CS Paper Radar

PhenoBench: Mapping What a Deeply Phenotyped Human Cohort Can Tell Us

Gal Sapir, Alon Diament, Adva Wolf, Doron Yaya-Stupp, Dikla Gelbard Solodkin, Dana Azouri, Anat Etzion-Fuchs, Guy Lutsker, Eran Segal, Hagai Rossman

cs.LG cs.AI ·submitted 2026-09-05 13:15 UTC · v2
benchmarkcode/data

Abstract

Deeply phenotyped cohorts combine clinical, imaging, molecular, and wearable observations across timescales from seconds to years, but heterogeneous analyses are not directly comparable. We present PhenoBench, an executable benchmark that turns deep-phenotyping measurements into explicit questions and controlled comparisons of information sources and predictive models. It is built around the Human Phenotype Project, with more than 13,000 participants at the initial visit. Each question fixes the target, population, timing, and allowed information; its evaluation contract specifies the split, metric, baseline, and claim boundary. PhenoBench defines 90 clinically grounded tasks across 15 domains and 26 input modalities. Across 160 matched regression comparisons spanning 52 tasks, six pretrained tabular models ranked above the evaluated task-specific baselines, including XGBoost and CatBoost, under a fixed single-estimator protocol with bounded tuning. Giving each task equal weight, their mean advantage over ridge was 0.0103 $R^2$ (95% task-bootstrap interval, 0.0071-0.0136). We also evaluated 14 language models, collectively covering 40 tasks spanning phenotype recovery, classification, follow-up forecasting, and participant ordering. Without cohort-specific fitting, language models made informative predictions on some tasks but showed task-specific capability gaps, shared failures of scale, and rarely surpassed task-specific ridge or logistic regression models fitted on the same input fields. PhenoBench provides a versioned, auditable evaluation system where new questions, measurements, and models can be added without redefining existing comparisons.

Comment
35 pages; 4 main figures, 5 supplementary figures, and 1 extended-data figure. Expanded model comparisons; corrected paired summaries; clarified evaluation protocols and limitations. Project website: https://galsapir.github.io/phenobench-benchmark/ . Code and benchmark materials: https://github.com/galsapir/phenobench-benchmark

Closest papers

Nearest neighbours by meaning across the whole index.

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

cs.LG ·2026-08-13 ·Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala +1 more
benchmark similarity 0.64
Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

0.04

PPG-Bench: A Unified Benchmark for PPG Foundation Models

cs.LG ·2026-10-09 ·Arvasu Kulkarni, Mahir Jain, Aditya Ray Mishra, Sandeep Singh, Siddharth Panwar
benchmarkcode/data similarity 0.64
Abstract

Photoplethysmography (PPG) is increasingly recorded by wearable and clinical devices at enormous scale, and a growing number of PPG foundation models (FMs) have been developed to compute reusable representations for various downstream tasks. These models are difficult to compare: different evaluations use different datasets, task definitions, preprocessing, downstream heads, hyperparameter tuning, and baselines. We present PPG-Bench, a unifying open-source benchmark evaluating five public PPG FMs across nine open-access datasets and 26 tasks spanning cardiovascular state estimation, activity, sleep, screening, and identification. We evaluate models under four downstream regimes of increasing adaptability (linear probing, random forests, frozen MLP probes, and end-to-end finetuning), with model-specific hyperparameter optimization and subject-disjoint cross-validation. We also evaluate against three controls: random/constant baseline, a deterministic pulse-rate-variability (PRV) feature set, and a generic time-series FM (MOMENT). Across all 68 task-regime combinations, 35.3% show no meaningful FM advantage over the random/constant baseline, and in 83.8% no PPG-specific FM outperforms both PRV and MOMENT. We also find that added downstream head capacity generally improves performance, but can cause significant degradation if the model is performing at chance/constant level. Current PPG FMs therefore cannot yet claim to provide generalised and transferrable representations of PPG signals, and future evaluation in this field should include checks against simple, non-learned controls. Code for the benchmark and instructions to evaluate more models can be found here - https://github.com/mannas-ai/ppg-bench.

