CS Paper Radar

Where Does EEG Help Wearable Freezing of Gait Detection?

Chuntian Chi, Lifang He, Huajie Shao, Gang Zhou

cs.LG ·submitted 2026-10-31 00:37 UTC · v1

Abstract

Freezing of gait (FoG) detectors built on inertial measurement units (IMUs) are accurate while the legs move, but they become unreliable when the legs are nearly still, which is exactly when akinetic freezing, voluntary stopping, and standing must be told apart. Electroencephalography (EEG) captures motor-planning activity that leg sensors cannot, but EEG is impractical for daily use. We ask where EEG helps: as an input at inference time, or only during pretraining, so that the deployed detector still needs only IMUs. We assemble a pretraining corpus of synchronized EEG and IMU recordings (5 datasets, 184 people, 94 hours) and compare six settings that differ only in the modalities used for pretraining and as model input, each with tuned hyperparameters and five independent pretraining runs. On the BXHC FoG dataset (leave-one-patient-out, 10 patients with FoG), adding EEG as input raises FoG F1 from 0.663 to 0.740 (9 of 10 patients improve), and the gain in ranking performance is confined to the quartile of windows with the least leg movement (AUROC +0.063). Pretraining the IMU encoder jointly with EEG improves an IMU-only detector both within the cohort (FoG F1 0.663 to 0.705) and when it is trained on a small cohort and tested on another (FoG F1 +0.083, all 10 test patients improve). Repeating the study with PD-only and healthy-only pretraining corpora, each with its own hyperparameter search, shows that IMU-based detection is robust to the corpus, whereas the benefit of aligning EEG with IMU requires both. Cross-cohort analysis further shows that detectors trained without annotated voluntary stops classify nearly all stops as freezing. Finally, on PD versus non-PD classification in three external datasets, joint EEG+IMU pretraining improves PD detection from walking EEG over EEG-only pretraining (AUROC 0.750 vs. 0.683), while IMU-based detection does not depend on the pretraining.

Closest papers

Nearest neighbours by meaning across the whole index.

Freezing of Gait Prediction Under Spatial Occlusion: An IMU-Supervised Cross-Modal Distillation Approach

cs.CV ·2026-09-09 ·Chandan Biswas, Aryan Singh, Anabik Pal
hot direction similarity 0.63
Abstract · 9 pages , 2 figures

Parkinson's disease is a progressive neurodegenerative disorder characterised by gradual deterioration of movement control. Automated freezing-of-gait (FOG) detection supports the objective assessment of gait-related motor impairment. Two common approaches are used for FOG prediction: (i) analysing video recordings of the patient's movements and (ii) analysing data collected using inertial measurement unit (IMU) wearable sensors attached to the patient's lower limbs. Video-based approaches may suffer detection errors during continuous turning-in-place tasks because the lower limbs undergo substantial geometric self-occlusion, degrading pose-estimation accuracy. IMU-based approaches are generally less affected by visual occlusion; however, they are difficult to deploy outside clinical or laboratory settings, as the sensors must be attached securely and remain in place throughout the assessment. Motivated by this, we propose a cross-modal subspace distillation framework to mitigate the limitations of unimodal FOG detection by combining IMU accuracy with video-based practicality. We extract invariant latent topologies from a pre-trained kinematic oracle to structurally supervise a non-encoded visual architecture during training. To resolve periods of severe spatial occlusion, a dual-stream visual model probabilistically fuses skeletal graph nodes and continuous spatial pixels, dynamically shifting reliance to uninterrupted pixel boundaries as joint tracking confidence drops. Evaluated against a public, multi-modal sequence dataset of Parkinson's individuals executing continuous $360^\circ$ turns, empirical results demonstrate that applying sensory boundary topologies strictly mitigates tracking evaluation entropy. Our constrained optimisation confirms that highly precise FOG prediction bounds can be achieved over zero-wearable inference environments.

0.25

Towards Context-Aware Clinical Motion Understanding in Daily Living at Home: Freezing of Gait Detection with Egocentric Vision

cs.AI ·2026-08-13 ·Vayalet Stefanova, Diwas Lamsal, Margot Genbrugge, Maxim Yudayev, Christian Schlenstedt +3 more
published similarity 0.59
Abstract · Accepted to ECCV Workshop 2026 (Human Motion Challenges in Real-World and Clinical Settings)

Understanding motion in daily living requires context beyond kinematics, because similar inertial patterns during activities of daily living (ADLs) can reflect intentional stopping, object interaction, or pathological movement impairment. Egocentric vision provides task-related context that may help disambiguate these cases. We investigate this challenge through freezing of gait (FOG) detection in Parkinson's disease (PD), a symptom strongly influenced by contextual factors during ADLs. Using synchronized egocentric video, wearable IMUs, and expert-annotated FOG labels collected from 13 PD participants in their homes, we evaluate frozen representations from pretrained ego-video and time-series foundation models, alongside an IMU-based TCN trained from scratch, under leave-one-subject-out evaluation. The IMU-based TCN achieved the strongest event-detection performance, reaching 42.3 F1 and 83.0 AUROC, compared with 32.6 F1 and 77.2 AUROC for V-JEPA2 ego-video features. Although ego-video alone did not outperform IMU-based sensing, it showed above-chance discrimination, and qualitative analyses suggest that egocentric vision may capture FOG-relevant information independent of IMUs. Together, these results support the use of pretrained ego-video representations to add contextual information to wearable-sensor-based clinical motion understanding in daily living.

