CS Paper Radar

Scaling Clinical Judgment to Evaluate Medical AI

Thomas A. Buckley, Zahir Kanjee, Peter G. Brodeur, Byron Crowe, Anthony M. Pettinato, Aashna P. Shah, Adrian D. Haimovich, Liam G. McCoy, Daniel Restrepo, Jason A. Freed, Ethan Goh, Jonathan H. Chen, Laura Zwaan, Katherine E. Goodman, Daniel J. Morgan, Raja-Elie E. Abdulnour, Adam Rodman, Arjun K. Manrai

cs.AI ·submitted 2026-09-11 13:20 UTC · v2
benchmark

Abstract

Blinded physician evaluation has been considered by many to be the gold standard for assessing clinical reasoning in large language models (LLMs). This is difficult to scale; thus, prior studies typically rely on small physician panels, often from a single institution or specialty, which both limits the scientific questions investigated and makes it unclear whether findings would be reproduced with a different set of evaluators. To more rigorously and scalably study clinical reasoning in AI models, here we introduce PrecepTron, an LLM fine-tuned for physician-level evaluation of open-ended responses. PrecepTron was trained using low-rank adaptation (LoRA) of a 32-billion-parameter model on a small number of physician examples. We also release GRAND-ROUNDS, a new large-scale physician-annotated benchmark of 9,217 scored responses from 160 clinicians across seven studies. We show that frontier LLMs in typical "LLM-as-a-judge" approaches often disagree with physicians and with each other, but fine-tuning PrecepTron on a small number of cases enables physician-level consistent scoring across tasks. We use PrecepTron to reproduce headline findings from five influential studies assessing LLMs for clinical care in JAMA, Science, and Nature Medicine without new human grading. Using PrecepTron, we then pose new questions about how LLMs reason in medicine that would have been infeasible with human grading alone, including measuring the diagnostic accuracy of frontier LLMs when clinical cases are provided piecemeal, even token by token. Together, PrecepTron and GRAND-ROUNDS provide a foundation for reproducible, large-scale study of how LLMs reason in medicine. All code, data, and labels are made freely available for researchers.

Closest papers

Nearest neighbours by meaning across the whole index.

DocTalk: Enhancing Medical Knowledge Retrieval via Fine-tuned Large Language Models with Chain-of-Thought Reasoning for Robust Clinical Decision Support

cs.AI cs.CLcs.CV ·2026-10-26 ·Asad Gohar, Md Ariful Islam Mozumder, Moon-Il Joo, Hee-Cheol Kim
code/data similarity 0.74
Abstract

Objective: The rapid advancement of large language models (LLMs) in healthcare has opened new possibilities for AI-assisted clinical decision-making; however, safe and effective deployment remains challenging because of hallucination and domain misalignment. This study introduces DocTalk, a doctor-assistive question-answering (QA) system designed to generate concise, chart-grounded responses from de-identified discharge summaries. Methods: We developed a high-fidelity data generation pipeline that produces 500 clinically relevant QA pairs through sentence-level decomposition, chain-of-thought-guided question formulation, and expert review. Six open-source LLMs, including three general-purpose and three biomedical models, were evaluated before and after parameter-efficient instruction tuning using Low-Rank Adaptation (LoRA). The framework integrates prompt engineering, in-context learning, and medically aligned evaluation to support factual and interpretable responses. Results: On DocTalk-QA, instruction tuning produced consistent improvements across lexical, semantic, and clinical fidelity metrics. The best-performing tuned model, Llama-3-Med42-8B, achieved ROUGE-L = 0.40, BERTScore-F1 = 0.76, and UMLS-F1 = 0.49. To examine external generalization beyond the DocTalk-QA dataset, the two best-performing models, Llama-3.1-8B-Instruct and Llama-3-Med42-8B, were evaluated on PubMedQA before and after instruction tuning. Accuracy improved from 0.931 to 0.977 for Llama-3.1-8B-Instruct and from 0.935 to 0.943 for Llama-3-Med42-8B. Conclusion: DocTalk was deployed as a secure web-based platform for interactive EHR querying. These findings suggest that clinically grounded instruction tuning can improve medical QA performance and support practical clinical decision support.

