CS Paper Radar

A general-purpose System One decision model for clinical records

Andrew Zhang, Trinh T. L. Vuong, Sophia J. Wagner, Dongmin Bang, Tong Ding, Yuchang Su, Mary Cipperman, Christina S. Chen, Judith Lefkes, Ramin Kahidi, Ming Y. Lu, Caiwei Tian, Tianhao Luo, Jingnan Ma, Rowland Pettit, Long Phi Le, Faisal Mahmood

cs.AI ·submitted 2026-10-19 18:00 UTC · v1

Abstract

Clinical care, health-system operations and biomedical discovery depend on extracting reliable answers from patient records, yet applying diverse clinical questions across entire populations remains computationally expensive. Here we present Clinical System One (CS1), a 4-billion-parameter decision model for fast, typed judgments from clinical records, along with two agentic harnesses in which CS1 works together with a generalist language model. CS1-4B is trained on 12.4 million questions and answers from 3.6 million patients across a multi-hospital health system, combining structured-data keys, observed outcomes and language-model supervision across clinical notes, diagnostic reports and patient timelines. It answers multiple typed questions in a single forward pass without task-specific retraining, and each answer carries a probability that can route uncertain cases to human review. On 963,408 held-out patients, CS1-4B outperformed open decision models up to 27 billion parameters on 13 of 14 tasks scored independently of its training teacher. Across 21 external data sets, its aggregate performance approached that of the strongest tested 27-billion-parameter model, with 6.4-fold faster inference in a matched workload. Integrating CS1-4B with a language model agent produced cited answers over complete multi-year patient histories and screened a patient population against the eligibility criteria of 17 registered clinical trials, placing four times as many judged-eligible patients among its top 20 candidates as keyword search while using 690-fold fewer language-model tokens than a language model reading every record. These findings support a division of labour in clinical AI, with small decision models performing repeated record reading and generative models formulating questions and synthesizing evidence.

Closest papers

Nearest neighbours by meaning across the whole index.

A Living Benchmark for Information Retrieval from Electronic Health Records

cs.AI ·2026-09-24 ·Jordan L. Cahoon, Chloe O. Stanwyck, Sulaiman Somani, Philip Chung, Kevin R Keet +21 more
benchmark similarity 0.73
Abstract

Large language model (LLM)-based clinical assistants are increasingly being integrated into electronic health record (EHR) systems, transforming how clinicians retrieve and synthesize information from patient records. Their safety and utility depend on rigorous evaluation, yet existing benchmarks are manually curated, costly to update, and rapidly become obsolete with evolving technological advancements. We present a scalable framework that automatically generates question--answer pairs from longitudinal EHR notes. Nineteen clinicians validate the benchmark generator, producing the Benchmark for Retrieving Information in EHRs (BRIE), a continuously maintainable evaluation dataset. Across nine LLMs and five inference strategies, state-of-the-art systems frequently omit clinically important information, particularly for questions requiring synthesis across multiple documents and encounters. Because the generator itself is validated, BRIE supports evaluations that static benchmarks cannot, including the generation of multiple answers that reflect variation in clinician reasoning for robust performance assessment and continuously refreshing benchmark content to guard against leakage. Our results demonstrate that scalable benchmark generation enables rigorous, up-to-date evaluation of clinical LLMs as they are deployed in rapidly evolving healthcare settings.

0.30

Clinician use of language models diverges from how the models are evaluated

cs.CL ·2026-10-08 ·Krithik Vishwanath, Haitong Lin, Anton Alyakin, Jin Vivian Lee, D. Brock Hewitt +17 more
benchmark similarity 0.73
Abstract

Large language model (LLM) assistants are being deployed to clinicians across health systems, and judgments about their readiness rest largely on benchmark scores, most of them derived from examination questions or curated cases. A benchmark predicts performance in deployment only to the extent that its items resemble real use, yet whether benchmarks reflect the work these systems receive has rarely been measured. Here we analyze 127,833 queries sent by 6,342 physicians, advanced practice providers and nurses in 35 specialties to an institutional assistant during an eight-month roll-out. We characterize each query with RCQ-Map, a clinician-validated framework grounded in taxonomies of clinical questions and of LLM evaluation, which records its task, intent, answerability, missing information and potential harm. Documentation and administration (36.2%) and knowledge retrieval (28.9%) made up nearly two-thirds of use, and diagnosis 3.7%; more than a third of queries could not be answered well as posed. Applying RCQ-Map to 58 public benchmarks drawn from major evaluation suites and frontier model reports, which we assemble into the Clinical AI Benchmark Atlas, showed that the median benchmark contained no documentation requests and shared 31% of the task mix of real use, less than an even spread across task categories would. Benchmarks in suites designed to resemble clinical practice were individually no closer to real use than those used in frontier model reports. Benchmark scores therefore say little about how clinical AI performs on most of the work it is actually given, and evaluation should be matched to real clinical use.

