CS Paper Radar

MedHarness: A Unified Budgeted Runtime for Reliable Medical Imaging Agents

Haofan Wu, Le Zhang

cs.CV ·submitted 2026-11-17 20:50 UTC · v1
code/data

Abstract

Medical imaging agents already return answers on heterogeneous imaging surfaces, yet deployment still faces a limited verification budget where each wrong accept can harm clinical trust. When a thin check and a deeper evidence pass disagree on the same case, deciding when to stop, open more evidence, repair, or reject without a shared controller remains ill-posed. Tool-using workflows often lock a surface-specific evidence order per dataset, or a private always-open full-depth verification path; those pipelines stay costly, leave many wrong accepts, and cannot share one controller across modalities. We present MedHarness, a registered multi-surface runtime reliability layer that reformulates post-answer control as shared decision-object attachment after a proposer's initial prediction. Under Shared Decision Object, Minimum-Sufficient Verification, and Intermediate Repair, one shared policy with surface recipe adapters lets a new imaging surface join the same stop / open-evidence / repair / reject controller by recipe registration. On a 512-case live pool, MedHarness cuts wrong accepts versus a full-verification baseline by about 47% and raises accepted accuracy to 83.2% vs. 72.9% at 86.1% coverage versus full release under that baseline. On a failure-enriched multi-surface stress ranking, the same controller cuts estimated remote service calls per case by about 71% versus that baseline under a matched context-load setting. A held-out three-surface check and an alternate language-model transfer keep the same control ordering. The code is available at https://anonymous.4open.science/r/MedHarness-paper-release-A7F3/.

Closest papers

Nearest neighbours by meaning across the whole index.

Reliability Stress Tests and Decision-Time Routing for Chest X-ray Vision-Language Models

eess.IV cs.CV ·2026-10-01 ·Xinye Yang, Zhusi Zhong, Scott Collins, Grayson Baird, Xuyu Wang +1 more
publishedbenchmarkcode/data similarity 0.66
Abstract · 6 pages, 4 figures, 5 tables. Accepted version of a workshop paper presented orally at the 2026 IEEE/ACM Conference on Connected Health: App…

Medical vision-language model (VLM) evaluation is sensitive to workflow design, prompting strategy, and benchmark construction, yet most studies treat these factors in isolation. We introduce a reliability stress test for chest X-ray interpretation built on two balanced datasets (a private report-backed set and a curated MIMIC subset). Three medical VLMs (CheXagent, MedGemma-4B, and MedGemma-27B) are evaluated across three prompt styles and two workflows (single-VLM and multi-agent), producing 36 configurations. We show that exact-match accuracy alone can overstate the effectiveness of conservative models that default to "Normal" predictions. Diagnostic reliability also depends heavily on model family and scale: multi-agent reasoning helps some configurations but hurts others. Building on these observations, we propose a decision-time routing framework that selectively escalates to multi-agent inference only when beneficial, improving the cost-quality trade-off over fixed workflows. Our results highlight the need for evaluation protocols that jointly consider prompt sensitivity, failure-mode diversity, and workflow choice before clinical deployment.

0.70

MediSkill-Evo: Process-Constrained Self-Evolution for Evidence-Grounded Clinical Interaction

cs.AI ·2026-08-24 ·Ruoyu Wu, Shenfu Xie, Yinqian Sun, Haibo Tong, Feifei Zhao
code/data similarity 0.66
Abstract

Interactive clinical agents operate under partial observability, so reliable care depends on reaching the correct diagnosis through evidence-grounded, safe interactions. Yet existing agents struggle to convert experience into reusable process knowledge with explicit provenance and authority. To address this gap, we introduce MediSkill-Evo, which self-evolves governed process knowledge without fine-tuning the backbone. It realizes this self-evolution by updating clinical, process, symbolic, and visual knowledge in four typed banks under type-specific validation and scope rules. The Process-Constrained Preference Harness then turns validated knowledge into action by grounding candidates in evidence and prioritizing safer decisions. We evaluate on 300 MIMIC-IV-derived FullChain encounters, 180 hard-isolation conditions covering six process obligations, and 100 multimodal NEJM image-diagnosis cases. On Qwen FullChain, MediSkill-Evo improves diagnosis accuracy by 7.81% and treatment-intent coverage by 70.67% over the best-performing prior agent, while reducing critical failures by 43.04%. Under stress, it improves the stress-process composite by 7.77% and required-action completion by 12.41% over the best-performing agent for each metric, with stronger patient-fact, temporal-evidence, and triage-red-flag recovery and no controller-scored errors in unavailable-evidence, treatment, and triage safety checks. On multimodal NEJM diagnosis, MediSkill-Evo with optional MedSAM localization improves diagnosis accuracy by 2.56% and core score by 18.96% over the best-performing memory agent. Code is available at https://anonymous.4open.science/r/mediskill-evo_anonymous-68E7.

