CS Paper Radar

Freezing of Gait Prediction Under Spatial Occlusion: An IMU-Supervised Cross-Modal Distillation Approach

Chandan Biswas, Aryan Singh, Anabik Pal

cs.CV ·submitted 2026-09-09 07:29 UTC · v1
hot direction

Abstract

Parkinson's disease is a progressive neurodegenerative disorder characterised by gradual deterioration of movement control. Automated freezing-of-gait (FOG) detection supports the objective assessment of gait-related motor impairment. Two common approaches are used for FOG prediction: (i) analysing video recordings of the patient's movements and (ii) analysing data collected using inertial measurement unit (IMU) wearable sensors attached to the patient's lower limbs. Video-based approaches may suffer detection errors during continuous turning-in-place tasks because the lower limbs undergo substantial geometric self-occlusion, degrading pose-estimation accuracy. IMU-based approaches are generally less affected by visual occlusion; however, they are difficult to deploy outside clinical or laboratory settings, as the sensors must be attached securely and remain in place throughout the assessment. Motivated by this, we propose a cross-modal subspace distillation framework to mitigate the limitations of unimodal FOG detection by combining IMU accuracy with video-based practicality. We extract invariant latent topologies from a pre-trained kinematic oracle to structurally supervise a non-encoded visual architecture during training. To resolve periods of severe spatial occlusion, a dual-stream visual model probabilistically fuses skeletal graph nodes and continuous spatial pixels, dynamically shifting reliance to uninterrupted pixel boundaries as joint tracking confidence drops. Evaluated against a public, multi-modal sequence dataset of Parkinson's individuals executing continuous $360^\circ$ turns, empirical results demonstrate that applying sensory boundary topologies strictly mitigates tracking evaluation entropy. Our constrained optimisation confirms that highly precise FOG prediction bounds can be achieved over zero-wearable inference environments.

Comment
9 pages , 2 figures

Closest papers

Nearest neighbours by meaning across the whole index.

Supervised Cross-Modal Feature Alignment for Zero-Wearable Freezing of Gait Detection in Parkinsonism

cs.CV ·2026-09-08 ·Aryan Singh, Chandan Biswas
similarity 0.87
Abstract · 10 pages, 4 figures

Objective assessment of Freezing of Gait (FoG) in Parkinson's disease (PD) relies predominantly on wearable Inertial Measurement Units (IMUs). While IMUs provide optimal kinematic precision, mandatory sensor attachment restricts continuous clinical deployment. Conversely, unobtrusive vision-based alternatives suffer substantial classification errors during turning-in-place tasks, where geometric self-occlusion degrades deterministic skeletal coordinates and obscures the high-frequency precursors required for FoG detection. To resolve these physical observation limits, we propose a supervised cross-modal subspace distillation framework. During optimisation, pre-trained kinematic data from IMU sensors and contextual clinical metadata act as oracles to guide a deployable visual architecture. By incorporating joint velocity and acceleration derivatives, utilising a confidence-based gating mechanism, the visual model mitigates some of the tracking errors during occlusion events. Empirical evaluations confirm this latent alignment transfers the predictive fidelity of hardware sensors directly into the visual representation, yielding $85.5\%$ accuracy, and $82.4\%$ balanced accuracy. All the while maintaining a vision only model at inference.

0.25

Towards Context-Aware Clinical Motion Understanding in Daily Living at Home: Freezing of Gait Detection with Egocentric Vision

cs.AI ·2026-08-13 ·Vayalet Stefanova, Diwas Lamsal, Margot Genbrugge, Maxim Yudayev, Christian Schlenstedt +3 more
published similarity 0.78
Abstract · Accepted to ECCV Workshop 2026 (Human Motion Challenges in Real-World and Clinical Settings)

Understanding motion in daily living requires context beyond kinematics, because similar inertial patterns during activities of daily living (ADLs) can reflect intentional stopping, object interaction, or pathological movement impairment. Egocentric vision provides task-related context that may help disambiguate these cases. We investigate this challenge through freezing of gait (FOG) detection in Parkinson's disease (PD), a symptom strongly influenced by contextual factors during ADLs. Using synchronized egocentric video, wearable IMUs, and expert-annotated FOG labels collected from 13 PD participants in their homes, we evaluate frozen representations from pretrained ego-video and time-series foundation models, alongside an IMU-based TCN trained from scratch, under leave-one-subject-out evaluation. The IMU-based TCN achieved the strongest event-detection performance, reaching 42.3 F1 and 83.0 AUROC, compared with 32.6 F1 and 77.2 AUROC for V-JEPA2 ego-video features. Although ego-video alone did not outperform IMU-based sensing, it showed above-chance discrimination, and qualitative analyses suggest that egocentric vision may capture FOG-relevant information independent of IMUs. Together, these results support the use of pretrained ego-video representations to add contextual information to wearable-sensor-based clinical motion understanding in daily living.

