CS Paper Radar

From Few-Shot Segmentation to Clinician-in-the-Loop Medical Image Analysis

Yazhou Zhu

cs.CV ·submitted 2026-09-09 10:26 UTC · v2

Abstract

Few-shot medical image segmentation (FSMIS) seeks to delineate unseen structures from a small support set, but its standard formulation fixes task-defining evidence before inference. This assumption is fragile under acquisition shift, atypical pathology, ambiguous boundaries, and poor image quality. Adding clinician interaction and rapid adaptation is not sufficient: the binding constraint is deciding when asking or changing is warranted. We therefore reframe FSMIS as a three-layer sequential decision problem. First, decidable self-assessment separates errors that a bounded intervention can repair from those that no admissible intervention can reach. We formalize this distinction through a correctable set defined by the update operator and remaining interaction budget. Second, selective interaction allocates a distinct expert-attention budget by response-conditioned net expected value of information, yielding explicit accept, query, and defer actions. Third, bounded adaptation emphasizes reversibility and independent safety reassessment rather than speed. A complementary cross-case memory stores reproducible correction priors over failure modes instead of disease-specific mask priors. This structure links sparse support representation, cross-domain robustness, multi-level risk estimation, clinician feedback, and governed experience transfer. We state six hypotheses with an explicit dependency order and propose a minimal pilot that can falsify the foundational self-assessment claim before a clinician study. The central claim is not that interaction resolves domain shift, but that scarce expert attention should be used only when a bounded intervention is expected to reach a clinically better outcome.

Comment
25 pages, 3 figures, 5 tables. Perspective article

Closest papers

Nearest neighbours by meaning across the whole index.

CVP-BAA: Efficiently Adapting Segment Anything Model for Medical Image Segmentation

eess.IV ·2026-10-22 ·Mei Wang, Minghui Li, Libin Lan
code/data similarity 0.64
Abstract · Submitted to CVIU, 35 pages, 8 tables, 8 figures. Our code is available at \href{https://github.com/WangMei-wm/CVP-BAA}{here}

Various task-specific medical segmentation models have demonstrated strong performance, their heavy reliance on extensive annotations and highly specialized architectures limits their versatility, scalability, and clinical applicability. Recently, adapting vision foundation models, particularly the segment anything model (SAM), has emerged as a promising alternative. However, prevalent parameter-efficient fine-tuning (PEFT) strategies, such as prompt tuning and adapter tuning, often lack an explicit mechanism to embed local structural priors into the long-range dependency modeling of vision transformers (ViT), rendering them insufficiently sensitive to fine-grained details. To address these limitations, we introduce CVP-BAA, a novel hybrid PEFT method that improves SAM's sensitivity to domain-specific textures and local details, leading to superior boundary delineation. The proposed CVP-BAA adopts two key ideas. First, it introduces a convolutional visual prompting (CVP) strategy that leverages convolutional features as structural priors, prepending them to the key and value projections within the multi-head self-attention layers of strategically selected ViT blocks. Through a dedicated prompt generation-and-injection module, this mechanism effectively bridges local spatial details with global context semantics. Second, a boundary-aware adapter (BAA) is designed as a parallel branch to the feed-forward network within the same selected blocks. By explicitly computing and amplifying high-frequency components, the BAA enhances feature representations along tissue boundaries and fine-grained lesion structures. Extensive experiments on five benchmarks across three imaging modalities demonstrate that CVP-BAA achieves superior segmentation performance, surpassing existing task-specific models and PEFT-based SAM adaptations in both quantitative metrics and qualitative results.