0.26

An evidence-traceable benchmark of clinical reasoning in large language models

cs.CL ·2026-11-10 ·Zhiqun Zhao, Xiaodong Yang, Bruce Gu, Ming Li, Yi Fu +11 more
benchmark similarity 0.70
Abstract · 25 pages, 8 figures, 4 tables. Zhiqun Zhao, Xiaodong Yang and Bruce Gu contributed equally. Corresponding authors: Zheng Wang, Haiquan Lu an…

Benchmark scores for medical large language models (LLMs) are difficult to interpret when scoring criteria cannot be traced to clinical evidence. Here we developed Med Evidence Bench (MEB; https://www.medevidencebench.org.cn/), comprising 1,536 physician-constructed items across three levels: guideline knowledge, standardized clinical scenarios and real-world laboratory scenarios. Each criterion stating a medical claim is linked to a versioned source-text span. Across ten LLMs, the Evidence Trace Score (ETS) was 0.975-0.997 for guideline knowledge, 0.292-0.658 for standardized scenarios and 0.182-0.447 for real-world scenarios, and rankings varied across levels. For real-world scenarios, scores for identifying clinical information (mean, 0.770) exceeded those for matching evidence (0.165) or formulating recommendations (0.160). On 1,296 criterion-level judgments, automated grading agreed with the majority vote of three physicians (macro-F1, 0.930; 95% confidence interval, 0.915-0.945), although agreement was lower for evidence application. These findings from Chinese-language materials indicate that guideline recall does not ensure patient-specific evidence use and do not establish clinical effectiveness.

0.25

A general-purpose System One decision model for clinical records

cs.AI ·2026-10-19 ·Andrew Zhang, Trinh T. L. Vuong, Sophia J. Wagner, Dongmin Bang, Tong Ding +12 more
similarity 0.70
Abstract

Clinical care, health-system operations and biomedical discovery depend on extracting reliable answers from patient records, yet applying diverse clinical questions across entire populations remains computationally expensive. Here we present Clinical System One (CS1), a 4-billion-parameter decision model for fast, typed judgments from clinical records, along with two agentic harnesses in which CS1 works together with a generalist language model. CS1-4B is trained on 12.4 million questions and answers from 3.6 million patients across a multi-hospital health system, combining structured-data keys, observed outcomes and language-model supervision across clinical notes, diagnostic reports and patient timelines. It answers multiple typed questions in a single forward pass without task-specific retraining, and each answer carries a probability that can route uncertain cases to human review. On 963,408 held-out patients, CS1-4B outperformed open decision models up to 27 billion parameters on 13 of 14 tasks scored independently of its training teacher. Across 21 external data sets, its aggregate performance approached that of the strongest tested 27-billion-parameter model, with 6.4-fold faster inference in a matched workload. Integrating CS1-4B with a language model agent produced cited answers over complete multi-year patient histories and screened a patient population against the eligibility criteria of 17 registered clinical trials, placing four times as many judged-eligible patients among its top 20 candidates as keyword search while using 690-fold fewer language-model tokens than a language model reading every record. These findings support a division of labour in clinical AI, with small decision models performing repeated record reading and generative models formulating questions and synthesizing evidence.

0.42

From Small to Large: Assessing Medical Reasoning, Benchmark Contamination, and Model Size in Language Models

cs.AI cs.CL ·2026-10-30 ·Navapat Nananukul, Mayank Kejriwal
benchmark similarity 0.70
Abstract

Large language models (LLMs) now answer medical exam questions at or above expert level, but it is unclear whether such scores reflect clinical competence, or are instead affected by the format of the questions being asked (e.g., multiple-choice versus open-ended), prior exposure to the benchmarks, and the difficulty of the questions. These benchmarks are also public and widely used online, which may be resulting in LLM memorization. Models may perform better on questions that they have seen before. It is also not evident whether smaller models, which are more locally deployable in HIPAA-compliant hospital settings, have achieved human performance. In this study, we evaluate fourteen current models from six leading providers, one smaller and one larger model from each provider with two additional open-weight models, on 3,076 questions from four medical benchmarks (MedQA-USMLE, MedMCQA, PubMedQA, and MedBullets) under standard multiple choice, the same questions with the answer choices withheld, and reconstruction of a hidden question from its choices alone. In the standard multiple-choice setting, the strongest models exceed the human-expert baseline on MedQA-USMLE and PubMedQA, but the smaller models trail their larger models by 8.7 percentage points and only two of the six pass the human-expert bar on the licensing examination. Withholding the answer choices, however, makes every model struggle: mean accuracy falls from 82.3% to 50.9%, and the two largest drops belong to the medically specialised models. On memorization, the strongest models reconstruct one question in four from the answer choices alone, yet accuracy holds on the questions they cannot reconstruct. We further weigh accuracy against inference cost and test whether ensembling several models improves medical question answering.