0.20

GaitFM: A Cross-Modal Foundation Model for Wearable Gait Assessment

cs.CV ·2026-11-01 ·Yize Cai, Zhiqing Hong
similarity 0.67
Abstract · 18 pages, 4 figures

Gait assessment supports the diagnosis, monitoring, and prognosis of diverse movement-related conditions, such as neurological and musculoskeletal disorders. Recent advances in deep learning using everyday wearable inertial measurement units (IMUs) offer an accessible and low-cost approach to automated gait assessment. However, IMU measurements vary substantially across individuals, body locations, and device configurations, while existing deep learning models are typically developed using small, homogeneous datasets for specific clinical tasks, limiting their robustness and generalizability in diverse real-world contexts. Here we present GaitFM, a cross-modal foundation model for gait assessment using IMU sensors. GaitFM improves the generalizability of gait assessment by transferring knowledge from large vision models and pretraining on unlabeled IMU sensor data. We pretrain GaitFM on a large curated dataset comprising about 4,000 participants and 1.23 million gait windows across diverse clinical and daily conditions, sensor modalities, and body locations. GaitFM demonstrates strong performance across 18 gait-related tasks, including 3 gait parameter estimation tasks, 14 disease and gait abnormality detection tasks, and 1 clinical outcome prediction task. Furthermore, GaitFM generalizes across different sensor configurations and body locations, including those commonly used in clinical settings and everyday wearable devices. These findings demonstrate the effectiveness of transferring visual knowledge in improving sensor-based gait assessment performance, offering a new promising pathway for addressing data scarcity in the sensor and medical domains.

0.13

Where Does EEG Help Wearable Freezing of Gait Detection?

cs.LG ·2026-10-31 ·Chuntian Chi, Lifang He, Huajie Shao, Gang Zhou
similarity 0.63
Abstract

Freezing of gait (FoG) detectors built on inertial measurement units (IMUs) are accurate while the legs move, but they become unreliable when the legs are nearly still, which is exactly when akinetic freezing, voluntary stopping, and standing must be told apart. Electroencephalography (EEG) captures motor-planning activity that leg sensors cannot, but EEG is impractical for daily use. We ask where EEG helps: as an input at inference time, or only during pretraining, so that the deployed detector still needs only IMUs. We assemble a pretraining corpus of synchronized EEG and IMU recordings (5 datasets, 184 people, 94 hours) and compare six settings that differ only in the modalities used for pretraining and as model input, each with tuned hyperparameters and five independent pretraining runs. On the BXHC FoG dataset (leave-one-patient-out, 10 patients with FoG), adding EEG as input raises FoG F1 from 0.663 to 0.740 (9 of 10 patients improve), and the gain in ranking performance is confined to the quartile of windows with the least leg movement (AUROC +0.063). Pretraining the IMU encoder jointly with EEG improves an IMU-only detector both within the cohort (FoG F1 0.663 to 0.705) and when it is trained on a small cohort and tested on another (FoG F1 +0.083, all 10 test patients improve). Repeating the study with PD-only and healthy-only pretraining corpora, each with its own hyperparameter search, shows that IMU-based detection is robust to the corpus, whereas the benefit of aligning EEG with IMU requires both. Cross-cohort analysis further shows that detectors trained without annotated voluntary stops classify nearly all stops as freezing. Finally, on PD versus non-PD classification in three external datasets, joint EEG+IMU pretraining improves PD detection from walking EEG over EEG-only pretraining (AUROC 0.750 vs. 0.683), while IMU-based detection does not depend on the pretraining.

0.24

WaveFoG: Wavelet Gated Transformer for Parkinson's Freezing of Gait Detection Using Wearable Accelerometer Signals

eess.SP ·2026-08-26 ·Md Shihabul Islam Shovo, Nishi Kanta Paul, Adrita Rahman, Israt Jerin Esha
code/data similarity 0.62
Abstract

Freezing of gait (FoG) is one of the most debilitating episodic motor symptoms of Parkinson's disease (PD). FoG detection from wrist worn inertial signals poses challenging problems such as extreme data class imbalance (only 12-18% of signal windows are FoG), low frequency postural instabilities alongside diagnostically crucial 3-8 Hz rhythmic tremors, and the need for subject independent generalisation. To address these, this paper presents WaveFoG, a novel wavelet gated Transformer architecture that combines multi scale representations from discrete wavelet transform (DWT) with a dual branch encoder. A 1D CNN captures local gait texture, and a Transformer captures global temporal context. They are fused via a sigmoid gating fusion layer that modulates the encoder output based on the DWT sub-band descriptors. Trained with focal loss and evaluated on the public Kaggle TLVMC FoG Prediction dataset under subject independent grouped ten fold cross validation (SI-CV), WaveFoG achieves a mean F1-score of 0.875 +/- 0.017 and AUPRC of 0.833 +/- 0.020, exceeding single branch baselines (1D CNN, Bi-LSTM, and vanilla Transformer) by up to 5.4 pp on F1. Temporal saliency maps highlight temporal patterns that are consistent with reported characteristics of FoG onset. The source code of this project is available at: https://github.com/Shihabul-Shuvo/WaveFoG