0.38

Aligning Medical Vision Language Models at the Capability Boundary with Entropy Adaptive Rubric Grounding

cs.CV cs.AI ·2026-10-29 ·Hongyu Bai, Jiaqi Zeng, Chunzheng Zhu
published similarity 0.64
Abstract · Accepted at ACM Multimedia Asia 2026 (MMAsia 2026). 10 pages, 4 figures

Medical diagnostic reasoning requires verifiable links between visual evidence and clinical knowledge, yet current medical vision language models are aligned with objectives that reward the wrong behavior. Uniform supervised fine tuning lets easy cases dominate updates while clinically critical boundary cases saturate prematurely. Sparse rewards based only on final-answer correctness cannot assess anatomical grounding or clinical logic, inviting reward hacking through answer shortcuts. We propose MedCBR, a two-stage alignment framework coupling boundary-aware preference optimization with rubric-grounded reinforcement learning. First, we construct counterfactual boundary preferences at the model's capability frontier using empirical pass rates and preference pairs that share reasoning prefixes but diverge at decisive diagnostic branches. Difficulty Weighted Boundary Preference Optimization (DBPO) concentrates learning on this calibrated boundary region. Second, we distill reusable clinical rubrics from boundary trajectories and activate them according to prediction entropy. Entropy Gated Grounded Policy Optimization (EGPO) rewards answer correctness, anatomical grounding, and reasoning fidelity while suppressing rubric noise on reliable samples. A reference policy anchored to the boundary-aligned model couples population-level boundary priors with instance-level uncertainty, making diagnostic reasoning more accurate and clinically grounded. Experiments on six medical benchmarks show consistent improvements over strong general, specialized, and reinforcement learning baselines, reaching 61.2% average accuracy with the largest gains on challenging differential diagnosis tasks. Ablations show super-additive gains: combining the two stages exceeds the sum of their individual improvements.

0.23

A Decision-Aware Evaluation Protocol for Uncertainty in Medical Image Segmentation

cs.CV ·2026-10-15 ·Saket Maganti, Shreyank N Gowda
similarity 0.63
Abstract

Medical segmentation uncertainty is often evaluated with calibration error or pixel-level error-detection scores, but these metrics do not show whether uncertainty improves downstream review decisions. We propose a decision-aware evaluation protocol that separates uncertainty estimation from deferral policy and evaluates their combination under fixed review budgets: which pixels, regions, or images should be accepted, and which should be reviewed. The protocol reports fixed-budget error reduction, risk-coverage behaviour, region-level review proxies, structural failure modes, probability-derived baselines, and sensitivity to review assumptions. We instantiate it across retinal vessel, skin lesion, and polyp segmentation with multiple backbones and uncertainty estimators. Under matched inference budgets and canonical multi-layer MC Dropout, test-time augmentation (TTA) gives a stronger error-detection signal across matched MC--TTA comparisons, including architecture and dropout-placement checks. However, estimator rankings are not universal. For example, probability-derived scores remain competitive, deep ensembles can outperform TTA, learned deferral helps mainly when the base estimator is weak, and rankings can change with review unit, uncertainty target, correction assumptions, and cost model. Structural and second-observer analyses further show that boundary and thin-structure failures are partly tied to annotation ambiguity. These findings support evaluating uncertainty as an estimator-policy-review configuration, not as a standalone score map. Code: https://anonymous.4open.science/r/Uncertainity-in-Medical-Image-Segmentation/README.md

0.34

Retrieval-Augmented Correction for Generalist Medical Image Segmentation

cs.CV cs.AI ·2026-11-17 ·Vincenzo Marcianò, Xiaoming Zhang, Michela Antonelli, Sebastien Ourselin, Maria A Zuluaga
top venuecode/data similarity 0.63
Abstract · Accepted in Transactions on Machine Learning Research (10/2026). Reviewed on OpenReview: https://openreview.net/forum?id=PeDqE0SQRe

