CS Paper Radar

OCTN: Neural OCT Representations for Robot-Guided Precision Intervention

Ravi Prakash, Ryan P. McNabb, Patrick J. Codd, Shan Lin

cs.RO ·submitted 2026-09-06 20:01 UTC · v1
code/data

Abstract

Optical coherence tomography (OCT) offers compact, contactless, micron-scale imaging suitable for intraoperative guidance, but native OCT volumes are discretely sampled, anisotropic, and currently inefficient for downstream geometric reasoning and robot integration. We present OCTN (pronounced "octane"), an implicit neural representation framework that converts volumetric OCT scans into a continuous, differentiable, and spatially faithful tissue-intensity field. OCTN uses a two-stage hybrid training strategy that combines supervision from acquired voxels with inter-slice interpolations, preserving B-scan fidelity while improving continuity in sparsely sampled regions. For versatility, we first show that OCTN enables fast volumetric reasoning by storing the learned tissue representation natively on the GPU, supporting intensity-based spatial queries with up to 43x speedup over conventional CPU processing. We then demonstrate OCTN-enabled OCT-guided robotic laser surgery where the continuous tissue representation supports implicit surface discovery and surface-constrained path planning via multiple optimization strategies, including Newton- and SGD-based optimization. Next, OCTN enables reconstruction of dense volumetric structure from sparsely acquired B-scans, while reducing acquisition time by 4x and preserving clinically relevant structures. Across the newly generated Duke TissueOCT dataset and public OCT datasets, OCTN achieves robust, high-fidelity reconstruction with PSNR > 30 dB and training time < 10 s, while preserving surface consistency within 10 $μ$m Chamfer distance relative to baseline reconstruction. The TissueOCT dataset and code are publicly available at raprakashvi.github.io/octn

Closest papers

Nearest neighbours by meaning across the whole index.

Robotic Optical Coherence Tomography-Guided Geometric Modeling of Soft Tissue: 3D Representations for Data-Driven Closed-Loop Shape Control

cs.RO ·2026-10-23 ·Chaoyu Zhang, Guangshen Ma, Mark Draelos
similarity 0.81
Abstract · 30 pages, 18 figures

In medical robotics, data-driven soft-tissue shape control requires deforming tissue toward desired morphologies through sequential physical interactions. This challenge is particularly important in microscale manipulation, where localized deformation is difficult to observe, represent, and control, while physics-based models can be computationally expensive and difficult to adapt to realistic environments. Optical coherence tomography (OCT) provides high-resolution volumetric perception of tissue deformation, but target-conditioned control requires effective representations of both observed and desired tissue states. In this work, we introduce an OCT-guided data-driven framework for tissue shape control, learned from user-guided demonstrations and executed with closed-loop OCT feedback. We study full-volume, tissue-masked sparse-volume, and voxelized point-cloud representations, with or without residual conditioning, using deterministic (Explicit) and generative diffusion (Diffusion) policies. Across 12 configurations and 576 phantom rollouts on 3-DoF depth and 6-DoF directional tasks, OCT-derived 3D representations support both Explicit and Diffusion policies, with performance depending on representation and residual conditioning. Residual conditioning reduces directional Shape RMSE from 0.748 to 0.555 mm for full-volume Diffusion, while voxelized point-cloud Explicit with residuals achieves 0.534 mm for depth and 0.443 mm for directional control, with comparable accuracy at intermediate unseen targets and consistent performance across deployments. We further evaluate the framework in 60 ex vivo porcine rollouts, extending to biological tissue with final geometric errors comparable to human demonstrations. These results establish volumetric OCT as current and goal representations for learned closed-loop tissue shape control across deterministic and generative action models.

0.07

An Anatomy-guided 3D Segmentation Pipeline for Prostate Surgical Phantoms from CT Scans

cs.CV ·2026-11-05 ·Iven Chen, Kuan-I Chung, Ayberk Acar, Susheela Sharma Stern, Alejandro O. Chara +2 more
similarity 0.68
Abstract · 11 pages, 2 figures, 3 tables, 10 algorithms. Extended abstract accepted at SPIE Medical Imaging 2027: Image Processing

Full autonomy has been a long-term goal in robotic surgery and a near-to-medium-term goal for prostatectomy. Due to the relatively closed structure of the procedure, its standard-of-care robotic/laparoscopic solutions, and procedure economics, prostate procedures are an optimal early target for surgical automation. Prototyping and testing of possible solutions is done in constructed laboratory phantoms, either synthetic tissues or animal phantoms. To enable measurement of perceptual and robotic motion error, phantoms undergo volumetric imaging; these images are critical to both a potential deployed automatic system, used in planning motion and treatment (cutting, ablation, suturing, etc.), as well as post-hoc assessment of system performance. Rapid iteration on these phantom models yields small, inconsistent datasets, while the current workflow for human annotation is often anatomically unreliable and prohibitively time-consuming, rendering deep learning unsuitable at reasonable scales. To address these limitations, we present an automated 3D segmentation pipeline that uses classical medical image-processing techniques to encode the known anatomy of the phantoms as explicit geometric and intensity priors, which requires no training corpus and is transferred to each new phantom revision without re-annotation. Across 57 scans spanning multiple phantom revisions, our pipeline recovers the capsule interior at 0.83 median Dice on 11 contrast-suppressed scans and detects all 32 annotated focal lesions without false positives, completing a full scan in 2-8 minutes on commodity CPU hardware versus 1-2 hours by hand.