0.20

Supervised Cross-Modal Feature Alignment for Zero-Wearable Freezing of Gait Detection in Parkinsonism

cs.CV ·2026-09-08 ·Aryan Singh, Chandan Biswas
similarity 0.58
Abstract · 10 pages, 4 figures

Objective assessment of Freezing of Gait (FoG) in Parkinson's disease (PD) relies predominantly on wearable Inertial Measurement Units (IMUs). While IMUs provide optimal kinematic precision, mandatory sensor attachment restricts continuous clinical deployment. Conversely, unobtrusive vision-based alternatives suffer substantial classification errors during turning-in-place tasks, where geometric self-occlusion degrades deterministic skeletal coordinates and obscures the high-frequency precursors required for FoG detection. To resolve these physical observation limits, we propose a supervised cross-modal subspace distillation framework. During optimisation, pre-trained kinematic data from IMU sensors and contextual clinical metadata act as oracles to guide a deployable visual architecture. By incorporating joint velocity and acceleration derivatives, utilising a confidence-based gating mechanism, the visual model mitigates some of the tracking errors during occlusion events. Empirical evaluations confirm this latent alignment transfers the predictive fidelity of hardware sensors directly into the visual representation, yielding $85.5\%$ accuracy, and $82.4\%$ balanced accuracy. All the while maintaining a vision only model at inference.

0.25

Your Vision Foundation Model Is Secretly an EEG Foundation Model

cs.AI ·2026-11-12 ·Guoan Wang, Feng Liu
similarity 0.57
Abstract

Electroencephalography (EEG) foundation models are pretrained on thousands of hours of recordings, yet their frozen features transfer poorly to downstream tasks, and this transfer does not consistently improve with larger models or more pretraining data. We show that a vision foundation model that has never seen EEG is a stronger frozen EEG encoder than these specialized models, once the signals are rendered as images that a vision transformer can read. Our method, SeeEEG, keeps the vision backbone frozen and learns only how EEG is displayed to it. Each channel occupies a dedicated row of patches and is drawn either as a waveform at a fixed gain or as a scalogram whose frequency range spans the patch height, so that task-relevant patterns fall within individual tokens. The montage, filtering, and contrast parameters of this display are initialized from a standard clinical montage and optimized with the task loss through the frozen backbone, which amounts to at most 1,113 trainable parameters per view. We compare SeeEEG with seven EEG foundation models on eight clinical, sleep, affective, and brain-computer interface datasets, with every encoder frozen and paired with identical readout heads. With a frozen DINOv3 ViT-B, SeeEEG outperforms every EEG foundation model in balanced accuracy on all eight datasets and reaches a mean rank of 1.3 in Cohen kappa or AUROC, compared with 2.9 for the strongest baseline, REVE. The learned displays transfer without further optimization to the video encoder V-JEPA 2.1, which outperforms every EEG foundation model on both metrics on six of the eight datasets. Replacing DINOv3 with a randomly initialized ViT-B lowers the score by 15.2 points on average, so the ability to read rendered EEG comes from visual pretraining.

0.20

BRIDGE-EEG: Bridging Self-Supervised Pretraining and Efficient Deployment for Cross-Dataset EEG Classification

cs.HC cs.LGeess.SP ·2026-09-10 ·Meghna Roy Chowdhury, Chengwei Zhou, Haotian Yu, Gourav Datta, Shreyas Sen
similarity 0.56
Abstract · 11 pages, 7 figures 8 tables, journal submission

The growing use of electroencephalography (EEG) motivates automated analysis that is accurate, transferable, and deployable on constrained hardware. Recent EEG foundation models learn general representations from large-scale pretraining, but their size and computational cost limit edge and wearable deployment. We introduce BRIDGE-EEG, an efficient multi-task EEG classification pipeline that preserves the benefits of pretraining while reducing model size. A unified preprocessing scheme maps heterogeneous recordings with different channel counts, montages, and sampling rates to a device-agnostic 62-channel time--frequency representation. We pretrain an SE-ResNet18 teacher (11.84 M parameters) with SimCLR on unlabeled EEG from five heterogeneous datasets, then compress it into SE-ResNet8 (1.56 M) and SE-ResNet4 (0.48 M) students using task-agnostic and task-specific distillation. We evaluate six benchmarks spanning abnormality detection, motor imagery, and emotion recognition. For abnormality detection and emotion recognition, the students achieve accuracy comparable to or better than several recent EEG foundation models with 10--1,000$\times$ more parameters. Motor imagery shows a remaining representation gap, highlighting the importance of pretraining diversity. Inference profiling on a server GPU, desktop CPU, and NVIDIA Jetson Orin Nano shows up to 3.0$\times$ lower edge energy per inference (15.64 mJ vs. 46.67 mJ). The compact models further support future deployment on MCU-class wearables.

