CS Paper Radar

Certified AI Triage of ICU Alarms

Mohammed Sameer Syed, Rozhin Yasaei

cs.LG ·submitted 2026-09-11 02:34 UTC · v1
benchmark

Abstract

In the VTaC benchmark 71% of ventricular-tachycardia alarms are false, but silencing a real one can delay recognition of a dangerous arrhythmia. We reframe alarm reduction as three-way triage (retain, suppress, or defer) and bound the decision this analysis treats as harmful: among suppressed alarms, the fraction that were genuine stays below a user-set budget with 95% confidence, under i.i.d. event sampling. Alarms sharing a waveform record are dependent, so the clustered analysis is a sensitivity check. On the official split a 5% budget certifies in all three seeds, suppressing 74.8% of false alarms while silencing 1.5% of genuine ones, at AUROC 0.953 and Challenge Score 83.33, numerically comparable to the strongest of the eleven published systems. Our central finding measures what multiplicity costs: the correction charges for every candidate, so a finer grid can certify strictly less. Under held-out calibration the 885-cell grid we declared certifies 1 of 15 fold-runs, while choosing the grid on a separate selection partition certifies 8. We project the calibration volume each budget needs, making an uncertifiable budget a design parameter. Finally, adding a learned reliability dimension to the policy grid did not sharpen the certified frontier.

Closest papers

Nearest neighbours by meaning across the whole index.

Alert-List Concordance for Evaluating Imputation Strategies in ICU Sepsis Prediction

cs.LG q-bio.QM ·2026-10-15 ·Priyanka Siddappa, Muntaqim Ahmed Raju, Shifat Haider Al Amin, Ruizhe Ma
published similarity 0.56
Abstract · 8 pages, 2 figures. Accepted at the 14th Workshop on Data Mining in Biomedical Informatics and Healthcare (DMBIH 2026), held in conjunction …

Preprocessing is an under-measured reliability risk in clinical prediction: a model can keep a similar AUROC and still change who receives an alert. Imputation quality is commonly evaluated using reconstruction error or aggregate discrimination, neither of which directly measures agreement on which patients are flagged. At a matched alert rate, pipelines with similar aggregate performance can produce different patient lists. This question is especially relevant under the frequent, structured missingness of real ICU records. We therefore introduce alert-list concordance, which asks whether two pipelines identify the same high-risk patients, measured by the Jaccard similarity of their top-k% alert sets with patient-level bootstrap confidence intervals. On PhysioNet/CinC 2019 (40,336 patients, 71.9% missingness), we compare nine imputation strategies and a native-missingness baseline using a fixed XGBoost configuration, fitted and Platt-calibrated separately for each strategy. After Bonferroni correction, 22 of the 28 reconstruction-method pairs showed no statistically significant difference in patient-level AUROC, yet their alert lists overlap at Jaccard 0.518 to 0.750. Similar aggregate discrimination can therefore accompany different patient selections. ForwardFill is a separate outlier, pairing higher discrimination with the lowest overlap in the matrix, 0.40 to 0.45. The broad pattern holds within each hospital system and under six patient-level aggregation rules. At the row level, eight of ten methods fall within an AUROC range of 0.011. In this row-level pipeline, deep imputers did not outperform mean imputation on discrimination, and the sequential implementations cost 5 to 12 times mean imputation in total pipeline wall-clock time on our hardware.

0.54

Sensor-Free Shockable Rhythm Classification During CPR Using the Existing ECG Channel of Public-Access Automated External Defibrillators

eess.SP ·2026-11-19 ·Jaechan Lim, David Hicks, Matt Valentine, Ki H. Chon
similarity 0.54
Abstract

