CS Paper Radar

WSPolypNet: Weakly Supervised Polyp Localization in Colonoscopy Videos

Giseong Hwang, Minjae Jo, Yeonghyeon Park, Kyeonghun Kim, Seoyeon Han, Donghoon Han, Haneul Kim, Yului Jeong, Insung Hwang, Pa Hong, Ken Ying-Kai Liao, Nam-Joon Kim

cs.CV cs.AI ·submitted 2026-09-08 03:14 UTC · v2

Abstract

Because dense frame-level annotation of colonoscopy videos is costly, we propose WSPolypNet, a weakly supervised framework for polyp localization using only video-level labels. WSPolypNet employs a 3D convolutional neural network trained with video-level supervision to generate class activation maps (CAMs), which identify candidate polyp regions without requiring frame-level spatial annotations. The CAM-derived localization cues are further enhanced using a multi-view strategy and provided to MedSAM2 as point prompts. MedSAM2 then propagates segmentation masks across the video, refining the coarse localization cues according to polyp boundaries. WSPolypNet achieved CorLoc scores of 47.80%, 43.68%, and 35.01% at IoU thresholds of 0.3, 0.5, and 0.7, respectively, compared with 36.87%, 33.72%, and 27.94% in the single-view setting. For small polyps, the multi-view strategy improved CorLoc@0.5 from 16.01% to 30.97%. The framework also achieved a recall of 94.51%. These results demonstrate the potential of weakly supervised spatiotemporal learning to substantially reduce spatial annotation requirements for polyp localization in colonoscopy videos.

Closest papers

Nearest neighbours by meaning across the whole index.

Annotation-Free Representation Learning for Polyp Retrieval in Colonoscopy Videos

cs.CV ·2026-10-29 ·Luca Parolari, Lamberto Ballan, Carlo Biffi, Loic Le Folgoc
code/data similarity 0.71
Abstract · Under submission at ISBI 2027

Colonoscopy is inherently comparative: reliable visual assessment of polyps often depends on complementary views acquired under different viewpoints and imaging conditions. Retrieving such views requires polyp tracklet representations, which recent contrastive methods learn from temporal cues but still build from manually annotated bounding boxes. We propose an annotation-free framework that constructs tracklet views directly from raw colonoscopy videos, enabling temporal self-supervised learning on full-procedure videos, including frames without visible polyps. On REAL-Colon, our method achieves state-of-the-art results on tracklet retrieval and re-identification, outperforming both self-supervised and supervised baselines. We then introduce few-shot polyp retrieval, a task closer to clinical use, where a few observations of a target polyp are used to retrieve its remaining tracklets: with only two examples, our method surpasses most competing methods given ten. Finally, we show that a modest number of unlabeled procedures suffices for competitive performance, making on-site model development more practical. Code is available at https://github.com/lparolari/freerep.

0.28

Attention Residual U-Net for Enhanced Cross-Dataset Polyp Localization in Endoscopy

cs.CV ·2026-11-02 ·Romil Imtiaz, Dimitris K. Iakovidis
similarity 0.65
Abstract

Precise localization of pathologies in endoscopy is a critical task in medical imaging, with deep learning (DL) frameworks now serving as the primary methodology for automated lesion detection. Today, generic object detection methods, such as YOLO, provide state-of-the-art performance in this context. However, their robustness often decreases under real-world clinical conditions due to variations across endoscopic devices, intestinal content, dataset bias, and the presence of small or low-contrast lesions. Motivated by these challenges, we propose a novel polyp detection framework based on a Attention Residual U-Net offering enhanced polyp localization. Instead of directly regressing bounding boxes from global feature representations, the proposed method learns lesion-focused spatial representations and converts them into bounding-box predictions during inference. Unlike conventional encoder-decoder localization frameworks that directly propagate all encoder activations into the decoding pathway, the proposed method selectively suppresses irrelevant background responses before feature reconstruction. This encourages the network to focus on lesion-relevant spatial evidence under heterogeneous imaging conditions. To achieve this, the framework integrates residual feature propagation, attention-guided encoder filtering, and multi-scale contextual learning. The proposed framework was evaluated on multiple public endoscopic datasets acquired using different devices. The comparative experimental results validate its effectiveness over the relevant state-of-the-art methods, with an improvement up to 22.0% in terms of the area under the receiving operating characteristic (AUC).

