstruction residuals and frozen segmentation features. We address the scarcity of dense annotations using diffeomorphic registration from atlas to target for label propagation and to regularize anatomical reconstruction. We report validation results across all three tasks.

0.12

Asymmetric Paired-Annotation Learning for Multi-Structure ULF Pediatric Brain MRI Segmentation

cs.CV ·2026-09-02 ·Ha-Hieu Pham, Dang P. M. Cao, Minh Hoang Pham, Khanh Nguyen Vo Ngoc, Thanh-Huy Nguyen +2 more
publishedcode/data similarity 0.67
Abstract · Accepted at LISA Challenge, MICCAI 2026

Portable ultra-low-field (ULF) MRI can expand access to pediatric neuroimaging, but segmentation at 0.064 T remains challenging because anatomical boundaries are weakly delineated, small structures may be only partially visible, and high-field references can be locally misregistered. The LISA 2026 Challenge provides two non-equivalent annotations reflecting different sources of anatomical evidence: a highfield-derived (HF) mask defining the scored target and a low-field-edited (LF) mask aligned with visible ULF anatomy. In this challenge report, we describe AURA, an nnU-Net-based asymmetric supervision strategy that treats these annotations as distinct observations rather than interchangeable ground truths. AURA anchors training to the HF mask and incorporates the LF mask through a bounded reliability gate based on label disagreement, boundaries, predictive uncertainty, class reliability, and training stage. On a 16-case development split, the HF-supervised baseline, AURA, and their ensemble achieved Dice scores of 0.7984, 0.7950, and 0.7988, respectively, while the ensemble achieved an HD95 of 1.8892 and an ASSD of 0.7855. These results provide a preliminary evaluation of AURA within the LISA 2026 Challenge and motivate further assessment on the hidden test set and external ULF cohorts. Our code and pretrained models are available at https://github.com/minhdang050806/ A-nnU-Net-based-asymmetric-supervision-strategy.

0.61

M3-Score: Fidelity, Memorization and Coverage as Separate Axes for Evaluating Generative Radiology Image Models

cs.CV ·2026-09-27 ·Sathiyamohan Nishankar, Pubudu Sanjeewani, Asanka Perera
similarity 0.63
Abstract

Quantitative evaluation of generative models for radiology remains challenging. Clinically relevant structures are often small and infrequent, feature spaces learned from natural images may represent them poorly, and a single summary score cannot distinguish limited fidelity from limited diversity. This study proposes the Medical Multi-axis Maximum Mean Discrepancy score (M3-Score), an evaluation framework based on RadioDINO-s16, a frozen vision transformer pretrained on radiology images. M3-Score reports three complementary axes computed at pre-specified encoder depths: \emph{fidelity}, measured by an unbiased multi-bandwidth radial basis function (RBF) MMD$^2$ at the final block; \emph{memorization}, measured by nearest-neighbor distances at 75\% depth; and \emph{coverage}, defined as the fraction of real images with a generated neighbor within their $k$-nearest-neighbor radius at 33\% depth. Reference sets are sampled across subjects to limit the influence of correlated slices. On BraTS brain MRI, the fidelity axis ordered five comparison sets of increasing severity (Spearman $ρ= 1.00$), and a subject-disjoint real set yielded $\mathrm{MMD}^2 = 0$ (permutation $p = 1$). An unconditional denoising diffusion probabilistic model achieved $\mathrm{MMD}^2 = 0.073$ (95\% confidence interval $[0.071, 0.080]$) but covered only 38\% of the real distribution. Under progressive mode dropping, $k$-NN manifold recall increased at all twelve encoder blocks, whereas the proposed coverage estimator decreased monotonically ($ρ= -1.00$). RadioDINO-s16 features separated real brain MRI from generated samples with a ROC-AUC of 0.819, compared with 0.555 for InceptionV3 and 0.582 for CLIP. Across a twentyfold range of sample sizes, the mean M3 value varied by a factor of 1.05, compared with 2.52 for the Fréchet Inception Distance.

0.21

A generalizable structural brain MRI foundation model via dual-priority federated pretraining

cs.CV ·2026-09-23 ·Zhen Yu, Yang Liu, Jianfeng Feng, Xiahai Zhuang, Qingchao Chen
similarity 0.62
Abstract

Foundation models hold promise for generalizable analysis of structural brain magnetic resonance imaging (MRI) scans across diverse populations and imaging conditions. However, existing models typically rely on centralized pretraining using data pooled across cohorts, which is constrained by privacy and data-governance requirements. Moreover, larger cohorts can dominate optimization, underutilizing anatomical information from smaller cohorts and limiting generalization. Here we present BrainFedFM, a structural brain MRI foundation model federatively pretrained on 164,707 three-dimensional scans drawn from diverse real-world data distributions and organized across 42 federated sites. BrainFedFM uses dual-priority federated pretraining, in which spatial-priority masking emphasizes informative anatomical regions during local training, while site-priority aggregation adaptively weights contributions during global aggregation. Across 20 downstream datasets spanning 17 classification, regression and segmentation tasks, BrainFedFM achieved the state-of-the-art performance across seven foundation models, including four centralized models, while showing consistent advantages in classification and regression tasks and strong robustness under underrepresented populations and challenging imaging conditions. These findings demonstrate the generalizability of BrainFedFM and highlight federated pretraining as a practical strategy for developing neuroimaging foundation models from distributed data without pooling raw images.