Automated segmentation is routinely used as the first step in quantitative image-based clinical workflows, where predicted masks are subsequently reviewed and corrected by human operators. Automated correction of the residual structural errors is currently addressed one anatomy at a time, so the number of trained correctors scales with the number of segmentation targets. We present GRACE, a retrieval-augmented refiner that edits an input mask under context drawn from a shared knowledge base of verified prior cases. The refiner is trained once on a multi-organ corpus spanning compact organs, cavities, branching vessels, and tumour lesions. In the held-out dataset-transfer evaluation, three held-out datasets query a fixed knowledge base built from training data only. A separate leave-one-anatomy-out experiment tests parameter-free index extension: verified cases of an unseen solid organ enter the knowledge base, and the refiner stays frozen. A light shape-aware projection head on a frozen multimodal encoder maps embedding similarity to the shape agreement of the masks, so the knowledge base returns cases that the refiner can use as a shape prior. We evaluate GRACE on 18 public datasets spanning CT, MRI and ultrasound, using nine refinement configurations and seven upstream segmentors that span weak, mid, and strong operating regimes. We report each change with the DSC of its input mask. On the weak tier, the input DSC is 0.386 and GRACE adds up to +0.35 DSC. On a strong segmentor, the input DSC is 0.932 and the mean change is small. Transfer to an imaging modality that is absent from training and from the index is partial and depends on the anatomy, and remains an open research direction. Our results suggest retrieval-conditioned refinement is a practical alternative to anatomy-specific correction models. Code: https://github.com/robustml-eurecom/grace

0.55

ViCoR: Estimating Visual Necessity via Counterfactual Residuals for Multimodal Medical Data Selection

cs.LG cs.AI ·2026-10-18 ·Haotian Gan, Yudong Li, Xintian Li, Jiarui Han, Weidong Tang
top venuebenchmarkcode/data similarity 0.63
Abstract · Accepted to NeurIPS2026

Medical vision-language models often exhibit hidden stratification, where high overall performance masks failures on subtle visual findings and overlapping clinical conditions. We trace this failure mode to modality imbalance during fine-tuning, where strong linguistic priors can suppress visually grounded learning and induce plausible but weakly grounded rationales. Existing data selection methods usually score image-text pairs as holistic units, without separating visually necessary samples from shortcut-solvable ones. To address this problem, we propose ViCoR, a counterfactual-residual-based data selection method for Med-VLM fine-tuning. ViCoR estimates visual necessity through image-dependent optimization residuals, calibrates the resulting scores with medical supervision compatibility, and constructs a diversity-aware fine-tuning subset. Across two backbones, four external generalization benchmarks, and one multi-disease robustness benchmark, ViCoR-selected 20\% subsets achieve the strongest average performance compared with full-data fine-tuning and selection baselines. Gradient-level analysis and perturbation audits further show that ViCoR enriches image-dependent training signals and strengthens image-level and evidence-region dependence. The code will be available at https://github.com/htgan-ai/ViCoR.

0.40

Large-Small Model Collaboration for Zero-Shot Surgical Phase Recognition

cs.CV ·2026-08-24 ·Yiyi Zhang, Ying Zheng, Wenxin Fan, Yu Zhu, Yuchen Yuan +3 more
top venuecode/data similarity 0.63
Abstract · MICCAI 2026 Early Accept

Task-specific lightweight models for surgical phase recognition excel at capturing temporal dynamics but generalize poorly under domain shift. Conversely, surgical foundation models (FMs) offer superior transferability via large-scale pretraining, yet their lack of explicit temporal modeling often yields temporally inconsistent predictions, leading to degraded performance. To exploit the complementary strengths of both paradigms, we propose \textbf{La}rge-\textbf{S}mall \textbf{T}emporal adaptation (\textbf{LaST}), a novel large-small collaborative framework that enables zero-shot adaptation to unseen clinical domains. In LaST, the FM initiates the pipeline by generating frame-level phase priors that serve as initial weak supervision. To effectively utilize these noisy phase priors, we introduce an iterative temporal refinement scheme that integrates dynamic quality control to filter reliable predictions and dual-model cross-learning to mitigate confirmation bias. Simultaneously, the lightweight model leverages its intrinsic temporal modeling ability to progressively correct inconsistent predictions and enhance overall accuracy across iterations. At the end, a cycle replay strategy is employed to close the loop: the refined, more accurate predictions are utilized as upgraded supervision signals for the subsequent iterations, fostering a self-reinforcing evolution of both label quality and model capability. Extensive experiments demonstrate that LaST achieves robust adaptation to unseen domains for zero-shot surgical phase recognition, outperforming the baseline (PeskaVLP) by 24.85\%-43.17\% in accuracy and even surpassing fully supervised linear probing and several state-of-the-art few-shot approaches. Codes will be released at https://github.com/YIYIZH/LaST.

