CS Paper Radar

Data-driven estimation of design heating loads for HVAC equipment sizing

Alex H. Lee, Elias N. Pergantis, Kevin J. Kircher

eess.SY ·submitted 2026-09-07 15:23 UTC · v1

Abstract

Oversized heating and cooling equipment can unnecessarily increase up-front costs, energy costs, pollutant emissions, and strain on electrical infrastructure. This paper develops two data-driven methods for estimating heating loads at design conditions to improve equipment sizing. One method uses smart thermostat data; the other uses utility bills. We test the methods on a dataset that we gathered from 74 detached single-family houses in five United States climate zones. The dataset includes smart thermostat time-series data, monthly utility bills, weather data, existing equipment specifications, and Manual J design load calculations (the United States industry standard) purchased from practitioners. The two methods have strong goodness-of-fit statistics individually and show fair agreement with each other. On average over the 74 houses, existing heating equipment is 2.75 (2.5th to 97.5th empirical percentile: 1.34-6.52) times larger than the thermostat-method estimate and 2.96 (1.36-7.76 times larger than the bill-method estimate. As implemented by practitioners, the Manual J estimate is 2.26 (0.87-5.21) times larger on average than the thermostat-method estimate and 2.35 (1.02-5.28) times larger than the bill-method estimate. We discuss prospects for implementing the data-driven methods at scale and for incorporating data-driven sizing into industry standards.

Closest papers

Nearest neighbours by meaning across the whole index.

Adjacent Heat Transfer Effects Can Bias Savings Estimates When Controlling Only Part of a Multi-Zone Building

eess.SY ·2026-11-12 ·Arash J. Khabbazi, Kevin J. Kircher
publishedtheory similarity 0.66
Abstract · 10 pages. Accepted at the 2027 ASHRAE Winter Conference

Field demonstrations of advanced heating, ventilation, and air-conditioning control often operate a few thermal zones within a larger building and report savings for those zones alone. A recent theorem showed that this practice overestimates whole-building savings, because heat drawn from the neighboring zones is paid for by their equipment and is not counted. The error grows with the thermal conductance between the controlled and uncontrolled zones, with how much colder the controlled zones run over the test, and with the price of the heat their neighbors supply. For one controlled zone with one neighbor, a single thermal price, and slowly changing prices, the relative error reduces to the ratio of two conductances, a screening number that can be evaluated from the two conductances before a demonstration begins. This paper tests how far that reduction can be taken. A two-story house with one thermal zone per floor is simulated over a 90-day heating season in West Lafayette, Indiana, with receding-horizon model predictive control on the first floor and setpoint control on the second, under four combinations of electricity tariff (time-of-use or flat) and heating plant (heat pump or electric resistance). The exact correction from the theorem recovers the true savings in every case, and the full theorem, evaluated from the controlled zone's temperatures, the prices, and the building parameters, reproduces the measured relative error in every case. The conductance ratio bounds that error from above in all four cases, tightly under a flat tariff, within 3%, and loosely under a time-of-use tariff, where most of the controller's savings come from shifting load through the thermal mass rather than from lowering the temperature.

0.30

Comparative review of hybrid forecasting models for short-term prediction of building thermal load

cs.LG cs.AI ·2026-09-19 ·Nikolaos A. Efkarpidis, Despoina Kothona, Georgios C. Christoforidis
similarity 0.62
Abstract · 27 pages, 15 tables, and 13 figures

In this paper, a comparative review of different hybrid models for short-term forecasting of building thermal demand is carried out. Particularly, the assessment tackles the comparison of data-driven models enhanced with other state-of-the-art techniques. At the first step, the existing techniques reported in the literature are analysed. It is concluded that Metaheuristics or a data-driven model are used to identify the parameters of the basic model. The qualitative evaluation includes for each method the input and output features, main advantages and drawbacks. At the second step, an existing dataset of historical thermal demand from Scottish households, as well as historical weather forecasts are utilized to assess additionally the performance of existing hybrid methods. From the assessment of 13 hybrid methods, the Empirical Modal Decomposition - long short-term memory - Markov (EMD-LSTM-Markov) model can predict with the highest accuracy the day-ahead power pattern of heating and domestic hot water (DHW) demands. Though local power peaks are also accurately predicted, high power swells and spikes are underestimated. Other methods, such as Support Vector Machine - Simulated Annealing (SVM-SA) and Random Forest - Improved Sparrow Search Algorithm - LSTM (RF-ISSA-LSTM) predict a smooth pattern of heating and DHW demand profiles with rapid changes underestimating most power peaks.