0.43

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

cs.CE cs.LG ·2026-08-31 ·Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
benchmark similarity 0.56
Abstract

Motor imagery (MI) electroencephalography (EEG) decoding could support post-stroke rehabilitation, but models developed on healthy cohorts may not transfer reliably to pathological EEG. We evaluated whether Low-Rank Adaptation (LoRA) can efficiently adapt three pretrained EEG foundation models (i.e., LaBraM-base, REVE-base, and REVE-large) for binary left- versus right-hand MI decoding. Frozen-backbone head-only baselines and LoRA adaptation were evaluated using subject-wise five-fold cross-validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 dataset comprising 30 stroke participants. On EEGMMIDB, LoRA increased accuracy to 0.822 for LaBraM-base and 0.957 for REVE-base. On UET175, all head-only models performed near chance. With LoRA, LaBraM-base remained near chance (0.499$\pm$0.009), whereas REVE-base reached 0.847$\pm$0.194 and outperformed REVE-large (0.806$\pm$0.178), indicating that increased model capacity alone did not improve stroke-domain adaptation. The strongest stroke configuration, REVE-base LoRA, was further evaluated using within-cohort leave-one-subject-out cross-validation (LOOCV), showing 0.952 mean accuracy, but subject-wise accuracy ranged from 0.586 to 1.000, revealing a small low-performing tail. Zero-shot transfer from EEGMMIDB to UET175 remained near chance (0.464$\pm$0.072). These findings show that healthy-benchmark performance does not ensure transfer to stroke EEG. Translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiological discriminability.

0.28

Lightweight Semantic EEG Foundation Model for Frozen Cross-Disorder Transfer

cs.LG eess.SPq-bio.NC ·2026-10-04 ·Rita Huan-Ting Peng, Nhat Bui
similarity 0.56
Abstract

Large-scale EEG foundation models have demonstrated promising transferability across neurological disorders, but often require millions of parameters and substantial computational resources. In this paper, we present the Universal Semantic EEG Foundation Model (USE-FM), a lightweight EEG foundation model that learns transferable neural representations through self-supervised signal reconstruction on the Temple University Hospital EEG Corpus (TUEG). After pretraining, the encoder is frozen and evaluated on two clinically distinct downstream tasks, abnormal EEG detection (TUAB) and epileptic seizure recognition (TUEP), using a unified frozen-transfer protocol against recent EEG foundation models, including LUNA-Base and CBraMod. With only 1.46 million parameters, approximately one-fifth the size of existing models, USE-FM achieves competitive overall performance, including strong sensitivity and F1-score on TUEP (SEN $75.00 \pm 14.14$, F1 $70.37 \pm 4.01$), while maintaining competitive performance on TUAB (AUC $85.24 \pm 5.61$). Beyond downstream classification, latent representation analysis using $k$-means clustering together with PCA and t-SNE demonstrates that USE-FM learns organized semantic EEG representations comparable to substantially larger foundation models. These results suggest that large-scale self-supervised pretraining enables lightweight architectures to learn transferable semantic EEG representations, providing a computationally efficient foundation for cross-disorder analysis and future clinical decision support in neurological disorders.

0.06

BrainCodes: A Lightweight EEG Foundation Model over Discrete Neural Codes

cs.LG cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
position similarity 0.56
Abstract · Preprint. Under review

Recent electroencephalography (EEG) foundation models increasingly emphasize model scale, potentially limiting their deployment on resource-constrained devices and in everyday environments. We argue that transferable EEG features can instead be learned with a compact architecture and introduce BrainCodes, a lightweight foundation model pretrained through self-supervised learning on more than 800 hours of recordings from over 1,000 participants. Our architecture combines a quantization-based neural tokenizer with a spatiotemporal encoder that supports arbitrary electrode configurations. The pretraining objective explicitly encourages representations that capture spatial connectivity through channel positional encoding, and sensitivity to narrowband neural oscillations through an auxiliary training objective. Our model matches or surpasses the state of the art across diverse neurophysiological monitoring tasks, including sleep staging, attention assessment, and cognitive load estimation. BrainCodes transfers effectively to low-resource wearable devices while using up to 97% fewer trainable parameters than comparable architectures. Beyond predictive accuracy, our evaluation framework characterizes the geometry and invariances of learned EEG representations across measurable spatial, temporal, and spectral signal properties.

0.21