0.74

MedHarness: A Unified Budgeted Runtime for Reliable Medical Imaging Agents

cs.CV ·2026-11-17 ·Haofan Wu, Le Zhang
code/data similarity 0.63
Abstract

Medical imaging agents already return answers on heterogeneous imaging surfaces, yet deployment still faces a limited verification budget where each wrong accept can harm clinical trust. When a thin check and a deeper evidence pass disagree on the same case, deciding when to stop, open more evidence, repair, or reject without a shared controller remains ill-posed. Tool-using workflows often lock a surface-specific evidence order per dataset, or a private always-open full-depth verification path; those pipelines stay costly, leave many wrong accepts, and cannot share one controller across modalities. We present MedHarness, a registered multi-surface runtime reliability layer that reformulates post-answer control as shared decision-object attachment after a proposer's initial prediction. Under Shared Decision Object, Minimum-Sufficient Verification, and Intermediate Repair, one shared policy with surface recipe adapters lets a new imaging surface join the same stop / open-evidence / repair / reject controller by recipe registration. On a 512-case live pool, MedHarness cuts wrong accepts versus a full-verification baseline by about 47% and raises accepted accuracy to 83.2% vs. 72.9% at 86.1% coverage versus full release under that baseline. On a failure-enriched multi-surface stress ranking, the same controller cuts estimated remote service calls per case by about 71% versus that baseline under a matched context-load setting. A held-out three-surface check and an alternate language-model transfer keep the same control ordering. The code is available at https://anonymous.4open.science/r/MedHarness-paper-release-A7F3/.

0.36

From Generalist to Specialist: A Context-Fusion Framework for Endoscopic Polyp Reporting with a Frozen VLM

cs.AI cs.CV ·2026-08-16 ·Ruijie Yang, Yan Zhu, Peiyao Fu, Siyuan Li, Te Luo +5 more
similarity 0.62
Abstract

Reliable endoscopic polyp reporting requires integrating quantitative lesion sizing, standardized Paris classification, and clinically meaningful morphological description within a single record. General-purpose vision-language models (VLMs) offer a unified interface for image understanding and report generation. Existing specialization strategies, however, typically rely on task-specific models or model-weight adaptation, leaving unresolved how to introduce reliable specialist knowledge while preserving both this unified interface and the VLM's pretrained capabilities. We introduce a context-fusion framework that specializes a frozen general-purpose VLM through both implicit instruction context and explicit transduction context without modifying its pretrained weights. Specifically, a self-supervised polyp encoder retrieves related image-report pairs as explicit, query-specific evidence, while learned continuous specialist tokens provide implicit instruction context shared across cases. Experiments were conducted on 2,056 expert-annotated public endoscopic images. We compared the framework with general-purpose VLMs, task-specific predictors, and weight-adaptation methods to assess specialist performance, unified reporting, and adaptation efficiency. Across numerical, categorical, and report-generation metrics, the proposed framework substantially improved direct frozen-VLM inference and achieved the strongest overall performance among the evaluated methods. It added trainable parameters equal to only 0.006% of the frozen VLM's parameter count. When the top-1 retrieved case carried the correct target category, our framework corrected 70.5% of the errors made by a weight-adaptation baseline. These findings support the context-fusion framework as a lightweight and effective strategy for specialist adaptation of a frozen VLM.

0.04