0.35

Steer the Sampling, Not the Kernel Grid: Geometry-Guided Sampling Operator for Volumetric Segmentation

cs.CV ·2026-08-26 ·Sizhe Wang, Himashi Peiris, Zhaolin Chen
top venue similarity 0.66
Abstract · Accepted at MICCAI 2026

Accurate 3D segmentation is central to quantitative lesion assessment and anatomy mapping for clinical planning and follow-up. Thin, elongated, and fine anatomical/pathological structures (e.g., vessels) are a particularly challenging case: a one-voxel boundary error can disconnect a branch and change clinically relevant topology. In encoder-decoder networks (e.g., U-Net), repeated downsampling and fixed-grid convolution blur or alias fine structures and weaken orientation cues, so early mistakes propagate across scales. We propose a geometry-guided local operator that steers where features are sampled, rather than deforming convolutional kernels, under a single formulation for both feature refinement (stride 1) and resolution reduction (stride > 1). At each voxel, it predicts a local orientation and bounded step sizes, samples symmetrically along these directions, and transforms paired samples into compact geometric and boundary cues with lightweight mixing; a cross-scale consensus aligns encoder and decoder features at skip connections to reduce geometric mismatch. Replacing all stride 1 and stride 2 operators in a 3D U-Net yields consistent improvements on BraTS, MSD Hepatic Vessel, and TDSC-ABUS, with notably better boundary metrics (e.g., BraTS Dice 86.1 to 88.9, HD95 7.1 to 6.2; TDSC-ABUS HD95 39.1 to 27.8) while reducing parameters from 2.3M to 0.8M. We further demonstrate that the operator can be integrated into other backbones (e.g., nnU-Net, Swin-UNETR, and MedNeXt) without changing their macro-architectures while providing consistent performance gains.

0.24

Pix2Rep-v2: Data-Efficient Representation Learning for Dense Medical Imaging Applications

cs.CV ·2026-09-01 ·S. Sifaoui, E. Angelini, S. Toupin, T. Pezel, L. Le Folgoc
top venuecode/data similarity 0.65
Abstract · Accepted at MICCAI 2026

Dense self-supervised learning (SSL) is a powerful paradigm for learning without annotations the local descriptors required to solve dense medical imaging tasks. We present Pix2Rep-v2, a framework for SSL of pixel- and voxel-level representations suitable for few-shot downstream applications. Pix2Rep-v2 addresses the main challenges of dense SSL by leveraging a redundancy reduction objective at the pixel-level with a principle of equivariance of dense representations, that scales efficiently to 3D or wide field-of-view applications. We evaluate our method on four datasets, across multiple tasks, multiple modalities and anatomical structures using multiple backbones in 2D and 3D, and under various data regimes. As an alternative to linear probing or full fine-tuning on the downstream task, we also propose an in-context variant, without downstream training, based on a dense prototype approach. Pix2Rep-v2 shows substantially higher data-efficiency in few-shot scenarios compared to fully supervised baselines, and is competitive with the state-of-the-art e.g., +9.3 Dice points in one-shot segmentation on the M&Ms-2 dataset. Our code and pre-trained models are publicly available at https://github.com/BioMedTP/pix2rep-v2.

0.76

Occupancy Network-Guided Autonomous Robotic Partial Nephrectomy

cs.RO cs.CV ·2026-09-14 ·Ethan Kilmer, Pit Henrich, Jiawei Ge, Paul M. Scheikl, Laura Connolly +11 more
top venue similarity 0.65
Abstract

Autonomous soft-tissue cancer surgery has been limited to interventions on organ surfaces, because current systems cannot perceive and adapt to anatomy once it deforms or is cut. We introduce the first vision-guided autonomous system capable of performing complete tumor resections for partial nephrectomy. Our system integrates conditional occupancy networks, trained entirely in a physics-based simulation, that infer full 3-D anatomy (tumor, margin tissue, and kidney) from single-view partial point clouds. These occupancy networks maintain intraoperative tracking even as tissue is cut and deformed, enabling adaptive planning and execution. The surgical platform combines a depth camera for capturing surface point clouds, dual robotic arms for electrosurgical cutting and vacuum-based tissue manipulation, and an autonomous control strategy for tumor resection. In patient-derived hydrogel phantoms under an open partial nephrectomy setting, the robot performed eight consecutive autonomous tumor resections comprising 77 electrosurgical cuts, with all cuts achieving negative surgical margins and 1.61 $\pm$ 0.48 mm mean absolute margin error. This work demonstrates, for the first time, a foundation for supervised autonomous closed-loop, imaging-driven, margin-negative tumor removal in phantoms.