0.15

PetQA: Benchmarking Veterinary Knowledge and Clinical Reasoning

cs.CL cs.AIcs.CV ·2026-09-04 ·Taegyun Kim, Youngwook Ham, Jungwook Rhim, Ju-Hyun An, Sungkyu Park +1 more
top venuesurveybenchmark similarity 0.69
Abstract · EMNLP 2026

We introduce PetQA, a Korean long-form question-answering (QA) benchmark for evaluating veterinary knowledge and clinical reasoning in large language models (LLMs) and large vision-language models (LVLMs). PetQA contains 10,076 text-only and 8,751 multimodal QA pairs derived from real-world questions about dogs and cats, paired with answers from expert veterinarians. Its test split, PetQA-Bench, further includes annotations for question types and clinical conditions. We evaluate eighteen models using ROUGE, BERTScore, and LLM-as-a-judge metrics for factuality and helpfulness under three settings: zero-shot inference, retrieval-augmented generation (RAG), and supervised fine-tuning (SFT). The benchmarking results provide an overview of the strengths and limitations of current models in addressing veterinary clinical queries and highlight the need for more effective adaptation methods to develop clinically reliable AI systems for veterinary care. To facilitate broader use, we additionally provide translated versions of PetQA-Bench in five languages.

0.37

Clinician use of language models diverges from how the models are evaluated

cs.CL ·2026-10-08 ·Krithik Vishwanath, Haitong Lin, Anton Alyakin, Jin Vivian Lee, D. Brock Hewitt +17 more
benchmark similarity 0.68
Abstract

Large language model (LLM) assistants are being deployed to clinicians across health systems, and judgments about their readiness rest largely on benchmark scores, most of them derived from examination questions or curated cases. A benchmark predicts performance in deployment only to the extent that its items resemble real use, yet whether benchmarks reflect the work these systems receive has rarely been measured. Here we analyze 127,833 queries sent by 6,342 physicians, advanced practice providers and nurses in 35 specialties to an institutional assistant during an eight-month roll-out. We characterize each query with RCQ-Map, a clinician-validated framework grounded in taxonomies of clinical questions and of LLM evaluation, which records its task, intent, answerability, missing information and potential harm. Documentation and administration (36.2%) and knowledge retrieval (28.9%) made up nearly two-thirds of use, and diagnosis 3.7%; more than a third of queries could not be answered well as posed. Applying RCQ-Map to 58 public benchmarks drawn from major evaluation suites and frontier model reports, which we assemble into the Clinical AI Benchmark Atlas, showed that the median benchmark contained no documentation requests and shared 31% of the task mix of real use, less than an even spread across task categories would. Benchmarks in suites designed to resemble clinical practice were individually no closer to real use than those used in frontier model reports. Benchmark scores therefore say little about how clinical AI performs on most of the work it is actually given, and evaluation should be matched to real clinical use.

0.08

Sense and Sensitivity: Benchmarking LLM Clinical Triage Recommendations with Physician Experts

cs.AI ·2026-09-29 ·Abinitha Gourabathina, Haoran Zhang, Yuexing Hao, Walter Gerych, Marzyeh Ghassemi
top venuebenchmark similarity 0.67
Abstract · Accepted to Findings EMNLP 2026 (Findings)

As large language models (LLMs) are increasingly used in clinical settings, it is critical to evaluate their reliability under realistic variation in clinical text. We study this question in clinical triage, comparing LLMs to practicing physicians under text perturbations that preserve the underlying clinical setting. We introduce a benchmark of over 6,000 clinical scenarios, 7,000 physician annotations, and 225,000 model responses. Using this benchmark, we make two key observations. First, LLMs are more likely than physicians to recommend unnecessary care at baseline, and this tendency increases under perturbed inputs. Further, we find that LLM recommendations are more sensitive to gender and tone perturbations than human recommendations. Together, these results demonstrate that LLMs can vary under clinically irrelevant textual changes, highlighting the need for deployment-oriented evaluations grounded in expert physician behavior.

0.31

A Living Benchmark for Information Retrieval from Electronic Health Records

cs.AI ·2026-09-24 ·Jordan L. Cahoon, Chloe O. Stanwyck, Sulaiman Somani, Philip Chung, Kevin R Keet +21 more
benchmark similarity 0.67
Abstract

Large language model (LLM)-based clinical assistants are increasingly being integrated into electronic health record (EHR) systems, transforming how clinicians retrieve and synthesize information from patient records. Their safety and utility depend on rigorous evaluation, yet existing benchmarks are manually curated, costly to update, and rapidly become obsolete with evolving technological advancements. We present a scalable framework that automatically generates question--answer pairs from longitudinal EHR notes. Nineteen clinicians validate the benchmark generator, producing the Benchmark for Retrieving Information in EHRs (BRIE), a continuously maintainable evaluation dataset. Across nine LLMs and five inference strategies, state-of-the-art systems frequently omit clinically important information, particularly for questions requiring synthesis across multiple documents and encounters. Because the generator itself is validated, BRIE supports evaluations that static benchmarks cannot, including the generation of multiple answers that reflect variation in clinician reasoning for robust performance assessment and continuously refreshing benchmark content to guard against leakage. Our results demonstrate that scalable benchmark generation enables rigorous, up-to-date evaluation of clinical LLMs as they are deployed in rapidly evolving healthcare settings.

0.30