0.18

Lightweight Frame Compensation for Real-Time Polyp Segmentation under Frame Skipping

cs.CV ·2026-10-22 ·Weihao Gao
similarity 0.64
Abstract · Subsequent analysis revealed a flaw in the evaluation protocol of the proposed lightweight frame compensation. The original experiments did …

Real-time polyp segmentation in computer-assisted colonoscopy is hampered by the difficulty of deploying high-accuracy models under strict latency budgets. Frame skipping, which performs inference every K frames and reuses or interpolates the rest, improves throughput but introduces motion blur and lesion misalignment that degrade temporal consistency. To close this gap, we propose the Lightweight Frame Compensator (LFC), a 77K-parameter plug-and-play module inserted before a frozen segmentation backbone. Operating on a three-frame window, LFC fuses consecutive frames via spatio-temporal attention into a single compensated frame, and is trained only on pseudo-labels generated by a differently seeded model, without any expert annotation. Experiments on three polyp video benchmarks show that LFC recovers most of the accuracy degraded by direct frame skipping and, in several settings, reaches the accuracy of frame-by-frame inference, while retaining a 2.05X--2.55X throughput gain. We further evaluate the temporal stability of three backbones spanning CNN, pyramid Transformer, and global-attention Transformer architectures, revealing a spectrum of sensitivity to frame skipping that arises from how locally or globally each architecture aggregates misaligned input. The compensation gain of LFC follows this spectrum: it is largest for high-capacity Transformer backbones, which achieve the best static accuracy but suffer the most under skip-frame inference. LFC thus offers a lightweight, pluggable, and deployment-friendly route to real-time polyp segmentation.

0.18

TRUE-Colon: Exposing a Consistent Transfer Asymmetry in Real-Time Polyp Detection

eess.IV cs.CVcs.LG ·2026-08-13 ·Sebastian Doerrich, Andreas Franz Schwab, Francesco Di Salvo, Shyam Nandan Rai, Hanh Huyen My Nguyen +1 more
publishedcode/data similarity 0.64
Abstract · Accepted to EndoLINA @ MICCAI 2026 (The International Workshop on Endoluminal Intervention Navigation and Autonomy)

Computer-aided detection (CADe) systems for colonoscopy promise to reduce clinical miss rates, yet reliable real-world deployment remains elusive. This translational gap stems in part from a structural flaw in model development: the reliance on curated datasets that under-represent the long negative stretches and procedure-related artifacts characteristic of routine examinations. Training and evaluating architectures strictly on these lesion-centric benchmarks creates an illusion of success, since such benchmarks cannot capture clinically crucial metrics. To expose this gap, we establish TRUE-Colon, a standardized benchmarking protocol that measures key deployment characteristics alongside localization accuracy, and evaluate four real-time architectures (Faster R-CNN, YOLOv8, YOLOv11, RT-DETR) across curated benchmarks (SUN, PICCOLO) and 60 unedited, full-length procedures (REAL-Colon). We observe a consistent transfer asymmetry: models trained strictly on curated clips suffer a severe performance collapse when evaluated on full procedures, whereas procedure-trained models substantially improve rejection of non-polyp content on REAL-Colon, and largely retain their accuracy on curated benchmarks. Beyond transferability, we find that the Transformer detector attains the strongest sensitivity and the earliest, most persistent detections, while the convolutional detectors stay competitive at a higher throughput. Together, these results indicate that both training and benchmarking for deployable CADe should shift from curated, lesion-centric clips toward full-procedure data and deployment-relevant operating points. Source code is available at https://github.com/sdoerrich97/true-colon.

0.38

CSG-Mamba: A Convolutional Scoring Gating Vision State Space Network for Endoscopic Polyp Segmentation

cs.CV ·2026-08-14 ·Yuliang Wang, Jiaqi Wu, Jiaye Song, Shuxia Ren
published similarity 0.63
Abstract · 14 pages, 6 figures, and 5 tables. Accepted by ICONIP 2026

Accurate polyp segmentation is critical for computer-aided colonoscopy, yet endoscopic images often contain low-contrast boundaries, mucosal texture interference, specular highlights, and device-dependent appearance shifts. Vision State Space Models (SSMs) provide efficient long-range modeling with linear complexity, but existing Vision Mamba segmentation models typically convert 2D features into 1D scanning sequences, which may weaken local geometric continuity and over-smooth irregular contours. We propose CSG-Mamba, a convolutional scoring gating Vision State Space network for endoscopic polyp segmentation. Built on a VM-UNet-style asymmetric U-shaped encoder-decoder, CSG-Mamba inserts a Convolutional Scoring Gating (CSG) module at the semantically rich bottleneck. CSG generates a local spatial score map through pointwise and large-kernel depthwise convolutions and recalibrates state-space features by multiplicative gating. Experiments with three random seeds show that CSG-Mamba achieves 0.9220 Dice and 15.87 HD95 on Kvasir-SEG, and 0.7418 Dice and 0.6570 mIoU on CVC-ColonDB, outperforming the baselines on most overlap and recall metrics while maintaining competitive boundary accuracy.