0.31

TRACE: Tracking Multimodal Clinical Trajectories for Inpatient Risk Prediction

cs.AI ·2026-10-19 ·Minjun Kim, Jong Hak Moon
similarity 0.60
Abstract · 14 pages, 4 figures

Accurate inpatient risk prediction requires modeling heterogeneous clinical evidence that accumulates irregularly over time. This challenge spans in-hospital mortality, prolonged length of stay, and readmission, each with task-specific observation windows. Existing multimodal approaches combine structured health record data, chest x-rays, and clinical text, but primarily focus on modality fusion or missing-modality compensation, with limited attention to temporal trajectories over an admission. We propose TRACE (TRAjectory modeling of multimodal Clinical Events), a daily-scale framework organizing clinical events into day-level trajectories, separating day-invariant global context from day-specific local events drawn from EHR data, chest x-rays, radiology reports, and discharge summaries. The trajectory is encoded using temporal attention, allowing unavailable modalities to emit no tokens. A phenotype-guided contrastive objective further organizes admissions under heterogeneous disease distributions. Across cohorts from MIMIC-IV, eICU, and MIMIC-III comprising nearly 180,000 total stays, we evaluate TRACE on mortality, length of stay, and readmission prediction. TRACE achieves the highest AUROC across all nine dataset-task settings and the highest ACC in eight, outperforming baselines. Ablation studies validate our attention masks and contrastive learning, while trajectory-level attribution localizes risk-associated hospital days and modalities.

0.29

TabBioMed: A Large-Scale Benchmark for Biomedical Tabular Learning

cs.LG ·2026-11-18 ·Pau Mateo-Bernadó, Saivenkata Nagavyjayanthi Polapragada, David Bonet, Pol Arbiol Rakuljic, Laia Mogas Pladevall +6 more
publishedbenchmarkcode/data similarity 0.60
Abstract · 87 pages, 43 figures, including appendices and the NeurIPS paper checklist

Recent advances in machine learning have accelerated biomedical prediction, but evaluation on structured biomedical data remains fragmented, especially for datasets with high dimensionality, large sample size, missingness, and class imbalance. We introduce TabBioMed, a large-scale benchmark of 94 curated public biomedical tabular datasets spanning electronic health records, drug discovery, genomics, transcriptomics, proteomics, metabolomics, single-cell omics, and systems biology. TabBioMed unifies these datasets through a standardized, dataset-aware preprocessing and evaluation framework, enabling reproducible comparison across classification, regression, and multi-target tasks. We benchmark 23 models across classical baselines, gradient-boosted trees, neural tabular architectures, and tabular foundation models. Foundation models deliver the strongest family-level predictive performance. However, their gains are regime-dependent: tree-based models and tuned multilayer perceptrons remain highly competitive, often dominating under inference-time or training-cost constraints. Overall, TabBioMed shows that biomedical tabular learning is strongly context-dependent, with optimal model choice depending on data regime, task type, and computational budget. We release TabBioMed with curated datasets and splits, preprocessing code, baselines, and results, providing a reproducible benchmark for practical model selection and future methods development in biomedical machine learning, available at https://github.com/AI-sandbox/TabBioMed.

0.44

Kolmogorov-Arnold Networks vs. Multi-Layer Perceptrons: A Rigorous Statistical Benchmark on Clinical Tabular Data

cs.LG cs.AI ·2026-11-02 ·Rafał Wodziński, Paweł Szczerbiak
benchmarkcode/data similarity 0.60
Abstract · 18 pages, 9 figures, 6 tables

Kolmogorov-Arnold Networks (KANs) have recently been proposed as a promising alternative to Multi-Layer Perceptrons (MLPs). However, empirical evaluations on structured medical datasets remain scarce, and commonly reported metrics like AUROC can yield overly optimistic performance estimates on imbalanced clinical cohorts. In this study, we present a standardized benchmark comparing eleven architectures - nine KAN variants (FastKAN, WavKAN, ReLUKAN, ChebyKAN, TaylorKAN, GramKAN, JacobiKAN, LegendreKAN, and TabKAN), a tuned StandardMLP, and a Random Forest baseline - across seven heterogeneous medical tabular datasets spanning oncology, cardiology, nephrology, neurology, endocrinology, and obstetrics. Our experimental protocol employs a 3x5 Repeated Stratified K-Fold cross-validation scheme with nested Bayesian hyperparameter optimization and evaluates discrimination via Area Under the Precision-Recall Curve (AUPRC), calibration through the Brier Score, and computational efficiency. Formal equivalence testing is conducted using the Bayesian Correlated t-Test with a Region of Practical Equivalence (ROPE) at +/- 0.01. The results indicate that on datasets with severe class imbalance, dedicated KAN architectures (particularly TabKAN and ReLUKAN) can improve minority-class detection and achieve higher AUPRC than standard MLPs. Nevertheless, across pooled datasets, KAN variants demonstrate comparable overall predictive discrimination rather than a systematic advantage, while requiring 1.20x to 1.48x longer inference latency per sample and up to 12.5x more trainable parameters. Consequently, StandardMLP remains a strong baseline on the efficiency Pareto frontier, while KAN variants provide a viable alternative when precision on rare positive cases is the primary clinical objective. The code for reproducing the results is available at https://github.com/rafalwodzinski/kan_mlp_comparison.