0.66

Auditing Escalation Reliability in Healthcare LLM Agents: A Perturbation-Controlled Benchmark of Workflow-State Failures

cs.AI cs.CL ·2026-10-15 ·Zihao Zheng, Junyi Yao, Baichuan Li, Jiayu Long
benchmark similarity 0.63
Abstract · 8 pages, 5 figures

Trustworthy biomedical AI requires reliable action selection when evidence is missing, stale, conflicting, or late, not only accurate answers on static inputs. We instantiate an episode-level evaluation protocol as 400 synthetic healthcare workflow episodes: 40 hand-authored semantic seeds across four task classes, two surface parameterizations, and five controlled variants, scored on ANSWER/ASK CLARIFICATION/ABSTAIN/ESCALATE under a pre-declared 5:1 missed-versus-unnecessary escalation cost. Reference actions are single-author study-policy labels, not clinician-adjudicated ground truth. Across five open-weight configurations (1.7B--9.7B), clean decision accuracy reaches 0.97, yet uncertainty-prompted models miss 32--97% of required escalations. The stronger 9.7B configuration narrows but does not remove the gap, falling from 0.97 clean accuracy to 0.78 under conflict. Verbalized confidence is inconsistent (ECE 0.10--0.54; failure AUROC 0.48--0.77), and a development-tuned confidence-only policy yields no utility gain. A transparent workflow-aware controller improves 5:1 utility for every model and reduces missed escalations to 0.12--0.24, at specificity 0.83--0.93. However, a 30-concept lexical stress test reduces each rule detector's recall from 1.00 on trigger phrases to 0.00 on unseen paraphrases, limiting the controller claim to this benchmark. Seed-clustered statistics, ablations, cross-task transfer, raw outputs, and manifests are packaged for audit. The results motivate explicit workflow-state evaluation while showing that apparently effective routing controls need their own generalization tests.

0.46

ImageRSI: Verification-Driven Recursive Self-Improvement for Agentic Image Generation

cs.CV cs.AI ·2026-10-23 ·Shuo Han, Zhilin Wang, Peng Ling, Wenjia Gong, Yang Liu +3 more
benchmark similarity 0.63
Abstract

Complex text-to-image requests remain difficult to satisfy reliably. Verifying and repairing an image can fix an individual output, but a successful repair does not necessarily carry over to other requests. We present ImageRSI, a framework that keeps the image generator frozen and combines three components: five-dimensional verification and repair within each task, an experience library shared across tasks, and offline updating of the judge. Candidate experiences enter the library only after paired A/B validation, and the judge is updated with supervised fine-tuning and GRPO on accumulated image-judgment records and evaluated before reuse. We also introduce ImageReq-Bench, a benchmark of 961 requests built around hard cases in real-world image-generation requests, each paired with an evaluation checklist. ImageRSI achieves a Checklist Strict Accuracy (CSA) of 52.6% on MindBench (with Nano Banana Pro as the generator) and 65.66% on ImageReq-Bench, and we compare system outcomes across judge-training configurations.

0.35

MedImageOSWorld: Benchmarking GUI Agents for Medical Image Consoles

cs.AI cs.CV ·2026-10-03 ·Ziyang Long, Xinqi Li, Lujing Xing, Hsin-Jung Yang
benchmark similarity 0.63
Abstract · 11 pages, 3 figures. Supplementary material (8 pages) included as an ancillary file

Graphical consoles offer a practical interface for medical acquisition assistance, allowing agents to work through the controls and visual feedback used by human operators. Reliable assistance requires linking on-screen anatomy to acquisition decisions that determine what image evidence becomes available next. We introduce MedImageOSWorld, a benchmark for evaluating this capability in simulated CT, MR, and ultrasound consoles. Using screenshots and mouse-and-keyboard actions, agents configure protocols, plan acquisitions, inspect the resulting images, and make corrective adjustments across seven capability levels, from console operation to feedback-driven control. Evaluation combines task-specific workflow checks with hidden anatomical ground truth to assess procedural completion and acquisition outcomes separately. A common evaluation protocol specifies episode conditions and interaction budgets, while recorded trajectories support analysis of how agents observe, act, and respond to acquisition feedback. Across eleven open-weight agents, success rates range from 3.0 to 25.0 on a 0-100 scale while workflow-progress rates reach 21.5-74.5: agents complete much of the console workflow but rarely acquire the intended anatomy. Success collapses between perception and planning, from 79-90% at the lowest three levels for the best agent to at most 12% for millimetre-level planning and 0% for closed-loop control among open-weight agents. Two proprietary agents reach success rates of about 34 and exceed the best open-weight agent mainly in acquisition quality (61 versus 42). MedImageOSWorld provides a controlled setting for studying whether general-purpose GUI agents can translate visual observations into effective medical acquisition decisions.