0.28

LoaDiff: Conditional Generation of Electricity Consumption Time Series for Energy Analytics

cs.LG cs.AIeess.SP ·2026-09-10 ·Mariia Baranova, Adrien Petralia, Etienne Le Naour, Nathan Etourneau, Guillaume Hofmann +1 more
top venue similarity 0.60
Abstract · 10 pages, 5 figures. This paper appeared in IEEE ICDM 2026

The energy transition is reshaping residential electricity consumption through the increasing adoption of distributed generation, electrified appliances, and demand-response programs. Understanding these evolving behaviors requires access to granular smart-meter data for applications such as load forecasting, appliance detection, and demand-side flexibility analysis. However, such data are subject to strict access restrictions and data-protection regulations. Thus, realistic synthetic alternatives are necessary. In this paper, we introduce LoaDiff, a diffusion-based generative model for year-long, sub-hourly smart-meter load curves. LoaDiff supports flexible conditioning on static household attributes, such as appliance ownership, and dynamic contextual variables, including calendar information and outdoor temperature. We evaluate the model against multiple generative baselines on three residential electricity-consumption datasets. Our experiments assess four complementary dimensions: fidelity and diversity, training-record memorization risk, downstream utility for load forecasting and appliance detection, and conditional controllability under alternative temperature conditions. The results show that LoaDiff generates realistic and diverse load profiles, achieves a favorable trade-off between generation quality and limited evidence of memorization, preserves information useful for downstream energy applications, and responds coherently to changes in conditioning variables.

0.44

Large Language Models for HVAC Operations in Building Energy Systems: A Critical Review of Methods, Applications, and Deployment Readiness

cs.AI cs.CLeess.SY ·2026-09-04 ·Alexander Neubauer, Tianzhen Hong, Han Li, Mengbo Yu, Amin Darbandi +2 more
survey similarity 0.58
Abstract · 38 pages, 9 figures, 16 tables. Submitted to Energy and Buildings

Building automation systems generate rich sensor data yet remain insight-poor because heterogeneous point naming, missing metadata, and fragmented documentation obstruct their operational use. This systematic review analyses and codes 66 peer-reviewed studies on large language models (LLMs) for HVAC operations published between 2023 and March 2026. Each study is classified across five application families and three LLM method families and assessed for evidence realism, deployment readiness, and the responsibility boundary between the LLM and physical HVAC decisions. The corpus is concentrated in building energy modelling (BEM, 32 of 66 papers), while load forecasting remains too sparse for subfield-level conclusions. Only four studies reach pilot-level evidence, and none reports sustained operational deployment. No study was classified as ready-now for industry adoption; three were near-term and 63 research-only. Nevertheless, several bounded, human-in-the-loop uses merit near-term trials, including point-name normalisation, document-grounded operator support, BEM workflow assistance, and advisory interfaces around physics-based controllers. Conventional machine learning (ML), model predictive control (MPC), reinforcement learning (RL) and ontology-based tools remain more adopted for high-frequency control, short-horizon numerical forecasting, and well-posed ontology mapping, while autonomous agentic operation and unvalidated occupant proxies remain research-stage. Current evidence therefore supports LLMs primarily as semantic and workflow layers rather than autonomous HVAC controllers. Future work should prioritise field-validated benchmarks, orchestration evaluation under operational constraints, and LLM-MPC/RL architectures with bounded latency and verifiable safety properties.

0.64

Exploiting the Benefits of V2B Application on Peak Shaving of Data Center Loads

eess.SY ·2026-08-31 ·Arya Joshi, Hamed Haggi, Chinmay Morankar
similarity 0.58
Abstract · Digest submission version for IEEE IAS Annual Meeting 2026

The accelerated growth in data center projects has introduced a demand-driven bottleneck throughout power grids and contributed to a substantial increase in carbon emissions. These concerns are fueling discussions on methods to use existing energy assets to drive operational efficiency. To this end, this paper explores the benefits of Vehicle-to-Building (V2B) applications to support peak shaving of data center cooling loads. Initially, a literature review was conducted considering V2B constraints and optimization methods including SoC limitations, EV participation, tariffs, and building loads. This analysis was then used to develop a conceptual case study of a 10 MW data center in Loudoun County, VA by simulating a temperature-dependent load profile and adjusting the V2B participation of 40 commercial and passenger EVs. Simulation results indicate that, depending on seasonal variations in cooling load demands, strategic deployment of V2B assets between 12-5pm can offset gross cooling loads by 13-36%.