0.31

TabBench-Bio: A Living Benchmark for Machine Learning on High-Dimensional Biomedical Tables

cs.LG cs.AI ·2026-09-07 ·Jules Kreuer, Sofiane Ouaari, Julia Hellmig, Julius Braitinger, Nico Pfeifer
benchmark similarity 0.59
Abstract

Biomedical tables often combine thousands of measured variables with only tens or hundreds of labelled samples, a regime that is poorly represented in general-purpose tabular benchmarks. We introduce TabBench-Bio, a living and interactive benchmark of 43 biomedical datasets spanning multiple domains. Under a shared cross-validation protocol, we compare classical estimators, neural networks, and tabular foundation models across 28 feature-by-sample operating points. At the reference cell of 10,000 features and 100 training samples, RealTabPFN 2.5 has the highest point estimate, closely followed by TabPFN 3 and Logistic Regression. A paired bootstrap over the target pool separates RealTabPFN 2.5 from TabPFN 3 by 87 Elo (95\% interval [43, 129]). Tabular foundation models generally occupy the leading ranks, while the strongest configuration depends on the operating point and biomedical modality. The AutoML framework AutoGluon, using its one-hour "extreme" preset, is configured as a separate resource-intensive reference and reported here at the reference and full cell. Fold-level predictions, run status, and deterministic aggregations make every reported result reproducible and reusable. The benchmark is open to contributions of new biomedical datasets. The interactive leaderboard is available at https://tabbench-bio.eu.

0.38

Explainable Transformer Models for Clinical Prediction Tasks on Structured Electronic Health Records

cs.LG ·2026-08-20 ·Jun Ni Du, Lukas Adamek, Maxim Kryukov, Flavio Dormont, Ziv Bar-Joseph +2 more
top venuebenchmark similarity 0.59
Abstract · Accepted at MLHC 2026; to appear in Proceedings of Machine Learning Research (PMLR)

Predictive models over structured electronic health records (EHRs) remain central to machine learning for healthcare, but few have jointly emphasized quantitative laboratory information and interpretability with respect to input medical events. We present BERT-LER, a BERT-style model for coded EHR timelines pretrained and fine-tuned from a de-identified EHR dataset of 75 million patients, that encodes laboratory test results as discrete tokens while retaining graded information through percentile-based binning, paired with Integrated Gradients for token-level attributions grounded in the input EHR sequence. We benchmark our approach on the public EHRShot benchmark suite and on an asthma severity progression study based on real-world data. This addresses a methodological gap in EHR foundation-style modeling by unifying laboratory value representation and explainability in a single framework, while assessing whether both predictive performance and explanations generalize beyond standard clinical prediction tasks. Across EHRShot and asthma tasks, BERT-LER achieves predictive performance that is competitive with, and on laboratory-related tasks often exceeds, publicly available benchmark models, and provides attributions that align with clinically known risk factors. Our architecture and explainability approach can be applied to many therapeutic areas and prediction tasks using language models trained on structured EHRs.

0.42

Repeated-Measure Leakage, Distribution Shift, and Reliability under Partial Observation in Patient World Models

cs.LG ·2026-10-03 ·Arjun Subramanian
publishedcode/data similarity 0.59
Abstract · 13 pages, 7 figures. Selected for oral presentation at the NeurIPS 2026 Workshop on World Models for High-Stakes Health (WMHS) Replication P…

Patient world models are increasingly proposed for longitudinal prediction, intervention-aware reasoning, and clinical-trial simulation. Causal or clinical intervention validity is distinct from predictive generalization and reliability; before making stronger claims, the underlying predictive state should generalize across patients, survive realistic shifts and missing observations, and expose failure through meaningful reliability signals. We evaluate these prerequisites in a deliberately narrow setting: short-horizon digital-biomarker forecasting from PhysioNet GaitPDB, comprising 165 participants, 306 recordings, and 51,129 context-future pairs. Using persistence, ridge, MLP, GRU, Transformer, and a compact JEPA-style predictor, we build an evaluation ladder that progressively removes raw temporal overlap, same-recording familiarity, and same-patient familiarity before testing unseen-patient generalization. For GRU, NMSE rises from 0.1227 under random-window splitting to 0.1393 after eliminating raw train-test overlap and to 0.1961 under patient holdout. Among 54 participants with repeated recordings, exposure to a different recording from the same patient improves GRU NMSE from 0.2177 to 0.1556, while a recording-excluded identity hypothesis is not supported at the participant level. Under participant-held-out evaluation, MLP and Transformer are statistically indistinguishable. Study shift, a four-times-longer prediction gap, and partial observation further degrade performance; under 50% temporal masking, Transformer NMSE rises to 0.611 while MC-dropout predictive variance falls. We do not claim a longitudinal or intervention-aware simulator. Instead, the results support a prerequisite evaluation stack of patient separation, repeated-measure controls, shift, missingness, and uncertainty validation before stronger patient-world-model claims are trusted.

0.39