0.08

Route, Don't Fix: Regime-Dependent Decoding Correction and a Trajectory-Gated Router for Reliable Clinical LLM Answer Selection

cs.CL cs.AIcs.LG ·2026-09-13 ·Zeyu Dong, Benjamin Wang, Joyee W. Jin
similarity 0.72
Abstract

Large language models (LLMs) are often deemed unsafe for clinical question answering because of their tendency to hallucinate. Retrieval augmentation, fine-tuning, and external verifiers require new infrastructure that clinical governance must approve and may add latency or extra model calls. Inference-time correction uses the model's internal logit signals, but a fixed transformation need not suit every question. A corrector that improves accuracy by about ten percentage points on a truthfulness stress test yields negligible gains on clinical multiple-choice benchmarks, where instruction tuning concentrates output probability on one answer and leaves low terminal entropy. We introduce ALTAS, which reads terminal entropy and late-layer linearity ($R^2$) from one forward pass to choose per question between greedy decoding and late-layer trajectory correction. No classifier, probe, or head is trained; the router operates on candidate-answer logits and adds 6.5% latency overhead. Applied to every question, the correction improves TruthfulQA over greedy at 3B and 8B by 11.4 and 10.0 percentage points, respectively ($p<10^{-10}$). Gated per question, ALTAS retains gains of 8.3 to 9.5 percentage points while keeping MedQA, PubMedQA, and MedHallu within a one-percentage-point do-no-harm band, with no statistically significant differences from greedy. The method passes verification sweeps over frozen thresholds, the scoring rule, and the domain label.

0.21

How Reliable Are System-One Decisions in Medicine? A Comparative Study of Jev, Jev-like Models, and LLMs

cs.CL ·2026-10-13 ·Yanrui Du, Danyang Zhao, Sendong Zhao, Wenhao Li, Yibo Gao +4 more
highly cited similarity 0.71
Abstract

Jev has attracted considerable attention for its rapid, generalizable decision-making, yet its medical reliability remains underexplored. To address this gap, our study compares various types of system-one decision models across 15 medical datasets comprising 8,742 instances under a unified protocol. Beyond accuracy, we assess decision stability and the ability to recognize unreliable decisions. Our results show that Jev rivals leading models on primarily text-driven tasks but is less effective on numerically driven tasks, revealing a distinct capability boundary. Under question-format variations, Jev maintains strong decision consistency and small accuracy fluctuations. StartLux-27B exhibits comparable consistency, while D3-27B achieves higher overall accuracy and a lower mean decision reversal rate. But these strengths do not extend to reliable abstention awareness: most evaluated models show limitations in both recognizing missing correct answers and using optional abstention. Moreover, we find that Jev's probability-based answer selection can be improved by changing how decisions are scored: normalizing option-wise binary scores yields higher retained accuracy than choice scoring. Taken together, our findings provide early guidance for improving and applying decision models in medicine.

0.45

Exploring Recurrent-Depth Language Models for Multitask Clinical Text Processing

cs.CL ·2026-10-20 ·Xi Yang, Guodong Liu, Cheng Peng, Kaleb Smith, Yingying Zhang +5 more
similarity 0.71
Abstract · 8

Clinical natural language processing includes diverse tasks such as information extraction, classification, and question answering. Developing one model for all tasks could simplify deployment and improve knowledge transfer. We evaluated whether small recurrent-depth language models can meet this need through joint fine-tuning and compared their performance with standard transformers. We fine-tuned Ouro1.4B-Thinking, Ouro-2.6B-Thinking, HRM-Text-1B, Qwen3-1.7B, and Qwen3-8B on 9 datasets covering information extraction, classification, inference, and question answering, and evaluated them on four additional datasets excluded from training. Across these 13 datasets, Ouro-1.4B-Thinking achieved higher performances than Qwen3-1.7B on 11 datasets; Ouro-2.6BThinking was competitive with Qwen3-8B on most tasks. Ouro models showed the largest gains on inference and question answering, whereas HRM-Text-1B showed mixed results. These findings support further study of recurrent-depth models for clinical tasks through controlled experiments to isolate architectural effects and investigate how recurrent computation influences reasoning, knowledge acquisition, and generalization.