0.17

Questionnaire-Guided Disaggregation of Energy Appliance Use for Domestic Smart Meter Data

cs.AI ·2026-10-01 ·Achal Nanjundamurthy, Rupam Misra, Suzanne Little, Alan F. Smeaton
similarity 0.58
Abstract

Ireland's smart metering programme records electricity use at 30-minute resolution, with smart meters installed in over 80\% of households as of late 2025. While this is useful for billing of smart, time-of-use tariffs, it is too coarse to capture use of domestic appliances. We present a label-free disaggregation system that breaks usage data into 9 appliance categories by combining event detection for high-power loads with questionnaire-guided estimation. Our evaluation draws on four datasets: a calibration household with a commercial comparator, two public benchmarks (UK-DALE and REFIT) with per-appliance sub-metering, and a smart meter dataset of more than 4,800 years of use from 2,968 Irish consumers. Compared against two independently developed disaggregation systems our hybrid method combining analysis of usage data with questionnaire results, achieves the lowest whole-decomposition error on all buildings across the datasets, with better month-level performance over 54 paired months ($p<0.001$, Holm-corrected). Our method provides useful advice on a household's energy consumption patterns and advice on how to reduce or shift usage on some appliances in order to reduce costs.

0.07

Systematic Evaluation of TabPFN-TS and Chronos-2 for Zero-Shot Heat Load Forecasting in District Heating Networks

cs.LG ·2026-08-20 ·Ben Spoek, Karim K. Ben Hicham, Kai Derzsi, Philipp Althaus, Alexander Mitsos +1 more
publishedbenchmarkhot direction similarity 0.57
Abstract · 43 pages, 10 figures; Supplementary Information included. Revised following peer review, with expanded evaluation and uncertainty analysis

District heating energy hubs require reliable heat load forecasts for efficient operational scheduling. Forecasting models trained on historical data may require retraining as networks evolve. Zero-shot time-series foundation models and in-context forecasting therefore offer a promising alternative: they can adapt at inference time from recent observations rather than by repeated retraining. This study systematically evaluates TabPFN-TS and Chronos-2 for probabilistic heat load forecasting in two German district heating networks and compares them with trained baselines. We assess whether TabPFN-TS, whose underlying model is pretrained entirely on synthetic tabular rather than time-series data, can capture complex district heating dynamics. We analyze covariate choice, context length, temporal resolution, and forecast horizon on selected operating weeks, evaluate the selected configuration over the full year, and assess cross-network transfer. The principal benchmark assumes perfect weather forecasts; a separate sensitivity analysis uses retrospective weather predictions. Hourly 24-hour forecasting with a 12-week rolling context and ambient temperature provides a parsimonious configuration; longer context windows do not improve accuracy. Both TSFMs outperform all trained baselines in deterministic accuracy in the full-year benchmarks. Chronos-2 achieves the best deterministic scores, with TabPFN-TS remaining close: their CVRMSE values on the main data set are 12.48% and 13.07%, respectively. Chronos-2 also achieves lower continuous ranked probability scores in both networks, with TabPFN-TS remaining close. a TSFM-based Multi-Resolution Residual-Correction Forecaster combines an hourly base forecast with short-term high-resolution corrections. Relative to direct high-resolution forecasting, it generally reduces errors in total heat demand over 12-hour periods and recorded prediction times.

0.46

Full-Feature versus Limited-Input Machine Learning for Residential Energy Estimation: A Comparative Analysis of RECS and ResStock Under Realistic Input Constraints

cs.LG ·2026-08-10 ·Aditya Ramnarayan, Fatih Evren, Patti Gunderson, Samuel Rosenberg
code/data similarity 0.57
Abstract

Residential energy estimates are often needed before detailed envelope characteristics, equipment efficiencies, infiltration, sensor, or billing data are available. This study quantifies the trade-off between predictive accuracy and input accessibility using two nationally representative U.S. residential-energy datasets: the survey-based Residential Energy Consumption Survey (RECS) and the simulation-based ResStock dataset. Full-feature models were first used to establish dataset-specific performance benchmarks. For total-energy estimation, the models were subsequently restricted to ten low-burden variables obtainable from occupants, administrative records, or location-based weather data without an on-site energy audit. Among CatBoost, XGBoost, LightGBM, Random Forest, and Neural Networks, CatBoost consistently achieved the highest predictive performance for the full-feature analysis, reaching R2 = 0.90 for ResStock and R2 = 0.73 for RECS. When the feature set was restricted to ten homeowner-accessible inputs to simulate realistic deployment conditions, model performance converged to R2 = 0.61 for RECS and R2 = 0.62 for ResStock, showing that algorithmic complexity cannot fully compensate for missing physical and behavioral information. However, for a more homogeneous ResStock cohort consisting of single-family detached, natural-gas-heated homes in Climate Zone 6A constructed between 2000 and 2010, a reduced-input model improved accuracy to R2 = 0.85, demonstrating the value of targeted modeling for homogeneous populations. The results indicate that tree-based ensemble models can serve as high-fidelity emulators of national-scale residential energy datasets. However, careful consideration of feature availability, dataset origin (empirical vs. synthetic), and applicable use cases are also important.

0.20