0.25

Evaluating the Generalization of Neuroimaging Foundation Models on African Brain MRI

cs.CV ·2026-09-21 ·Oluwatobi Iyanuoluwa Akinmuleya, Olatokun Shamsudeen Akano, Samuel Danquah Ankapong, Olamide Lawal, Toufiq Musah
published similarity 0.62
Abstract · MICCAI AFRICAI Workshop, Strasbourg, France, 2026, 10 Pages, 1 Figure, 2 Tables

Neuroimaging foundation models pretrained on large, predominantly western cohorts are increasingly proposed as general-purpose backbones for brain MRI analysis. Yet, their ability to generalize to underrepresented clinical populations remains largely untested. We evaluate four recent foundation models (BrainIAC, Neuro-JEPA, NeuroVFM, and Primus) on a three-way diagnostic classification task (Control, Dementia, Parkinson's disease) using a cohort of 88 subjects from a Nigerian clinical brain MRI dataset, across four modality configurations (T1w, T2w, T1w+T2w, FLAIR), and compare against an end-to-end trained ViT3D baseline. The frozen backbones collapse to majority-class predictions, while Neuro-JEPA on FLAIR shows modest but still limited discrimination. In contrast, the end-to-end trained ViT3D achieves higher accuracy and MCC on every task (up to 53.4% accuracy, MCC=0.27) and is the only model with non-trivial recall. Our findings suggest that these frozen neuroimaging foundation models are insufficient for fine-grained diagnostic classification in small, non-western clinical cohorts, motivating parameter-efficient adaptation and broader multi-site external validation for equitable deployment in global health settings.

0.29

Task-Adaptive 3D Cross-Field MRI Translation via Field-Conditioned Content-Style Pretraining

cs.CV ·2026-08-10 ·Haowen Pang, Yingqi Hao, Pengli Zhu
publishedcode/data similarity 0.62
Abstract · MICCAI 2026 Workshop on MRIxFields

Magnetic field strength is a major source of domain shift in magnetic resonance imaging (MRI), affecting signal-to-noise ratio, tissue contrast, spatial detail, and the visibility of anatomical boundaries. The MRIxFields 2026 challenge investigates this problem through cross-field MRI translation across acquisitions at 0.1T, 1.5T, 3T, 5T, and 7T. Its three tasks, Any-to-7T, 0.1T-to-High, and Any-to-Any synthesis, require the generation of target-field image characteristics while preserving subject-specific anatomy. This problem is particularly challenging because paired acquisitions of the same subject across multiple field strengths are rarely available for training. We propose a 3D unpaired cross-field MRI translation framework based on field-conditioned content-style pretraining. The proposed framework first learns controllable field-to-field translation across all available field strengths by disentangling anatomical content from field-dependent contrast characteristics. The pretrained backbone is then adapted to task-specific target domains. Our model comprises a 3D content encoder, a 3D style encoder, a field-conditioned style generator, an AdaIN-modulated decoder, and a multi-field discriminator. Adversarial learning encourages realistic target-field appearance, while cycle-consistency, identity, content, style, and diversity constraints promote anatomical fidelity and controllable translation. We evaluate the proposed method on MRIxFields data spanning five field strengths and three MRI modalities. Experiments on paired test data demonstrate that the framework can adapt to the three challenge settings while preserving three-dimensional anatomical structure in the synthesized volumes. The implementation code is publicly available at https://github.com/Idea89560041/3D-MRI-Field-Translation.

0.71

VoxForge: A Unified Foundation Model for Dense 3D Features Across MRI, CT and PET

cs.CV cs.LG ·2026-11-19 ·Rushil Anirudh, Jayaraman J. Thiagarajan
similarity 0.60
Abstract · 34 pages (8-page main paper, references, and 23-page supplementary material), 7 figures. Rushil Anirudh and Jayaraman J. Thiagarajan contrib…

A unified 3D medical foundation model promises reusable, frozen features that serve a wide variety of tasks such as segmentation, classification and registration on MRI, CT and PET as well as specialist models do. Generalist models still need separate backbones for localized and global tasks, specialist models are confined to a single modality, with the concern that spanning modalities under-emphasizes fine anatomy, and both typically rely on end-to-end fine-tuning to be competitive. We present VoxForge, a single encoder that integrates recent advances in 3D architecture, self-distillation and cross-modal curricula to learn transferable features from permissively licensed MRI and CT volumes. We evaluate it strictly frozen, the test a reusable foundation model must pass, against state-of-the-art generalist and specialist models on segmentation, classification and registration across MRI and CT, and on PET, which it never sees. VoxForge has the best or tied-best average rank in every task group, serves localized and global tasks across modalities at the level of state-of-the-art specialists, and is extremely label-efficient, matching top-performing models on TotalSegmentator CT with a tenth of the labels.

0.17

nnFoundation: 3D Foundation Models for Radiology

cs.CV eess.IV ·2026-09-22 ·Constantin Ulrich Harsy, Tassilo Wald, Karol Gotkowski, Yannick Kirchhoff, Marcel Knopp +78 more
highly cited similarity 0.60
Abstract

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

0.42