0.37

From Few-Shot Segmentation to Clinician-in-the-Loop Medical Image Analysis

cs.CV ·2026-09-09 ·Yazhou Zhu
similarity 0.63
Abstract · 25 pages, 3 figures, 5 tables. Perspective article

Few-shot medical image segmentation (FSMIS) seeks to delineate unseen structures from a small support set, but its standard formulation fixes task-defining evidence before inference. This assumption is fragile under acquisition shift, atypical pathology, ambiguous boundaries, and poor image quality. Adding clinician interaction and rapid adaptation is not sufficient: the binding constraint is deciding when asking or changing is warranted. We therefore reframe FSMIS as a three-layer sequential decision problem. First, decidable self-assessment separates errors that a bounded intervention can repair from those that no admissible intervention can reach. We formalize this distinction through a correctable set defined by the update operator and remaining interaction budget. Second, selective interaction allocates a distinct expert-attention budget by response-conditioned net expected value of information, yielding explicit accept, query, and defer actions. Third, bounded adaptation emphasizes reversibility and independent safety reassessment rather than speed. A complementary cross-case memory stores reproducible correction priors over failure modes instead of disease-specific mask priors. This structure links sparse support representation, cross-domain robustness, multi-level risk estimation, clinician feedback, and governed experience transfer. We state six hypotheses with an explicit dependency order and propose a minimal pilot that can falsify the foundational self-assessment claim before a clinician study. The central claim is not that interaction resolves domain shift, but that scarce expert attention should be used only when a bounded intervention is expected to reach a clinically better outcome.

0.29

CARE: Confidence-Aware Reasoning for Reliable Medical VQA

cs.CV cs.AI ·2026-08-11 ·Yuetian Du, Yucheng Wang, Zhenyuan Chen, Luyuan Chen, Rongyu Zhang +7 more
top venuecode/data similarity 0.63
Abstract · Accepted by MICCAI 2026

Reinforcement Fine-Tuning (RFT) has enabled medical Multimodal Large Language Models (MLLMs) to produce Chain-of-Thought (CoT) reasoning for visual question answering, yet these models suffer from $\textit{confidence miscalibration}$---a systematic gap between expressed certainty and actual diagnostic accuracy that undermines clinical trust. We propose $\textbf{CARE}$, a $\textbf{C}$onfidence-$\textbf{A}$ware medical $\textbf{RE}$asoning framework that jointly optimizes accuracy and calibration through a dual-stage pipeline. First, a scalable Medical-CoT synthesis provides structured cold-start data for Supervised Fine-Tuning. Second, Group Relative Policy Optimization (GRPO) with a novel $\textbf{Confidence-Aware Reward (CAR)}$ mechanism ties the model's confidence to diagnostic correctness within the reward signal. Across three Medical VQA benchmarks, $\textbf{CARE}$ achieves the highest diagnostic accuracy while obtaining the lowest Expected Calibration Error and Hallucination Rate, establishing a foundation for trustworthy clinical decision support. Our code is available at https://github.com/anotherbricki/CARE.

0.49

MedHarnessBench: A Unified Benchmark for Healthcare Agent Evaluation

cs.AI ·2026-10-11 ·Rui Tang, Hongqiu Wang
benchmarkcode/data similarity 0.63
Abstract

Healthcare agents must transform longitudinal clinical evidence into reliable actions through heterogeneous tools and stateful workflows, conditions under which model-centric systems may lose context, misuse tools, fail to verify consequential transitions, or cross authorization boundaries. Existing medical-agent benchmarks primarily emphasize terminal task outcomes, making it difficult to determine whether execution failures arise from the agent model, the runtime harness, or their interaction. We present the Medical Harness Protocol, an outcome-preserving framework that independently evaluates seven healthcare-specific process dimensions: Care Action Fulfillment, Clinical Resource Competence, Patient-Evidence Alignment, Clinical Workflow Continuity, Clinical Auditability, Closed-Loop Verification, and Clinical Conduct Boundaries. A normalized intervention trace further tracks whether runtime support is available, activated, delivered, adopted by the agent, and propagated into subsequent behavior. We instantiate the protocol as MedHarnessBench, comprising 342 executable tasks across FHIR/EHR operations, healthcare-administration interfaces, and multimodal clinical tools. Across more than 16,000 controlled task executions, MedHarness yields broad improvements in terminal task success, intermediate subtask completion, and healthcare-specific process quality. We further evaluate MedHarness against multiple general-purpose harnesses and use controlled single-fault perturbations to verify the sensitivity and discrimination of the seven-dimensional evaluation. These results demonstrate that healthcare-specific runtime support can substantially improve both task completion and execution quality, while revealing failures that terminal outcomes alone cannot capture. Code and resources are available at https://github.com/Tomry1114/Awesome-Agent-Harness-for-Healthcare.

0.20