0.22

Structured Clinical Memory as Context for Probabilistic Decision Models: A Synthetic Evaluation with Jev

cs.AI ·2026-11-03 ·Jash Sayani, Gaurang Karwande, Achinth Bharadwaj
theory similarity 0.71
Abstract · 4 pages, 1 figure, 8 tables

Longitudinal clinical context is often distributed across noisy, repetitive forms and narrative records. We study whether a compact structured memory can improve a probabilistic decision model's answers when the underlying patient vignette is already available. We created 30 fully synthetic cases spanning twelve clinical domains, paired each with synthetically generated structured memory, and evaluated 120 typed questions with Jev. The raw-vignette arm achieved 90.0% accuracy (95% normal-approximation confidence interval: 84.6%-95.4%); adding memory achieved 93.3% (88.9%-97.8%). Five questions changed from incorrect to correct and one changed in the opposite direction (exact McNemar $p=0.219$). Choice log loss decreased from 0.258 to 0.175 and binary Brier score from 0.054 to 0.022. Memory added 310 input tokens per call on average, while observed mean latency was unchanged at approximately 0.5 seconds. These results are directionally positive rather than clinically validating: the cases are synthetic, the labels are single-author judgments, and the memory is an oracle upper bound rather than extracted production output. The pilot supports evaluating structured clinical memory as a reusable state interface for decision models.

0.10

MedJev: Evaluating Zero-Shot System-One Decision Making in Medicine

cs.CL cs.AIcs.LG ·2026-10-26 ·Simon A. Lee, Jiahang Sha, Moonseong Jeong, Yunbei Pan, Jeffrey N. Chiang
similarity 0.70
Abstract

System One decision models such as Jev answer structured questions in a single forward pass without generating text, offering fast and computationally efficient clinical decision support. We evaluate MedJev, an open System One model that runs locally on a laptop, across ten medical benchmarks spanning medical knowledge, diagnosis, and patient level prediction using MIMIC IV and MIMIC IV ED. We compare MedJev against zero shot LLM baselines, published GPT results, and supervised models. MedJev achieves accuracies of 72.5 percent on MedQA, 75.4 percent on USMLE, and 80.1 percent on NEJM, approaching published GPT 4 performance while maintaining well calibrated confidence estimates (ECE 0.028 to 0.063). On patient level tasks, MedJev achieves an AUROC of 0.926 for In Hospital Mortality, exceeding XGBoost (0.902), but underperforms supervised models on operational outcomes such as ED Triage Admission (0.745 vs. 0.809). Patient level predictions also exhibit substantial miscalibration (In Hospital Mortality ECE 0.286). We introduce a lightweight, two parameter recalibration method that adapts predictions to local patient populations using 50 to 200 labeled examples, reducing ECE to 0.007. Our findings establish open System One models as a promising zero shot baseline for medical AI, combining competitive predictive performance with low computational cost and efficient local calibration. We release our code and evaluation harness to support future research.

0.24

From Small to Large: Assessing Medical Reasoning, Benchmark Contamination, and Model Size in Language Models

cs.AI cs.CL ·2026-10-30 ·Navapat Nananukul, Mayank Kejriwal
benchmark similarity 0.70
Abstract

Large language models (LLMs) now answer medical exam questions at or above expert level, but it is unclear whether such scores reflect clinical competence, or are instead affected by the format of the questions being asked (e.g., multiple-choice versus open-ended), prior exposure to the benchmarks, and the difficulty of the questions. These benchmarks are also public and widely used online, which may be resulting in LLM memorization. Models may perform better on questions that they have seen before. It is also not evident whether smaller models, which are more locally deployable in HIPAA-compliant hospital settings, have achieved human performance. In this study, we evaluate fourteen current models from six leading providers, one smaller and one larger model from each provider with two additional open-weight models, on 3,076 questions from four medical benchmarks (MedQA-USMLE, MedMCQA, PubMedQA, and MedBullets) under standard multiple choice, the same questions with the answer choices withheld, and reconstruction of a hidden question from its choices alone. In the standard multiple-choice setting, the strongest models exceed the human-expert baseline on MedQA-USMLE and PubMedQA, but the smaller models trail their larger models by 8.7 percentage points and only two of the six pass the human-expert bar on the licensing examination. Withholding the answer choices, however, makes every model struggle: mean accuracy falls from 82.3% to 50.9%, and the two largest drops belong to the medically specialised models. On memorization, the strongest models reconstruct one question in four from the answer choices alone, yet accuracy holds on the questions they cannot reconstruct. We further weigh accuracy against inference cost and test whether ensembling several models improves medical question answering.

0.15