0.30

Where to Look Matters: Rethinking Sub-Volume Sampling in 3D Medical Self-supervised Learning

cs.CV ·2026-10-09 ·Junkai Liu, Le Zhang
publishedcode/data similarity 0.64
Abstract · NeurIPS 2026. Project page: https://volumeprobe.github.io/

Self-supervised learning on 3D medical images commonly relies on random sub-volume sampling during pretraining. However, random cropping implicitly treats all spatial regions as equally worth observing, despite anatomical priors and spatial redundancy that make regions inherently unequal in their value for representation learning. To this end, we first show through controlled crop-quality manipulations that better sub-volumes lead to better downstream transfer, revealing the observation policy as an overlooked bottleneck in 3D medical SSL. Motivated by this finding, we revisit sub-volume sampling as a where-to-look problem. We propose VolumeProbe, a plug-and-play framework that replaces random cropping with an offline coarse-to-fine probe bank guided by anatomy-awareness, informativeness, and diversity. We instantiate VolumeProbe as a lightweight Lite variant using geometric and image-statistical cues, and a diagnostic Feat variant using frozen visual features, to examine whether lightweight volume-intrinsic priors suffice or richer semantic cues reliably provide additional value. Extensive experiments across multiple 3D medical SSL backbones and downstream tasks demonstrate that VolumeProbe-Lite consistently improves transfer performance over random sampling. Mechanistic analyses further link these gains to more anatomically plausible and informative observations, reduced spatial redundancy, more efficient learning dynamics, and more structured representations.

0.22

CRESSim-Neo: A Batched GPU Simulation Engine for Surgical Robotics and Robot Learning

cs.RO ·2026-08-25 ·Yafei Ou, Ahnaf Naheen, Tleukhan Mussin, Hans Jarales, Melwin Chacko Moncy +1 more
similarity 0.63
Abstract · 8 pages, 11 figures

We introduce CRESSim-Neo, a batched GPU simulation engine for surgical robotics and robot learning. CRESSim-Neo combines position-based simulation of rigid bodies, deformable tissues, fluids, and strands with batched rendering, surgery-specific sensing, and a GPU-resident data pipeline. The engine supports applications including tissue manipulation, fluid suction, suturing, cable-driven robots, and ultrasound image synthesis. Direct access to physics and rendering buffers enables GPU-resident robot learning and zero-copy PyTorch integration using DLPack. We demonstrate CRESSim-Neo across rigid-body, deformable-body, and fluid simulation tasks, including vision-based and surgical robot-learning scenarios. On an NVIDIA RTX 4090, the engine achieves up to 2.03 million environment steps per second for 8192 parallel CartPole environments, and scales to batched surgical scenarios involving tissue deformation, fluid interaction, and ultrasound sensing. Overall, CRESSim-Neo provides a unified and scalable platform for surgical simulation, synthetic data generation, and surgical robot learning.

0.27

MedGSSR: Generalizable Medical Image Super-Resolution 3D Reconstruction via Hierarchical Feed-forward Gaussian Splatting

eess.IV cs.CEcs.CVq-bio.QM ·2026-09-06 ·Chengkai Wang, Luoyu Hong, Yiting Zhao, Jiamin Wang, Xiang Feng +5 more
top venue similarity 0.63
Abstract · ECCV 2026

High-resolution volumetric medical imaging is critical for clinical diagnosis, yet acquisition is often limited by scanner hardware, scan time, and for CT, radiation dose. Medical 3D Super-Resolution (Med3DSR) offers a computational alternative, but existing methods commonly rely on per-subject optimization, pretrained priors, or coordinate-based implicit representations, which compromise anatomical fidelity and limit efficiency. To address these limitations, we present MedGSSR, a fully end-to-end feed-forward framework that represents volumes as an explicit 3D Gaussian field for Med3DSR. Unlike coordinate-based implicit functions, our explicit 3D Gaussian representation naturally enhances signal continuity and local high-frequency fidelity. Specifically, MedGSSR explicitly decouples the reconstruction process into coarse-grained structural preservation and fine-grained textural refinement through the proposed Pyramid Anatomical Encoder and a Hierarchical Gaussian Projector. To support arbitrary-scale super-resolution, we introduce sub-voxel Gaussian decomposition and a Differentiable Gaussian Voxelizer that directly queries the continuous 3D intensity field, reducing discretization artifacts. Extensive experiments on MRI and CT benchmarks demonstrate that MedGSSR significantly outperforms state-of-the-art methods. Notably, our framework exhibits robust generalizability across unseen datasets without requiring per-subject optimization, enabling fast inference and high-fidelity volumetric super-resolution in practical clinical settings. Our project webpage, including code, is at https://william2ai.github.io/medgssr

0.66