0.28

Polyp-VSSD: A Pre-trained Transformer with Local-Global Joint VSSD Decoding for Polyp Segmentation

cs.CV ·2026-10-23 ·Xiaobo Zhu, Shiwei Wu, Yu An, Yuechen Tao, He Sun +2 more
similarity 0.62
Abstract

Early detection of colorectal polyps is essential for preventing colorectal cancer, making accurate polyp segmentation a key component in computer-aided diagnosis systems. However, existing endoscopic segmentation methods often exhibit limited representational capacity and insufficient integration of global and local contextual information. To address these limitations, we propose Polyp-VSSD, a novel local-global joint decoding framework built upon a pre-trained Transformer backbone for high-precision polyp segmentation. Polyp-VSSD leverages the strong feature expressiveness of large-scale visual pre-training and unifies global semantic modeling with local fine-grained reconstruction to enhance segmentation fidelity. Extensive experiments on multiple public endoscopic datasets demonstrate that our approach significantly outperforms state-of-the-art methods in both Dice and IoU. On the EndoScene dataset, Polyp-VSSD achieves mIoU and mDice scores of 0.903 and 0.946, respectively, highlighting its robustness and strong generalization capability. This work presents an effective and scalable solution for intelligent endoscopic image analysis.

0.25

SCOPE-4D: Endoscopic 4D Geometry Foundation Models

cs.CV ·2026-10-01 ·Chaoyi Zhou, Zhongpai Gao, Anwesa Choudhuri, Meng Zheng, Benjamin Planche +4 more
code/data similarity 0.61
Abstract · Project page: https://chaoyizh.github.io/SCOPE-4D-page/

Geometric understanding supports endoscopic navigation and robotic assistance, but learning reliable endoscopic geometry faces two challenges: scarce geometric annotations and ambiguity between camera motion and tissue deformation. We present SCOPE-4D, an endoscopic 4D geometry foundation model that jointly predicts camera parameters, dense geometry, and 3D tissue trajectories from monocular RGB video in a single forward pass. Our curation and annotation pipeline constructs SCOPE-5K, a collection of approximately 5,000 clips spanning real and synthetic gastrointestinal endoscopy and laparoscopy. The collection provides rich geometric supervision and includes newly collected phantom and real-colonoscopy evaluation sets. Geometric supervised fine-tuning on SCOPE-5K learns endoscopic priors that improve camera and depth estimation. Common--Residual Motion (CRM) further constrains local deformation relative to common tissue movement. Together with geometric supervision, CRM and trajectory supervision further improve camera and depth estimation over geometric fine-tuning alone while enabling dense 3D tissue tracking. Evaluations on public and newly collected benchmarks demonstrate strong in-domain and out-of-domain geometry, superior 3D tracking, and more stable long-sequence colon reconstruction. A blinded user study further supports the perceived reconstruction quality on real clinical video. Together, these results demonstrate the value of large-scale endoscopic supervision and motion constraints for joint geometry estimation and tissue tracking.

0.21

DynEoMT: Learning Object Dynamicity from Online Segmentation Queries

cs.CV cs.RO ·2026-09-13 ·Calvin Galagain, Martyna Poreba, François Goulette
similarity 0.61
Abstract · Submitted to the IEEE/CVF Winter Conference on Applications of Computer Vision (WACV)

Video segmentation models recognize and track objects over time, but they do not indicate whether each segmented region moves independently of the observing camera. This dynamicity attribute cannot be inferred from semantics alone and is confounded by camera ego-motion. We introduce \method, an online framework that augments query-based video segmentation with region-level dynamicity prediction. It jointly produces the original segmentation outputs and a dynamic or static state for each predicted region. At inference, DynEoMT uses only the current frame and propagated queries, without optical flow, depth, camera pose, previous RGB frames, or feature maps. Because established video segmentation benchmarks do not annotate this attribute, we also introduce a class-agnostic offline supervision pipeline using camera-compensated optical flow and confidence-aware temporal filtering. Across VIPSeg, OVIS, YouTube-VIS 2022, and VSPW, DynEoMT achieves balanced accuracies of 84.3, 68.0, 68.6, and 87.6, respectively, while largely preserving segmentation performance. These results show that segmentation-region dynamicity can be learned from propagated queries, enabling its online prediction without a dedicated motion-processing pipeline at inference. The complete code will be released as open source to enable full reproduction of the method and experiments.

0.25