Automated external defibrillators (AEDs) are public-access devices intended for use by lay rescuers, yet they must pause chest compressions to analyze the rhythm because compressions corrupt the electrocardiogram (ECG). Removing this pause requires a method that uses the hardware already present in the device, fits within its processor budget, and meets the rhythm-recognition performance required for defibrillator approval. Existing approaches rely either on an auxiliary sensor, which entails a hardware redesign, or on an additional network that reconstructs the ECG before classification. This work classifies the compression-contaminated ECG directly, using only the existing ECG channel of the AED. A cascade of three compact convolutional networks trained with different class ratios verifies each decision with a second network biased toward the proposed outcome; disagreement yields an indeterminate outcome. Evaluated on an independent manufacturer-provided cohort of 464 subjects over 15 train-validation partitions, the cascade satisfies both adjudicable American Heart Association criteria under all six noise conditions at an eight-second window and a signal-to-artifact ratio of 0 dB, with sinus-rhythm specificity of 99.20-99.43% and other non-shockable specificity of 95.48-96.20%, leaving only 1.07-1.48% of segments indeterminate. The criteria are not met at -3 dB. Single networks matched in parameter count and inference cost do not reproduce this performance. Each decision evaluates two of the three networks and requires 6.68 ms on a single thread of a general-purpose processor, and eight-bit quantization reduces the model to 1.45 MiB without changing any compliance verdict. Thus, rhythm analysis during ongoing CPR can be implemented with the ECG hardware already present in public-access AEDs, without auxiliary sensing hardware, subject to validation on the target device.

0.17

Target leakage, not model class, explains reported accuracy in survey-based cardiovascular screening: a leakage-tiered audit of glass-box and tabular foundation models

cs.CL ·2026-09-10 ·Raad Bin Tareaf, Murad Al-Rajab, Samia Loucif, Samer Ellaham, Cedric Schmitz
hot direction similarity 0.53
Abstract

Cardiovascular screening models trained on national health surveys routinely report areas under the receiver operating characteristic curve (AUROC) near 0.89. We asked whether that accuracy reflects learning or target leakage, whether tabular foundation models change the answer, and whether the properties deployment requires survive joint examination. We benchmarked ten classifiers spanning linear, tree-ensemble, neural, glass-box, and tabular foundation classes for prevalent myocardial infarction in 442,067 respondents of the 2022 Behavioral Risk Factor Surveillance System across five feature tiers of decreasing leakage risk. Each was audited for discrimination, calibration, fairness at an explicit screening threshold, conformal coverage, explanation faithfulness, and inference cost, then applied -- models and thresholds frozen -- to 430,755 respondents of 2023. Removing two post-diagnostic features cost every model 0.049-0.051 AUROC, collapsing the field into a 0.0045-wide band. The glass-box explainable boosting machine was non-inferior to every alternative within a pre-specified 0.005 margin while scoring the cohort roughly 104 times faster than the strongest foundation model. One threshold detected 75.4% of women's infarctions against 89.0% of men's; editing the model's shape functions reduced the gap to 0.010. Marginal conformal prediction gave 0.86 coverage to men and 0.82 to adults over 60; Mondrian calibration repaired every stratum. Frozen models transported within 0.002 AUROC. Reported headroom in this literature is a property of the feature set, not the learner. Transparency cost nothing measurable and made fairness repair and uncertainty conditioning directly auditable. Evaluation practice, not model capacity, is the binding constraint.

0.37

Prevalence Determines Precision:Silent Contamination in Detector-Defined Datasets

cs.LG cs.AI ·2026-09-10 ·Jia Huang, Yankai Wan, Yangjun Ou
similarity 0.52
Abstract · 9 pages

Many ML datasets are constructed by running a detector, heuristic, or model over candidate pools; accepted items become labels. Dataset precision is then governed by true-positive prevalence in each pool via Bayes, not solely by detector quality. Using one instrument and period, we hold a detector-defined event dataset plus an independent official index labeling every detected item as real or phantom. One detector, three pools yield phantom rates 81.7%, 9.0%, and 0.0%. Transferring precision from the two high-rate pools to the low-rate pool predicts 0.955 versus measured 0.183, a +422% error; the Bayes expression predicts all three within 3.3%. The detected response curve is an exact convex combination of a true-event and a phantom component (residual 1.1e-16), with phantoms outnumbering true events 473 to 308, so contamination is a second signal with detector-inherited shape, not additive noise. Contamination direction depends on the estimator: on identical windows one statistic is diluted and another inflated because its denominator is also contaminated. A common normalization turns the estimator into a mean of ratios whose expectation need not exist; on the same 335 events it returns 0.40 where the well-defined estimator returns 0.10.