0.33

Impact of Patient Orientation in Single- and Multi-View Camera Environments for AI-based Rehabilitation Monitoring

cs.CV ·2026-09-28 ·Miriama Jánošová, Andreas Lang, Petra Budikova, Jan Sedmidubsky
dataset similarity 0.61
Abstract

Automated quality assessment of rehabilitation exercises relies heavily on accurate human pose estimation from video data. Although numerous RGB-based pose estimation methods have been proposed, the impact of camera placement on detecting clinically relevant movement errors remains insufficiently explored. To address this gap, we introduce REHAB26-ViewAngles, a dataset comprising correct and incorrect rehabilitation exercise executions captured from a wide range of camera angles. Furthermore, we propose a novel separability metric to quantify an algorithm's ability to distinguish between valid and faulty exercise repetitions. Using these tools, we analyze how various RGB-based pose-estimation strategies are suitable for exercise quality assessment under varying camera placements. In particular, we analyze single-camera 2D and 3D pose estimation and four multi-camera strategies: a combination of two orthogonal 2D views, 3D triangulation, weighted 3D fusion, and an AI-based pose-estimation transformer model specifically trained from two synchronized cameras. Our findings reveal that an optimally placed 2D camera can improve the separability by 16.9% over the commonly used 0° frontal view and frequently outperforms single-camera 3D estimation, while combining two views can further improve accuracy by up to 13.1%. These results offer practical guidance for deploying rehabilitation monitoring in both home and clinical settings.

0.09

MMGait: Benchmarking and Unifying Gait Recognition across Heterogeneous Modalities

cs.CV ·2026-09-10 ·Saihui Hou, Chenye Wang, Qingyuan Cai, Aoqi Li, Yongzhen Huang
benchmark similarity 0.61
Abstract · 21 pages, 6 figures

Gait recognition is commonly studied using RGB videos or their derived silhouettes and poses. Yet human walking produces heterogeneous photometric, geometric, and motion cues that cannot be systematically examined with RGB-centered benchmarks. We present MMGait, a large-scale multi-sensor benchmark that brings visible, infrared, depth, LiDAR, and radar observations into sequence-level correspondence. It provides diverse modalities spanning appearance, contours, geometry, motion, and body structure. Under a shared impostor-augmented protocol, we evaluate single-modal recognition, cross-modal recognition via directed retrieval, and multi-modal recognition using task-specific experts. Across settings, modality rankings vary with probe conditions, cross-modal alignment remains difficult, and fusion often provides complementary gains. This analysis exposes a scalability problem: individual modalities, modality pairs, and fusion configurations are typically handled by separately trained experts. We formulate Omni-Modal Gait Recognition, which unifies single-modal, cross-modal, and multi-modal recognition within a shared identity space. OmniGait++ uses modality-specific front ends followed by a shared identity encoder to preserve modality-dependent cues while learning comparable identity descriptors. An anchor-guided fusion module aggregates modality subsets of varying size without frame-level synchronization. A jointly trained checkpoint covers all three recognition settings and accommodates modality subsets of different compositions and cardinalities. Experiments show OmniGait++ remains competitive with task-specific experts in many shared settings and extends to higher-cardinality fusion unavailable to fixed-pair models. The results establish MMGait as a common testbed for heterogeneous gait sensing and demonstrate the feasibility of unified recognition under varying modality availability.

0.30

GaitVista: Reliability-Aware AI Measurement toward Accessible Longitudinal Gait Assessment

cs.AI ·2026-09-18 ·Nethmi Jayasinghe, Mihir Parashar, Amit Ranjan Trivedi
similarity 0.60
Abstract

Tracking recovery of walking function requires detecting meaningful gait change across rehabilitation sessions, yet objective 3D measurement remains confined to specialized motion-capture laboratories. Small camera sets and body-worn inertial sensors broaden access, but reliability varies across joints and time, allowing sensing failures to masquerade as patient change. We present \textsc{GaitVista}, a reliability-aware measurement layer whose lightweight gate assigns joint- and frame-specific visual contributions using camera coverage, local visual quality, cross-modal disagreement, and root-motion continuity, and exposes them for inspection. Across seven clean and degraded sensing conditions on TotalCapture, \textsc{GaitVista} reduces average full-body and lower-body error by \textbf{27.7\%} and \textbf{27.8\%}, attains the lowest worst-condition error among fusion methods, and reduces the gap to a joint-frame oracle from $2.76$--$5.33$~cm for condition-blind baselines to $1.11$~cm. On MoVi with image-derived keypoints, it is the only deployable fusion method to improve over both unimodal streams, reducing marker-supported error by \textbf{6.4\%} relative to the strongest learned fusion baseline. On TotalCapture, it improves bilateral knee-flexion waveform accuracy by \textbf{18.9\%}. Raw inertial measurements from five TotalCapture participants show location- and time-varying magnetic disturbance, supporting the design's reliability premise. Both benchmarks contain neurologically healthy participants in controlled settings and retain participant-specific IMU calibration; we therefore report progress toward accessible gait assessment, not validated clinical deployment.

0.23