0.29

CURA: Certified Runtime Alarms for Computer-Use Agents

cs.AI cs.CVcs.LG ·2026-08-28 ·Divake Kumar, Sina Tayebati, Devashri Naik, Amanda Sofie Rios, Nilesh Ahuja +3 more
similarity 0.51
Abstract

Self-report is the cheapest oversight channel a deployer has, and on capable computer-use agents (CUAs) it fails precisely where oversight matters. On 361 OSWorld tasks our pipeline, a read-only feasibility gate, a planner, and a GUI executor, reaches a mean task score of 82.9, above the 72.4 human reference, yet 64 of its 71 failures (90%) end with a success claim, 61 acknowledging no blocker, and the explicit failure affordance is never used in roughly 9,100 calls. We introduce CURA (Certified Runtime Alarms for Computer-Use Agents), an external monitor that reads only harness-visible telemetry, with no model internals, extra LLM calls, or prompt changes, and turns the running trajectory into a sequential test with certified false-alarm control. At alpha = 0.10 its CUSUM alarm detects 42.3% of failures a median of 31 steps before termination at a realized false-alarm rate of 0.066, and risk is partly resolvable before the first action (gate probe, 0.69 AUROC). Retrospectively the composite reaches 0.828 AUROC (fold-internal floor 0.802), but its margin over a total-token baseline is not significant (Delta = +0.026, p = 0.101); the separation is online, where CURA recalls more at matched certified budgets: 0.41 versus 0.34 at alpha = 0.10, 0.56 versus 0.38 at alpha = 0.20. Alarm-gated mid-execution oversight recovers 23 of 70 failures while spending a frontier overseer on 38, giving a deployable cascade at mean score 86.8 and 84.5% full-solve (305 of 361). The certificate bounds false alarms only. We also report where behavioral monitoring is uninformative.

0.39

The Price of Self-Calibration: Exact Evidence Budgets and Manufactured Blind Sets in Adaptive Monitoring

cs.LG eess.SYmath.PRstat.ME ·2026-09-19 ·Abdou-Raouf Atarmla
unusual similarity 0.51
Abstract · 15 pages, 3 figures, 3 tables

Self-calibrating monitors adapt their threshold online to guarantee a prescribed long-run false-alarm rate under arbitrary drift. We compute the price of that guarantee, stating every law with its exact domain of validity. First, the guarantee is an accounting identity, insensitive to what the monitor is meant to detect. Two evidence identities make the cost exact for the online quantile tracker: a persistent step of height $δ$ yields excess alarm mass within one alarm of $δ/η$, and exactly $δ/η$ pathwise when $δ$ is a lattice multiple of the gain $η$; a ramp of slope $c$ yields a stationary excess rate of exactly $c/η$, independent of accumulated size, up to a boundary $c=η(1-α)$ coinciding with the alarm-rate cap. Second, the certificate's own fluctuation obeys an exact law: the windowed alarm rate has standard deviation of order $1/L$, not the binomial $1/\sqrt{L}$, since the windowed mass telescopes to a difference of a tight internal state; the closed-form constant is validated with no fitted parameter. Detectors calibrated on the binomial scale are miscalibrated by $\sqrt{η\varphi(q_0)L}$, and correct calibration turns detection windows from quadratic to linear in the inverse fault speed. Third, any monitor required to tolerate a drift class $\mathcal{D}$ is blind, at any horizon and for any rule, to every fault in $\mathcal{D}-\mathcal{D}$; the proof is a deliberately elementary two-point argument and the contribution is the object it identifies: for speed-bounded classes the blind set is exactly the doubled-speed class, and the tracker absorbs a speed class fixed by its own gain, so that under a certification regime declaring absorbed drift normal, the monitor manufactures $\mathcal{D}$. An exact Gaussian projection bound, sharper than Pinsker and never vacuous, quantifies power outside it.

0.33

COGNIT-Guard: Calibrated Standalone Direct-Decision Guardrails with Heterogeneous CPU-NPU Confidence Cascading under Explicit Latency and False-Positive Constraints

cs.CR cs.LG ·2026-09-27 ·Hao Chen
similarity 0.51
Abstract · 7 pages, 2 figures, 5 tables, IEEE double-column format

When must a foundation-model safety gateway generate tokens, and when should it directly output a calibrated decision? We study calibrated standalone direct-decision foundation models for real-time pre-ingestion safety guardrails, jointly addressing probability calibration, dual-use false-positive control, and heterogeneous CPU-NPU routing under explicit latency SLOs. Pre-ingestion guardrails must screen prompts prior to target-LLM prefill with low false alarms on benign compliance inquiries; however, shallow classifiers are brittle to phrasing shifts, hidden-state probes require coupling to a target LLM, and generative guards incur high decoding latency and dual-use false positives. We present COGNIT-Guard, coupling a validation-calibrated CPU fast gatekeeper with confidence-gated escalation to an NPU-resident 322M bidirectional direct-decision model (Laya-322M) under an asymmetric false-positive penalty. On the clean unseen DUCS-Bench test split ($N=607$), COGNIT-Guard achieves 98.85% accuracy (McNemar $p = 1.19 \times 10^{-4}$ vs. ML), reduces benign FPR to 0.42% ($1/238$; Fisher's exact $p = 8.23 \times 10^{-4}$ vs. ML), and attains 1.12% ECE and 0.0104 Brier score. On Huawei Ascend 910C NPUs, pure NPU inference runs in 21.77 ms mean latency (45.90 QPS), while the live serial CPU-NPU cascade ($θ^*_{\mathrm{deploy}}=0.70$) achieves 41.63 ms mean latency (P50: 39.47 ms, 99.23% accuracy, 0.00% FPR). Evaluation on SafetyBench-ZH ($N=2,100$) and comparison against a bi-encoder direct-decision baseline (CLM-8B) disentangle in-domain gains, OOD alignment tax (60.33% $\to$ 56.81% on Laya; 55.10% on domain CLM-8B), and experience replay recovery, restoring OOD accuracy to 64.10%-65.05% and reaching 99.67%-99.84% in-domain accuracy with 0.00%-0.42% FPR.

0.18

The Price of Scale in Proactive Memory Recall

cs.CL cs.AIcs.IRstat.ML ·2026-10-25 ·Yichuan Chen, Xin Wang
benchmarktheorycode/data similarity 0.51
Abstract · v3: latency now measured on the released code; recalibrated chronological thresholds; adds a chronological null check; restates the finite-p…

A long-lived assistant that brings up memories without being asked must decide at every turn whether anything in its store is worth an interruption. We show that this decision is a multiple-testing problem whose difficulty grows with the store size N. On replays of LongMemEval, a similarity threshold tuned to 5% false alarms at N=8 reaches 84-100% at N=2048 across embedding models and cue types; LoCoMo and LLM judges show it too. We prove that a gate which thresholds the best of N independent irrelevant scores at false-alarm rate alpha operates at a per-item false-positive rate of about -ln(1-alpha)/N, which pins its hit rate to the far left of the ROC and makes it regularly varying in N under regular variation. Replayed hit rates stay within its bounds for mixed cues up to 0.3 points, and hit rates carry over to held-out questions to within 6.0 points. At matched false alarms the deployed score recalls 14-26 points more than raw cosine. A cue-swap conformal gate, which ranks the current cue among other cues on the same store, has a finite-sample false-alarm guarantee under exchangeability. With a background from the user's unfiltered history it keeps false alarms at 3-6% on LongMemEval at the hit rate of a label-tuned threshold; on LoCoMo it overshoots or turns conservative depending on the source of its reference cues. In a chronological replay with the user's own earlier messages as references, it fires on 5-8% of questions on stores without their answer and on 6-8% of session-opening turns, against 57% for the deployed gate at N=2048, at a median 0.4 s CPU per decision. A cross-encoder pays the same price of scale, and on a prospective-memory benchmark, similarity gates recall at most 9% of constraints at controlled false alarms. One human and two LLM annotators judge most false alarms unhelpful for a response. Code and data: https://github.com/RiverChenStillCompiling/price-of-scale

0.32